Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wetting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

A Technical-Economic Assessment of Brackish Water Treatment for Fossil Power Plant Cooling with Reduced Environmental Impact

The power sector accounts for approximately 40% of freshwater use in the U.S. Reusing non-traditional water resources is critical for alleviating water stress in the western United States. The purpose of this study is to conduct a techno-economic system analysis to evaluate the potential of brackish water treatment for wet cooling towers at existing thermo-electric generating units (EGUs). It aims to address current knowledge gaps in support of non-traditional water resources planning and the electric power industry's water decision- and policy making. An engineering-economic model was developed and combined with DuPont's water application value engine (WAVE) v1.82 to evaluate the viability of retrofitting reverse osmosis-based brackish water treatment systems to individual existing EGUs and then aggregating the unit-level results to the fleet level. In the base case, brackish water treatment can reduce freshwater consumption of electric generation units by 94–100% while increasing the cost of electric generation by approximately 10% and have marginal impacts on the units' parasitic loads. When zero liquid discharge systems are applied to brackish water brine treatment, the cost of electric generation and freshwater consumption savings and energy penalty to the power plant significantly increase. These costs are even higher than dry cooling deployment in lieu of wet cooling towers. The choice of freshwater savings between brackish water desalination and dry cooling deployment depends greatly on how the concentrated brines are managed. Multiple factors must be considered when supporting decision-making in water management and planning in power sectors, which include non-traditional water quantity and quality as well as trade-offs among technical performance, economics, and environmental impacts.

Wu, Zitao↗

The Nuclear Fuel Cycle: Safe Management of Spent Nuclear Fuel

The aim for storage of spent nuclear fuel (SNF) either in wet or in dry storage systems is to ensure general safety objective s are met throughout a desired storage period. Staff at the Savannah River National Laboratory (SRNL), in collaborations with partners at other national laboratories, industry research organizations, and the University of South Carolina (UofSC), have performed materials aging testing and analyses, and have established nuclear materials aging management programs to support extended periods of safe storage of research reactor (RR) SNF and of commercial power reactor (PR) SNF pending ultimate disposal. Several example challenges include susceptibility of aluminum SNF from research reactors to corrosion in poor quality water (wet storage). In dry storage, aluminum SNF can release hydrogen via radiolysis of the hydrated oxides on the aluminum cladding. Austenitic stainless steel canisters used for dry storage are susceptible to chloride-induced stress corrosion cracking (outside-in attack) that threaten the confinement boundary provided by the canister. This paper further describes these challenges, among others, and the formulated solutions to support extended safe storage of SNF.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preparation of SiO 2 —TiO 2 composite aerogels and SiO 2 @TiO 2 core-shell aerogels with high thermal stability and enhanced photocatalysis

According to one inventive concept, a method for forming an aerogel includes forming a SiO 2 gel, forming a mixture of the SiO 2 gel and a TiCl 4 -derived precursor sol, wherein the TiCl 4 sol is comprised of TiCl 4 and a solvent, forming a SiO 2 /TiO 2 wet gel, drying the SiO 2 /TiO 2 wet gel, and heating the dried SiO 2 /TiO 2 gel.

Neto, Elias Paiva Ferreira↗

High Temperature Ternary Chloride Molten Salt Pump

This work investigates the design criteria considering thermal, structural, and material selection of a ternary chloride (MgCl2-NaCl-KCl) molten salt pump that is capable of running at temperatures above 720 °C. In this work, preliminary testing of salt-wetted hydrodynamic bearings was done to investigate different material pairings including Colmonoy grades, Stellite grades, and a novel Nickel Tungsten Carbide alloy (HybrimetTM NiWC3b) used as a High Velocity Oxygen Fuel (HVOF) coating. The coating has shown to withstand the corrosive nature of the molten salt. The pump wetted components are made of Inconel 625 and features a carbon ring seal (CIRPAC Seal) flooded with a N2 gas flow on the overhead to keep salt vapors from interacting with the external ambient air. A comprehensive pump test program has been completed. Over 90 hours run time pumping hot chloride salts at temperatures up to 720 °C in which enough data was captured to produce performance curves at 3 different operating speeds. This research showcases a promising design for use in the Concentrated Solar Power (CSP) Gen 3 liquid-pathway and sets the ground for further development and use of the HybrimetTM NiWC3b as a competitive alternative to available superalloys.

14 SOLAR ENERGY↗

High Temperature Ternary Chloride Molten Salt Pump

This work investigates the design criteria considering thermal, structural, and mate-rial selection of a ternary chloride (MgCl2-NaCl-KCl) molten salt pump that is capable of running at temperatures above 720 °C. In this work, preliminary testing of salt-wetted hydrodynamic bearings was done to investigate different material pairings including colmonoy grades, stellite grades, and a novel NiWC-based alloy (i.e. HybrimetTM NiWC3b) used as a High Velocity Ox-ygen Fuel (HVOF) coating. The coating has shown to withstand the corrosive nature of the salt, and is additionally used to protect a 316L stainless steel pump reservoir. The pump wetted components are made of Inconel 625, and it features a carbon ring seal developed by Flows-erve flooded with a N2 gas flow on the overhead to keep salt vapors from interacting with the external ambient air. This research showcases a promising design for use in the CSP Gen 3 liquid-pathway and sets the ground for further development and use of the HybrimetTM NiWC3b as a competitive alternative to available superalloys. Further work will further characterize the pump by performance & cycle testing in molten salt at higher temperatures.

14 SOLAR ENERGY↗

Pyrolysis of Radioactive Spent Resins in the PRIME Installation - 20190

Montair and Belgoprocess developed the pilot PRIME (Pyrolysis Resins In Mobile Electric) Installation for treatment of spent resins in one single reactor without pre-treatment and without intermixing of other waste, allowing for easy traceability and isotopic characterization of the end product. Both low level waste (LLW, < 2 mSv/h) and medium level waste (MLW, > 2 mSv/h) can be treated in the installation. The PRIME pilot installation is designed to treat 2 batches of 100 liter of saturated ion exchange resins over a period of 24 hours. A dosing unit with screw feeder is used for the dosing of the saturated ion exchange resins to the pyrolysis reactor. This completely new developed innovative pyrolysis reactor contains a special design mechanical stirrer and can operate at a temperature of up to 600 deg. C under inert conditions. As a result, the organic molecules will decompose at an accelerated rate until only the mineralized material remains. The lower temperature and the absence of oxygen also prevent the breakdown of ion exchange resins into (powdery) ash, which is a considerable advantage during further handling. Gases that are released during drying and pyrolysis are treated in an also newly developed thermal oxidizer, which uses an innovative, electrically heated design instead of a traditional natural gas- or fuel oil secondary combustion chamber design. After passing through the thermal oxidizer, the gases are cooled down to saturation temperature and treated in the wet scrubbing system. An extraction fan keeps the system under negative pressure to prevent the possibility of any off-gas leakage out of the system. A series of tests were performed successfully with wet cationic resins, anionic resins and a mixture of both. The results of these tests are described in the presentation. For intellectual property protection, the system and process of pyrolysis of organic waste and the system of thermal oxidation of pyrolysis gases described in this paper are patent pending. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Criticality Analysis of FSV Spent Nuclear Fuel in the DOE Standard Canister

The U.S. Department of Energy (DOE) is responsible for managing over 300 types of spent nuclear fuel (SNF). To manage this large variety of fuel types, DOE plans to employ standardized canisters for the transportation, long-term storage, and eventual disposal of SNF. Idaho National Laboratory is currently supporting DOE’s SNF Packaging Demonstration Project, in which Fort Saint Vrain (FSV) fuel assemblies will be loaded into a DOE Standard Canister. This paper presents criticality calculations demonstrating that all four or five FSV fuel assemblies loaded into the DOE Standard Canister will remain subcritical in any expected normal or credible abnormal conditions. Previous criticality analyses were performed for one FSV fuel assembly and 12 Peach Bottom Core 2 fuel elements loaded into a DOE Standard Canister. This paper covers the criticality analysis performed for loading both four and five FSV fuel assemblies into a DOE Standard Canister. Various intact and degraded mode configurations were modeled in conducting the criticality calculations. This analysis encompassed three different configurations: (1) a single DOE Standard Canister loaded into a concrete storage overpack, (2) seven DOE Standard Canisters loaded into a concrete storage overpack, and (3) nine DOE Standard Canisters loaded into a concrete storage overpack. The overpack dimensions were varied for each of the three configurations, and transport, storage, and disposal scenarios were analyzed for each configuration. For transport scenarios, a pair of degradation cases was analyzed. In the first case, the fuel compacts became degraded and were removed from the fuel block, then deposited at the bottom of a horizontally placed canister, thereby simulating a drop event. The canister was considered to remain intact. In the second case, the spacing between horizontally placed canisters in a nine-canister overpack was reduced such that the canisters were piled on top of each other, simulating a drop event. For this case, no degradation of the canister internals or fuel was considered. For storage scenarios, the water moderator location in the system was varied to enable identification of the most reactive configurations. Dry and wet conditions were analyzed for the fuel materials, canister, and overpack. For disposal scenarios, two degradation cases were analyzed. In the first, the stainless-steel internals of the canister degraded to either hematite or goethite under both dry and wet conditions. In the second case, degraded FSV fuel formed a uranium-water slurry that filled the coolant/void holes. None of the cases presented exceeded the application specific upper subcritical limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling and Analysis of a Heat Pump Clothes Dryer with Thermal Energy Storage

Clothes drying is an energy-intensive process that causes significant electricity consumption and carbon emissions in the US. Approximately 83% of Households in the US own a tumble clothes dryer at home and 80% of dryers are electrical resistance dryers with low energy efficiency. Heat pump technology makes it possible for highly efficient and clean drying. Additionally, the ventless design of heat pump clothes dryers (HPCD) provides more installation flexibility. HPCD involves three primary mediums: wet clothes, a closed air loop, and a refrigerant circuit. The evaporator is used to dehumidify the wet air and the condenser is used to re-heat the dry air. One of the critical technological barriers to HPCD market penetration is its long drying time, primarily due to the relatively low discharging temperature and the slow response during the warm-up period. In this study, the thermal energy storage (TES) technology is adopted to address this challenge by providing pre-heating of air prior to the condenser to increase the operating temperature of the process air. The heat pump will charge the phase change material (PCM) in the TES device with heating energy during clothes washing and the PCM will discharge the stored heat to facilitate air heating during clothes drying. To analyze the optimal design and potential for energy saving and drying time reduction, a mathematical model of the HPCD system was developed. The HPCD is a highly dynamic system with a coupled heat and mass transfer and heat pumping cycle. This paper provides solutions to simulate the transient behavior of the system while maintaining low computational cost. The modeling result indicates reduced energy consumption and drying time by integrating TES with HPCD, as compared to electrical resistance dryers. The study can provide significant insights into improving building flexibility with TES and smart appliances.

Liu, Xiaoli↗

Additive manufacturing of hierarchical three- dimensional micro-architected aerogels

Disclosed here is a method for making a three-dimensional micro-architected aerogel, comprising: (a) curing a reaction mixture comprising a co-sol-gel material (e.g., graphene oxide (GO)) and at least one catalyst to obtain a crosslinked co-sol-gel (e.g., GO hydrogel); (b) providing a photoresin comprising a solvent, a photoinitiator, a crosslinkable polymer precursor, and a dispersion of the crosslinked co-sol-gel (e.g., GO hydrogel); (c) curing the photoresin using projection microstereolithography layer-by-layer to produce a wet gel having a pre-designed three-dimensional structure; (d) drying the wet gel to produce a dry gel; and (e) pyrolyzing the dry gel to produce a three-dimensional micro-architected aerogel (e.g., graphene aerogel). Also disclosed is a photoresin for projection microstereolithography, comprising a solvent, a photoinitiator, a crosslinkable polymer precursor, and a dispersion of a crosslinked co-sol-gel.

Worsley, Marcus A.↗

Modeling the Integration of Marine Energy into Microgrids - Wave Resource Assessment

This submission has wave resource assessments which were conducted for six locations based on IEC requirements using the DOE WPTO Hindcast data and MHKiT. The locations are chosen to provide varying wave climates and include PacWave South, OR; Wave Energy Testing Site (WETS), HI; Molokai, HI; St. Paul, AK; Yakutat, Ak; and Sebastion, FL. It includes the data gathered and the resulting report. This submission also includes a link to Hindcast dataset and some relevant software.

16 TIDAL AND WAVE POWER↗

Catalytic Dehydrogenation of Ethane over Mn Oxide Supported on Zeolite Chabazite

A new class of Mn-containing zeolites prepared by incipient wetness impregnation (IWI) have been found to catalyze the ethane dehydrogenation reaction with high selectivity (98 %+). Preparation by IWI leads to the formation of Mn 2 O 3 nanoparticles on the external surface of the zeolite crystals and herein is shown that the primary active sites for the reaction are located on the surface of these particles. Propane dehydrogenation is also successfully catalyzed by this catalyst. Furthermore, other Mn-zeolites (MFI and BEA) also have high reactivity and selectivity towards light alkane dehydrogenation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Highly efficient Pt catalyst on newly designed CeO 2 -ZrO 2 -Al 2 O 3 support for catalytic removal of pollutants from vehicle exhaust

Pt-CeO 2 catalysts have been widely studied for the vehicle emission control. Designing novel CeO 2 based supports with improved physical-chemical properties has become a research hotspot to further promote the catalytic performance and stability of Pt-CeO 2 catalysts. In this work, through utilizing a unique, two-step incipient wetness impregnation (T-IWI) method for ceria-zirconia-alumina (CZA-T) support preparation, a Pt single site catalyst (Pt/CZA-T) with excellent thermal stability was synthesized. Higher oxidation activity and Oxygen storage capacity (OSC) were achieved on activated Pt/CZA-T, comparing to Pt catalysts on regular CeO 2 /Al 2 O 3 (Pt/CA) and one-step prepared CeZrO x /Al 2 O 3 (Pt/CZA). Via the modification of hydrophilic/hydrophobic properties of γ-Al 2 O 3 by this unique T-IWI method, finer Ce 0.9 Zr 0.1 O 2 particles with higher density of surface defects were formed on CZA-T, on which a higher Pt dispersion and stronger Pt-O-Ce interaction were achieved. Upon activation, smaller, well-dispersed Pt clusters on CZA-T were generated. It was concluded that the CO oxidation performance and OSC were highly related to the size of Pt clusters on different supports that we have developed. Finally, more Pt sites located at Pt cluster-CeZrO x interfaces, which were the real active sites, were responsible for the highest OSC function and CO oxidation activity of activated Pt/CZA-T catalyst.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PERFORMANCE ANALYSIS OF AN ENGINEERING SCALE HYDROTHERMAL LIQUEFACTION SYSTEM

This work evaluates the Modular Hydrothermal Liquefaction System (MHTLS), an engineering-scale, integrated continuous HTL plant operated at the Pacific Northwest National Laboratory (PNNL), for converting realistic wet wastes into energy-dense biocrudes. The production campaigns discussed here processed algae, sewage sludges, lignocellulosic blends, Industrial food waste, and engineered food-waste slurries at 350?°C and around 200?bar, with nominal feed rates of ~12?L?h?¹. We report biocrude yields and composition, establish mass and elemental (C, N) balances, and quantify energy performance via heater duties, heat-exchanger behavior, and system-level efficiencies. Biocrudes contained 76–80?wt?% C (dry, ash-free) with HHVs of 38-41?MJ?kg?¹, substantially higher than feed materials HHVs of 16.6–26.1?MJ?kg?¹ and approaching petroleum fuels. Dry, ash-free biocrude yields of 32–53?wt?% corresponded to 43–71?wt?% carbon yields, with 18–40?wt?% of feed carbon routed to the aqueous phase. Thermal efficiencies were 50-65%, and total energy efficiencies, including reactor heat input, were 35-55%. A counter-current tube-in-tube heat exchanger delivered U values of 200–450?W?m?²?K?¹, with fouling-induced declines impacting heat recovery and heater duty. The analysis highlights three priorities for the process intensification of HTL: robust, fouling-resistant heat recovery, hydrodynamically suitable reactor and heat-exchanger designs, simplified and predictable solids management, and biocrude-water separation.

Biocrude production↗

Lower and upper threshold limit for artificial neural network based chilled and condenser water temperatures set-point control in a chilled water system

In this study, an ANN (artificial neural network) based real-time optimized control algorithm for a chilled water cooling system was developed and applied in an actual building to analyze its cooling energy saving effects through in-situ application and actual measurements. For this purpose, the cooling tower’s CndWT (condenser water temperature) and the chiller’s ChWT (chilled water temperature) were set as system control variables. To evaluate algorithm performance, the electric consumption and the COP (coefficient of performance) were compared and analyzed when ChWT and CndWTs were controlled conventionally and controlled based on the ANN. During the analysis, unexpected abnormal data was observed due to insufficient training data and limited consideration of OWBT (outdoor air wet-bulb temperature) when determining the CndWT set-point. Therefore, it is necessary to further build training data from a wider range of conditions and to set the lower limit of CndWT set-point to at least +3.6 °C above OWBT when the OWBT is higher than 23 °C, so that further energy savings can be achieved.

42 ENGINEERING↗

Pervasive low-velocity layer atop the 410-km discontinuity beneath the northwest Pacific subduction zone: Implications for rheology and geodynamics

Regional triplication waveforms of five intermediate-depth events are modeled to simultaneously obtain the compressional (P) and shear (SH) wave velocity structure beneath northwestern Pacific subduction zone. Both the P- and SH-wave velocity models for three different sub-regions show a low-velocity layer (LVL) with a thickness of ~55-80 km lying above the 410-km discontinuity with a ~900 km lateral extent from the Japan Sea to the northeastern Asian continental margin. With the dihedral angle approaching to zero around 400 km, a minute amount of melt atop the 410-km discontinuity caused by the hydrous slab might completely wet olivine grain boundaries and result in a low seismic velocity layer in this specific subduction zone. This mechanism suggests that the 410-LVL is a low viscosity zone that would partially decouple the upper mantle from the transition zone. We infer that the widespread 410-LVL provides evidence for a water-bearing mantle transition zone beneath the western Pacific subduction zone.

58 GEOSCIENCES↗

Impact of coolant temperature on the combustion characteristics and emissions of a stratified-charge direct-injection spark-ignition engine fueled with E30

The direct injection spark ignition (DISI) engine has received considerable attention due to its potential to increase the power density of traditional spark ignition engines while significantly improving fuel economy through lean, unthrottled combustion. However, the market introduction of DISI engines operated in a lean combustion mode is inhibited by their unsatisfactory emissions, especially during cold start conditions that make proper mixture formation more challenging. Ethanol-blended gasoline, now a widely used fuel, makes the cold start of a DISI engine more difficult, leading to higher HC and soot emissions because of the high latent heat of vaporization of ethanol relative to gasoline. This work investigated the impact of coolant temperature on the characteristics of combustion and emissions in a stratified-charge DISI engine fueled with an E30 fuel (i.e. 30% ethanol in gasoline), while the coolant temperature was alternated between four levels (45, 60, 75, and 90 °C) to simulate different conditions throughout the warm-up process. The experiments showed that the coolant temperature affected the post-spark inflammation time, as well as the speed, intensity, and stability of the combustion process in the engine. When the coolant temperature rose, the engine produced more NOX and less CO, PM and HC. In addition, high-speed direct photography was used to obtain crank-angle resolved images of fuel sprays and flames in the cylinder. As the coolant temperature rose, the liquid spray lengths became shorter, reducing the possibility of wall wetting, and reduced irradiance from soot particles also indicated less nonpremixed combustion. The in-cylinder imaging results are consistent with the observed combustion and emission characteristics and shed light on the underlying processes. Finally, some potential solutions to the emissions challenges faced here could be either raising in-cylinder temperatures by using trapped residuals or modifying the injection schedule, for example by increasing the number of injections or to inject later in the cycle into a higher-density environment.

42 ENGINEERING↗

Radionuclide surrogate aerosolization, resuspension and suppression in hazardous situations

Radioactive fire following nuclear accidents causes resuspension of radioactive contamination that can spread over large areas. Although many papers focus on particle deposition and resuspension, a limited number of studies model its suppression. Even less data is available for the comparison of emissions across particle size, surface, and mode of resuspension. In this study, cerium dioxide surrogate for internal hazards such as radionuclide particle matter was aerosolized into a large chamber and subsequently resuspended after sedimentation. Resuspension was induced by common modes of human movement including walking, wind, and driving on common surfaces including polyvinyl chloride (PVC), artificial grass (turf), and concrete in a 5.8 m long, 3.7 m wide and 3 m high tent. The resuspension was experimentally measured for two particle sizes (1 and 10 μm) at three different heights (0.3 m, 1.2 m, and 2.4 m) and compared across size, surface, and mode of resuspension. Particle size distribution was measured using an aerodynamic particle sizer and the resuspended particles were collected with the wetted wall cyclone aerosol collector and quantitated using inductively coupled plasma mass spectrometry. The testing was repeated with the F-500 fire retardant application to study its effect on resuspension. In this study, artificial grass flooring was found to generate the most resuspension, with walking on turf for the 1 μm particle testing yielding the highest factor overall. Concrete had the lowest resuspension, showing variations in the size distribution of aerosol as a function of height from the source resuspension factors. The application of fire retardant was found to significantly reduce surrogate resuspension, regardless of resuspension method or testing surface. Here, the results provide impactful information regarding the different modes of resuspension including human transport (walking and driving) and wind for the resuspension of radionuclide surrogate particles deposited onto common surfaces and the effect of fire retardant application on their resuspension, leading to higher levels of safety for nuclear energy plants and facilities.

42 ENGINEERING↗

Superhydrophilicity of $α$-alumina surfaces results from tight binding of interfacial waters to specific aluminols

Understanding the microscopic driving force of water wetting is challenging and important for design of materials. The relations between structure, dynamics and hydrogen bonds of interfacial water can be investigated using molecular dynamics simulations. Here, contact angles at the alumina (0001) and ($11\bar{2}0$) surfaces are studied using both classical molecular dynamics simulations and experiments. To test the superhydrophilicity, the free energy cost of removing waters near the interfaces are calculated using the density fluctuations method. The strength of hydrogen bonds is determined by their lifetime and geometry. Both surfaces are superhydrophilic and the (0001) surface is more hydrophilic. Interactions between surfaces and interfacial waters promote a templating effect whereby the latter are aligned in a pattern that follows the underlying lattice of the surfaces. Translational and rotational dynamics of interfacial water molecules are slower than in bulk water. Hydrogen bonds between water and both surfaces are asymmetric, water-to-aluminol ones are stronger than aluminol-to-water ones. Molecular dynamics simulations eliminate the impacts of surface contamination when measuring contact angles and the results reveal the microscopic origin of the macroscopic superhydrophilicity of alumina surfaces: strong water-to-aluminol hydrogen bonds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗