Langley facility for tests at Mach 7 of subscale, hydrogen-burning, airframe-integratable, scramjet models

Modifications to a 20-megawatt arc-heated facility for testing a hydrogen-burning, airframe-integratable, subscale, scramjet model are described. Arc-heated flow is mixed with unheated air to furnish a test flow duplicating Mach 7 flight. (Stagnation temperature is 2220 K.) Modifications to the commercially available heater to improve survivability and smoothness are described. Pitot profiles show uniform flow and a slightly thinner nozzle boundary layer than predicted. Comparison of the tunnel boundary layer, which will be ingested by the engine model, with the boundary layer that a flight engine might ingest from its vehicle forebody shows a difference in the density distribution through the boundary layer. Calculations of wall heating and transient wall temperatures of the engine model show that for a 30-sec burn, the heat sink model requires cooling at selected locations to avoid thermal-stress, cycle-life problems. Model performance predictions show that fuel equivalence ratio and nozzle exit area both have large effects on thrust. Average inlet entrance Mach number (as affected by boundary-layer ingestion) has little effect on thrust.

Boatright, W. B.↗

Analysis of the flow in a 1-MJ electric-arc shock tunnel

In the electric-arc-heated shock tunnel, the facility performance over a range of shock Mach numbers from 7 to 19 was evaluated. The efficiency of the arc-heated driver is deduced using an improved form of the shock tube equation. A theoretical and experimental analysis is made of the tailored-interface condition. The free stream properties in the test section, with nitrogen as the test gas, are evaluated using a method based on stagnation point, heat transfer measurements.

Reller, J. O., Jr.↗

Comparisons Between NO PLIF Imaging and CFD Simulations of Mixing Flowfields for High-Speed Fuel Injectors

The current work compares experimentally and computationally obtained nitric oxide (NO) planar laser-induced fluorescence (PLIF) images of the mixing flowfields for three types of high-speed fuel injectors: a strut, a ramp, and a rectangular flush-wall. These injection devices, which exhibited promising mixing performance at lower flight Mach numbers, are currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. The EIMP aims to investigate scramjet fuel injection and mixing physics, and improve the understanding of underlying physical processes relevant to flight Mach numbers greater than eight. In the experiments, conducted in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF), the injectors are placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number air flow at the entrance of a scramjet combustor. Helium is used as an inert substitute for hydrogen fuel. The PLIF is obtained by using a tunable laser to excite the NO, which is present in the AHSTF air as a direct result of arc-heating. Consequently, the absence of signal is an indication of pure helium (fuel). The PLIF images computed from the computational fluid dynamics (CFD) simulations are obtained by combining a fluorescence model for NO with the Reynolds-Averaged Simulation results carried out using the VULCAN-CFD solver to obtain a computational equivalent of the experimentally measured PLIF signal. The measured NO PLIF signal is mainly a function of NO concentration allowing for semi-quantitative comparisons between the CFD and the experiments. The PLIF signal intensity is also sensitive to pressure and temperature variations in the flow, allowing additional flow features to be identified and compared with the CFD. Good agreement between the PLIF and the CFD results provides increased confidence in the CFD simulations for investigations of injector performance.

Drozda, Tomasz, G.↗

Evaluation of dispersion strengthened nickel-base alloy heat shields for space shuttle application

The work reported constitutes the first phase of a two-phase program. Vehicle environments having critical effects on the thermal protection system are defined; TD Ni-20Cr material characteristics are reviewed and compared with TD Ni-20Cr produced in previous development efforts; cyclic load, temperature, and pressure effects on TD Ni-20Cr sheet material are investigated; the effects of braze reinforcement in improving the efficiency of spotwelded, diffusion-bonded, or seam-welded joints are evaluated through tests of simple lap-shear joint samples; parametric studies of metallic radiative thermal protection systems are reported; and the design, instrumentation, and testing of full-scale subsize heat shield panels are described. Tests of full-scale subsize panels included simulated meteoroid impact tests; simulated entry flight aerodynamic heating in an arc-heated plasma stream; programmed differential pressure loads and temperatures simulating mission conditions; and acoustic tests simulating sound levels experienced by heat shields during about boost flight. Test results are described, and the performances of two heat shield designs are compared and evaluated.

Johnson, R., Jr.↗

Scramjet testing from Mach 4 to 20 - Present capability and needs for the nineties

Consideration is given to the development of testing methods for the National Aerospace Plane (NASP) program, focusing on techniques for simulating and testing scramjet engines and scramjet engine components during flight from Mach 4 to Mach 20. The flight conditions associated with the NASP are outlined and the stagnation temperatures and pressures required to simulate flight up to orbital speeds are presented. The types of test facilities needed for scramjet propulsion testing are discussed, including combustion-heated facilities, electric arc-heated facilities, convection-heated facilities, shock tunnels, and expansion tubes. Issues related to assessing the flow quality in the scramjet ground testing facilities are examined, including uniformity, contamination, dissociation, ionization, nonequilibrium, and turbulence. Direct-connect combustor versus free-jet scramjet engine tests are compared and the capabilities of current and near-future scramjet engine test facilities are evaluated.

Thomas, Scott R.↗

Surface Catalysis and Oxidation on Stagnation Point Heat Flux Measurements in High Enthalpy Arc Jets

Heat flux sensors are routinely used in arc jet facilities to determine heat transfer rates from plasma plume. The goal of this study is to assess the impact of surface composition changes on these heat flux sensors. Surface compositions can change due to oxidation and material deposition from the arc jet. Systematic surface analyses of the sensors were conducted before and after exposure to plasma. Currently copper is commonly used as surface material. Other surface materials were studied including nickel, constantan gold, platinum and silicon dioxide. The surfaces were exposed to plasma between 0.3 seconds and 3 seconds. Surface changes due to oxidation as well as copper deposition from the arc jets were observed. Results from changes in measured heat flux as a function of surface catalycity is given, along with a first assessment of enthalpy for these measurements. The use of cupric oxide is recommended for future heat flux measurements, due to its consistent surface composition arc jets.

Nawaz, Anuscheh↗

The Laser Enhanced Arc-Jet Facility (LEAF-Lite): Simulating Convective and Radiative Heating with Arc-Jets and Multiple 50-KW CW Lasers

LEAF-Lite (Laser Enhanced Arc-Jet Facility) is a radiative laser heating facility that has been added to the 60 MW Interaction Heating Facility (IHF) convective plasma arc-jet located at NASA Ames Research Center. Together, these two systems can simulate both convective and radiative heating at heat fluxes reaching 551 W/cm2 by simultaneously combining a highest measured heat flux of 160 W/cm2 convective and 391 W/cm2 radiative heating on a 152-mm x 152-mm wedge model configuration. Adding radiant heating to an existing convective facility better simulates Earth atmospheric entry from hyperbolic lunarreturn speeds. The radiative heat is provided by multiple 50-kW CW IR lasers, which is nearly uniform across the illuminated surface with a total variation less than 6%, while the convective heat is provided by a high enthalpy plasma arc-jet. In a later phase, the facility will expand to test panel test articles of 432-mm x 432-mm and provide 100 W/cm2 of radiative heating in a plasma convective flow environment. The paper describes this new combined heating capability, its current testing conditions, and the unique application of the laser system with respect to the Orion test flight lunar orbits.

Cushman, Geoff↗

Electric arc heater is self starting

Remote method initiates an electric arc over a large range of gaps between two water-cooled electrodes of an arc-heated wind tunnel without disassembling the arc unit. This type of starting system can be used on both three-phase ac arc heaters and dc arc heaters.

Brown, R. D.↗

Radiative properties of a nickel based superalloy: Inconel 617 - After simulated earth reentry

Experimental results are presented to show the effect of environmental simulation exposures of convective heating and of radiant heating on the spectral (1.0 to 14 micrometers) and total emittance of oxidized Inconel 617. Convective heating exposures were conducted in an arc heated supersonic wind tunnel using a wedge-shaped specimen configuration. Radiant tests were conducted in dry air at a flow velocity of several meters per second. Convective heating specimens were subjected to 8, 20 and 38 heating cycles of 15-minutes duration and radiant heating specimens were tested for 10, 20, 50 and 100 one-half hour heating cycles. Changes in radiative properties are discussed in terms of changes in composition and morphology resulting from the exposure tests. Total normal emittance did not significantly change from the statically oxidized condition after either type of exposure, and it remained above 0.80 at 1260K for all cases. Although spectral changes were observed on post exposure specimens at wavelengths less than 2.0 micrometers and greater than 15 micrometers, these changes have no influence on total emittance at 1260K.

Cunnington, G. R.↗

Diode Laser Sensors for Arc-Jet Characterization

The development and application of tunable diode laser (TDL) absorption sensors to monitor the health and operating conditions in the large-scale 60 MW arc-heated- plasma wind-tunnel at NASA Ames Research Center is reported. The interactive heating facility (THF) produces re-entry flow conditions by expanding the gas heated in a constricted plasma arc-heater to flow at high velocity over a model located in a test cabin. This facility provides the conditions needed to test thermal protective systems for spacecraft re-entering the earth s atmosphere. TDL sensors are developed to monitor gas flows in both the high-temperature constricted flow and the supersonic expansion flow into test cabin. These sensors utilize wavelength-tuned diode lasers to measure absorption transitions of atomic oxygen near 777.2 nm, atomic nitrogen near 856.8 nm, and atomic copper near 793.3 nm. The oxygen and nitrogen sensors measure the population density in exited electronic states of these atoms. The measurements combined with the assumption of local thermal and chemical equilibrium yield gas temperature (typically near 7,000K). The nitrogen and oxygen population temperatures are redundant, and their close agreement provides an important test of the local thermal equilibrium assumption. These temperature sensors provide time-resolved monitors of the operating conditions of the arc-heater and can be used to verify and control the test conditions. An additional TDL sensor was developed to monitor the copper concentration in the arc-heater flow yielding values as high as 13 ppm. Measurements of copper in the flow can identify flow conditions with unacceptably rapid electrode erosion, and hence this sensor provides valuable information needed to schedule maintenance to avoid costly arc-heater failure. TDL sensors were also developed for measurements in the test cabin, where absorption measurements of the populations of argon and molecular nitrogen in excited metastable electronic states established that the number density of these excited species is much lower than estimated using frozen-chemistry approximations. This key finding suggests that in the post-expansion region there is not a significant energy sequestration in electronically excited species. Finally, TDL measurements of atomic potassium seeded into the test cabin flow were used to directly measure the static temperature of the test gas. The results of this study illustrate the high potential of time-resolved TDL measurements for routine and economical sensing of arc-heater health (gas temperature and electrode erosion) as well as the time-resolved test-cabin-flow conditions in front of the model.

Hanson, Ronald K.↗