Small UHV compatible hyperthermal oxygen atom generator

A high purity, hyperthermal, continuous beam atomic oxygen source capable of retrofitting to existing UHV systems has been developed. The instrument complements a general system capability, while its small size and simplicity of design permits tailoring the instrument for most experimental geometries. The flux level presently available is near 1 x 10 (exp 14) cm(exp -2)s(exp -1)(3P) but may be extended toward the theoretical limit of 3x10(exp 15 cm(exp -2)s(exp -1). The energy distribution of the emitted neutrals shows that the mean kinetic energy is about the same as observed for the ions or about 4 eV. The energy of the oxygen atoms may be substantially reduced for other applications by collision with a temperature controlled, non-reactive surface (with a concomitant spread in the energy distribution).

Outlaw, Ronald A.↗

Reactions between NO/+/ and metal atoms using magnetically confined afterglows

A new method of studying thermal energy ion-neutral collision processes involving nongaseous neutral atoms is described. A long magnetic field produced by a solenoid in a vacuum chamber confines a thermal-energy plasma generated by photoionization of gas at very low pressure. As the plasma moves toward the end of the field, it is crossed by a metal atom beam. Ionic products of ion-atom reactions are trapped by the field and both the reactant and product ions move to the end of the magnetic field where they are detected by a quadrupole mass filter. The cross sections for charge transfer between NO(+) and Na, Mg, Ca, and Sr and that for rearrangement between NO(+) and Ca have been obtained. The charge-transfer reaction is found strongly dominant over the rearrangement reaction that forms metallic oxide ions.

Lo, H. H.↗

Repetitive Interrogation of 2-Level Quantum Systems

Trapped ion clocks derive information from a reference atomic transition by repetitive interrogations of the same quantum system, either a single ion or ionized gas of many millions of ions. Atomic beam frequency standards, by contrast, measure reference atomic transitions in a continuously replenished "flow through" configuration where initial ensemble atomic coherence is zero. We will describe some issues and problems that can arise when atomic state selection and preparation of the quantum atomic system is not completed, that is, optical pumping has not fully relaxed the coherence and also not fully transferred atoms to the initial state. We present a simple two-level density matrix analysis showing how frequency shifts during the state-selection process can cause frequency shifts of the measured clock transition. Such considerations are very important when a low intensity lamp light source is used for state selection, where there is relatively weak relaxation and re-pumping of ions to an initial state and much weaker 'environmental' relaxation of the atomic coherence set-up in the atomic sample.

Rabi interrogation↗

Absolute elastic differential electron scattering cross sections for He - A proposed calibration standard from 5 to 200 eV

Absolute differential, integral, and momentum-transfer cross sections for electrons elastically scattered from helium are reported for the impact energy range of 5 to 200 eV. Angular distributions for elastically scattered electrons are measured in a crossed-beam geometry using a collimated, differentially pumped atomic-beam source which requires no effective-path-length correction. Below the first inelastic threshold the angular distributions were placed on an absolute scale by use of a phase-shift analysis. Above this threshold, the angular distributions from 10 to 140 deg were fitted using the phase-shift technique, and the resulting integral cross sections were normalized to a semiempirically derived integral elastic cross section. Depending on the impact energy, the data are estimated to be accurate to within 5 to 9%.

Register, D. F.↗

Scattering of helium nozzle beams from LiF/001/ and NaCl/001/ crystal surfaces. I - Elastic and inelastic transitions

Nozzle-type atomic beams and time-of-flight detection methods are employed in studies of the scattering of thermal-energy He-4 atoms from LiF (001) and NaCl (001) surfaces under conditions where diffraction is observed and where substantial inelastic scattering occurs. Intensity and speed-distribution measurements are obtained for the portion of the scattering within the plane of incidence. For these measurements, incident-beam orientation with respect to target (polar angle and azimuth), incident-beam de Broglie wavelength (0.38-0.60 A), and crystal temperature (300-1000 K) are varied. For LiF, the measured intensity distributions exhibit sharp peaks comprised essentially of elastically scattered atoms and corresponding to up to third-order diffraction, inelastic scattering in the form of local dispersion about each of the elastic peaks, and a component of nominally diffuse scattering distributed below and between the peaks. For NaCl, the same general types of scattering are observed, with elastic scattering less prevalent, intensity peaks not as sharp, and dispersions of inelastic scattering harder to resolve.

Bledsoe, J. R.↗

Laboratory studies of atomic oxygen reactions with solids

Atomic beam experiments were performed to investigate the rate of atomic oxygen etching of carbon and polyimide films. The main emphasis of these experiments was on gaining an understanding of the role of atomic oxygen translational energy and substrate temperature in promoting the reactions. The experimental facility and techniques are described and results reviewed.

Arnold, Graham S.↗

Evaporative Cooling in a Holographic Atom Trap

We present progress on evaporative cooling of Rb-87 atoms in our Holographic Atom Trap (HAT). The HAT is formed by the interference of five intersecting YAG laser beams: atoms are loaded from a vapor-cell MOT into the bright fringes of the interference pattern through the dipole force. The interference pattern is composed of Talbot fringes along the direction of propagation of the YAG beams, prior to evaporative cooling each Talbot fringe contains 300,000 atoms at 50 micro-K and peak densities of 2 x 10(exp 14)/cu cm. Evaporative cooling is achieved through adiabatically decreasing the intensity of the YAG laser. We present data and calculations covering a range of HAT geometries and cooling procedures.

Newell, Raymond↗

The reaction efficiency of thermal energy oxygen atoms with polymeric materials

The reaction efficiency of several polymeric materials with thermal-energy (0.04 eV translational energy), ground-state (O3P) oxygen atoms was determined by exposing the materials to a room temperature gas containing a known concentration of atomic oxygen. The reaction efficiency measurements were conducted in two flowing afterglow systems of different configuration. Atomic oxygen concentration measurements, flow, transport and surface dose analysis is presented in this paper. The measured reaction efficiencies of Kapton, Mylar, polyethylene, D4-polyethylene and Tedlar are .001 to .0001 those determined with high-energy ground-state oxygen atoms in low earth orbit or in a high-velocity atom beam. D4-polyethylene exhibits a large kinetic isotope effect with atomic oxygen at thermal but not hyperthermal atom energies.

Koontz, S. L.↗

Low energy electron magnetometer using a monoenergetic electron beam

A low energy electron beam magnetometer utilizes near-monoenergetic electrons thereby reducing errors due to electron energy spread and electron nonuniform angular distribution. In a first embodiment, atoms in an atomic beam of an inert gas are excited to a Rydberg state and then electrons of near zero energy are detached from the Rydberg atoms. The near zero energy electrons are then accelerated by an electric field V(acc) to form the electron beam. In a second embodiment, a filament emits electrons into an electrostatic analyzer which selects electrons at a predetermined energy level within a very narrow range. These selected electrons make up the electron beam that is subjected to the magnetic field being measured.

Singh, J. J.↗