Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ANOVA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Validation of Cardiovascular Parameters During NASA's Functional Task Test

Microgravity-induced physiological changes, including cardiovascular deconditioning may impair crewmembers f capabilities during exploration missions on the Moon and Mars. The Functional Task Test (FTT), which will be used to assess task performance in short and long duration astronauts, consists of 7 functional tests to evaluate crewmembers f ability to perform activities to be conducted in a partial-gravity environment or following an emergency landing on Earth. The Recovery from Fall/Stand Test (RFST) tests both the subject fs ability to get up from a prone position and orthostatic intolerance. PURPOSE: Crewmembers have never become presyncopal in the first 3 min of quiet stand, yet it is unknown whether 3 min is long enough to cause similar heart rate fluctuations to a 5-min stand. The purpose of this study was to validate and test the reliability of heart rate variability (HRV) analysis of a 3-min quiet stand. METHODS: To determine the validity of using 3 vs. 5-min of standing to assess HRV, 7 healthy subjects remained in a prone position for 2 min, stood up quickly and stood quietly for 6 min. ECG and continuous blood pressure data were recorded. Mean R-R interval and spectral HRV were measured in minutes 0-3 and 0-5 following the heart rate transient due to standing. Significant differences between the segments were determined by a paired t-test. To determine the reliability of the 3-min stand test, 13 healthy subjects completed 3 trials of the complete FTT on separate days, including the RFST with a 3-min stand test. Analysis of variance (ANOVA) was performed on the HRV measures. RESULTS: Spectral HRV measures reflecting autonomic activity were not different (p>0.05) during the 0-3 and 0-5 min segment (mean R-R interval: 738+/-74 ms, 728+/-69 ms; low frequency to high frequency ratio: 6.5+/-2.2, 7.7+/-2.7; normalized high frequency: 0.19+/-0.03, 0.18+/-0.04). The average coefficient of variation for mean R-R interval, systolic and diastolic blood pressures in the prone position and stand test were less than 8% for the test sessions. ANOVA results yielded a greater inter-subject variability (p.0.006) than inter-session variability (p>0.05) for HRV in the stand test. CONCLUSION: These studies show that a 3 minute stand delivers repeatable cardiovascular heart rate and BP data in the context of this larger series of tests such as the FTT.

Arzeno, N. M.↗

Validation of Cardiovascular Parameters during NASA's Functional Task Test

Microgravity exposure causes physiological deconditioning and impairs crewmember task performance. The Functional Task Test (FTT) is designed to correlate these physiological changes to performance in a series of operationally-relevant tasks. One of these, the Recovery from Fall/Stand Test (RFST), tests both the ability to recover from a prone position and cardiovascular responses to orthostasis. PURPOSE: Three minutes were chosen for the duration of this test, yet it is unknown if this is long enough to induce cardiovascular responses similar to the operational 5 min stand test. The purpose of this study was to determine the validity and reliability of heart rate variability (HRV) analysis of a 3 min stand and to examine the effect of spaceflight on these measures. METHODS: To determine the validity of using 3 vs. 5 min of standing to assess HRV, ECG was collected from 7 healthy subjects who participated in a 6 min RFST. Mean R-R interval (RR) and spectral HRV were measured in minutes 0-3 and 0-5 following the heart rate transient due to standing. Significant differences between the segments were determined by a paired t-test. To determine the reliability of the 3-min stand test, 13 healthy subjects completed 3 trials of the FTT on separate days, including the RFST with a 3 min stand. Analysis of variance (ANOVA) was performed on the HRV measures. One crewmember completed the FTT before a 14-day mission, on landing day (R+0) and one (R+1) day after returning to Earth. RESULTS VALIDITY: HRV measures reflecting autonomic activity were not significantly different during the 0-3 and 0-5 min segments. RELIABILITY: The average coefficient of variation for RR, systolic (SBP) and diastolic blood pressures during the RFST were less than 8% for the 3 sessions. ANOVA results yielded a greater inter-subject variability (p<0.006) than inter-session variability (p>0.05) for HRV in the RFST. SPACEFLIGHT: Lower RR and higher SBP were observed on R+0 in rest and stand. On R+1, both RR and SBP trended towards preflight rest and stand values. Postflight HRV showed higher LF/HF for rest and stand and lower HFnu during rest. CONCLUSION: These studies show that a 3 min stand delivers repeatable HRV data in the context of this larger series of FTT tests. Spaceflight-induced changes in blood pressure, RR and autonomic function (HRV) are evident from the RFST.

Arzeno, N. M.↗

Finite Element Model Calibration Approach for Ares I-X

Ares I-X is a pathfinder vehicle concept under development by NASA to demonstrate a new class of launch vehicles. Although this vehicle is essentially a shell of what the Ares I vehicle will be, efforts are underway to model and calibrate the analytical models before its maiden flight. Work reported in this document will summarize the model calibration approach used including uncertainty quantification of vehicle responses and the use of nonconventional boundary conditions during component testing. Since finite element modeling is the primary modeling tool, the calibration process uses these models, often developed by different groups, to assess model deficiencies and to update parameters to reconcile test with predictions. Data for two major component tests and the flight vehicle are presented along with the calibration results. For calibration, sensitivity analysis is conducted using Analysis of Variance (ANOVA). To reduce the computational burden associated with ANOVA calculations, response surface models are used in lieu of computationally intensive finite element solutions. From the sensitivity studies, parameter importance is assessed as a function of frequency. In addition, the work presents an approach to evaluate the probability that a parameter set exists to reconcile test with analysis. Comparisons of pre-test predictions of frequency response uncertainty bounds with measured data, results from the variance-based sensitivity analysis, and results from component test models with calibrated boundary stiffness models are all presented.

Horta, Lucas G.↗

Finite Element Model Calibration Approach for Area I-X

Ares I-X is a pathfinder vehicle concept under development by NASA to demonstrate a new class of launch vehicles. Although this vehicle is essentially a shell of what the Ares I vehicle will be, efforts are underway to model and calibrate the analytical models before its maiden flight. Work reported in this document will summarize the model calibration approach used including uncertainty quantification of vehicle responses and the use of non-conventional boundary conditions during component testing. Since finite element modeling is the primary modeling tool, the calibration process uses these models, often developed by different groups, to assess model deficiencies and to update parameters to reconcile test with predictions. Data for two major component tests and the flight vehicle are presented along with the calibration results. For calibration, sensitivity analysis is conducted using Analysis of Variance (ANOVA). To reduce the computational burden associated with ANOVA calculations, response surface models are used in lieu of computationally intensive finite element solutions. From the sensitivity studies, parameter importance is assessed as a function of frequency. In addition, the work presents an approach to evaluate the probability that a parameter set exists to reconcile test with analysis. Comparisons of pretest predictions of frequency response uncertainty bounds with measured data, results from the variance-based sensitivity analysis, and results from component test models with calibrated boundary stiffness models are all presented.

Horta, Lucas G.↗

On-Orbit Prospective Echocardiography on International Space Station Crew

Introduction A prospective trial of echocardiography was conducted on of six crewmembers onboard the International Space Station. The main objective was to determine the efficacy of remotely guided tele-echocardiography, including just-in-time e-training methods and determine what "space normal" echocardiographic data is. Methods Each crewmember operator (n=6) had 2-hour preflight training. Baseline echocardiographic data were collected 55 to 167days preflight. Similar equipment was used in each 60-minute in-flight session (mean microgravity exposure - 114 days (34 -- 190)). On Orbit ultrasound operators used an e-learning system within 24h of these sessions. Expert assistance was provided using ultrasound video downlink and two-way voice. Testing was repeated 5 to 16 days after landing. Separate ANOVA was used on each echocardiographic variable (n=33). Within each ANOVA, three tests were made: a) effect of mission phase (preflight, in-flight, post flight); b) effect of echo technician (two technicians independently analyzed the data); c) interaction between mission phase and technician. Results Nine rejections of the null hypothesis (mission phase or technician or both had no effect) were discovered and considered for follow up. Of these, six rejections were for significant technician effects, not as a result of space flight. Three rejections of the null hypothesis (Aortic Valve time velocity integral, Mitral E wave Velocity and heart rate) were attributable to space flight, however determined not to be clinically significant. No rejections were due to the interaction between technician and space flight. Conclusion No consistent clinically significant effects of long-duration space flight were seen in echocardiographic variables of the given group of subjects.

Hamilton, Douglas R.↗

SMAR Sessions

This slide presentation is a series of educational presentations that are on the statistical function of analysis of variance (ANOVA). Analysis of Variance (ANOVA) examines variability between groups, relative to within groups, to determine whether there's evidence that the groups are not from the same population. One other presentation reviews hypothesis testing.

Ploutz-Snyder, Robert↗

Direct Relationship Between Perceptual and Motor Variability

The time that elapses between stimulus onset and the onset of a saccadic eye movement is longer and more variable than can be explained by neural transmission times and synaptic delays (Carpenter, 1981, in: Eye Movements: Cognition & Visual Perception, Earlbaum). In theory, noise underlying response-time (RT) variability could arise at any point along the sensorimotor cascade, from sensory noise arising Vvithin the early visual processing shared Vvith perception to noise in the motor criterion or commands necessary to trigger movements. These two loci for internal noise can be distinguished empirically; sensory internal noise predicts that response time Vvill correlate Vvith perceived stimulus magnitude whereas motor internal noise predicts no such correlation. Methods. We used the data described by Liston and Stone (2008, JNS 28:13866-13875), in which subjects performed a 2AFC saccadic brightness discrimination task and the perceived brightness of the chosen stimulus was then quantified in a second 21FC perceptual task. Results. We binned each subject's data into quartiles for both signal strength (from dimmest to brightest) and RT (from slowest to fastest) and analyzed the trends in perceived brightness. We found significant effects of both signal strength (as expected) and RT on normalized perceived brightness (both p less than 0.0001, 2-way ANOVA), without significant interaction (p = 0.95, 2-way ANOVA). A plot of normalized perceived brightness versus normalized RT show's that more than half of the variance was shared (r2 = 0.56, P less than 0.0001). To rule out any possibility that some signal-strength related artifact was generating this effect, we ran a control analysis on pairs of trials with repeated presentations of identical stimuli and found that stimuli are perceived to be brighter on trials with faster saccades (p less than 0.001, paired t-test across subjects). Conclusion. These data show that shared early visual internal noise jitters perceived brightness and the saccadic motor output in parallel. While the present correlation could theoretically result, either directly or indirectly, from some low-level brainstem or retinal mechanism (e.g., arousal, pupil size, photoreceptor noise) that influences both visual and oculomotor circuits, this is unlikely given the earlier fin ding that the variability in perceived motion direction and smooth-pursuit motor output is highly correlated (Stone and Krauzlis, 2003, JOV 3:725-736), suggesting that cortical circuits contribute to the shared internal noise.

Liston, Dorion B.↗

Overexpression of Catalase in Mitochondria Mitigates the Effects of Simulated Microgravity and Social Isolation on Cytokine Expression in Mouse Hippocampus

Space flight missions are becoming longer and more common and evidence points to the physiological toll the missions have on the human body. Aging, sedentary lifestyle, and spaceflight have similar degenerative effects on almost every part of our body; both exposure to the space environment and aging result in cardiovascular deconditioning, bone loss, muscle atrophy, brain changes, and immune response impairment. We hypothesize that exposure to the space environment generates excessive Reactive Oxygen Species (ROS), which results in neuroinflammation and aging-like degenerative symptoms in the brain. We used the hindlimb unloading (HU) model to mimic microgravity with either paired or single housed animals (social isolation). Responses to 30d (30 days) of HU were compared in wildtype or transgenic MCAT (Mitochondrial-targeted CATalase) mice, in which mitochondrial ROS is quenched by over-expression of human catalase. Expression of 4-Hydroxynonenal (4HNE) and Park7 (redox-sensitive chaperone and sensor of oxidative stress) were measured by ELISA (Enzyme-Linked ImmunoSorbent Assay), a protein array quantified from the hippocampal cytokines and 8-hydroxy-2'-deoxyguanosine in serum was measured by ELISA to assess oxidative DNA damage. Preliminary analysis of cage behavior patterns from video collected at the end of the study showed that MCAT HU mice (socially housed) were more active and conducted more exploratory activities compared to NL (Normally Loaded). Our biochemical results showed simulated microgravity and/or social isolation caused changes in levels of cytokines related to immune responses. Two-way ANOVA (Analysis of Variance) revealed significant interaction effects of HU and genotype in expression levels of five cytokines (out of 35) in socially-housed animals. Elevation of these generally pro-inflammatory cytokines by HU in WT (Wild Type) mice was mitigated in MCAT mice, suggesting a role for mitochondrial ROS signaling in inflammatory CNS (Central Nervous System) responses to microgravity. Interestingly, some of these cytokines in the hippocampus displayed strong correlations to the 4HNE levels. We also found substantive cytokine responses to social isolation in the hippocampus; housing and genotype interaction effects were significant (by 2-Factor ANOVA) for 15 cytokines, most of which were mitigated in MCAT mice.Taken together, our results showed that both simulated microgravity and social isolation influenced cytokine levels in the hippocampus and MCAT mice were at least partially protected from these changes. These findings implicate a potentially important role for mitochondrial ROS in CNS responses to the challenges posed by long duration spaceflight.

MCAT↗

Fractal Analysis of Radiologists Visual Scanning Pattern in Screening Mammography

Several investigators have investigated radiologists visual scanning patterns with respect to features such as total time examining a case, time to initially hit true lesions, number of hits, etc. The purpose of this study was to examine the complexity of the radiologists visual scanning pattern when viewing 4-view mammographic cases, as they typically do in clinical practice. Gaze data were collected from 10 readers (3 breast imaging experts and 7 radiology residents) while reviewing 100 screening mammograms (24 normal, 26 benign, 50 malignant). The radiologists scanpaths across the 4 mammographic views were mapped to a single 2-D image plane. Then, fractal analysis was applied on the derived scanpaths using the box counting method. For each case, the complexity of each radiologist s scanpath was estimated using fractal dimension. The association between gaze complexity, case pathology, case density, and radiologist experience was evaluated using 3 factor fixed effects ANOVA. ANOVA showed that case pathology, breast density, and experience level are all independent predictors of the visual scanning pattern complexity. Visual scanning patterns are significantly different for benign and malignant cases than for normal cases as well as when breast parenchyma density changes.

fractal analysis↗

DIFFERENTIAL CANID PREDATION OF TRANSLOCATED JUVENILE DESERT TORTOISES AND CHEMICAL SIGNATURE DIFFERENCES BETWEEN FEMALE AND MALE ADULT AND JUVENILE DESERT TORTOISES

Differential predation was observed in a population of 59 translocated juvenile Desert Tortoises (Gopherus agassizii) of known sex during a juvenile translocation survival study between September 2012 and November 2017. The main source of mortality (77%; 24 of 31 deaths) was attributed to Coyote (Canis latrans) and Kit Fox (Vulpes macrotis) predation. Predation was skewed with 71% (n = 17) female mortality versus 29% (n = 7) male mortality. We tested the hypothesis that juvenile females smell different than males which leads to increased canid predation. We also explored differences in chemical signatures of resident adult female and male Desert Tortoises. We collected oral, cloacal and chin/forelimb swabs from translocated juvenile and resident adult female and male tortoises during fall 2015 and fall 2017 and analyzed them using headspace gas chromatography/mass spectrometry to determine potential differences in the chemical signatures among the four groups. Standardized chromatographic peak responses were subjected to repeated analyses of variance (ANOVA). For development of artificial scents, mean responses were calculated for each juvenile tortoise from standardized responses representing all collections (i.e., oral, cloacal, and chin/forelimb swabs) and grand means were determined for males and females. Repeated measures ANOVAs clearly demonstrated that the collections of volatiles differed according to age and/or sex depending on the body location of collection. Among the plausibly endogenous volatiles that differed by age, many of them are alcohols. Two field trials using captive Coyotes and one field trial partially within the translocation area were conducted to test if Coyotes showed a preference for female or bias against male synthesized scent. No consistent preference or bias was shown, suggesting that no innate preference for female odor was evident.

60 APPLIED LIFE SCIENCES↗

On-Site Pilot Study - Removal of Uranium, Radium-226 and Arsenic from Impacted Leachate by Reverse Osmosis - 13155

Conestoga-Rovers and Associates (CRA-LTD) performed an on-site pilot study at the Welcome Waste Management Facility in Port Hope, Ontario, Canada, to evaluate the effectiveness of a unique leachate treatment process for the removal of radioactive contaminants from leachate impacted by low-level radioactive waste. Results from the study also provided the parameters needed for the design of the CRA-LTD full scale leachate treatment process design. The final effluent water quality discharged from the process to meet the local surface water discharge criteria. A statistical software package was utilized to obtain the analysis of variance (ANOVA) for the results from design of experiment applied to determine the effect of the evaluated factors on the measured responses. The factors considered in the study were: percent of reverse osmosis permeate water recovery, influent coagulant dosage, and influent total dissolved solids (TDS) dosage. The measured responses evaluated were: operating time, average specific flux, and rejection of radioactive contaminants along with other elements. The ANOVA for the design of experiment results revealed that the operating time is affected by the percent water recovery to be achieved and the flocculant dosage over the range studied. The average specific flux and rejection for the radioactive contaminants were not affected by the factors evaluated over the range studied. The 3 month long on-site pilot testing on the impacted leachate revealed that the CRA-LTD leachate treatment process was robust and produced an effluent water quality that met the surface water discharge criteria mandated by the Canadian Nuclear Safety Commission and the local municipality. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Image Characterization of Reactions Generated by an Aeroengine Micromixing Injector for Lean Direct Injection of Hydrogen and Hydrogen/Natural Gas Blend

An aeroengine micromixing injector, originally designed for lean direct injection of jet fuel, was adapted to work with hydrogen, natural gas, and any blend in between. The ultimate goal of the design was to achieve low NOx emissions when operated on pure hydrogen; to better characterize its performance, flame imaging diagnostics was implemented. Three types of cameras mounted parallel to the injector base and pointing towards the quartz combustor cylinder with the same angle were operated simultaneously: Nikon D90, Dynacolor FB-N9-U, and Phantom v7.1, to capture the visible spectrum, OH* chemiluminescence, and dynamic behavior of the flames, respectively. The current work also includes the overlapping of visible spectrum and OH* chemiluminescence, as an effort to qualitatively define the heat release over the flame area, i.e., UV over visible domain. Additionally, a z-type schlieren configuration was employed to reinforce the presence of some small-scale details occurring near the injector outlet ports. Using the airbox pressure drop, preheat temperature, fuel composition and flame temperature as the factors of study, a Box Behnken model was designed yielding into a 16-points matrix for the operability region, at atmospheric pressure. The main responses were extracted from the OH* images, because of its correlation with the flame heat release, these being the flame area and its average brightness, the heat release area and its center of gravity and leading edge. To assess the importance of the main factors and their interactions, an analysis of variance (ANOVA) was performed for each response, considering as significant each contributor with a p-value below 0.05. For these five responses it was found that all four main factors need to be included into the model (most of them because its own significance, others to ensure the model hierarchy), as well as some common interactions as the preheat and flame temperatures or pressure drop and fuel composition, and quadratic terms from fuel composition or flame temperature. Three of the five models presented R2 and coefficient of variance (C.V.) indicators around 0.97 and 5%, respectively; the leading edge ANOVA yielded into R2=0.78 and C.V.=18.88%; and the heat release area showed R2=0.91 and C.V.=24.13%. Lastly, the confinement ratio effect of the combustor over the flame structure was quantified, for three different conditions: the original 80 mm inner diameter and 200 mm length cylinder was compared against a shorter 150 mm tube (same inner diameter) and a narrower 47 mm inner diameter one (same 200 mm length). The length had a smaller effect than the inner diameter, even though both factors were not strong enough to make a significant deviation on most of the flame parameters: the difference was within the repeatability margin of error for the brightness, flame area, and center of gravity and leading edge of the heat release area.

Imaging diagnostics, flame characterization, OH* c↗

Absorption dissymmetry factor enhancement: A data-driven approach to unravel the synthesis knobs of chiral 2D perovskites

Chiral 2D metal halide perovskites (MHPs) are promising for spin-optoelectronic applications, yet their absorption dissymmetry factor (g abs ) exhibits significant variability due to complex, co-dependent structural and experimental factors. Here, we established a data-driven framework using Pearson’s correlation, ANOVA, and Gaussian process regression to identify and model key synthesis “knobs” governing these properties. The analysis revealed that solvent choice is the primary factor driving variability. For acetonitrile-based films, g abs was maximized by optimizing annealing temperature and film thickness. Conversely, films from higher boiling point solvents showed complex dependencies on annealing temperature, excitonic integral intensity, and film texture. These statistical correlations provide a roadmap for the rational design of high-performance chiral MHPs and establish a foundation for future machine learning-driven material exploration.

ANOVA↗

Upscaling Uncertainty with Dynamic Discrepancy for a Multi-Scale Carbon Capture System

Uncertainties from model parameters and model discrepancy from small-scale models impact the accuracy and reliability of predictions of large-scale systems. Inadequate representation of these uncertainties may result in inaccurate and overconfident predictions during scale-up to larger systems. Hence, multiscale modeling efforts must accurately quantify the effect of the propagation of uncertainties during upscaling. Using a Bayesian approach, we calibrate a small-scale solid sorbent model to thermogravimetric (TGA) data on a functional profile using chemistry-based priors. Crucial to this effort is the representation of model discrepancy, which uses a Bayesian smoothing splines (BSS-ANOVA) framework. Our uncertainty quantification (UQ) approach could be considered intrusive as it includes the discrepancy function within the chemical rate expressions; resulting in a set of stochastic differential equations. Such an approach allows for easily propagating uncertainty by propagating the joint model parameter and discrepancy posterior into the larger-scale system of rate expressions. In conclusion, the broad UQ framework presented here could be applicable to virtually all areas of science where multiscale modeling is used. Supplementary materials for this article are available online.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synchrotron-Based Micro-CT Imaging of the Human Lung Acinus

Structural data about the human lung fine structure are mainly based on stereological methods applied to serial sections. As these methods utilize 2D images, which are often not contiguous, they suffer from inaccuracies which are overcome by analysis of 3D micro-CT images of the never-sectioned specimen. The purpose of our study was to generate a complete data set of the intact three-dimensional architecture of the human acinus using high-resolution synchrotron-based micro-CT (synMCT). A human lung was inflation-fixed by formaldehyde ventilation and then scanned in a 64-slice CT over its apex to base extent. Lung samples (8-mm diameter, 10-mm height, N = 12) were punched out, stained with osmium tetroxide, and scanned using synMCT at (4 {micro}m){sup 3} voxel size. The lung functional unit (acinus, N = 8) was segmented from the 3D tomographic image using an automated tree-analysis software program. Morphometric data of the lung were analyzed by ANOVA. Intra-acinar airways branching occurred over 11 generations. The mean acinar volume was 131.3 {+-} 29.2 mm{sup 3} (range, 92.5-171.3 mm{sup 3}) and the mean acinar surface was calculated with 1012 {+-} 26 cm{sup 2}. The airway internal diameter (starting from the bronchiolus terminalis) decreases distally from 0.66 {+-} 0.04 mm to 0.34 {+-} 0.06 mm (P < 0.001) and remains constant after the seventh generation (P < 0.5). The length of each generation ranges between 0.52 and 0.93 mm and did not show significant differences between the second and eleventh generation. The branching angle between daughter branches varies between 113-degree and 134-degree without significant differences between the generations (P < 0.3). This study demonstrates the feasibility of quantitating the 3D structure of the human acinus at the spatial resolution readily achievable using synMCT.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of Diffusion Time on Short-Range Hyperpolarized 3He Diffusivity Measurements in Emphysema

Purpose: To characterize the effect of diffusion time on short-range hyperpolarized 3He MR diffusion measurements across a wide range of emphysema severity. Materials and Methods: 3He diffusion MR imaging was performed on 19 lungs or lobes resected from 18 subjects with varying degrees of emphysema using 3 diffusion times (1.6 msec, 5 msec, and 10 msec) at constant b value. Emphysema severity was quantified as the mean apparent diffusion coefficient (ADC) and as the percentage of pixels with ADC higher than multiple thresholds from 0.30-0.55 cm2/sec (ADC index). Quantitative histology (mean linear intercept) was obtained in 10 of the lung specimens from 10 of the subjects. Results: The mean ADCs with diffusion times of 1.6, 5.0, and 10.0 msec were 0.46, 0.40, and 0.37 cm2/sec, respectively (P <0.0001, ANOVA). There was no relationship between the ADC magnitude and the effect of diffusion time on ADC values. Mean linear intercept correlated with ADC (r=0.91-0.94, P<0.001) and ADC index (r=0.78-0.92, P<0.01) at all diffusion times.

60 APPLIED LIFE SCIENCES↗

Fractal Analysis of Visual Search Activity for Mass Detection During Mammographic Screening

Purpose: The objective of this study was to assess the complexity of human visual search activity during mammographic screening using fractal analysis and to investigate its relationship with case and reader characteristics. Methods: The study was performed for the task of mammographic screening with simultaneous viewing of four coordinated breast views as typically done in clinical practice. Eye-tracking data and diagnostic decisions collected for 100 mammographic cases (25 normal, 25 benign, 50 malignant) and 10 readers (three board certified radiologists and seven radiology residents), formed the corpus data for this study. The fractal dimension of the readers’ visual scanning patterns was computed with the Minkowski–Bouligand box-counting method and used as a measure of gaze complexity. Individual factor and group-based interaction ANOVA analysis was performed to study the association between fractal dimension, case pathology, breast density, and reader experience level. The consistency of the observed trends depending on gaze data representation was also examined. Results: Case pathology, breast density, reader experience level, and individual reader differences are all independent predictors of the visual scanning pattern complexity when screening for breast cancer. No higher order effects were found to be significant. Conclusions: Fractal characterization of visual search behavior during mammographic screening is dependent on case properties and image reader characteristics.

47 OTHER INSTRUMENTATION↗

A multi‐variable framework for selecting WRF physics configurations at convection‐permitting scales: An Amazon wet‐season case study

Tropical convection over rainforests modulates atmospheric circulation and the energy and hydrological cycles across multiple scales. However, the scarcity of observations still limits our understanding of these processes. Although numerical models are utilized to investigate atmospheric physical processes, their performance depends on the choice of parameterizations and grid resolution. Here, in this work, we introduce and apply a multi‐variable, multi‐physics framework to evaluate and rank the Advanced Research Weather Research and Forecasting (WRF–ARW) configurations at 1‐km resolution over the central Amazon during the wet season. A 48‐member ensemble combines three land‐surface models (LSMs), four planetary boundary layer (PBL), and four microphysics (MP) schemes. Model performance for seven convection‐related near‐surface and boundary‐layer variables is assessed using Taylor diagrams and the Taylor skill score (TSS), analysis of variance (ANOVA)‐based sensitivity metrics, and non‐parametric rank tests. We then construct a combined, weighted TSS to identify configurations that are comparatively robust across variables. Results showed that most configurations reproduce near‐surface temperature, sensible and latent heat fluxes, and boundary‐layer height reasonably well, whereas humidity and rainfall remain challenging. LSM choice has the strongest impact on the surface fluxes and a secondary influence on near‐surface temperature and humidity, PBL schemes dominate boundary‐layer height, and MP schemes exert the largest control on rainfall. No single configuration is optimal for all variables, but the combination of Noah (LSM), Yonsei University (PBL), and Morrison (MP) emerges as the most robust configuration for this case, with the WRF single‐moment six‐class scheme (WSM6) providing a competitive, computationally cheaper MP alternative. The framework is general and can be applied to other regions, seasons, and convective regimes.

Amazon rainforest↗