Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

SOLAR MODULATION OF THE LOCAL INTERSTELLAR SPECTRUM WITH VOYAGER 1 , AMS-02, PAMELA , AND BESS

In recent years, the increasing precision of direct cosmic rays measurements opened the door to high-sensitivity indirect searches of dark matter and to more accurate predictions for radiation doses received by astronauts and electronics in space. The key ingredients in the study of these phenomena are the knowledge of the local interstellar spectrum (LIS) of galactic cosmic rays and the understanding of how the solar modulation affects the LIS inside the heliosphere. Voyager 1 , AMS-02, PAMELA , and BESS measurements of proton and helium fluxes provide valuable information, allowing us to shed light on the shape of the LIS and the details of the solar modulation during solar cycles 22-24. A new parametrization of the LIS is presented, based on the latest data from Voyager 1 and AMS-02. Using the framework of the force-field approximation, the solar modulation parameter is extracted from the time-dependent fluxes measured by PAMELA and BESS . A modified version of the force-field approximation with a rigidity-dependent modulation parameter is introduced, yielding better fits than the force-field approximation. The results are compared with the modulation parameter inferred by neutron monitors.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraints on Leptophilic Dark Matter from the AMS-02 Experiment

The annihilation of dark matter particles in the Galactic halo of the Milky Way may lead to cosmic ray signatures that can be probed by the AMS-02 experiment, which has measured the composition and fluxes of charged cosmic rays with unprecedented precision. Given the absence of characteristic spectral features in the electron and positron fluxes measured by AMS-02, we derive upper limits on the dark matter annihilation cross section for leptophilic dark matter models. Our limits are based on a new background model that describes all recent measurements of the energy spectra of cosmic-ray positrons and electrons. For thermal dark matter relics, we can exclude dark matter masses below about 100 GeV. We include the radiation of electroweak gauge bosons in the dark matter annihilation process and compute the antiproton signal that can be expected within leptophilic dark matter models.

79 ASTRONOMY AND ASTROPHYSICS↗

Angle Measurement System (AMS) for Establishing Model Pitch and Roll Zero, and Performing Single Axis Angle Comparisons

The angle measurement system (AMS) developed at NASA Langley Research Center (LaRC) is a system for many uses. It was originally developed to check taper fits in the wind tunnel model support system. The system was further developed to measure simultaneous pitch and roll angles using 3 orthogonally mounted accelerometers (3-axis). This 3-axis arrangement is used as a transfer standard from the calibration standard to the wind tunnel facility. It is generally used to establish model pitch and roll zero and performs the in-situ calibration on model attitude devices. The AMS originally used a laptop computer running DOS based software but has recently been upgraded to operate in a windows environment. Other improvements have also been made to the software to enhance its accuracy and add features. This paper will discuss the accuracy and calibration methodologies used in this system and some of the features that have contributed to its popularity.

Crawford, Bradley L.↗

Impact of AMS-02 Measurements on Reducing GCR Model Uncertainties

For vehicle design, shield optimization, mission planning, and astronaut risk assessment, the exposure from galactic cosmic rays (GCR) poses a significant and complex problem both in low Earth orbit and in deep space. To address this problem, various computational tools have been developed to quantify the exposure and risk in a wide range of scenarios. Generally, the tool used to describe the ambient GCR environment provides the input into subsequent computational tools and is therefore a critical component of end-to-end procedures. Over the past few years, several researchers have independently and very carefully compared some of the widely used GCR models to more rigorously characterize model differences and quantify uncertainties. All of the GCR models studied rely heavily on calibrating to available near-Earth measurements of GCR particle energy spectra, typically over restricted energy regions and short time periods. In this work, we first review recent sensitivity studies quantifying the ions and energies in the ambient GCR environment of greatest importance to exposure quantities behind shielding. Currently available measurements used to calibrate and validate GCR models are also summarized within this context. It is shown that the AMS-II measurements will fill a critically important gap in the measurement database. The emergence of AMS-II measurements also provides a unique opportunity to validate existing models against measurements that were not used to calibrate free parameters in the empirical descriptions. Discussion is given regarding rigorous approaches to implement the independent validation efforts, followed by recalibration of empirical parameters.

Slaba, T. C.↗

Comparison of Space Radiation GCR Models to Recent AMS Data

This paper is the third in a series of comparisons of American (NASA) and Russian (ROSCOSMOS) space radiation calculations. The present work focuses on calculation of fluxes of galactic cosmic rays (GCR), which are a constant source of radiation that constitutes one of the major hazards during deep space exploration missions for both astronauts/cosmonauts and hardware. In this work, commonly used GCR models are compared with recently published measurements of cosmic ray Hydrogen, Helium, and the Boron-to-Carbon ratio from the Alpha Magnetic Spectrometer (AMS). All of the models were developed and calibrated prior to the publication of the AMS data, therefore this an opportunity to validate the models against an independent data set.

John W. Norbury↗

AMS History from 1950 to 2020

Presentation illustrates over 60 years of aerial measurements and establishment of Aerial Measuring System asset by the DOE. The presentation will be used as part of the training new AMS personnel. Presentation illustrates over 60 years of aerial measurements and establishment of Aerial Measuring System asset by the DOE. The presentation will be used as part of the training new AMS personnel.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Electrodeposition as an alternate method for preparation of environmental samples for iodide by AMS

This paper presents an evaluation of an alternate method for preparing environmental samples for 129 I analysis by accelerator mass spectrometry (AMS) at Idaho National Laboratory. The optimal sample preparation method is characterized by ease of preparation, capability of processing very small quantities of iodide, and ease of loading into a cathode. Electrodeposition of iodide on a silver wire was evaluated using these criteria. This study indicates that the electrochemically-formed silver iodide deposits produce ion currents similar to those from precipitated silver iodide for the same sample mass. Furthermore, precipitated silver iodide samples are usually mixed with niobium or silver powder prior to loading in a cathode. Using electrodeposition, the silver is already mixed with the sample and can simply be picked up with tweezers, placed in the sample die, and pressed into a cathode. The major advantage of this method is that the silver wire/electrodeposited silver iodide is much easier to load into a cathode.

129I↗

Conversion of the LLNL/CAMS 1 MV biomedical AMS system to a semi-automated natural abundance 14C spectrometer: system optimization and performance evaluation

The Lawrence Livermore National Laboratory – Center for Accelerator Mass Spectrometry compact 1 MV biomedical accelerator mass spectrometer was repurposed and optimized for the semi-automated radiocarbon measurement of natural abundance environmental samples. Here we present results from 15 months of routine system operation and evaluate the system performance based on 30 sample wheels measured with consistent operating conditions over 7 months from August 2019 to March 2020. Additionally, the average measurement precision was 2.7 ± 0.7‰. System accuracy was assessed with measurements of 14 C-free materials, standard materials with 14 C-content spanning 0.5 to 1.5 F 14 C, and by comparison to split samples measured with the 10 MV AMS system. Overall, this system can routinely measure samples as small as 300 µgC and less than 33000 years without the need for size-specific correction protocols.

43 PARTICLE ACCELERATORS↗

AMS / BARC Joint Survey (Summary Report)

Report describes a series of joint aerial radiation survey flights at various locations in Southern Nevada and Colorado performed by AMS and BARC (U.S. and India). The flights were conducted over areas of well-characterized natural background in Nevada, at the Large-Area Calibration Pads at Grand Junction, CO, and over real ground contamination at the Nevada National Security Site. The intention of the joint surveys was to compare the responses, processes, and procedures of each country’s aerial radiation detection system. These systems can detect and map ground contamination that may result from a nuclear or radiological accident or incident, and play a significant role in the national radiological emergency response capabilities of both countries.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

AMS Joint/Bilateral Surveys

A historical presentation depicting the International Joint Aerial Surveys AMS has co-created and collaborative efforts that were implemented as result of those efforts.

61 RADIATION PROTECTION AND DOSIMETRY↗

An Improved Method for Extracting, Sorting, and AMS Dating of Pollen Concentrates From Lake Sediment

High-resolution chronologies are crucial for paleoenvironmental reconstructions, and are particularly challenging for lacustrine records of terrestrial paleoclimate. Accelerator Mass Spectrometry (AMS) radiocarbon measurement of terrestrial macrofossils is the most common technique for building age models for lake sediment cores, but relies on the presence of terrestrial macrofossils in sediments. In the absence of sufficient macrofossils, pollen concentrates represent a valuable source of dates for building high-resolution chronologies. However, pollen isolation and dating may present several challenges, as has been reported by different authors in previous work over the last few decades. Here we present an improved method for extracting, purifying and radiocarbon-dating pollen concentrates using flow cytometry to improve the extraction efficiency and the purity of the pollen concentrates. Overall, the nature of the sediments and the abundance of the pollen represent major considerations in obtaining enough pollen grains and, consequently, enough carbon to be dated. Further, the complete separation of pollen from other forms of organic matter is required to ensure the accuracy of the dates. We apply the method to surface samples and sediment cores recovered from two contrasting lake basins on the eastern side of the Sierra Nevada (California), and describe the variations that may be used to optimize pollen preparation from a variety of sediments.

58 GEOSCIENCES↗

Soot Particle Aerosol Mass Spectrometer (SP-AMS) BBOP

We collected rapid (1 second time response) measurements of aerosol chemical composition (ug/m3) of biomass burning plumes (including wild fires and controlled agricultural burns) sampled on the DOE G1 aircraft during the 2013 Biomass Burning Observation Project (BBOP) using the Soot Particle Aerosol Mass Spectrometer (SP-AMS) developed and deployed by Aerodyne Research, Inc.

54 ENVIRONMENTAL SCIENCES↗

International-Aerial Measuring System (I-AMS) Training Program

Since the Fukushima reactor accident in 2011, there has been an increased interest worldwide in developing national capabilities to rapidly map and assess ground contamination resulting from nuclear reactor accidents. The capability to rapidly measure the size of the contaminated area, determine the activity level, and identify the radionuclides can aid emergency managers and decision makers in providing timely protective action recommendations to the public and first responders. The development of an aerial detection capability requires interagency coordination to assemble the radiation experts, detection system operators, and aviation aircrews to conduct the aerial measurements, analyze and interpret the data, and provide technical assessments. The Office of International Emergency Management and Cooperation (IEMC) at the U.S. Department of Energy, National Nuclear Security Administration (DOE/NNSA) sponsors an International - Aerial Measuring System (I-AMS) training program for partner nations to develop and enhance their response to radiological emergencies. An initial series of courses can be conducted in the host country to assist in developing an aerial detection capability. As the capability develops and expands, additional experience can be gained through advanced courses with the opportunity to conduct aerial missions over a broad range of radiation environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Trials and tribulations in the first three years in operation of the SSAMS for biomedical 14 C-AMS at LLNL

We report on the first several years of operation of our recently installed 250 kV SSAMS at LLNL, purchased to replace our 1-MV AMS system for the measurement of 14 C from labeled biochemical samples. We have modified the ion source region to improve ion output. Additionally, the SSAMS required significant software modifications to the data acquisition system in order to accurately measure 14 C at the high-count rates typically encountered with labeled biochemical samples. Here, we found that the data can be corrected assuming a nonparalyzable dead time response with a single event dead time of 6 µs. Since operation began, we have measured over 13,000 graphitic unknowns and over 1900 standards with an overall precision of 1.0%. We have optimized our system for the analysis of CO 2 gas samples. We compared aliquots of identical samples measured as solid graphite and as liquid drops. Excellent agreement was found between the two, although the average precision of the graphite targets was an order of magnitude better than the liquid drop analysis due to the much larger number of 14 C atoms available for measurement.

42 ENGINEERING↗