Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “61 RADIATION PROTECTION AND DOSIMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Godiva-IV Dosimetry Exercise 2022 (IER-538 CED4A Report)

This report presents the final results of IER 538, The International Nuclear Accident Dosimeter (NAD) Intercomparison Exercise with Godiva-IV. The purpose of the exercise, held in August of 2022, was to test participants’ NADs and dosimetry personnel to the dose estimation requirements established by ANSI/HPS-N13.3 Dosimetry for Criticality Accidents and DOE-STD-1098-2017, Radiological Control. Two prompt critical bursts of the Godiva critical assembly were used to simulate criticality accidents, and NADs from participating laboratories were placed at known locations around Godiva, mounted on either BOttle Manikin ABsorptions (BOMABs) phantoms (to simulate doses received by people) or plates (to simulate doses in free air). Similar exercises have been held in 2016 and 2018 using National Criticality Experiments Research Center’s (NCERC’s) Flattop and Godiva assemblies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview

From the countless critical experiments performed in the world during the past century, high-quality integral benchmarks experiments have been collected and gathered into the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook), managed by the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Working Group. This information preservation and dissemination effort is crucial for reactor licensing as well as criticality and radiation transport modeling validation. This summary reports on the status of a tentative benchmark addition to the ICSBEP Handbook. The proposed benchmark arises from legacy operation data of the Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR). The HPRR was a small, unmoderated, unshielded fast burst reactor that was used for research in health physics and radiobiology as well as teaching and training. As part of a comprehensive investigation of the available HPRR operation data and characteristics, different possibilities for use of the valuable results were studied. A critical experiment benchmark evaluation was performed, analyzing data coming from sub-critical and critical operation of the HPRR during operator training, steady-state irradiation of samples and before critical bursts. The results of the evaluation do not satisfy for the ICSBEP standards as the benchmark relative standard uncertainty is of about 4% for k eff , and the relative difference between sample calculations and expected k eff results is of about 1.5%. Due to those unsatisfactory results, it was decided not to pursue critical experiments evaluation of the HPRR presently and to focus instead on shielding type data for the creation of a criticality accident alarm system (CAAS) and shielding category benchmark, which is currently very scarce in the ICSBEP handbook—especially concerning critical, pulsed assembly, or reactor operation data. Several dosimetry and shielding experiments from HPRR burst operation were evaluated, with different benchmark metrics as sulfur fluence, Element 57 dose, or neutron fluence at different distances and under different shield materials conditions. An evaluation focusing on the Element 57 neutron dose as a benchmark metric was submitted to the ICSBEP Technical Review Group (TRG) meeting in October 2021, and the inclusion of the evaluation in the ICSBEP Handbook was deferred. The main change proposed by the international experiment evaluation experts is to use the neutron fluence measured by Bonner spheres as a benchmark metric. This represents a quantity closer to that actually measured by the experimentalists of the HPRR compared to the Element 57 dose, which adds another step of data transformation, thus potentially adding uncertainty to the benchmark. The evaluation has been updated and will be submitted to the 2022 ICSBEP TRG meeting for inclusion in the 2023 edition of the ICSBEP Handbook. The evaluation is performed using the KENO and MAVRIC combination from the SCALE 6.2.4 code suite which was previously used in similar CAAS benchmarks to allow for the use of variance reduction techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

Long-term, non-invasive FTIR detection of low-dose ionizing radiation exposure

Non-invasive methods of detecting radiation exposure show promise to improve upon current approaches to biological dosimetry in ease, speed, and accuracy. Here we developed a pipeline that employs Fourier transform infrared (FTIR) spectroscopy in the mid-infrared spectrum to identify a signature of low dose ionizing radiation exposure in mouse ear pinnae over time. Mice exposed to 0.1 to 2 Gy total body irradiation were repeatedly measured by FTIR at the stratum corneum of the ear pinnae. We found significant discriminative power for all doses and time-points out to 90 days after exposure. Classification accuracy was maximized when testing 14 days after exposure (specificity > 0.9 with a sensitivity threshold of 0.9) and dropped by roughly 30% sensitivity at 90 days. Infrared frequencies point towards biological changes in DNA conformation, lipid oxidation and accumulation and shifts in protein secondary structure. Since only hundreds of samples were used to learn the highly discriminative signature, developing human-relevant diagnostic capabilities is likely feasible and this non-invasive procedure points toward rapid, non-invasive, and reagent-free biodosimetry applications at population scales.

61 RADIATION PROTECTION AND DOSIMETRY↗

Luminescence dosimetry for evaluation of the external exposure in Metlino, upper Techa River valley, Southern Urals, Russia: Analysis of new results

Luminescence dosimetry was applied in the former settlement of Metlino, Southern Urals, Russia as part of a full-scale study to validate the Techa River Dosimetry System (TRDS) 2016 for the upper Techa River region. The village, which was evacuated in 1956, was located 7 km downstream of the release point of liquid radioactive waste by the Mayak plutonium facility. Several brick samples were taken from north-eastern and south-eastern walls of the granary, facing the former Techa river shoreline and floodplain. Samples were all taken at the same height and measured at different depths into the brick. For the majority of brick samples, good Optically Stimulated Luminescence properties of the quartz grains were observed. In some cases, however, strong levels of sensitization and/or signal recuperation were encountered which necessitated adjustment in the measurement protocols. Anthropogenic doses in bricks varied from 1.5 to 6.6 Gy and the horizontal profiles along both walls showed significant variation, which is explained on a qualitative basis. Further, a dose depth profile is observed for selected samples, which is different from the dose depth profile measured and simulated for samples from the north-western wall of the granary in previous studies. This is qualitatively explained by the differences in source configuration.

61 RADIATION PROTECTION AND DOSIMETRY↗

Methods of improving brain dose estimates for internally deposited radionuclides *

The US National Council on Radiation Protection and Measurements (NCRP) convened Scientific Committee 6–12 (SC 6–12) to examine methods for improving dose estimates for brain tissue for internally deposited radionuclides, with emphasis on alpha emitters. This Memorandum summarises the main findings of SC 6–12 described in the recently published NCRP Commentary No. 31, ‘Development of Kinetic and Anatomical Models for Brain Dosimetry for Internally Deposited Radionuclides’. The Commentary examines the extent to which dose estimates for the brain could be improved through increased realism in the biokinetic and dosimetric models currently used in radiation protection and epidemiology. A limitation of most of the current element-specific systemic biokinetic models is the absence of brain as an explicitly identified source region with its unique rate(s) of exchange of the element with blood. The brain is usually included in a large source region called Other that contains all tissues not considered major repositories for the element. In effect, all tissues in Other are assigned a common set of exchange rates with blood. A limitation of current dosimetric models for internal emitters is that activity in the brain is treated as a well-mixed pool, although more sophisticated models allowing consideration of different activity concentrations in different regions of the brain have been proposed. Here case studies for 18 internal emitters indicate that brain dose estimates using current dosimetric models may change substantially (by a factor of 5 or more), or may change only modestly, by addition of a sub-model of the brain in the biokinetic model, with transfer rates based on results of published biokinetic studies and autopsy data for the element of interest. As a starting place for improving brain dose estimates, development of biokinetic models with explicit sub-models of the brain (when sufficient biokinetic data are available) is underway for radionuclides frequently encountered in radiation epidemiology. A longer-term goal is development of coordinated biokinetic and dosimetric models that address the distribution of major radioelements among radiosensitive brain tissues.

61 RADIATION PROTECTION AND DOSIMETRY↗

IER-484 CED3b Report: AFRRI ER1 Dosimetry Characterization

This report presents the preliminary work for IER 484, the characterization of the leakage radia tion field from the TRIGA reactor at the Armed Forces Radiobiology Research Institute (AFRRI). The purpose of the dose characterization is to establish the reference dose needed to execute a NAD inter-comparison exercise. During the week of August 20th, a team from Lawrence Livermore National Laboratory (LLNL), Sandia National Laboratory (SNL), and Institut de Radioprotection et de Sûreté Nucléaire (IRSN) performed various measurements in AFRRI’s TRIGA ER1 (Exposure Room 1) with Passive Neutron Spectrometer (PNS) spheres and nuclear accident dosimeters (NADs) mounted on Bottle Manikin Absorption (BOMAB) phantoms (to simulate doses received by people) and additional NADs mounted on aluminum plates (to simulate doses in free air). Without Atomic Weapons Establishment (AWE), LLNL became responsible for measuring the neutron spectrum using PNS spheres. SNL is responsible for providing photon dose data. LLNL, SNL, and IRSN each deployed their own NADs, which will be compared to the reference dose measured. Final characterization of the dose field based on analyzed data will be presented in the CED4a report.

42 ENGINEERING↗

Dose estimates and their uncertainties for use in epidemiological studies of radiation-exposed populations in the Russian Southern Urals

Many residents of the Russian Southern Urals were exposed to radioactive environmental pollution created by the operations of the Mayak Production Association in the mid- 20 th century. There were two major releases: the discharge of about 1x10 17 Bq of liquid waste into the Techa River between 1949 and 1959; and the atmospheric release of 7.4 * 10 16 Bq as a result an explosion in the radioactive waste-storage facility in 1957. The releases into the Techa River resulted in the exposure of more than 30,000 people who lived in riverside villages between 1950 and 1961. The 1957 accident contaminated a larger area with the highest exposure levels in an area that is called the East Urals Radioactive Trace (EURT). Current epidemiologic studies of the exposed populations are based on dose estimates obtained using a Monte-Carlo dosimetry system (TRDS-2016MC) that provides multiple realizations of the annual doses for each cohort member. These dose realizations provide a central estimate of the individual dose and information on the uncertainty of these dose estimates. In addition, the correlation of individual annual doses over realizations provides important information on shared uncertainties that can be used to assess the impact of shared dose uncertainties on risk estimate uncertainty.This paper considers dose uncertainties in the TRDS-2016MC. Individual doses from external and internal radiation sources were reconstructed for 48,036 people based on environmental contamination patterns, residential histories, individual 90 Sr body-burden measurements and dietary intakes. Dietary intake of 90 Sr resulted in doses accumulated in active bone marrow (or simply, marrow) that were an order of magnitude greater than those in soft tissues. About 84% of the marrow dose and 50% of the stomach dose was associated with internal exposures. The lognormal distribution is well-fitted to the individual dose realizations, which, therefore, could be expressed and easily operated in terms of geometric mean (GM) and geometric standard deviation (GSD). Cohort average GM for marrow and stomach cumulative doses are 0.21 and 0.03 Gy, respectively. Cohort average dose uncertainties in terms of GSD are as follows: for marrow it is 2.93 (90%CI: 2.02–4.34); for stomach and the other non-calcified tissues it is 2.32 (90% CI: 1.78–2.9).

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose conversion factors for absorbed dose in a mobile phone to absorbed dose in critical organs in an anthropomorphic phantom for emergency dosimetry applications: OSL and TL experimental results, and Monte Carlo simulations

Here, an anthropomorphic phantom was equipped with three smartphones and irradiated in five separate exposure geometries in air using a 137 Cs source. The phantom was fitted internally with thermoluminescence dosimeters (TLD-700 chips) to measure the absorbed dose to the individual organs, while the absorbed doses in the phones were evaluated using optically stimulated luminescence (OSL) from the phones’ surface mount resistors (SMRs), along with reference dosimeters, namely Luxel OSL films and TLD-700 chips. The results indicate a strong dependence on the phone location with respect to the source due to shielding and scattering from the body. Dose conversion factors were calculated for several plausible exposure scenarios in order to correlate the absorbed doses measured in the phones to the average body dose received by the phantom. The measured conversion factors were compared with calculated factors using MCNP6.2 Monte Carlo simulations and an ADAM voxel phantom. Experiments were conducted to assess how the phone orientation and angle impacts the dose received by the phone components. The overall results indicate that the doses measured can vary significantly depending upon exposure geometry (including phone position and angle). However, in rotational irradiation symmetry, the phone doses lead to an over-estimate of the average whole-body dose by an average of ~10%, independent of the phone locations tested in this study. This result, if confirmed in future studies, may be acceptable for triage.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray Inspection Model Validation with Physical Dosimetry

A non-functional printed circuit board assembly was developed using ULTIboard and a simple computational transport model was created for use with the Monte Carlo software MCNP. EBT 3 film radiography was used to compare with Monte Carlo simulation to validate the board representation. The computational transport model was then revised to include connection pins, solder balls, highly attenuating internal structures, and copper trace distribution. Results from the revised model were compared to the EBT 3 films to observe improvements to dose profiles. It was found that this method was useful in verifying the placement of components, as the dose profiles were observed to follow the same trends. The experiment was then repeated using XRQA 2 films to achieve the same level of contrast with 1% the dose of EBT 3 films. It was found that high contrast may be achieved using these films to identify major issues with the model geometry, at a cost of dose profile accuracy. A second validation method was applied to the model using 37 CaF 2 thermoluminescent dosimeters (TLDs). TLD measurements were compared with the simplified and complex transport models to identify the features that have the greatest impact on simulation accuracy. The TLD calibration to CaF 2 was found to be accurate within 5.6%, while calibration to dose in Si was found to be accurate within 4.7%. Finally, it was observed that the accurate representation of solder balls and proper modeling of highly attenuating internal structures had the greatest impact on simulation accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Long-Term Quality Control Data for a 137 Cs Dosimetry Calibration Source

Strict quality assurance programs are required for many radiological applications, but these seldom exist for verifying dosimetry calibration sources. After initial characterization of a dosimetry calibration facility, quality control procedures are recommended to ensure the early detection of any changes or malfunctions. These also result in refined knowledge about average dose rate and experimental variations in dose delivery. This paper describes the implementation of a phase I quality control protocol for a 137 Cs dosimetry calibration source and includes an analysis of the resulting data collected over a 24-mo period. During this time, substantial data was collected to establish trial control limits. Air kerma rate measurements were obtained using an ion chamber and were adjusted for decay, corrected for ambient temperature, pressure and humidity, and then analyzed using quality control charts. Three variations of rational subgrouping methods were used in order to find assignable causes of error, and Nelson's Rules were followed to detect any non-random statistical variations. Measurements were subgrouped according to same-day measurements in order to detect positional errors as well as atmospheric correction errors. Additionally, measurements were subgrouped according to analogous experimental setups in order to detect failure in equipment or incorrect settings. Both were analyzed using the X-bar and R chart method. Similarly, individuals and moving ranges charts were used to carefully examine each position in order to observe any situational errors that may occur which include timing, positional, or interference errors. Each method was successful in identifying unique out-of-control data points that occurred during the phase I application of forming control limits. Furthermore, over the 24-mo period, enough data points were deemed in-control to establish reliable trial limits. Future experiments will include the phase II application of gaining more reliable measurements in order to fine-tune the limits, as well as performing a designed experiment, where variables are purposefully changed in order to test the variation of the data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Updated Results of the Nuclear Accident Dosimetry Intercomparison at the Armed Forces Radiobiology Research Institute’s TRIGA Reactor (IER-602 CED-4a Report)

The IER-602 3b document (Angus, et al. 2024) reported the initial, 24-hour results of the international nuclear accident intercomparison, which took place at the Armed Forces Radiobiological Research Institute during June 24-28, 2024. This report provides updated results and further analysis of the intercomparison.

61 RADIATION PROTECTION AND DOSIMETRY↗

Decision-making Framework to Support the End-of-Life Management of High-Activity Radioactive Sources

Sealed radioactive sources are used for an extremely wide range of purposes, including as radiation sources in various nuclear facilities, universities, hospitals, biomedical and industrial applications, as well as for geological prospecting and exploration. The proper management of these sealed radioactive sources once they have reached their end-of-life is still a global challenge. Very few field-tested Mobile Hot Cells (MHC) exist in the world to support the end-of-life management of disused high-activity radioactive sources. One of the critical challenges that a source recovery team encounters on each site is to find adequate space, and access to that space to complete the staging and recapture process with a MHC; this process is tedious, uncertain, and time-consuming. Therefore, it is essential to understand the planning and management of the MHC setup and takedown. Currently, there isn't an single capable planning tool that will provide an effective medium to plan, inform, educate, and communicate knowledge about the environment where the MHC will be deployed. We present a novel approach for the planning and management of the deployment of the MHC to several different sites that relies on technology. Furthermore, this planning tool will support collaboration, promote information sharing, and foster better decision making processes, resulting in a more efficient, and reliable setup and source recovery with the MHC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Public Health Response and Medical Management of Internal Contamination in Past Radiological or Nuclear Incidents: A Review

Following a radiological or nuclear emergency, workers, responders and the public may be internally contaminated with radionuclides. Screening, monitoring and assessing any internal contamination and providing necessary medical treatment, especially when a large number of individuals are involved, is challenging. Experience gained and lessons learned from the management of previous incidents would help to identify gaps in knowledge and capabilities on preparedness for and response to radiation emergencies. In this paper, eight largescale and five workplace radiological and nuclear incidents are reviewed cross 14 technical areas, under the broader topics of emergency preparedness, emergency response and recovery processes. The review findings suggest that 1) new strategies, algorithms and technologies are explored for rapid screening of large populations; 2) exposure assessment and dose estimation in emergency response and dose reconstruction in recovery process are supported by complementary sources of information, including ‘citizen science’; 3) surge capacity for monitoring and dose assessment is coordinated through national and international laboratory networks; 4) evidence-based guidelines for medical management and follow-up of internal contamination are urgently needed; 5) mechanisms for international and regional access to medical countermeasures are investigated and implemented; 6) long-term health and medical follow up programs are designed and justified; and 7) capabilities and capacity developed for emergency response are sustained through adequate resource allocation, routine nonemergency use of technical skills in regular exercises, training, and continuous improvement.

61 RADIATION PROTECTION AND DOSIMETRY↗

Iron-rich microstructure records of high temperature multi-component silicate melt behavior in nuclear fallout

Above-ground nuclear explosions that interact with the surface of the earth entrain materials from the surrounding environment, influencing the resulting physical and chemical evolution of the fireball, which can affect the final chemical phase and mobility of hazardous radionuclides that are dispersed in the environment as fallout particles. The interaction of iron with a nuclear explosion is of specific interest due to the potential for iron to act as a redox buffer and because of the likelihood of significant masses of metals to be present in urban environments. We investigated fallout from a historic surface interacting nuclear explosion conducted on a steel tower and report the discovery of widespread and diverse iron-rich micro-structures preserved within the samples, including crystalline dendrites and micron-scale iron-rich spheres with liquid immiscibility textures. We assert these micro-structures reflect local redox conditions and cooling rates and can inform interpretation of high temperature events, enabling new insights into fireball condensation physics and chemistry when metals from the local environment (i.e. structural steel) are vaporized or entrained. Finally, these observations also significantly expand the availability of silicate immiscibility datasets applicable to rapidly quenched systems such as meteorite impact melt glass.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Spatial and temporal prediction of radiation dose rates near Fukushima Daiichi Nuclear Power Plant

In this paper, we have developed a methodology to estimate the spatiotemporal distribution of radiation air dose rates around the Fukushima Daiichi Nuclear Power Plant (FDNPP). In our exploratory data analysis, we found that (1) the temporal evolution of dose rates is composed of a log-linear decay trend and fluctuations of air dose rates that are spatially correlated among adjacent monitoring posts; and (2) the slope of the log-linear environmental decay trend can be represented as a function of the apparent initial dose rates, coordinate position, land-use type, and soil type. From these observations, we first estimated the log-linear decay trend at each location based on these predictors, using the random forest method. We then developed a modified Kalman filter coupled with a Gaussian process model to estimate the dose-rate time series at a given location and time. We applied this method to the Fukushima evacuation zone (as of March 2017), which included 17 monitoring post locations (with monitoring datasets collected between 2014 and 2018) and generated a time series of dose-rate maps. Our results show that this approach allows us to produce accurate spatial and temporal predictions of radiation dose-rate maps using limited spatiotemporal measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Conditional Point Sampling: A Monte Carlo Method for Radiation Transport in Stochastic Media.

Current methods for stochastic media transport are either computationally expensive or, by nature, approximate. Moreover, none of the well-developed, benchmarked approximate methods can compute the variance caused by the stochastic mixing, a quantity especially important to safety calculations. Therefore, we derive and apply a new conditional probability function (CPF) for use in the recently developed stochastic media transport algorithm Conditional Point Sampling (CoPS), which 1) leverages the full intra-particle memory of CoPS to yield errorless computation of stochastic media outputs in 1D, binary, Markovian-mixed media, and 2) leverages the full inter-particle memory of CoPS and the recently developed Embedded Variance Deconvolution method to yield computation of the variance in transport outputs caused by stochastic material mixing. Numerical results demonstrate errorless stochastic media transport as compared to reference benchmark solutions with the new CPF for this class of stochastic mixing as well as the ability to compute the variance caused by the stochastic mixing via CoPS. Using previously derived, non-errorless CPFs, CoPS is further found to be more accurate than the atomic mix approximation, Chord Length Sampling (CLS), and most of memory-enhanced versions of CLS surveyed. In addition, we study the compounding behavior of CPF error as a function of cohort size (where a cohort is a group of histories that share intra-particle memory) and recommend that small cohorts be used when computing the variance in transport outputs caused by stochastic mixing.

61 RADIATION PROTECTION AND DOSIMETRY↗

Deep Learning enabled spectral energy conversion for in situ exposure measurements

A detector-specific deep learning (DL) approach is presented for spectra-to-exposure conversion using large-format sodium iodide (NaI(Tl)) detectors deployed for in situ environmental radiation measurements in emergency response scenarios. Accurate determination of exposure from NaI spectra is challenging due to poor energy resolution, partial energy absorption, and the strong sensitivity of traditionally deployed analytical conversion methods to calibrated source geometry and pre-deployment assumptions. Here, to address these limitations, a multi-layer perceptron model was trained on a hybrid in situ /Monte Carlo dataset constructed to span a broad range of photon energies, spatial extents, and realistic deployment variability, representative of general in situ emergency response conditions. The DL model was evaluated against commonly fielded analytical approaches under matched simulation conditions, including a single-factor method, a G-function method, and a modeled pressurized ion chamber (PIC) baseline. This study was intentionally computational in scope to enable controlled, like-for-like comparisons between conversion techniques while minimizing confounding real-world variability. Comparison to the modeled PIC provides contextual benchmarking and is not intended as a field inter-comparison with deployed instruments. Across the evaluated 20 keV to 3 MeV energy range, the DL approach consistently exhibited higher accuracy and reduced variance relative to the analytical methods against a deterministically calculated exposure. This may indicate improved robustness to spectral complexity without reliance on source-, geometric-, or spectral region-specific optimization. While results do not represent real-world validation, the presented work demonstrates that deep learning may effectively learn the nonlinear detector response-to-exposure relationship for asymmetric NaI(Tl) detectors and offers a promising pathway for improving in situ exposure estimation using spectroscopic systems already integrated into initial real-time emergency response operations.

61 RADIATION PROTECTION AND DOSIMETRY↗