Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerated Stress Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Sparsely Dispersed CeO x ‑Stabilized Pt Nanoparticles Overcome Pt Loading–Durability Trade-Off for Highly Durable Heavy-Duty Fuel Cells

Proton-exchange-membrane fuel cells (PEMFCs) are clean and sustainable mobile power sources for transportation. Recently, their deployment in heavy-duty vehicles (HDVs) has attracted growing interest owing to their high energy scalability and lower infrastructure requirements. However, to meet the stringent requirements for efficiency and long-term durability for HDV applications, PEMFCs typically employ a relatively high platinum group metal (PGM) loading (>0.2 mg PGM /cm 2 ). This elevated PGM loading significantly increases the stack and system costs, surpassing the U.S. Department of Energy (DOE) target of $\$ 60$/kW for commercial viability. Reducing PGM loading while maintaining performance and durability remains a central challenge for HDV fuel cells. Here we exploit metal oxide–Pt interactions and utilize the strong CeO x –Pt interaction to design a CeO x @Pt catalyst structure with exceptional durability. At a low total PGM loading (0.1 mg PGM /cm 2 ), the CeO x @Pt/C catalyst demonstrates high fuel cell performance (8.8 kW/g PGM ) and stability (power retention >90%) after the challenging HDV durability testing (90,000 accelerated-stress-test cycles). With the CeO x @Pt/C catalyst, we showcase over 70% reduction in Pt cost from the M2FCT target (to $\$ 9$/kW), highlighting its promising potential for enabling stable and cost-effective fuel cell systems for heavy-duty applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigating the Particle Growth in Bimodal Pt/C Catalysts by In-Situ Small-Angle X-ray Scattering: Challenges in the Evaluation of Stress Test Protocol-Dependent Degradation Mechanisms

The influence of different combinations of accelerated stress test (AST) protocols simulating load-cycle and start/stop conditions of a proton exchange membrane fuel cell (PEMFC) vehicle is investigated on a bimodal Pt/C catalyst. The bimodal Pt/C catalyst, prepared by mixing two commercial catalysts, serves as a model system and consists of two distinguishable size populations. The change in mean particle size was investigated by in situ small-angle X-ray scattering (SAXS). The comparison to the reference catalysts, i.e., the two single-size population catalysts, uncovers the presence of electrochemical Ostwald ripening as a degradation mechanism in the bimodal catalyst. Increasing the harshness of the applied AST protocol combinations by faster changing between load-cycle or start/stop conditions, the particle size of the larger population of the bimodal catalyst increases faster than expected. Surprisingly, the change in mean particle size of the smaller size population indicates a smaller increase for harsher AST protocols, which might be explained by a substantial electrochemical Ostwald ripening.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PACT Perovskite PV Module Stress Testing Protocol (Version 0.0)

The purpose of this protocol is to use accelerated stress testing to assess the durability of metal halide perovskite (MHP) photovoltaic (PV) modules. The protocol aims to apply field relevant stressors to packaged MHP modules to screen for early failures that may be observed in the field. The current protocol has been designed with a glass/glass-PIB edge seal, no encapsulant package in mind. PACT anticipates adding additional testing sequences to evaluate additional stressors (e.g., PID, reverse bias) in the future.

42 ENGINEERING↗

Reproducing the 'Framing' by a Sequential Stress Test

The 'Framing' (local discoloration along cell edges) was induced by a simple sequential accelerated stress test (consisting of hygrothermal- and UV-stressors) applied to the PV modules with high OTR (oxygen transmission rate) backsheet, irrespective of the inclusion of UV-absorber in poly(ethylene-co-vinyl acetate) (EVA) encapsulant. UV-fluorescence imaging of the PV modules suggests that the spatially-inhomogeneous degradation of EVA material under UV-irradiating conditions is correlated to this 'Framing' indicating an underlying common mechanism. These findings would contribute to the development of test procedures to broadly mimic the actual failures observed in fielded PV.

14 SOLAR ENERGY↗

A study of degradation mechanisms in PVDF-based photovoltaic backsheets

Abstract Commercial backsheets based on polyvinylidene fluoride (PVDF) can experience premature field failures in the form of outer layer cracking. This work seeks to provide a better understanding of the changes in material properties that lead to crack formation and find appropriate accelerated tests to replicate them. The PVDF-based backsheet outer layer can have a different structure and composition, and is often blended with a poly(methyl methacrylate) (PMMA) polymer. We observed depletion of PMMA upon aging with sequential (MAST) and combined (C-AST) accelerated stress testing. In field-aged samples from Arizona and India, where PVDF crystallizes in its predominant α-phase, the degree of crystallinity greatly increased. MAST and C-AST protocols were, to some extent, able to replicate the increase in crystallinity seen in PVDF after ~ 7 years in the field, but no single-stress test condition (UV, damp heat, thermal cycling) resulted in significant changes in the material properties. The MAST regimen used here was too extreme to produce realistic degradation, but the test was useful in discovering weaknesses of the particular PVDF-based outer layer structure studied. No excessive β-phase formation was observed after aging with any test condition; however, the presence of β-phase was identified locally by Fourier transform infrared spectroscopy (FTIR). We conclude that both MAST and C-AST are relevant tests for screening outdoor failure mechanisms in PVDF backsheets, as they were successful in producing material degradation that led to cracking.

14 SOLAR ENERGY↗

Relief Zones Enhance the Durability of Ultrathin Membranes in Electrochemical Conversion Devices

Premature failures in electrochemical conversion systems often result when membrane electrode assemblies (MEAs) use ultrathin (≤15 μm-thick) polymer electrolyte membranes, susceptible to mechanical degradation from stress concentrations arising from device-level integration. Herein, relief zones were developed to mitigate mechanical degradation by alleviating excess and nonuniform compression across active areas. Relief zones, created through ablation of carbonaceous diffusion media, enable seamless adaptation across MEA dimensions without need for hardware modifications. Demonstrated using fuel cells as a case study, accelerated stress tests revealed a 6-fold lifetime improvement (∼1500 h) compared to conventional edge-protected MEAs, decoupling device-level engineering effects from material limitations.

accelerated stress test↗

A Relief Zone Architecture for Enhanced Durability of Ultrathin Membranes in Electrochemical Conversion Devices

Premature cell failures in electrochemical conversion systems often result when membrane electrode assemblies (MEAs) are prepared with ultra-thin (= 15 micrometer-thick) polymer electrolyte membranes (PEMs). These high-performance PEMs are susceptible to mechanical degradation from stress concentrations arising from component and device-level integration. Herein, a relief zone was developed to mitigate mechanical degradation by alleviating excess and non-uniform compression across the active area. Relief zones, created through the ablation of carbonaceous diffusion material achieves a seamless adaptation across a range of MEA dimensions and electrochemical applications without need for costly hardware modifications. This concept was demonstrated using fuel cells as a case study. Accelerated stress test (AST) validations yielded a 6-fold improvement for MEAs prepared with relief zones (i.e., lifetime approximately 1500 h) compared to those fabricated using conventional edge-protection techniques, showcasing the utility of this technique in decoupling integration and device-level engineering effects from intrinsic material limitations for durable electrochemical devices.

14 SOLAR ENERGY↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The influence of electrode crack dimensions on the durability of polymer electrolyte membrane fuel cells

Electrode cracks in polymer electrolyte membrane fuel cells (PEMFCs) are correlated with early onset failures. Here, in this work we investigate the influence of cracked gas diffusion electrodes (GDEs) on the durability of the membrane electrode assembly (MEA) using a combined chemical-mechanical accelerated stress test (AST). Electrode crack dimensions were systematically tuned using ink formulations and material selection strategies. A parameter to describe the crack width areal density (Φ CW ) was used to quantify the degree of discontinuity in the electrode surfaces. Open circuit voltage (OCV) transient analyses were used to benchmark and characterize the failure mechanisms in the MEAs as a function of the Φ CW . While smaller electrode-level cracks, on the order of microns, yielded a 28 % decrease in operating lifetime, larger cracks that propagated from a discontinuous, microporous layer (MPL) coating, decreased the operating lifetime by 56 %. This work emphasizes the need for material processing strategies that consider defect tolerances to limit membrane failures in PEMFCs.

08 HYDROGEN↗

Studying the Durability of Molybdenum Carbide Aerogel as an Electrocatalyst Support for Proton Exchange Membrane Fuel Cells

Carbon-supported platinum nanoparticles (Pt/C) are currently the state-of-the-art catalyst in proton exchange membrane fuel cells (PEMFCs). Unfortunately, the carbon support lacks the ability to stabilize the metal catalyst, as platinum tends to dissolve and agglomerate, significantly compromising the durability. Herein, we synthesized a ceramic material, molybdenum carbide aerogel (MCAG), and utilized it as a Pt support for PEMFCs, as an alternative for conventional carbon supports. N 2 adsorption and XRD analysis showed that the MCAG possesses a combination of high porosity and a well-defined ceramic crystalline structure. The Pt/MCAG system was studied for its electrocatalytic activity toward ORR in a half-cell and demonstrated satisfactory reaction kinetics and electrochemical active surface area, comparable to the commercial Pt/C. For durability examination, an accelerated stress test (AST) in a single cell was conducted with the Pt/MCAG catalyst at the cathode, following the U.S. DOE electrocatalyst AST protocol. Intermediate polarization curves and cyclic voltammograms were recorded over the course of the AST to monitor the aging process. The results indicated that the MCAG support exhibited superior durability in long-term fuel cell operation compared to a carbon support. The Pt/MCAG system demonstrated stable behavior during the progressive stages of the AST, retaining more than 50% of its initial performance by the end of the test, whereas carbon-supported Pt preserved only 30%.

25 ENERGY STORAGE↗

The impact of hot-press conditions on the durability of polymer electrolyte membrane fuel cells

The proton exchange membrane integrity can be compromised during hot-press fabrication of membrane electrode assemblies (MEAs) causing premature cell failures during operation. In this work, infrared (IR) thermography was used as a diagnostic tool to spatially visualize hydrogen (H 2 ) crossover and identify process-induced-membrane irregularities (PIMs). These irregularities were identified as seed locations for MEA failures. Fine tuning of hot-press conditions was used to mitigate premature cell failures informed by accelerated stress testing (AST). The impact of PIMs on the initial performance, high-frequency resistances, open-circuit voltage, and H 2 crossover are reported. Nafion XL and 212 membranes, hot-pressed with a force of 16 kg/cm 2 and temperature of 120°C, were found to be consistently irregularity-free. Irregularity-free MEAs using Nafion 211, 212, and XL membranes demonstrated AST lifetime improvements of 58, 64 and 400%, respectively, compared to those fabricated with non-optimized conditions. In conclusion, this work highlights the importance of fabrication parameters on premature cell failures.

08 HYDROGEN↗

High Performance non-PGM Transition Metal Oxide ORR Catalysts of PEMFCs

This project was designed to develop acid-stable PGM-free transition metal oxide oxygen reduction reaction (ORR) electrocatalysts to meet or exceed the performance and durability of the DOE 2020 Technical Targets for platinum-group metal (PGM) free electrocatalysts from first-principles to incorporation into membrane-electrode assemblies (MEAs) for polymer electrolyte membrane (PEM) fuel cells. The planned project was to accomplish this goal with a multi-step approach: 1) materials modeling and experimental screening to identify acid-stable oxides with high ORR activity, 2) optimization of catalyst particle size and catalyst/carbon/ionomer catalyst layer composition, 3) fabrication of MEAs for performance and durability testing. During the course of this project: 1) acid-stability descriptors were developed for manganese oxides; 2) a family of acid-stable multicomponent oxides based on antimony were developed; 3) a flexible synthesis for the formation of nanocrystalline nonstoichiometric oxides was developed; 4) limited ORR activity but modest and improving oxygen evolution reaction (OER) activity was measured for multicomponent antimony oxides. The project was programmed into five technical tasks: The development of acid-stable ORR electrocatalytic oxides through 1) identification and optimization of acid-stable oxide compositions, and 2) electrochemical characterization; 3) optimization of catalyst layer composition for MEAs using identified ORR electrocatalysts; 4) MEA fabrication and performance testing to result in performance of 44 mA-cm-2 at 0.9 V vs. RHE; and 5) accelerated-stress testing of optimized MEAs. Because no acid-stable oxide was identified with the requisite activity for ORR (4.4 µA-cm-2oxide intrinsic activity at 0.9 V vs. RHE) within the time and budget allotted in Tasks 1 and 2, the project was halted at the end of phase 1, with no activity in Tasks 3-5. The research output, while not succeeding in developing ORR electrocatalysts, advanced the development of acid-stable oxide materials, showing potential for further improvement as OER electrocatalysts.

08 HYDROGEN↗

Effect of Engineered Cracks in Catalyst Layers on PEMFC Catalyst Layer Durability

Proton exchange membrane fuel cells (PEMFCs) are expected to play a pivotal role in decarbonizing the transportation sector, and particularly heavy-duty vehicles (HDVs). However, improvements in durability are needed for PEMFCs to compete with state-of-the-art power sources for HDVs. Here, we examine how catalyst layer (CL) cracks that are engineered affect the CL durability by using patterned silicon templates to control the CL crack density at the micrometer scale. Electrochemical analyses show that the initial PEMFC performance is relatively unaffected by crack density, but the performance after durability testing was strongly affected. Specifically, CLs with high crack density showed higher performance relative to CLs without cracks after application of a carbon corrosion accelerated stress test. Electrochemical analyses coupled with X-ray computed tomography and scanning transmission electron microscopy with energy dispersive X-ray spectroscopy showed that the cracks provide shorter oxygen diffusion pathways to reaction sites, leading to decreased oxygen transport resistance. Additionally, we observed that the catalyst durability is unaffected by cracks. Our results provide a mechanistic explanation of the role of cracks in CL durability.

30 DIRECT ENERGY CONVERSION↗

Composite PEMs from Electrospun Crosslinkable Poly(Phenylene Sulfonic Acid)s (Final Technical Report)

The main objective of this project is to fabricate and demonstrate superior fuel cell performance of an electrospun composite all-hydrocarbon, non-PFSA membrane. The project builds on two earlier, DOE-funded studies demonstrating high proton conductivity, even at very low humidity of crosslinkable poly(phenylenesulfonic acid), cPPSA, solution cast films, and high durability of electrospun perfluorosulfonic acid (PFSA) composite membranes. Most project milestones were fully met but the best membrane conductivity and fuel cell performance were obtained with membranes that did not contain electrospun sulfonated polyphenylene, as initially planned. Instead, an excellent performance was achieved with membranes fabricated by pore-filling, either with electrospun poly(phenyl sulfone) scaffolds or with commercial, expanded polytetrafluoroethylene scaffolds. Fuel cell testing demonstrated performance better than that of Nafion 211 or Nafion XL, particularly at lower cell humidification levels with significantly lower hydrogen crossover. No accelerated stress testing was performed, due to the initial numerous difficulties with controlling the copolymerization reaction, which took excessive amount of time to overcome. Potential scale-up of the proposed composite membrane technology can aid in boosting the fuel cell power output and simplification of the cell hydration system.

08 HYDROGEN↗

Evaluation of the Reliability of Passive Infrared (PIR) Occupancy Sensors for Residential Indoor Lighting

Solid-state lighting (SSL) technologies have penetrated the general illumination market in recent years, largely replacing conventional technologies such as incandescent and fluorescent lighting. Most of the initial excitement about light-emitting diode (LED) sources for SSL devices focused on their energy savings potential resulting from vast improvements in source efficiency and luminous efficacy compared with conventional illumination products. More recently, the focus has shifted toward other aspects of lighting application efficiency, namely intensity effectiveness and spectral efficiency, because of the ease of controlling both the light intensity of LEDs with drive voltage and the color properties of the LED-based illuminators. To capitalize on the energy savings of increased intensity effectiveness and spectral efficiency, a lighting control system (LCS) is often used. While the current penetration of LCSs is relatively modest, it is anticipated that lighting controls (i.e., connected lighting, controls and LED and conventional lighting) could have an installed penetration as higher as 46% by the year 2035, saving an additional 1.3 quads of energy. Despite the large energy savings that can be gained from using LCSs, standard test methods for evaluating sensors employed in LCSs and reliability data of the LCSs and their components are generally lacking. The National Electrical Manufacturers Association (NEMA) developed the only standard, NEMA WD 7-2011 (R2016), to test occupancy and motion sensor performance (herein referred to as “the NEMA protocol”). In a previous U.S. Department of Energy (DOE) effort, some concerns of the NEMA protocol were identified (e.g., strict height and weight limits on test subjects, large amounts of manual effort, sometimes inconsistent repeatability). During the current work, a consistent detection length test (DLT) and a Robotic Sensor Evaluation System (RoboSES) were developed to alleviate some of these concerns. RoboSES acts as a human surrogate by using thermal pads on a mannequin and a remote-controlled mobile base to test a sensor’s field of view (FOV). This report builds on the earlier DOE efforts to understand sensor technologies used in LCSs for general illumination. Specifically, this report describes the optimization of RoboSES, characterizes and establishes test methods to assess the reliability of multiple passive infrared (PIR) sensors, and reports the findings of robustness and reliability testing on two commercial PIR sensors intended for residential applications. The information presented in this report is gained from up to 4,000 hours (hrs) of accelerated stress tests (ASTs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field‐Relevant Degradation Mechanisms in Metal Halide Perovskite Modules

Field testing, failure analysis, and understanding of degradation mechanisms are essential to advancing metal halide perovskite (MHP) photovoltaic (PV) technology toward commercialization. Here, we present performance data from up to 1 year of outdoor testing of MHP modules in Golden, Colorado. The module encapsulation architecture and encapsulant materials have a significant impact on module reliability, with modules containing a polyolefin elastomer (POE) in addition to a desiccated polyisobutylene (PIB) edge seal outlasting modules with only a PIB edge seal or PIB blanket. Nondestructive and destructive characterization of the field-tested modules points to module scribes and interfaces as areas of potential mechanical weakness and chemical migration, resulting in shunt pathways and increased series resistance. Finally, indoor accelerated stress testing with light and elevated temperatures is performed, demonstrating failure with similar scribe degradation signatures as compared to the field-tested modules. In conclusion, under both outdoor testing and light and elevated temperature conditions, electrochemical corrosion between the copper electrode and the mobile iodine ions appeared dominant, with a significant progression at the scribes that is speculated to result from an interplay between the initial laser damage and joule heating from enhanced ion diffusion under bias.

14 SOLAR ENERGY↗

(Invited) Fuel Cell Component Durability for Million Mile Fuel Cell Trucks

While significant advances have been made and early commercial fuel cell light-duty vehicles (LDVs) are starting to be produced, fuel cells in the heavy-duty-vehicle (HDV) transportation sector (including trucks, long-haul semitrailers, maritime, trains, etc.) are nascent, despite the fact that advantages of fuel cells compared to both diesel and electric powertrains are very compelling in terms of emissions, charging time, efficiency, power-to-weight ratio, among others. However, the fuel-cell technology for HDVs requires a paradigm shift in fuel-cell research and development compared to LDVs, where the emphasis becomes efficiency and improvements in durability instead of a focus on increased power densities and lower cell costs. Heavy-duty applications require significantly longer vehicle lifetimes (>25,000 hours/1,000,000 miles for heavy-duty trucks), and therefore require improved fuel cell durability compared to light-duty vehicles. In 2020, HFTO formed the Million Mile Fuel Cell Truck Consortium (M2FCT) that includes a core team of five national laboratories to overcome durability and efficiency challenges in PEMFCs for heavy-duty applications with an initial focus on long-haul trucks. While targets and testing protocols have been developed for light-duty vehicles, the same level of targets and testing protocols have not been established for heavy-duty transportation. With operational times of greater than > 25,000 hours required, the need for well-developed accelerated stress tests (ASTs) is amplified. Results from these ASTs demonstrate the need for more durable electrode layers and well-controlled potential variations. Finally, this presentation will provide an overview of the DOE's Fuel Cell R&D approach, highlighting past and current activities, as well as strategies to enable fuel cell competiveness for heavy-duty applications.

25 ENERGY STORAGE↗