Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerator experiment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Diagnosing nuclear power plant pipe wall thinning due to flow accelerated corrosion using a passive, thermal non-destructive evaluation method: Feasibility assessment via numerical experiments

Flow accelerated corrosion (FAC) in nuclear power plant pipes is one of the leading causes of accidents, fatalities, damage and outages. Current FAC identification methods employ expensive sensing technology and are “active” methods, where the response of the piping system to an externally-generated thermal, mechanical or optical excitation must be measured. As a result, these techniques require a disruptive and time-consuming setup. Here we propose a method that utilizes pipe surface temperature measurements to passively monitor for FAC-induced pipe wall thinning without the need for expensive equipment or post-installation setup time. This diagnostic method utilizes a simulation data-driven diagnostic model to estimate the amount of thickness reduction in a pipe based on changes in measured steady-state pipe temperatures. In order to reduce the computational burden of generating large, simulation-based datasets, the behavior of the insulation of the pipe was modeled using a suitably calibrated heat transfer boundary parameter. Additionally, global sensitivity analysis was performed to determine system parameter(s), such as the temperature of water flowing inside the pipe, which significantly affect the steady state pipe wall temperature and could cause errors in diagnosis. Two diagnostic models, one using only the change in steady-state temperature as an indicator for FAC-induced pipe wall thinning and the other using water temperature as an additional diagnostic model input were evaluated for their ability to estimate thickness reductions in a pipe using simulated pipe wall temperature data. For the numerical experiments conducted in this work, both models estimated wall thickness with errors within 0.5 mm, indicating that the proposed technique can potentially be used as a low-cost, first-pass method for FAC monitoring.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Summary of Results for Idaho Accelerator Center (IAC) Experiments with Compact Electron Permanent Magnet Spectrometer (CEPMS)

The Compact Electron Permanent Magnet Spectrometer (CEPMS) shown in Figure 2 consists of collimation at the electron beam entrance, a vacuum chamber for beam transport and a removable 60 degree sector magnet constructed by SABR Enterprises (Ref 2) that is used to momentum analyze the incoming electron beam. There are electron detection planes located perpendicular to straight through and the 60 degree trajectory ports. The planes are designed to accept phosphor screens for time integrated measurements. The screens can be replaced by scintillator for time resolved measurements using gated or streak cameras. The length of the spectrometer along the beamline without the collimator is about 400mm (14”). The spectrometer requires no power supply with controls for cycling or cooling for the magnet. The entire assembly, with magnet installed, weighs about 35kg (75lbs) Figure 3 depicts central and extreme trajectories through the spectrometer for various electron energies. The chamber accommodates a +/-50mm wide detection field relative to the center trajectory. Trajectories with larger momentum (energy) are bent the least. Since the permanent magnet slides off and on with reference to the upstream edge of the vacuum chamber, it can be adjusted to various positions to slightly increase or decrease the central energy thereby changing the range of available energies. Figure 4 shows the effect of changing the location of the permanent magnet on the electron trajectory. A small inward change in r produces a longer trajectory in the magnet therefore, the same energy trajectory is bent more.

43 PARTICLE ACCELERATORS↗

The fixed probe storage ring magnetometer for the Muon g-2 experiment at Fermi National Accelerator Laboratory

The goal of the FNAL E989 experiment is to measure the muon magnetic anomaly to unprecedented accuracy and precision at the Fermi National Accelerator Laboratory. To meet this goal, the time and space averaged magnetic environment in the muon storage volume must be known to better than 70 ppb. A new pulsed proton nuclear magnetic resonance (NMR) magnetometer was designed and built at the University of Washington, Seattle to track the temporal stability of the 1.45 T magnetic field in the muon storage ring at this precision. It consists of an array of 378 petroleum jelly based NMR probes that are embedded in the walls of muon storage ring vacuum chambers and custom electronics built with readily available modular radio frequency (RF) components. We give NMR probe construction details and describe the functions of the custom electronic subsystems. The excellent performance metrics of the magnetometer are discussed, where after 8 years of operation the median single shot resolution of the array of probes remains at 650 ppb.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring Large Language Model Agents in Cybersecurity: A Literature Review with Experiments

The accelerated development and integration of large language model (LLM) agents have led researchers and developers to explore their effectiveness in cybersecurity, specifically with penetration testing (pentesting). Recent research efforts have attempted to use LLM agents to automate the process of pentesting because of the cost and time requirements that are required to perform a manual review. However, not all of the tools perform as expected. This paper reviews some of the newest and most popular autonomous pentesting frameworks, highlighting the capabilities and limitations of each one with the goal of providing the components needed to successfully and effectively build an autonomous pentesting agent in the future.

97 MATHEMATICS AND COMPUTING↗

Newest 3-Flavor Neutrino Oscillation Results from NOvA

NOvA is a long-baseline accelerator neutrino experiment based at the Fermi National Accelerator Laboratory observing the appearance of electron (anti)neutrinos and disappearance of muon (anti) neutrinos. The experiment consists of two functionally identical liquid scintillator detectors; a 14 kton Far Detector is situated 810 km from the beam source, while a smaller Near Detector is only 1 km from the source and samples initial beam composition consisting of primarily muon (anti)neutrinos. Through these observations NOvA is probing outstanding questions in neutrino physics including the neutrino mass ordering and leptonic CP violation along with the θ23 neutrino mixing angle and the larger neutrino mass splitting Δm232. This talk will present the most recent neutrino oscillation results, which include a larger dataset, new analysis techniques, and updated systematic uncertainties.

Sutton, Andrew↗

Experiments and Facilities for Accelerator-Based Dark Sector Searches

This paper provides an overview of experiments and facilities for accelerator-based dark matter searches as part of the US Community Study on the Future of Particle Physics (Snowmass 2021). Companion white papers to this paper present the physics drivers: thermal dark matter, visible dark portals, and new flavors and rich dark sectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Altered morphology and diffusivity of water confined in MXenes: Machine learning–accelerated computations combined with experiments

Nanoconfined water exhibits unique properties compared to bulk water due to limited quantities, frustrated hydrogen bonding, and surface interactions, which are fundamental for energy storage and transport applications. We integrate machine learning–accelerated ab initio molecular dynamics with x-ray diffraction (XRD) and inelastic neutron scattering (INS) to systematically analyze the thermodynamic and dynamic behavior of water confined between functionalized (-F, -O, and -OH) two-dimensional (2D) Ti 3 C 2 T x MXene layers. As water intercalates between layers, the interlayer spacing exhibits layer-dependent staging characteristics. The water polarization can be flipped by the count and morphology of intercalated molecules interacting with MXene surface groups, resulting in varying electrostatic potential profiles. On the basis of interfacial electrostatic potential, hydrogen bond lifetime, and molecular orientation, we establish a linear combination of exponential model describing water diffusivity. These computational insights align well with experimental x-ray and neutron measurements, suggesting strategies for tuning water morphology and transport by tailoring MXene surface chemistry and water content for electrochemical energy storage and nanofluidic applications.

Tang, Jiawei [Southeast Univ., Nanjing (China)] (O↗

Development of Superconducting RF Cavity in Traveling-Wave Regime at Fermilab

Niobium Superconducting RF (SRF) cavities have a theoretical peak magnetic field which limits the accelerating field to 50-60 MV/m. Presently, all SRF cavities operate in a Standing Wave (SW) resonance field in which particles experience an accelerating force alternating from zero to peak. In contrast, a resonance field in Traveling Wave (TW) mode propagates along with a structure, so particles in such field can experience a constant acceleration force and could have higher energy gain than that of SW mode. This phenomenon is defined by the cavity’s transit time factor, T. A TW structure proposed in an early study achieves T ~0.9, suggesting an increase in acceleration per structure by more than 20% compared to a SW structure (T ~0.7). The early stages of developments had been funded by several SBIR grants to Euclid Techlabs and completed in collaboration with Fermilab through a 1-cell prototype and a proof-of-principle 3-cell TW cavity. It demonstrated the TW resonance excitation at room temperature in the “as-fabricated” 3-cell structure. Here we report recent progresses and the first cryogenic testing of the 3-cell TW cavity in 2 K liquid helium at Fermilab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Agentic artificial intelligence for multistage physics experiments at a large-scale user facility particle accelerator

We present a language-model-driven agentic artificial intelligence (AI) system to autonomously execute multistage physics experiments on a production synchrotron light source. Implemented at the Advanced Light Source particle accelerator, the system translates natural language user prompts into structured execution plans that combine archive data retrieval, control-system channel resolution, automated script generation, controlled machine interaction, and analysis. In a representative machine physics task, we show that preparation time was reduced by 2 orders of magnitude relative to manual scripting even for a system expert, while operator-standard safety constraints were strictly upheld. Core architectural features, plan-first orchestration, bounded tool access, and dynamic capability selection, enable transparent, auditable execution with fully reproducible artifacts. These results establish a blueprint for the safe integration of agentic AI into accelerator experiments and demanding machine physics studies, as well as routine operations, with direct portability across accelerators worldwide and, more broadly, to other large-scale scientific infrastructures.

Accelerator/storage ring control systems↗

Application Experiences on a GPU-Accelerated Arm-based HPC Testbed

This paper assesses and reports the experience of ten teams working to port, validate, and benchmark several High Performance Computing applications on a novel GPU-accelerated Arm testbed system. The testbed consists of eight NVIDIA Arm HPC Developer Kit systems, each one equipped with a server-class Arm CPU from Ampere Computing and two data center GPUs from NVIDIA Corp. The systems are connected together using InfiniBand interconnect. The selected applications and mini-apps are written using several programming languages and use multiple accelerator-based programming models for GPUs such as CUDA, OpenACC, and OpenMP offloading. Working on application porting requires a robust and easy-to-access programming environment, including a variety of compilers and optimized scientific libraries. The goal of this work is to evaluate platform readiness and assess the effort required from developers to deploy well-established scientific workloads on current and future generation Arm-based GPU-accelerated HPC systems. The reported case studies demonstrate that the current level of maturity and diversity of software and tools is already adequate for large-scale production deployments.

Elwasif, Wael↗

Final Report on the Phase II Physics Proposal for T-1063: The Accelerator Neutrino Neutron Interaction Experiment (ANNIE)

The goal of ANNIE is to make the first detailed measurement of the number of neutrons produced by neutrinos interacting with nuclei. This measurement is important for understanding the results of previous and planned neutrino experiments, as neutrons carry away energy from the neutrino interactions that must be accounted for in determining the energy and neutrino type. This effort is also focused on using a new photodetector technology and key target material enhancements to enable advanced water-based neutrino detectors. The ANNIE detector has been installed in the Booster Neutrino Beam at Fermilab, which provides a pulsed source of neutrinos in the energy range of 300-1200 MeV, which is relevant for the next generation of neutrino experiments. In 2017-2018 measurements of the neutron background in this beam were made with a partially-instrumented ANNIE detector. These measurements guided our design of the upgraded detector now built. The upgrade has been realized by adding Large Area Picosecond Photodetectors (LAPPDs) for the first time, more conventional photomultiplier tubes (PMTs), as well as adding electronics channels to the existing data acquisition system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Apex Study: Compensating Transient Beam Loading in the RHIC 28 MHZ

With the EIC on the way, it is important that developments and strategies are in place to deal with the very high beam currents that the machine will feature. Specifically, the EIC will collide beams of up to 2.5 A, three times the beam current in RHIC. This higher beam current will cause significant voltage transients in the cavity fields which can lead to longitudinal instabilities and beam loss. In anticipation of these negative effects, studies were carried out on the RHIC 28 MHz cavities using newly developed firmware and software to diagnose and combat beam loading. Diagnostic tools such as the bunch-by-bunch (BbyB) ADC firmware and digital network analyzer (DNA) were used to characterize the closed loop system and transient on the cavity voltage magnitude and phase. Then, a one-turn delay feedback (OTFB) and adaptive feed-forward (aFFWD) were used to minimize the transient beam loading. The studies were carried out with beam during 2 accelerator physics experiements (APEXs) using one of the 28 MHz accelerating cavities here at RHIC.

43 PARTICLE ACCELERATORS↗