Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vacuum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

A NASA First in Nano-Technology: Nanoscale Vacuum Tube for Radiation Immune Electronics

Vacuum provides the fastest electron speed, better than any semiconductor. Nevertheless vacuum tubes were bulky, fragile and consumed much power. Now nanotechnology has enabled fabrication of vacuum tubes at nanoscale in silicon chips. The speed, immunity to radiation and high temperature operation are expected to revolutionize space electronics.

Ingrid Desilestre↗

Suited Ground Vacuum Chamber Testing Decompression Sickness Tiger Team Report

Suited vacuum chamber testing is critical to flight crew training, sustaining engineering, and development engineering. Most suited vacuum chamber testing at NASA’s Johnson Space Center (JSC) involves crewmembers or human test subjects working at a hypobaric pressure of 4.3 psia, which requires that an oxygen prebreathe be performed prior to decompression to reduce the risk of decompression sickness (DCS). Since 1986, NASA’s policy has been to require a 4-hour resting prebreathe for hypobaric chamber exposures of 4.2 psia lasting greater than 30 minutes. There have been no reports of Type II (i.e., serious, potentially life-threatening) DCS at NASA while using this prebreathe protocol. Several chamber runs, believed to be approximately 5% of all runs, are believed to have been terminated due to Type I DCS symptoms that were performance impairing; however, detailed records of DCS symptoms during suited vacuum chamber runs are not available. The adequacy of the 4-hour prebreathe protocol, as well as the processes by which prebreathe protocols and policies are established, became the subject of significant discussion in April 2018 when medical planning was initiated for chamber runs that were scheduled to occur later in 2018 that would last 8 hours or more with high metabolic rates.

Abercromby, Andrew F. J.↗

High-Vacuum Triboelectric Charging of Space Materials

In the high-vacuum environment of space and the surface of the moon, static electricity on surfaces lacks the atmospheric dissipation mechanisms found on earth. As a result, the ubiquitous triboelectric charging mechanism can lead to high levels of charge on surfaces. This static charge can result in damage to sensitive devices, interfere with communications, and electrostatic levitation of lunar dust. At the NASA Electrostatics and Surface Physics Laboratory (ESPL), we use different apparatuses and techniques to tribo-charge materials in high-vacuum (10-5 torr), including a tribo-robot and a triboelectric regolith-material stage (TRMS). The tribo-robot is used to rub two materials together, and fieldmeters and electrometers can be used to determine how much charge is on the materials. The TRMS is used to drag different materials onto a bed of lunar simulant. This system is used to characterize how materials may interact with lunar dust using fieldmeters, electrometers, and laser scattering. Using these methods, we are building a database of how different space materials charge when contacting each other at high-vacuum, and how materials triboelectrically interact with the lunar surface.

Joseph Toth↗

Gaseous By-Product of Thermal Vacuum Processing of Lunar Highland Simulant

Scientists at Kennedy Space Center are advancing technologies to achieve oxygen extraction on the Lunar surface. One such technology is Molten Regolith Electrolysis (MRE) in which regolith simulant is melted under high temperatures to perform oxygen extraction through electrolysis of the melt pool. A study was conducted to understand the molten formation and proper-ties of Lunar Highlands Simulants (LHS-1) under high vacuum environments ranging between 10-6 Torr. These studies include investigating the regolith melt behavior and by-product gas analysis systems to prepare for pilot plant development and operations. The off-gassing rates and pressure build-up, gaseous compounds, and material compatibility may be a risk to MRE systems. The KSC findings are reported here for inclusion into future mis-sion architecture and operational planning. The four stages of the experiment were vacuum, resistive heating, regolith melt and gas detection. The regolith mass of 70 g was melted in a 40 cm tall x 50 cm diameter vacuum chamber at temperature increase rate 47 ℃ /min and ramp rate of 1 ampere/3 min up to an 18-amp maximum. The test is conducted for about 60 minutes and the constituent gases produced during heating of regolith is monitored with a re-sidual gas analyzer. During the molten formation, primary off-gassing volatiles included water vapor (18 amu), a peak at 44 amu (FeO2 – expected), and atomic oxygen (16 amu), among a series of other compounds that could create compatibility issues such as magnesium, chlorine, and silicon oxide. These results add to the knowledge required for successful oxygen extraction on the moon.

Molten Regolith Electrolysis↗

Carbothermal Reduction Demonstration: Laser Driven Reaction in a Thermal-Vacuum Environment and Project Status

Introduction: Lunar regolith is approximately 45% oxygen by mass. The majority of the oxygen is bound in silicate minerals. The carbothermal reduction process has been proven to be effective at removing oxygen from lunar regolith simulants [1]. The Carbothermal Reduction Demonstration (CaRD) project aims to increase the Technology Readiness Level (TRL) of a combined solar concentrator and carbothermal reduction systemin order to demonstrate this technology on the lunar surface. The CaRD project is divided into two design cycles, a brass board and prototype. The status of both design cycles will be discussed, as well as concepts for how this technology can be applied to the Artemis program in the future. Brassboard Vacuum Test: For the brassboard demonstration, a 2 kW Nd-YAG laser was used to heat lunar regolith simulant within a carbothermal reactor developed by Sierra Space. The reactor was placed inside of a 15 ft thermal vacuum chamber at the Johnson Space Center. The resulting reaction products were analyzed using both a gas chromotograph and mass spectrometer provided by Kennedy Space Center. Thermal data was also collected. Prototype Design: For the prototype, the CaRD team will perform another thermal vacuum test at JSC using the same interfaces and assets developed for the brassboard but will test a new carbothermal reactor design that Sierra Space is developing through the Carbothermal Oxygen Production Reactor (COPR) Tipping Point project that will include a means to autonomously move regolith in and out of the reactor. In addition, a deployable solar concentrator is being developed by Glenn Research Center using mirrors produced by Carbon Mirror Applications. The solar concentrator will be used to deliver solar energy into a carbothermal reactor to melt regolith and extract oxygen. Avionics and software for the concentrator are being developed by Kennedy Space Center. Future Concepts: An ongoing task within the CaRD project is to update models that can be used to determine the mass, power, and size of In-Situ Resource Utilization concepts at various scales. These models can now be used to analyze alternatives for future applications based on the latest available data.

A J Paz↗

Thermal Vacuum and Vibration Testing of the Differential Thermal Expansion Thermal Switch

The Extended Stroke, Reverse Operation, Differential Expansion Thermal Switch for Extreme Variable Environments uses materials with both positive and negative coefficients of thermal expansion (CTE) arranged in concentric cylinders so that the thermal switch (TS) operates passively, opening a gap between interfaces to create a low thermal contact when cold, and closing the gap between interfaces to create a high thermal contact when hot. This paper details the testing of the TS at Marshall Space Flight Center including the pre-vibe thermal vacuum cycle test, vibration test, post-vibe thermal vacuum cycle test, and long duration thermal vacuum cycle test. The pre- and post-vibe thermal cycle and the long duration cycle test tested to hot and cold plateau initial temperatures of 40 °C, and -173 °C, respectively. The pre- and post-vibe tests required plateau holds of at least 2 hours, whereas the long duration cycle test required plateau holds of at least 20 hours. The tests each used a rate of temperature change of < 2 °C/min when transitioning between plateaus. The data collected from each thermal test is compared to show the operation of the TS both before and after the vibration test to GEVS levels, and throughout the long duration cycle test. From the data collected, the total conductance through the TS interfaces is calculated for both on (TS closed – during hot plateau) and off (TS open – during cold plateau) configurations, and the turndown ratio is also calculated. Challenges and lessons learned from the testing are also discussed.

thermal control technology↗

On Predicting Transient Pressure in Vacuum Systems Featuring Getter Materials

Getter materials have been used to reduce pressure or partial pressures in a variety of vacuum applications ranging from vacuum tubes to space flight science instruments. Testing of getter materials has tended to emphasize the capacity of candidate materials to collect specific gas species in sufficient quantities to size them in these applications. When determining a getter material’s capacity, it is typically subjected to enough excess target gas to ensure it sorbs as quickly as possible. However, when both the gas source strength and the getter’s sorption rate exhibit transient decay behavior, such data is not sufficient to predict the targeted species’ partial pressure within a vacuum system as a function of time.

M. S. Woronowicz↗

Trace Contaminant Control Test Bed for Evaluation of TCC Prototypes with Vacuum Regenerable and Non-Regenerable Sorbents

A new Space Suit Exploration Portable Life Support System (xPLSS) is being designed, built, integrated, and tested into the Extra-Vehicular Mobility Unit (xEMU). The Trace Contaminant Control (TCC) system is a component in the oxygen ventilation loop of xPLSS that removes contaminants generated by the crewmembers’ metabolic processes. The primary trace contaminants that must be removed include ammonia (NH3), carbon monoxide (CO), formaldehyde (CH2O), and methyl mercaptan (CH3SH). The current state-of-the-art TCC sorbent is non-regenerable activated carbon. As a non-regenerable sorbent, its use negatively impacts the logistics for future missions. Thus, an ideal solution can be a vacuum-regenerable sorbent integrated with the xPLSS CO2/H2O removal system. To test new designs and sorbents, XploSafe has constructed a recirculating test bed that mimics the environment within the xPLSS by providing concentrations of the trace contaminant analytes generated at the operating temperature, humidity, pressure, and flow rates of the xPLSS. This system can perform regeneration or desorption by exposing the sorbent to a pressure swing from 4.3 psia to <1 torr over approximately 2 minutes. Using this test system, XploSafe evaluated various TCC prototypes constructed using rapid prototyping techniques and identified a process that allows vacuum regenerative TCC designs to be quickly examined for flow, pressure drop, and performance. By using toluene as a segregate for volatile organics, this test system was evaluated using both vacuum regenerable and non-regenerable sorbents to demonstrate the operational effectiveness of these sorbents in maintaining the concentrations of the trace contaminant analytes below the 7-day Spacecraft Maximum Allowable Concentrations.

Nicholas Materer↗

On Predicting Transient Pressure in Vacuum Systems Featuring Getter Materials

Getter materials have been used to reduce pressure or partial pressures in a variety of vacuum applications ranging from vacuum tubes to space flight science instruments. Testing of getter materials has tended to emphasize the capacity of candidate materials to collect specific gas species in sufficient quantities to size them in these applications. When determining a getter material’s capacity, it is typically subjected to enough excess target gas to ensure it sorbs as quickly as possible. However, when both the gas source strength and the getter’s sorption rate exhibit transient decay behavior, such data is not sufficient to predict the targeted species’ partial pressure within a vacuum system as a function of time.

M. S. Woronowicz↗

On Predicting Transient Pressure in Vacuum Systems Featuring Getter Materials

Getter materials have been used to reduce pressure or partial pressures in a variety of vacuum applications ranging from vacuum tubes to space flight science instruments. Testing of getter materials has tended to emphasize the capacity of candidate materials to collect specific gas species in sufficient quantities to size them in these applications. When determining a getter material’s capacity, it is typically subjected to enough excess target gas to ensure it sorbs as quickly as possible. However, when both the gas source strength and the getter’s sorption rate exhibit transient decay behavior, such data is not sufficient to predict the targeted species’ partial pressure within a vacuum system as a function of time.

Michael Woronowicz↗

Thermal Vacuum Testing Strategy and Thermal Desktop Model Correlation for the Moon to Mars Planetary Autonomous Construction Technologies (MMPACT) Robotic Terrestrial Arm

This paper discusses the initial thermal vacuum testing of the MMPACT robotic terrestrial arm. The robotic arm is part of a construction system designed for the lunar south pole surface. The first thermal vacuum test was a risk mitigation test to ensure the arm could operate in vacuum, with all other data collection as secondary priorities. 44 thermocouples (TCs) were attached to the arm. Installation was done with additional care to account for both the extra wiring harness weight on the arm with the TC wires and increased focus on stabilizing the TC attachments to the moving components. Thermal steady state of <= 0.01°C/hour was reached for the hot set of testing conditions. This data was used to correlate the Thermal Desktop (TD) model to the test results within +/- 5°C.

Thermal analysis↗

Thermal Vacuum Testing Strategy and Thermal Desktop Model Correlation for the Moon to Mars Planetary Autonomous Construction Technologies (MMPACT) Robotic Terrestrial Arm

This paper discusses the initial thermal vacuum testing of the MMPACT robotic terrestrial arm. The robotic arm is part of a construction system designed for the lunar south pole surface. The first thermal vacuum test was a risk mitigation test to ensure the arm could operate in vacuum, with all other data collection as secondary priorities. 44 thermocouples (TCs) were attached to the arm. Installation was done with additional care to account for both the extra wiring harness weight on the arm with the TC wires and increased focus on stabilizing the TC attachments to the moving components. Thermal steady state of <= 0.01°C/hour was reached for the hot set of testing conditions. This data was used to correlate the Thermal Desktop (TD) model to the test results within +/- 5°C.

Thermal analysis↗

Thermal Design and Thermal Vacuum Testing of the StarBurst Instrument

The StarBurst Multimessenger Pioneer is a small satellite mission serving as a wide-field gamma-ray observatory designed to capture the initial emissions of short gamma-ray bursts, electromagnetic signatures of neutron star mergers. This paper presents the final thermal design and analysis of the StarBurst Instrument, comprising the bus-to-instrument interface plate, control electronics, and twelve crystal detector units, which form the core of the mission’s science capability. The passive thermal control system design requires consideration of restrictive keep-out zones, unknown orbital parameters, and narrow temperature limits of the detectors. Also summarized is the instrument level thermal vacuum cycle test, correlated model refinements, and updated model results. Following successful completion of the instrument test campaign, the hardware was integrated with the spacecraft bus for spacecraft level testing, including additional thermal vacuum testing. The results from the spacecraft level thermal vacuum test will further inform the instrument thermal model, ensuring accurate flight temperature predictions. StarBurst launches as a secondary payload in 2027 and has a mission duration of at least one year.

StarBurst↗

Comparing Vacuum and Extreme Ultraviolet Radiation for Postionization of Laser Desorbed Neutrals from Bacterial Biofilms and Organic Fullerene

Vacuum and extreme ultraviolet radiation from 8 - 24 eV generated at a synchrotron was used to postionize laser desorbed neutrals of antibiotic-treated biofilms and a modified fullerene using laser desorption postionization mass spectrometry (LDPI-MS). Results show detection of the parent ion, various fragments, and extracellular material from biofilms using LDPI-MS with both vacuum and extreme ultraviolet photons. Parent ions were observed for both cases, but extreme ultraviolet photons (16-24 eV) induced more fragmentation than vacuum ultraviolet (8-14 eV) photons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rogue Mode Shileding in NSLS-II Multipole Vacuum Chambers

Modes with transverse electric field (TE-modes) in the NSLS-II multipole vacuum chamber can be generated at frequencies above 450MHz due to its geometric dimensions. Since the NSLS-II BPM system monitors signals within 10 MHz band at RF frequency of 500 MHz, frequencies of higher-order modes (HOM) can be generated within the transmission band of the band pass filter. In order to avoid systematic errors in the NSLS-II BPM system, we introduced frequency shift of HOMs by using RF metal shielding located in the antechamber slot. We demonstrated numerical modeling and experimental studies of the spurious TE modes in the NSLS-II vacuum chambers with antechamber slot. Calculated frequencies of TE-modes in considered chambers with and without RF shielding were verified experimentally. Flexible BeCu RF shielding inside each chamber at proper location shifts frequencies of H{sub 10p}-modes above {approx}900MHz, except chambers S6 odd and even. These chambers need special attention because of synchrotron radiation from downstream magnets. S6 odd multipole vacuum chamber needs to be measured and the RF shielding length has to be optimized. RF shielding looks adequate for baseline design. Fifty percent of open space provides adequate pumping speed.

25mm434mhz↗

Helium pressures in RHIC vacuum cryostats and relief valve requirements from magnet cooling line failure

A catastrophic failure of the RHIC magnet cooling lines, similar to the LHC superconducting bus failure incident, would pressurize the insulating vacuum in the magnet and transfer line cryostats. Insufficient relief valves on the cryostats could cause a structural failure. A SINDA/FLUINT{reg_sign} model, which simulated the 4.5K/4 atm helium flowing through the magnet cooling system distribution lines, then through a line break into the vacuum cryostat and discharging via the reliefs into the RHIC tunnel, had been developed to calculate the helium pressure inside the cryostat. Arc flash energy deposition and heat load from the ambient temperature cryostat surfaces were included in the simulations. Three typical areas: the sextant arc, the Triplet/DX/D0 magnets, and the injection area, had been analyzed. Existing relief valve sizes were reviewed to make sure that the maximum stresses, caused by the calculated maximum pressures inside the cryostats, did not exceed the allowable stresses, based on the ASME Code B31.3 and ANSYS results. The conclusions are as follows: (1) The S/F simulation results show that the highest internal pressure in the cryostats, due to the magnet line failure, is {approx}37 psig (255115 Pa); (2) Based on the simulation, the temperature on the cryostat chamber, INJ Q8-Q9, could drop to 228 K, which is lower than the material minimum design temperature allowed by the Code; (3) Based on the ASME Code and ANSYS results, the reliefs on all the cryostats inside the RHIC tunnel are adequate to protect the vacuum chambers when the magnet cooling lines fail; and (4) In addition to the pressure loading, the thermal deformations, due to the temperature decrease on the cryostat chambers, could also cause a high stress on the chamber, if not properly supported.

43 PARTICLE ACCELERATORS↗

Use of Polycarbonate Vacuum Vessels in High-Temperature Fusion-Plasma Research

Magnetic fusion energy (MFE) research requires ultrahigh-vacuum (UHV) conditions, primarily to reduce plasma contamination by impurities. For radiofrequency (RF)-heated plasmas, a great benefit may accrue from a non-conducting vacuum vessel, allowing external RF antennas which avoids the complications and cost of internal antennas and high-voltage high-current feedthroughs. In this paper we describe these and other criteria, e.g., safety, availability, design flexibility, structural integrity, access, outgassing, transparency, and fabrication techniques that led to the selection and use of 25.4-cm OD, 1.6-cm wall polycarbonate pipe as the main vacuum vessel for an MFE research device whose plasmas are expected to reach keV energies for durations exceeding 0.1 s

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vacuum encapsulated hermetically sealed diamond amplified cathode capsule and method for making same

A vacuum encapsulated, hermetically sealed cathode capsule for generating an electron beam of secondary electrons, which generally includes a cathode element having a primary emission surface adapted to emit primary electrons, an annular insulating spacer, a diamond window element comprising a diamond material and having a secondary emission surface adapted to emit secondary electrons in response to primary electrons impinging on the diamond window element, a first cold-weld ring disposed between the cathode element and the annular insulating spacer and a second cold-weld ring disposed between the annular insulating spacer and the diamond window element. The cathode capsule is formed by a vacuum cold-weld process such that the first cold-weld ring forms a hermetical seal between the cathode element and the annular insulating spacer and the second cold-weld ring forms a hermetical seal between the annular spacer and the diamond window element whereby a vacuum encapsulated chamber is formed within the capsule.

30 DIRECT ENERGY CONVERSION↗