Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AUTOCLAVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Cracking in autoclaved aerated concrete: Experimental investigation and XFEM modeling

The paper aims to investigate and model cracking development in beams and deep-beams made of autoclaved aerated concrete (AAC). Fracture mechanics of AAC has been first studied by performing three-point bending tests on beams, similar to those commonly used for ordinary concrete elements. In some of these tests, crack growth has been also monitored by using ESPI laser technique. In this way, it has been possible to calibrate the main parameters of a proper cohesive law by means of extended finite element inverse analysis. Subsequently, cracking tests have been also performed on deep-beams, whose behavior is more representative of full scale walls. To validate the proposed cohesive law, deep-beam experimental behavior has been finally simulated through XFEM.

36 MATERIALS SCIENCE↗

Autoclave grid-to-rod fretting wear evaluation of a candidate cladding coating for accident-tolerant fuel

In pressurized water reactors (PWRs), water flow induced vibrations cause contact and rubbing between the fuel rods and the supporting grid, a phenomenon known as Grid-to-Rod-Fretting (GTRF). GTRF may produce progressive wear damage on the fuel claddings leading to subsequent leakage of radioactive fission products. Various accident-tolerant fuel (ATF) concepts are being developed for higher resistance to the high temperature steam and one approach is to apply a cladding coating. Here, fretting wear behavior of a candidate Cr-coating was investigated using a unique bench-scale autoclave testing rig mimicking the environment in an industrial full-assembly PWR simulator. The contact was under a realistically low load (~0.5 N) lubricated by deionized water at a temperature of 204 °C under a pressure of 20-23 bars. Results demonstrated that the Cr-coating significantly improved the cladding's wear resistance when tested against a commercial ZIRLO grid with or without pre-oxidization. In addition, the Cr-coating also reduced wear on the non-oxidized ZIRLO grid but slightly increased the wear on the pre-oxidized grid.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Autoclave Corrosion Experiment of Zircaloy-4 at Temperatures Between 180 deg. C and 270 deg. C - 19167

Corrosion of zirconium alloys is a key issue for the overall nuclear industry that has been studied under various temperatures for plant operation, severe accidents, storage, and final disposal of spent cladding. The present work aims to investigate the corrosion kinetics of zirconium alloys at intermediate temperature regions between the operation and storage/disposal conditions, to examine if the extrapolation of high temperature data to lower temperatures is valid. To achieve this, an autoclave experiment, which is a common way to study corrosion behavior, was applied for up to 485 days at 4 different temperatures: 180 deg. C, 210 deg. C, 240 deg. C and 270 deg. C. The weight gain changes due to the oxide growth of the PWR cladding tube (Zircaloy-4) showed that the corrosion kinetics in temperatures above 210 deg. C follow the cubic rate law. The activation energy evaluated by the Arrhenius relationship of the cubic rate constants was determined and found to be 132.8 ± 0.6 kJ/mol, which corresponds to that generally reported under the operation temperatures. However, the kinetics at 180 deg. C was found to be close to the parabolic rate law, which suggests the kinetics changes from cubic to parabolic around 200 deg. C. Thus, it is unlikely to predict accurately long-term corrosion behavior under storage and disposal conditions by simply extrapolating the high temperature corrosion data. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Grid-to-rod fretting wear study of SiC/SiC composite accident-tolerant fuel claddings using an autoclave fretting bench test

Grid-to-rod-fretting (GTRF) in pressurized water reactors (PWRs) is known to cause wear and surface damage on the fuel claddings, potentially leading to radioactive leakage. One of the accident-tolerant fuel (ATF) concepts is to use advanced cladding materials that could withstand higher temperatures. Here, we investigated the wear behavior of candidate silicon carbide (SiC)-based composite claddings with different levels of surface finish in fretting against a commercial ZIRLO alloy grid using a unique bench-scale autoclave GTRF rig. The experiments mimicked the environment in an industrial full-assembly PWR simulator. Fretting tests were conducted with a realistic load (~0.5 N) in deionized water under a pressure of 20–23 bar at 204 °C for 100 h. While the SiC/SiC composite claddings showed significantly higher wear resistance than the commercial ZIRLO alloy cladding as expected, the smoother versions experienced surprisingly higher wear than the much softer counterface, ZIRLO grid. The wear mechanism of the SiC/SiC cladding was attributed to the SiC wear debris that was trapped at the fretting interface causing both 3-body and 2-body (embedded into the grid surface) abrasion of the cladding. Rougher SiC/SiC claddings had less material loss but caused more wear on the ZIRLO grid. Finally, pre-oxidized ZIRLO grid showed better compatibility with the SiC/SiC cladding to protect both the cladding and grid as a result of reduced wear debris trapping.

36 MATERIALS SCIENCE↗

Infrared Signatures to Discriminate Viability of Autoclaved Bacillus Spores

Optical methods can offer good sensitivity for detecting small amounts of chemicals and biologicals, and as these methods mature, are some of the few techniques that can offer true standoff detection. For detection of biological species, determining the viability is clearly important: Certain species of gram-positive bacteria are capable of forming endospores, specialized structures that arise when living conditions become unfavorable or little growth medium is available, being resistant to many chemicals as well as changes in heat or pH. Such spores can remain dormant from months to years until more favorable conditions arise, resulting in germination back to the vegetative state. This persistence characteristic of bacterial spores allows for contamination of a surface (e.g. food or medical equipment) even after the surface has been nominally cleaned. Bacterial spores have also been used as biological weapons, as in the case with B. anthracis. Thus, rapid analysis to determine a spore's viability in a given environment or after attempts to sterilize a given environment is crucial. The increasing availability of portable spectrometers may provide a key to such rapid onsite analysis. The present study was designed to determine whether infrared spectroscopy may be used to differentiate between viable vs. dead B. subtilis and B. atrophaeus spores. Preliminary results show that the reproducible differences in the IR signatures can be used to identify viable vs. autoclaved (dead) B. subtilis and B. atrophaeus bacterial spores.

Schneider, Matthew D↗

Comparison of woven and stitched out-of-autoclave E-glass/epoxy composites subjected to quasi-static and cyclic tensile loads

Tensile quasi-static and fatigue behaviors of out-of-autoclave, quasi-isotropic, E-glass/epoxy composites with woven and stitched fiber architectures are compared. Some specimens were cyclically loaded to failure, while others were tested for residual modulus and ultimate strength. Both laminates survived 10 7 cycles at a maximum stress of 94.8 MPa but failed prior to 10 7 cycles at a maximum stress greater than or equal to 124.1 MPa. For the stress-lifetime diagram and residual strength, the woven laminate had superior properties below 10 4 cycles and the stitched laminate had superior properties above 10 5 cycles. While intralaminar crack density was higher in the stitched laminate, the woven laminate demonstrated a higher percentage of delaminated area.

Materials Science↗

The Development of High Temperature Thermoplastic Composite Materials for Additive Manufactured Autoclave Tooling

In this work, ORNL and Techmer investigated and screened different high temperature thermoplastic reinforced materials to fabricate composite molds for autoclave processes using Additive Manufacturing (AM) techniques. This project directly led to the development and commercial release of two printable, high temperature composite materials available through Techmer PM. These new materials are targeted for high temperature tooling made via large scale additive manufacturing.

36 MATERIALS SCIENCE↗

Low-void polyimide resins for autoclave processing

Development of an advanced A-type polyimide, which can be used to produce autoclave molded, low-void content composites suitable for use at temperatures up to 316 C is reported. It consists of a mixture of methyl nadic anhydride, an 80:20 molar ratio of methylene dianaline and thiodianilene, and pyromellitic dianhydride.

Jones, R. J.↗

Development of a low void polyimide resin for autoclave processing of glass and graphite reinforced composites.

Experimental studies are described in which new A-type polyimide prepolymer chemical modifications were investigated with the aim of increasing the melt phase duration and temperature range permitting autoclave processing, yet retaining the addition-type cure mechanism required for low-void content composites. Several modification candidates were examined, and one specific formulation was selected for detailed investigation. This A-type polyimide prepolymer formulation is shown to possess the desired characteristics.

Vaughan, R. W.↗

Effect of processing parameters on autoclaved PMR polyimide composites

A study was conducted to determine the effect of processing parameters on the processability and properties of autoclaved fiber reinforced PMR polyimide composites. Composites were fabricated from commercially available graphite fabric and glass fabric PMR polyimide prepreg materials. Process parameters investigated included degree of resin advancement, heating rate, and cure pressure. Composites were inspected for porosity by ultrasonic C scan and photomicrographic examination. Processing characteristics for each set of process parameters and the effect of process parameters on composite mechanical properties at room temperature and 600 F are described.

Vannucci, R. D.↗

Effect of processing parameters on autoclaved PMR polyimide composites

A study was conducted to determine the effect of processing parameters on the processability and properties of autoclaved fiber reinforced PMR polyimide composites. Composites were fabricated from commercially available graphite fabric and glass fabric PMR polyimide prepreg materials. Process parameters investigated included degree of resin advancement, heating rate, and cure pressure. Composites were inspected for porosity by ultrasonic 'C' scan and photomicrographic examination. Processing characteristics for each set of process parameters and the effect of process parameters on composite mechanical properties at room temperature and 600 F are described.

Vannucci, R. D.↗

Applications of mass spectrometry techniques to autoclave curing of materials

Mass spectrometer analysis of gases evolved from polymer materials during a cure cycle can provide a wealth of information useful for studying cure properties and procedures. In this paper data is presented for two materials to support the feasibility of using mass spectrometer gas analysis techniques to enhance the knowledge of autoclave curing of composite materials and provide additional information for process control evaluation. It is expected that this technique will also be useful in working out the details involved in determining the proper cure cycle for new or experimental materials.

Smith, A. C.↗

Autoclave processing for composite material fabrication. 1: An analysis of resin flows and fiber compactions for thin laminate

High quality long fiber reinforced composites, such as those used in aerospace and industrial applications, are commonly processed in autoclaves. An adequate resin flow model for the entire system (laminate/bleeder/breather), which provides a description of the time-dependent laminate consolidation process, is useful in predicting the loss of resin, heat transfer characteristics, fiber volume fraction and part dimension, etc., under a specified set of processing conditions. This could be accomplished by properly analyzing the flow patterns and pressure profiles inside the laminate during processing. A newly formulated resin flow model for composite prepreg lamination process is reported. This model considers viscous resin flows in both directions perpendicular and parallel to the composite plane. In the horizontal direction, a squeezing flow between two nonporous parallel plates is analyzed, while in the vertical direction, a poiseuille type pressure flow through porous media is assumed. Proper force and mass balances have been made and solved for the whole system. The effects of fiber-fiber interactions during lamination are included as well. The unique features of this analysis are: (1) the pressure gradient inside the laminate is assumed to be generated from squeezing action between two adjacent approaching fiber layers, and (2) the behavior of fiber bundles is simulated by a Finitely Extendable Nonlinear Elastic (FENE) spring.

Hou, T. H.↗

Modeling the curing process of thick-section autoclave cured composites

Temperature gradients are significant during cure of large area, thick-section composites. Such temperature gradients result in nonuniformly cured parts with high void contents, poor ply compaction, and variations in the fiber/resin distribution. A model was developed to determine the temperature distribution in thick-section autoclave cured composites. Using the model, long with temperature measurements obtained from the thick-section composites, the effects of various processing parameters on the thermal response of the composites were examined. A one-dimensional heat transfer model was constructed for the composite-tool assembly. The governing differential equations and associated boundary conditions describing one-dimensional unsteady heat-conduction in the composite, tool plate, and pressure plate are given. Solution of the thermal model was obtained using an implicit finite difference technique.

Loos, A. C.↗

Optimal cure cycle design for autoclave processing of thick composites laminates: A feasibility study

The thermal analysis and the calculation of thermal sensitivity of a cure cycle in autoclave processing of thick composite laminates were studied. A finite element program for the thermal analysis and design derivatives calculation for temperature distribution and the degree of cure was developed and verified. It was found that the direct differentiation was the best approach for the thermal design sensitivity analysis. In addition, the approach of the direct differentiation provided time histories of design derivatives which are of great value to the cure cycle designers. The approach of direct differentiation is to be used for further study, i.e., the optimal cycle design.

Hou, Jean W.↗

Making Large Composite Vessels Without Autoclaves

Method for making fiber-reinforced composite structure relies on heating and differential thermal expansion to provide temperature and pressure necessary to develop full strength, without having to place structure in large, expensive autoclave. Layers of differentially expanding material squeeze fiber-reinforce composite between them when heated. Method suitable for such cylindrical structures as pressure vessels and tanks. Used for both resin-matrix and metal-matrix composites.

Sigur, W. A.↗