Analysis of autogenous shrinkage-induced microcracks in concrete from 3D images

A new image analysis procedure for quantifying microcracks from three-dimensional (3D) X-ray microCT images of concrete is presented. The method separates microcracks from air voids and aggregates by combining filtering and morphological operations. It was applied to study the effects of supplementary cementitious materials (SCMs) and curing age on autogenous shrinkage-induced microcracks in low w/b ratio concretes, and to determine the representative elementary volume (REV) for various properties of microcracks and air voids. Results showed that slag and silica fume significantly increased autogenous shrinkage and related microcracking. These SCMs increased volume fraction, width, length, dendritic density, anisotropy, and connectivity of microcracks, but decreased specific surface and tortuosity. Similar trends were observed with age. Comparison between 3D and 2D measurements was made. REV analysis showed that a sampling volume of ~20 × 20 × 25 mm{sup 3} is sufficient for characterising most parameters of autogenous shrinkage microcracks and air voids in concrete.

36 MATERIALS SCIENCE↗

X-ray microscopy enables multiscale high-resolution 3D imaging of plant cells, tissues, and organs

Capturing complete internal anatomies of plant organs and tissues within their relevant morphological context remains a key challenge in plant science. While plant growth and development are inherently multiscale, conventional light, fluorescence, and electron microscopy platforms are typically limited to imaging of plant microstructure from small flat samples that lack a direct spatial context to, and represent only a small portion of, the relevant plant macrostructures. We demonstrate technical advances with a lab-based X-ray microscope (XRM) that bridge the imaging gap by providing multiscale high-resolution three-dimensional (3D) volumes of intact plant samples from the cell to the whole plant level. Serial imaging of a single sample is shown to provide sub-micron 3D volumes co-registered with lower magnification scans for explicit contextual reference. High-quality 3D volume data from our enhanced methods facilitate sophisticated and effective computational segmentation. Advances in sample preparation make multimodal correlative imaging workflows possible, where a single resin-embedded plant sample is scanned via XRM to generate a 3D cell-level map, and then used to identify and zoom in on sub-cellular regions of interest for high-resolution scanning electron microscopy. In total, we present the methodologies for use of XRM in the multiscale and multimodal analysis of 3D plant features using numerous economically and scientifically important plant systems.

59 BASIC BIOLOGICAL SCIENCES↗

In situ high-temperature 3D imaging of the damage evolution in a SiC nuclear fuel cladding material

Silicon carbide (SiC)-based nuclear fission fuel rod cladding has been considered as one of the possible designs for accident tolerant fuels. It is in the form of a SiC fibre reinforced SiC matrix composite tube (SiC f -SiC m ) with monolithic SiC outer and/or inner coating layers. This study focuses on the deformation and fracture processes in this material using in situ X-ray micro-computed tomography (XCT) at room temperature (RT) and 1200 °C in an inert gas environment in a C-ring compression loading configuration. Prior to testing, local properties and residual stresses were characterised using nanoindentation and Raman spectroscopy since they can impact the mechanical behaviour of the material. The 3D strain distribution, crack formation and propagation processes including the toughening mechanisms (e.g., crack deflection, micro-cracking, crack bridging and bifurcation) are investigated in the coating and underlying composites at RT and 1200 °C. There is no particular sequence which toughening mechanism occurs first – this is very different from the conventional toughening theory in ceramic-matrix composites under uniaxial tension loading. Indeed, no evidence of fibre pull-out or fibre fracture was observed in this SiC f -SiC m nuclear cladding material in the current C-ring compression configuration. The correlation between local measurements and bulk mechanical behaviour are discussed.

3D imaging↗

Anatomy of an agricultural antagonist: Feeding complex structure and function of three xylem sap‐feeding insects illuminated with synchrotron‐based 3D imaging

Abstract Many insects feed on xylem or phloem sap of vascular plants. Although physical damage to the plant is minimal, the process of insect feeding can transmit lethal viruses and bacterial pathogens. Disparities between insect‐mediated pathogen transmission efficiency have been identified among xylem sap‐feeding insects; however, the mechanistic drivers of these trends are unclear. Identifying and understanding the structural factors and associated integrated functional components that may ultimately determine these disparities are critical for managing plant diseases. Here, we applied synchrotron‐based X‐ray microcomputed tomography to digitally reconstruct the morphology of three xylem sap‐feeding insect vectors of plant pathogens: Graphocephala atropunctata (blue‐green sharpshooter; Hemiptera, Cicadellidae) and Homalodisca vitripennis (glassy‐winged sharpshooter; Hemiptera, Cicadellidae), and the spittlebug Philaenus spumarius (meadow spittlebug; Hemiptera, Aphrophoridae). The application of this technique revealed previously undescribed anatomical features of these organisms, such as key components of the salivary complex. The visualization of the 3D structure of the precibarial valve led to new insights into the mechanism of how this structure functions. Morphological disparities with functional implications between taxa were highlighted as well, including the morphology and volume of the cibarial dilator musculature responsible for extracting xylem sap, which has implications for force application capabilities. These morphological insights will be used to target analyses illuminating functional differences in feeding behavior.

3D imaging↗

Robust initialization of 2D-3D image registration using the projection-slice theorem and phase correlation

Purpose: The image registration literature comprises many methods for 2D-3D registration for which accuracy has been established in a variety of applications. However, clinical application is limited by a small capture range. Initial offsets outside the capture range of a registration method will not converge to a successful registration. Previously reported capture ranges, defined as the 95% success range, are in the order of 4-11 mm mean target registration error. In this article, a relatively computationally inexpensive and robust estimation method is proposed with the objective to enlarge the capture range. Methods: The method uses the projection-slice theorem in combination with phase correlation in order to estimate the transform parameters, which provides an initialization of the subsequent registration procedure. Results: The feasibility of the method was evaluated by experiments using digitally reconstructed radiographs generated from in vivo 3D-RX data. With these experiments it was shown that the projection-slice theorem provides successful estimates of the rotational transform parameters for perspective projections and in case of translational offsets. The method was further tested on ex vivo ovine x-ray data. In 95% of the cases, the method yielded successful estimates for initial mean target registration errors up to 19.5 mm. Finally, the method was evaluated as an initialization method for an intensity-based 2D-3D registration method. The uninitialized and initialized registration experiments had success rates of 28.8% and 68.6%, respectively. Conclusions: The authors have shown that the initialization method based on the projection-slice theorem and phase correlation yields adequate initializations for existing registration methods, thereby substantially enlarging the capture range of these methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microstructure reconstruction of battery polymer separators by fusing 2D and 3D image data for transport property analysis

A new approach to generate high-fidelity 3D microstructure reconstructions by leveraging resolution and sample volume characteristics from 2D and 3D microscopy methods is presented here. This approach is employed to model the microstructure of a highly orthotropic polypropylene separator used in lithium-ion batteries, which have challenging multi-scale features of fibrils (<100 nm) and lamellae (>100 nm) to resolve in 3D. Phase contrast nano X-ray computed tomographic data are used to reconstruct the lamellae phase, while 2D scanning electron microscopy data are used to characterize sub-100 nm microstructure features such as the thin fibrils that are beyond the effective resolution of X-ray computed tomography. Fibril geometries are reconstructed stochastically based on the 2D higher resolution data, and integrated with the lamellae geometries in 3D space. Transport property analyses are performed to investigate the bias of microstructure models without considering the fibrils. A sensitivity study is also conducted to facilitate understanding of the relationship between microstructure characteristics and transport properties.

25 ENERGY STORAGE↗

GENFIRE: A generalized Fourier iterative reconstruction algorithm for high-resolution 3D imaging

Tomography has made a radical impact on diverse fields ranging from the study of 3D atomic arrangements in matter to the study of human health in medicine. Despite its very diverse applications, the core of tomography remains the same, that is, a mathematical method must be implemented to reconstruct the 3D structure of an object from a number of 2D projections. Here, we present the mathematical implementation of a tomographic algorithm, termed GENeralized Fourier Iterative REconstruction (GENFIRE), for high-resolution 3D reconstruction from a limited number of 2D projections. GENFIRE first assembles a 3D Fourier grid with oversampling and then iterates between real and reciprocal space to search for a global solution that is concurrently consistent with the measured data and general physical constraints. The algorithm requires minimal human intervention and also incorporates angular refinement to reduce the tilt angle error. We demonstrate that GENFIRE can produce superior results relative to several other popular tomographic reconstruction techniques through numerical simulations and by experimentally reconstructing the 3D structure of a porous material and a frozen-hydrated marine cyanobacterium. As a result, equipped with a graphical user interface, GENFIRE is freely available from our website and is expected to find broad applications across different disciplines.

36 MATERIALS SCIENCE↗

Utah FORGE: Seismic DAS and Geophone Borehole Data Processing and 3D Imaging of Vp/Vs Ratio in the 2024 Stimulated Reservoir

This dataset includes a final report and a 3D velocity model derived from seismic DAS and geophone borehole data collected during the April 2024 stimulation of the reservoir at Utah FORGE. The report details the processing of over 50,000 P- and S-wave travel times used in a tomographic inversion to estimate the Vp/Vs ratio, revealing anomalies adjacent to wells 16A and 16B that may be associated with injected fracturing fluids. Additionally, Wadati analysis of more than 27,000 pairs of differential P- and S-wave travel times supports this interpretation with a high Vp/Vs estimate of 1.86, averaged over the dimensions of the earthquake cluster. The accompanying data file provides a 3D model of P- and S-wave velocities and Vp/Vs ratios, structured with spatial coordinates and velocity values.

15 GEOTHERMAL ENERGY↗

Gas-mapping 3D imager measurement techniques and method of data processing

Measurement approaches and data analysis methods are disclosed for combining 3D topographic data with spatially-registered gas concentration data to increase the efficiency of gas monitoring and leak detection tasks. Here, the metric for efficiency is defined as reducing the measurement time required to achieve the detection, or non-detection, of a gas leak with a desired confidence level. Methods are presented for localizing and quantifying detected gas leaks. Particular attention is paid to the combination of 3D spatial data with path-integrated gas concentration measurements acquired using remote gas sensing technologies, as this data can be used to determine the path-averaged gas concentration between the sensor and points in the measurement scene. Path-averaged gas concentration data is useful for finding and quantifying localized regions of elevated (or anomalous) gas concentration making it ideal for a variety of applications including: oil and gas pipeline monitoring, facility leak and emissions monitoring, and environmental monitoring.

Thorpe, Michael↗

3D Imaging of Geothermal Faults from a Vertical DAS Fiber at Brady Hot Spring, NV USA

In March 2016, arguably the most ambitious 4D (3D space + over time) active-source seismic survey for geothermal exploration in the U.S. was acquired at Brady Natural Laboratory, outside Fernley, Nevada. The four-week experiment included 191 vibroseis source locations, and approximately 130 m of distributed acoustic sensing (DAS) in a vertical well, located at the southern end of the survey area. The imaging of the geothermal faults is done with reverse time migration of the DAS data for both P-P and P-S events in order to generate 3D models of reflectivity, which can identify subsurface fault locations. Three scenarios of receiver data are explored to investigate the reliability of the reflectivity models obtained: (1) Migration of synthetic P-P and P-S DAS data, (2) migration of the observed field DAS data and (3) migration of pure random noise to better assess the validity of our results. The comparisons of the 3D reflectivity models from these three scenarios confirm that sections of three known faults at Brady produce reflected energy observed by the DAS. Two faults that are imaged are ~1 km away from the DAS well; one of these faults (middle west-dipping) is well-constructed for over 400 m along the fault’s strike, and 300 m in depth. These results confirm that the DAS data, together with an imaging engine such as reverse time migration, can be used to position important geothermal features such as faults.

10 SYNTHETIC FUELS↗

3D imaging of magnetic domains in Nd 2 Fe 14 B using scanning hard X-ray nanotomography

Nanoscale structural and electronic heterogeneities are prevalent in condensed matter physics. Investigating these heterogeneities in 3D has become an important task for understanding material properties. To provide a tool to unravel the connection between nanoscale heterogeneity and macroscopic emergent properties in magnetic materials, scanning transmission X-ray microscopy (STXM) is combined with X-ray magnetic circular dichroism. A vector tomography algorithm has been developed to reconstruct the full 3D magnetic vector field without any prior noise assumptions or knowledge about the sample. Two tomographic scans around the vertical axis are acquired on single-crystalline Nd 2 Fe 14 B pillars tilted at two different angles, with 2D STXM projections recorded using a focused 120 nm X-ray beam with left and right circular polarization. Image alignment and iterative registration have been implemented based on the 2D STXM projections for the two tilts. Dichroic projections obtained from difference images are used for the tomographic reconstruction to obtain the 3D magnetization distribution at the nanoscale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Toward 2D and 3D imaging of magnetic nanoparticles using EPR measurements

Purpose: Magnetic nanoparticles (MNPs) are an important asset in many biomedical applications. An effective working of these applications requires an accurate knowledge of the spatial MNP distribution. A promising, noninvasive, and sensitive technique to visualize MNP distributions in vivo is electron paramagnetic resonance (EPR). Currently only 1D MNP distributions can be reconstructed. In this paper, the authors propose extending 1D EPR toward 2D and 3D using computer simulations to allow accurate imaging of MNP distributions. Methods: To find the MNP distribution belonging to EPR measurements, an inverse problem needs to be solved. The solution of this inverse problem highly depends on the stability of the inverse problem. The authors adapt 1D EPR imaging to realize the imaging of multidimensional MNP distributions. Furthermore, the authors introduce partial volume excitation in which only parts of the volume are imaged to increase stability of the inverse solution and to speed up the measurements. The authors simulate EPR measurements of different 2D and 3D MNP distributions and solve the inverse problem. The stability is evaluated by calculating the condition measure and by comparing the actual MNP distribution to the reconstructed MNP distribution. Based on these simulations, the authors define requirements for the EPR system to cope with the added dimensions. Moreover, the authors investigate how EPR measurements should be conducted to improve the stability of the associated inverse problem and to increase reconstruction quality. Results: The approach used in 1D EPR can only be employed for the reconstruction of small volumes in 2D and 3D EPRs due to numerical instability of the inverse solution. The authors performed EPR measurements of increasing cylindrical volumes and evaluated the condition measure. This showed that a reduction of the inherent symmetry in the EPR methodology is necessary. By reducing the symmetry of the EPR setup, quantitative images of larger volumes can be obtained. The authors found that, by selectively exciting parts of the volume, the authors could increase the reconstruction quality even further while reducing the amount of measurements. Additionally, the inverse solution of this activation method degrades slower for increasing volumes. Finally, the methodology was applied to noisy EPR measurements: using the reduced EPR setup’s symmetry and the partial activation method, an increase in reconstruction quality of ≈80% can be seen with a speedup of the measurements with 10%. Conclusions: Applying the aforementioned requirements to the EPR setup and stabilizing the EPR measurements showed a tremendous increase in noise robustness, thereby making EPR a valuable method for quantitative imaging of multidimensional MNP distributions.

60 APPLIED LIFE SCIENCES↗

Deep learning enables nanoscale X-ray 3D imaging with limited data

Deep neural network can greatly improve tomography reconstruction with limited data. A recent effort of combining ptycho-tomography model with the 3D U-net demonstrated a significant reduction in both the number of projections and computation time, and showed its potential for integrated circuit imaging that requires high-resolution and fast measurement speed.

47 OTHER INSTRUMENTATION↗

Radiopaque Resists for Two-Photon Lithography To Enable Submicron 3D Imaging of Polymer Parts via X-ray Computed Tomography

Two-photon lithography (TPL) is a high-resolution additive manufacturing (AM) technique capable of producing arbitrarily complex three-dimensional (3D) microstructures with features 2–3 orders of magnitude finer than human hair. This process finds numerous applications as a direct route toward the fabrication of novel optical and mechanical metamaterials, miniaturized optics, microfluidics, biological scaffolds, and various other intricate 3D parts. As TPL matures, metrology and inspection become a crucial step in the manufacturing process to ensure that the geometric form of the end product meets design specifications. X-ray-based computed tomography (CT) is a nondestructive technique that can provide this inspection capability for the evaluation of complex internal 3D structure. However, polymeric photoresists commonly used for TPL, as well as other forms of stereolithography, poorly attenuate X-rays due to the low atomic number (Z) of their constituent elements and therefore appear relatively transparent during imaging. We present the development of optically clear yet radiopaque photoresists for enhanced contrast under X-ray CT. We have synthesized iodinated acrylate monomers to formulate high-Z photoresist materials that are capable of forming 3D microstructures with sub-150 nm features. In addition, we have developed a formulation protocol to match the refractive index of the photoresists to the immersion medium of the objective lens so as to enable dip-in laser lithography, a direct laser writing technique for producing millimeter-tall structures. Our radiopaque photopolymer then resists increase X-ray attenuation by a factor of more than 10 times without sacrificing the sub-150 nm feature resolution or the millimeter-scale part height. Thus, our resists can successfully replace existing photopolymers to generate AM parts that are suitable for inspection via X-ray CT. By providing the “feedstock” for radiopaque AM parts, our resist formulation is expected to play a critical role in enabling fabrication of functional polymer parts to tight design tolerances.

36 MATERIALS SCIENCE↗

Comparison of 2D and 3D Imaging and Treatment Planning for Postoperative Vaginal Apex High-Dose Rate Brachytherapy for Endometrial Cancer

Purpose: To evaluate bladder and rectal doses using two-dimensional (2D) and 3D treatment planning for vaginal cuff high-dose rate (HDR) in endometrial cancer. Methods and Materials: Ninety-one consecutive patients treated between 2000 and 2007 were evaluated. Seventy-one and 20 patients underwent 2D and 3D planning, respectively. Each patient received six fractions prescribed at 0.5 cm to the superior 3 cm of the vagina. International Commission on Radiation Units and Measurements (ICRU) doses were calculated for 2D patients. Maximum and 2-cc doses were calculated for 3D patients. Organ doses were normalized to prescription dose. Results: Bladder maximum doses were 178% of ICRU doses (p < 0.0001). Two-cubic centimeter doses were no different than ICRU doses (p = 0.22). Two-cubic centimeter doses were 59% of maximum doses (p < 0.0001). Rectal maximum doses were 137% of ICRU doses (p < 0.0001). Two-cubic centimeter doses were 87% of ICRU doses (p < 0.0001). Two-cubic centimeter doses were 64% of maximum doses (p < 0.0001). Using the first 1, 2, 3, 4 or 5 fractions, we predicted the final bladder dose to within 10% for 44%, 59%, 83%, 82%, and 89% of patients by using the ICRU dose, and for 45%, 55%, 80%, 85%, and 85% of patients by using the maximum dose, and for 37%, 68%, 79%, 79%, and 84% of patients by using the 2-cc dose. Using the first 1, 2, 3, 4 or 5 fractions, we predicted the final rectal dose to within 10% for 100%, 100%, 100%, 100%, and 100% of patients by using the ICRU dose, and for 60%, 65%, 70%, 75%, and 75% of patients by using the maximum dose, and for 68%, 95%, 84%, 84%, and 84% of patients by using the 2-cc dose. Conclusions: Doses to organs at risk vary depending on the calculation method. In some cases, final dose accuracy appears to plateau after the third fraction, indicating that simulation and planning may not be necessary in all fractions. A clinically relevant level of accuracy should be determined and further research conducted to address this issue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-209-02: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Clinical Patient Images

Purpose: We develop a method to generate time varying volumetric images (3D fluoroscopic images) using patient-specific motion models derived from four-dimensional cone-beam CT (4DCBCT). Methods: Motion models are derived by selecting one 4DCBCT phase as a reference image, and registering the remaining images to it. Principal component analysis (PCA) is performed on the resultant displacement vector fields (DVFs) to create a reduced set of PCA eigenvectors that capture the majority of respiratory motion. 3D fluoroscopic images are generated by optimizing the weights of the PCA eigenvectors iteratively through comparison of measured cone-beam projections and simulated projections generated from the motion model. This method was applied to images from five lung-cancer patients. The spatial accuracy of this method is evaluated by comparing landmark positions in the 3D fluoroscopic images to manually defined ground truth positions in the patient cone-beam projections. Results: 4DCBCT motion models were shown to accurately generate 3D fluoroscopic images when the patient cone-beam projections contained clearly visible structures moving with respiration (e.g., the diaphragm). When no moving anatomical structure was clearly visible in the projections, the 3D fluoroscopic images generated did not capture breathing deformations, and reverted to the reference image. For the subset of 3D fluoroscopic images generated from projections with visibly moving anatomy, the average tumor localization error and the 95th percentile were 1.6 mm and 3.1 mm respectively. Conclusion: This study showed that 4DCBCT-based 3D fluoroscopic images can accurately capture respiratory deformations in a patient dataset, so long as the cone-beam projections used contain visible structures that move with respiration. For clinical implementation of 3D fluoroscopic imaging for treatment verification, an imaging field of view (FOV) that contains visible structures moving with respiration should be selected. If no other appropriate structures are visible, the images should include the diaphragm. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗