Safe management of actinides in the nuclear fuel cycle: Role of mineralogy

During the past 60 years, more than 1800 metric tonnes of Pu, and substantial quantities of the “minor” actinides, such as Np, Am and Cm, have been generated in nuclear reactors. Some of these transuranium elements can be a source of energy in fission reactions (e.g., 239Pu), a source of fissile material for nuclear weapons (e.g., 239Pu and 237Np), and of environmental concern because of their long-half lives and radiotoxicity (e.g., 239Pu and 237Np). There are two basic strategies for the disposition of these heavy elements: (1) to “burn” or transmute the actinides using nuclear reactors or accelerators; (2) to “sequester” the actinides in chemically durable, radiation-resistant materials that are suitable for geologic disposal. There has been substantial interest in the use of actinide-bearing minerals, especially isometric pyrochlore, A2B2O7 (A = rare earths; B = Ti, Zr, Sn, Hf), for the immobilization of actinides, particularly plutonium, both as inert matrix fuels and nuclear waste forms. Systematic studies of rare-earth pyrochlores have led to the discovery that certain compositions (B = Zr, Hf) are stable to very high doses of alpha-decay event damage. Recent developments in our understanding of the properties of heavy element solids have opened up new possibilities for the design of advanced nuclear fuels and waste forms.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Twenty-four Years of Follow-Up for a Hanford Plutonium Wound Case

A 1985 plutonium puncture wound resulted in the initial deposition of 48 kBq of transuranic alpha activity, primarily 239Pu and 241Am, in a worker’s right index finger. Surgical excisions in the week following reduced the long-term residual wound activity to 5.4 kBq, and 164 DTPA chelation therapy administrations over a 17-month period resulted in urinary excretion of about 7 kBq. The case was published in 1988, but now 20 additional years of follow-up data are available. Annual bioassay measurements have included wound counts, skeleton counts, liver counts, lung counts, axillary lymph node counts, and urinalyses for plutonium and 241Am. These measurements have shown relatively stable levels of 241Am at the wound site, with gradually increasing amounts of 241Am detected in the skeleton. Liver counts has shown erratic detection of 241Am, and lung counts indicate 241Am as shine from the axillary lymph nodes and skeleton. Urine excretion of 239Pu since termination of chelation therapy has typically ranged from 10 to 20 mBq d-1, with 241Am excretion being about 10% of that for 239Pu. In addition, the worker has undergone annual routine medical exams, which have not identified any adverse health effects associated with the intake.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Maximum Likelihood Source Localization Using Elpasolite as a Dual Gamma Neutron Directional Detector

The problem of accurately detecting extremely low levels of nuclear radiation is rapidly increasing in importance in nuclear counter-proliferation, verification, and environmental and waste management. Because the 239Pu gamma signature may be weak, for instance, even when compared to the natural terrestrial background, coincidence counting with the 239Pu neutron signature may improve overall 239Pu detection sensitivity. However, systems with sufficient multiple-particle detectors require demonstration that the increased sensitivity be sufficiently high to overcome added cost and weight. We report the results of measurements and calculations to determine sensitivity that can be gained in detecting low levels of nuclear radiation from use of a relatively new detector technology based on elpasolite crystals. We have performed investigations exploring cerium (Ce3+)-doped elpasolites Cs2LiYCl6:Ce3+0.5% (CLYC) and Cs2LiLa(Br6)90%(Cl6)10%:Ce3+0.5% (CLLBC:Ce). These materials can provide energy resolution (r(E) = 2.35σ(E)/E) as good as 2.9% at 662 keV (FWHM). The crystals show an excellent neutron and gamma radiation response. The goals of the investigation were to set up the neutron/gamma pulse shape discrimination electronics for elpasolite detectors; perform limited static source benchmarking, testing, and evaluation to validate system performance; and explore application of a maximum likelihood algorithm for source location. Data were measured and processed through a maximum likelihood estimation algorithm, providing a direction to the radioactive source for each individual position. The estimated directions were good representations for the actual directions to the radioactive source. This paper summarizes the maximum likelihood results for our elpasolite system.

maximum likelihood, radiation detectors, neutron d↗

Cumulative fission yields of short-lived isotopes under natural-abundance-boron-carbide-moderated neutron spectrum

The availability of gamma spectroscopy data on samples containing mixed fission products at short times after irradiation is limited. Due to this limitation, data interpretation methods for gamma spectra of mixed fission product samples, where the individual fission products have not been chemically isolated from interferences, are not well-developed. The limitation is particularly pronounced for fast pooled neutron spectra because of the lack of available fast reactors in the United States. Samples containing the actinide isotopes 233, 235, 238U, 237Np, and 239Pu individually were subjected to a 2$ pulse in the Washington State University 1 MW TRIGA reactor. To achieve a fission-energy neutron spectrum, the spectrum was tailored using a natural abundance boron carbide capsule to absorb neutrons in the thermal and epithermal region of the spectrum. Our tailored neutron spectrum is unique to the WSU reactor facility, consisting of a soft fission spectrum that contains some measurable flux in the resonance region. This results in a neutron spectrum at greater than 0.1 keV with an average energy of 70 keV, similar to fast reactor spectra and approaching that of 235U fission. Unique fission product gamma spectra were collected from 4 minutes to 1 week after fission using single-crystal high purity germanium detectors. Cumulative fission product yields measured in the current work generally agree with published fast pooled fission product yield values from ENDF/B-VII, though a bias was noted for 239Pu. The present work contributes to the compilation of energy-resolved fission product yield nuclear data for nuclear forensic purposes.

Finn, Erin C.↗

Ageing of a phosphate ceramic used to immobilize chloride contaminated actinide waste

AWE has developed a process for the immobilization of ILW waste containing a significant quantity of chloride using Ca3(PO4)2 as the host material. Waste ions are incorporated into two phosphate based phases, chlorapatite, Ca5(PO4)3Cl, and spodiosite, Ca2(PO4)Cl. Non-active trials performed at AWE using samarium as the actinide surrogate demonstrated the durability of these phases in aqueous solution. Trials of the process using actinide-doped material were performed at PNNL which confirmed the immobilized wasteform resistant to aqueous leaching. Initial leach trials conducted on 239Pu /241Am loaded ceramic at 40°C/28 days gave normalized mass losses of 1.2 x 10-5 g.m-2 and 2.7 x 10-3 g.m-2 for Pu and Cl respectively. In order to assess the response of the phases to radiation-induced damage, accelerated ageing trials were performed on samples in which the 239Pu was replaced by 238Pu. No changes to the crystalline structure of the waste were detected using XRD after the samples had experienced a radiation dose of 4 x 1018 α.g-1. Leach trials showed that there had been an increase in the P and Ca release rates but no change in the Pu release rate.

actinide waste disposal, immobilization, ceramic i↗

ORNL Resolved Resonance Covariance Generation for ENDF/B-VII.1

Resonance-parameter covariance matrix (RPCM) evaluations in the resolved resonance regionwere done at the Oak Ridge National Laboratory (ORNL) for the chromium isotopes, titanium isotopes, {sup 19}F, {sup 58}Ni, {sup 60}Ni, {sup 35}Cl, {sup 37}Cl, {sup 39}K, {sup 41}K, {sup 55}Mn, {sup 233}U, {sup 235}U, {sup 238}U, and {sup 239}Pu using the computer code SAMMY. The retroactive approach of the code SAMMY was used to generate the RPCMs for {sup 233}U. For {sup 235}U, the approach used for covariance generation was similar to the retroactive approach with the distinction that real experimental data were used as opposed to data generated from the resonance parameters. RPCMs for {sup 238}U and {sup 239}Pu were generated together with the resonance parameter evaluations. The RPCMs were then converted in the ENDF format using the FILE32 representation. Alternatively, for computer storage reasons, the FILE32 was converted in the FILE33 cross section covariance matrix (CSCM). Both representations were processed using the computer code PUFF-IV. This paper describes the procedures used to generate the RPCM and CSCM in the resonance region for ENDF/B-VII.1. The impact of data uncertainty in nuclear reactor benchmark calculations is also presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Data Analysis Framework for the NIFFTE Fission Time Projection Chamber

The goal of the Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) is to measure the neu- tron induced fission cross sections for 235,238U and 239Pu to an unprecedented accuracy of 0.5% or better. Cur- rently, the best known fission cross sections are for 235U and have uncertainties of 1 - 3%. For 239Pu, at some energies the uncertainty is as large as 20% [1]. These uncertainties in the cross section can propagate into fis- sion reactor performance parameter calculations such as: criticality, peak power, temperature reactivity, transmu- tation potential, radiotoxicity and decay heat in a respos- itory.

Stave, Sean C.↗

RAPID DETERMINATION OF ACTINIDES IN URINE BY INDUCTIVELY-COUPLED PLASMA MASS SPECTROMETRY AND ALPHA SPECTROMETRY: A HYBRID APPROACH

A new rapid separation method that allows separation and preconcentration of actinides in urine samples was developed for the measurement of longer lived actinides by inductively coupled plasma mass spectrometry (ICP-MS) and short-lived actinides by alpha spectrometry; a hybrid approach. This method uses stacked extraction chromatography cartridges and vacuum box technology to facilitate rapid separations. Preconcentration, if required, is performed using a streamlined calcium phosphate precipitation. Similar technology has been applied to separate actinides prior to measurement by alpha spectrometry, but this new method has been developed with elution reagents now compatible with ICP-MS as well. Purified solutions are split between ICP-MS and alpha spectrometry so that long- and short-lived actinide isotopes can be measured successfully. The method allows for simultaneous extraction of 24 samples (including QC samples) in less than 3 h. Simultaneous sample preparation can offer significant time savings over sequential sample preparation. For example, sequential sample preparation of 24 samples taking just 15 min each requires 6 h to complete. The simplicity and speed of this new method makes it attractive for radiological emergency response. If preconcentration is applied, the method is applicable to larger sample aliquots for occupational exposures as well. The chemical recoveries are typically greater than 90%, in contrast to other reported methods using flow injection separation techniques for urine samples where plutonium yields were 70-80%. This method allows measurement of both long-lived and short-lived actinide isotopes. 239Pu, 242Pu, 237Np, 243Am, 234U, 235U and 238U were measured by ICP-MS, while 236Pu, 238Pu, 239Pu, 241Am, 243Am and 244Cm were measured by alpha spectrometry. The method can also be adapted so that the separation of uranium isotopes for assay is not required, if uranium assay by direct dilution of the urine sample is preferred instead. Multiple vacuum box locations may be set-up to supply several ICP-MS units with purified sample fractions such that a high sample throughput may be achieved, while still allowing for rapid measurement of short-lived actinides by alpha spectrometry.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nuclear Magnetic Resonance Measurements and Electronic Structure of Pu(IV) in [(Me)4N]2PuCl6

The synthesis, electronic structure, and characterization via single crystal X-ray diffraction, nuclear magnetic resonance (NMR) spectroscopy, and magnetic susceptibility of (Me4N)2PuCl6 are reported. NMR measurements were performed to both search for the direct 239Pu resonance and to obtain local magnetic and electronic information at the Cl site through 35Cl and 37Cl spectra. No signature of 239Pu NMR was observed. The temperature dependence of the Cl spectra was simulated by diagonalizing the Zeeman and quadrupolar Hamiltonians for 35Cl, 37Cl and 14N isotopes. Electronic structure calculations predict a magnetic ?5 triplet ground state of Pu(IV) in the crystalline electric field of the undistorted PuCl6 octahedron. A tetragonal distortion would result in a very small splitting (20 cm-1) of the triplet ground state into a nonmagnetic singlet and a doublet state. The Cl shifts have an inflection point at T = 15 K, differing from the bulk susceptibility, indicating a nonmagnetic crystal field ground state. The Cl spin-lattice relaxation time is constant down to T = 15 K, below which it rapidly increases, also supporting the nonmagnetic crystal field ground state.

Mounce, Andrew M.↗

The CIELO collaboration: Progress in international evaluations of neutron reactions on Oxygen, Iron, Uranium and Plutonium

The CIELO collaboration has studied neutron cross sections on nuclides that significantly impact criticality in nuclear technologies - 16O, 56Fe, 235;8U and 239Pu - with the aim of improving the accuracy of the data and resolving previous discrepancies in our understanding. This multi-laboratory pilot project, coordinated via the OECD/NEA Working Party on Evaluation Cooperation (WPEC) Subgroup 40 with support also from the IAEA, has motivated experimental and theoretical work and led to suites of new evaluated libraries that accurately reflect measured data and also perform well in integral simulations of criticality.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Disaggregating measurement uncertainty from population variability and Bayesian treatment of uncensored results

In making low-level radioactivity measurements of populations, it is commonly observed that a substantial portion of net results are negative. Furthermore, the observed variance of the measurement results arises from a combination of measurement uncertainty and population variability. This paper presents a method for disaggregating measurement uncertainty from population variability to produce a probability density function (PDF) of possibly true results. To do this, simple, justifiable, and reasonable assumptions are made about the relationship of the measurements to the measurands (the 'true values'). The measurements are assumed to be unbiased, that is, that their average value is the average of the measurands. Using traditional estimates of each measurement's uncertainty to disaggregate population variability from measurement uncertainty, a PDF of measurands for the population is produced. Then, using Bayes's theorem, the same assumptions, and all the data from the population of individuals, a prior PDF is computed for each individual's measurand. These PDFs are non-negative, and their average is equal to the average of the measurement results for the population. The uncertainty in these Bayesian posterior PDFs is all Berkson with no remaining classical component. The methods are applied to baseline bioassay data from the Hanford site. The data include 90Sr urinalysis measurements on 128 people, 137Cs in vivo measurements on 5,337 people, and 239Pu urinalysis measurements on 3,270 people. The method produces excellent results for the 90Sr and 137Cs measurements, since there are nonzero concentrations of these global fallout radionuclides in people who have not been occupationally exposed. The method does not work for the 239Pu measurements in non-occupationally exposed people because the population average is essentially zero.

61 RADIATION PROTECTION AND DOSIMETRY↗

Non-destructive Assay Measurements Using the RPI Lead Slowing Down Spectrometer

The use of a Lead Slowing-Down Spectrometer (LSDS) is consid- ered as a possible option for non-destructive assay of fissile material of used nuclear fuel. The primary objective is to quantify the 239Pu and 235U fissile content via a direct measurement, distinguishing them through their characteristic fission spectra in the LSDS. In this pa- per, we present several assay measurements performed at the Rensse- laer Polytechnic Institute (RPI) to demonstrate the feasibility of such a method and to provide benchmark experiments for Monte Carlo cal- culations of the assay system. A fresh UOX fuel rod from the RPI Criticality Research Facility, a 239PuBe source and several highly en- riched 235U discs were assayed in the LSDS. The characteristic fission spectra were measured with 238U and 232Th threshold fission cham- bers, which are only sensitive to fission neutron with energy above the threshold. Despite the constant neutron and gamma background from the PuBe source and the intense interrogation neutron flux, the LSDS system was able to measure the characteristic 235U and 239Pu responses. All measurements were compared to Monte Carlo simula- tions. It was shown that the available simulation tools and models are well suited to simulate the assay, and that it is possible to calculate the absolute count rate in all investigated cases.

Lead Slowing Down Spectrometer↗

Lead Slowing Down Spectrometry Analysis of Data from Measurements on Nuclear Fuel

Improved non-destructive assay of isotopic masses in used nuclear fuel would be valuable for nuclear safeguards operations associated with the transport, storage and reprocessing of used nuclear fuel. Our collaboration is examining the feasibility of using lead slowing down spectrometry techniques to assay the isotopic fissile masses in used nuclear fuel assemblies. We present the application of our analysis algorithms on measurements conducted with a lead spectrometer. The measurements involved a single fresh fuel pin and discrete 239Pu and 235U samples. We are able to describe the isotopic fissile masses with root mean square errors over seven different configurations to 6.35% for 239Pu and 2.7% for 235U over seven different configurations. Funding Source(s):

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calcium Phosphate: A potential host for halide contaminated plutonium wastes.

The presence of significant quantities of fluoride and chloride in four types of legacy wastes from plutonium pyrochemical reprocessing required the development of a new wasteform which could adequately immobilize the halides in addition to the Pu and Am. Using a simulant chloride-based waste (Type I waste) and Sm as the surrogate for the Pu3+ and Am3+ present in the waste, AWE developed a process which utilised Ca3(PO4)2 as the host material. The waste was successfully incorporated into two crystalline phases, chlorapatite, [Ca5(PO4)3Cl], and spodiosite, [Ca2(PO4)Cl]. Radioactive studies performed at PNNL with 239Pu and 241Am confirmed the process. A slightly modified version of the process in which CaHPO4 was used as the host was successful in immobilizing a more complex multi-cation oxide–based waste (Type II) which contained significant concentrations of Cl and F in addition to 239Pu and 241Am. This waste resulted in the formation of cation-doped whitlockite, Ca3-xMgx(PO4)2, β-calcium phosphate, β-Ca2P2O7 and chlor-fluorapatite rather than the chlorapatite and spodiosite formed with Type I waste.

transuranic waste, apatite, calcium phosphate↗

Results of The Excreta Bioassay Quality Control Program For April 1, 2008 through March 31, 2009

A total of 62 urine samples and 6 spiked fecal samples were submitted during the report period (April 1, 2008 through March 31, 2009) to General Engineering Laboratories, South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for Sr, 238Pu, 239Pu, 241Am, 243Am 235U, 238U, elemental uranium and fecal analyses for 241Am, 238Pu and 239Pu were tested this year. The number of QC urine samples submitted during the report period represented 1.3% of the total samples submitted. In addition to the samples provided by IDP, GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 34% of the analyses processed by GEL during the third year of this contract were quality control samples. GEL tested the performance of 21 radioisotopes, all of which met or exceeded the specifications in the Statement of Work within statistical uncertainty. IDP concluded that GEL was performing well for all analyses tested, and concerns identified earlier were satisfactorily resolved (see section on Follow-up on Concerns During the Fourth Contract Year).

61 RADIATION PROTECTION AND DOSIMETRY↗

Lead Slowing-Down Spectrometry Time Spectral Analysis for Spent Fuel Assay: FY11 Status Report

Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) from next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R&D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT supports a multi-institutional collaboration, of which PNNL is a part, to study the feasibility of Lead Slowing Down Spectroscopy (LSDS). This technique is an active nondestructive assay method that has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than the approximately 10% typical of today's confirmatory assay methods. This document is a progress report for FY2011 PNNL analysis and algorithm development. Progress made by PNNL in FY2011 continues to indicate the promise of LSDS analysis and algorithms applied to used fuel. PNNL developed an empirical model based on calibration of the LSDS to responses generated from well-characterized used fuel. The empirical model, which accounts for self-shielding effects using empirical basis vectors calculated from the singular value decomposition (SVD) of a matrix containing the true self-shielding functions of the used fuel assembly models. The potential for the direct and independent assay of the sum of the masses of 239Pu and 241Pu to within approximately 3% over a wide used fuel parameter space was demonstrated. Also, in FY2011, PNNL continued to develop an analytical model. Such efforts included the addition of six more non-fissile absorbers in the analytical shielding function and the non-uniformity of the neutron flux across the LSDS assay chamber. A hybrid analytical-empirical approach was developed to determine the mass of total Pu (sum of the masses of 239Pu, 240Pu, and 241Pu), which is an important quantity in safeguards. Results using this hybrid method were of approximately the same accuracy as the pure empirical approach. In addition, total Pu with much better accuracy with the hybrid approach than the pure analytical approach. In FY2012, PNNL will continue efforts to optimize its empirical model and minimize its reliance on calibration data. In addition, PNNL will continue to develop an analytical model, considering effects such as neutron-scattering in the fuel and cladding, as well as neutrons streaming through gaps between fuel pins in the fuel assembly.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear Technology Research and Development (NTRD) Technical Monthly February FY18

[LANL] Energy-resolved neutron imaging data on transmutation fuels (Figure 1A) containing Am and Np were reanalyzed. The analysis using the SAMMY code was focused on retrieving absolute densities for five isotopes, 238U, 239Pu, 240Pu, 241Am and 237Np. The bulk composition described by partial densities of the main isotopes 237Np, 239Pu, 240Pu, and 242Am, resultant from the initial analysis agreed to better than 0.1 g/cc with the partial densities determined by mass spectrometry, except for 238U, which was overestimated by the initial approach. It was found that due to only a single resonance of 238U present in the fitted energy range of 1eV to 9eV (Figure 1 B), the refined areal densities for 238U were statistically insignificant, resulting in large errors. Consequently, the fitted energy range was extended to 24eV to include a second 238U resonance (Figure 1C, D), which stabilized the 238U areal densities, providing excellent agreement for all five isotopes. (A. Losko and S. Vogel)