Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “traces”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Design, fabrication and test of a trace contaminant control system

A trace contaminant control system was designed, fabricated, and evaluated to determine suitability of the system concept to future manned spacecraft. Two different models were considered. The load model initially required by the contract was based on the Space Station Prototype (SSP) general specifications SVSK HS4655, reflecting a change from a 9 man crew to a 6 man crew of the model developed in previous phases of this effort. Trade studies and a system preliminary design were accomplished based on this contaminant load, including computer analyses to define the optimum system configuration in terms of component arrangements, flow rates and component sizing. At the completion of the preliminary design effort a revised contaminant load model was developed for the SSP. Additional analyses were then conducted to define the impact of this new contaminant load model on the system configuration. A full scale foam-core mock-up with the appropriate SSP system interfaces was also fabricated.

Source record↗

Space Shuttle Trace Gas Analyzer

A Trace Gas Analyzer (TGA) with the ability to detect the presence of toxic contaminants in the Space Shuttle atmosphere within the subparts-per-million range is under development. The design is a modification of the miniaturized Gas Chromatograph-Mass Spectrometer (GCMS) developed for the Viking Mars Lander. An ambient air sample is injected onto the GC column from a constant volume sample loop and separated into individual compounds for identification by the MS. The GC-MS interface consists of an effluent divider and a silver-paladium separator, an electrochemical cell which removes more than 99.99% of the hydrogen carrier gas. The hydrogen is reclaimed and repressurized without affecting the separator efficiency, a feature which enables a considerable weight reduction in the carrier gas supply system.

Dencker, W.↗

Rb, Sr and strontium isotopic composition, K/Ar age and large ion lithophile trace element abundances in rocks and glasses from the Wanapitei Lake impact structure

Shock metamorphosed rocks and shock-produced melt glasses from the Wanapitei Lake impact structure have been examined petrographically and by electron microprobe. Eleven clasts exhibiting varying degrees of shock metamorphism and eight impact-produced glasses have been analyzed for Rb, Sr and Sr isotopic composition. Five clasts and one glass have also been analyzed for large ion lithophile (LIL) trace element abundances including Li, Rb, Sr, and Ba and the REE's. The impact event forming the Wanapitei Lake structure occurred 37 m.y. ago based on K/Ar dating of glass and glassy whole-rock samples. Rb/Sr isotopic dating failed to provide a meaningful whole-rock or internal isochron. The isotopic composition of the glasses can be explained by impact-produced mixing and melting of metasediments.

Winzer, S. R.↗

Major and trace element chemistry of Boulder 1 at Station 2, Apollo 17

Twenty-seven samples from Boulder 1 at Station 2 are analyzed for major and trace elements by atomic absorption spectrophotometry and neutron activation analysis. Two types of matrix and several types of clast materials are characterized on the basis of their chemistry. It is shown that one matrix type is a common material at the Apollo 17 site, while the other is probably exotic to that site. The most unusual clast materials found are coarse norite (an old rock no longer found in millimeter fragments at the site) and pigeonite basalt (possibly a highland volcanic rock). It is concluded that the boulder-forming process combined materials from at least two different localities or vertical strata.

Blanchard, D. P.↗

History of Boulder 1 at Station 2, Apollo 17 based on trace element interrelationships

Correlations among the trace and minor element pairs Cl and Br, Cl and P2O5, and Ru and Os, present in parent igneous rocks, generally survived the processes of boulder breccia formation. Fractions of Cl, Br, and Hg that are mobilized by water leaching or volatilization at moderate temperatures place constraints on the thermal history of Boulder 1 and its component breccias. Since, and possibly during, consolidation, the boulder has probably not been subjected to temperatures in excess of 450 C. The parent rocks of the Apollo 17 boulder and breccia samples studied could have been derived from two initial magmas. Vapor clouds from apparently external sources permeated the source regions of the boulders.

Jovanovic, S.↗

Equivalence of equations describing trace element distribution during equilibrium partial melting

It is shown that four equations used for calculating the evolution of trace-element abundances during equilibrium partial melting are mathematically equivalent. The equations include those of Hertogen and Gijbels (1976), Shaw (1970), Schilling (1971), and O'Nions and Clarke (1972). The general form to which all these equations reduce is presented, and an analysis is performed to demonstrate their mathematical equivalence. It is noted that the utility of the general equation flows from the nature of equilibrium (i.e., the final state is independent of the path by which that state is attained).

Consolmagno, G. J.↗

Extraction of trace elements from ores

Trace elements, such as interstitial impurities, can be extracted by low-pressure, relatively low-temperature vaporization from compositions in which they occur.

Ikramuddin, M.↗

Trace Gas Analyzer (TGA) program

The design, fabrication, and test of a breadboard trace gas analyzer (TGA) is documented. The TGA is a gas chromatograph/mass spectrometer system. The gas chromatograph subsystem employs a recirculating hydrogen carrier gas. The recirculation feature minimizes the requirement for transport and storage of large volumes of carrier gas during a mission. The silver-palladium hydrogen separator which permits the removal of the carrier gas and its reuse also decreases vacuum requirements for the mass spectrometer since the mass spectrometer vacuum system need handle only the very low sample pressure, not sample plus carrier. System performance was evaluated with a representative group of compounds.

Source record↗

In situ measurements of Arctic atmospheric trace constituents from an aircraft

In situ measurements of the ambient concentrations of several atmospheric trace constituents were obtained using instruments installed on board the NASA Convair 990 aircraft at altitudes up to 12.5 kilometers over Alaska and the Arctic Ocean. Concentration data on ozone, carbon monoxide, water vapor, and particles larger than 0.5 micrometer in diameter were acquired.

Reck, G. M.↗

A measurement system for the atmospheric trace gases CH4 and CO

A system for measuring ambient clean air levels of the atmospheric trace gases methane and carbon monoxide is described. The analytical method consists of a gas chromatographic technique that incorporates sample preconcentration with catalytic conversion of CO to CH4 and subsequent flame ionization detection of these gases. The system has sufficient sensitivity and repeatability to make the precise measurements required to establish concentration profiles for CO and CH4 in the planetary boundary layer. A discussion of the bottle sampling program being conducted to obtain the samples for the concentration profiles is also presented.

Condon, E. P.↗

A dispersion model approach to the preliminary design of adsorber beds for trace contaminants

It is shown that a dispersion model for the transport of a gas through a porous medium can be useful in the preliminary design of adsorber beds for the control of trace contaminants. The transmission function is considered, taking into account the transmission of 102-ppm acetaldehyde in helium flowing at various flow rates through an absorber bed. The experiments were conducted at a temperature of 25.0 C. Attention is given to a representation of the experimental breakthrough curve, the volume adsorption capacity, temperature studies, and correlations.

Madey, R.↗

CO2 and humidity removal system for extended Shuttle missions - CO2, H2O, and trace contaminant equilibrium testing

The equilibrium relationships for the co-adsorption of CO2 and H2O on an amine coated acrylic ester are presented. The equilibrium data collection and reduction techniques are discussed. Based on the equilibrium relationship, other modes of operation of systems containing HS-C are discussed and specific space applications for HS-C are presented. Equilibrium data for 10 compounds which are found as trace contaminants in closed environments are also presented.

Davis, S. H.↗

Volatile/mobile trace elements in Karoonda /C4/ chondrite

Concentrations of ten volatile/mobile trace elements and of nonvolatile Co in the Karoonda (C4) meteorite were determined, and the atomic abundances relative to C1 are compared with values for the Murchison (C2) and Allende (C3) meteorites. Empirical Bi, In, and Tl data for Karoonda and heated Allende and Murchison are compared with theoretical curves for condensation from a gas of cosmic composition at low pressures. It is suggested that Karoonda might derive from low-temperature open-system metamorphism of pristine C3-like material.

Matza, S. D.↗

Low-background trace-gas detector

Spectrophone detects very small concentrations of trace gases. With gas in sample cell, laser is tuned to absorption line of interest. Molecular absorption in cell produces pulsed acoustical pressure at chopper frequency. Two optical paths with very different absorption lengths are used to pretune cell to balance out background absorption by cell windows.

Rosengren, L.↗

Spacelab baseline ECS trace contaminant removal test program

An estimate of the Spacelab Baseline Environmental Control System's contaminated removal capability was required to allow determination of the need for a supplemental trace contaminant removal system. Results from a test program to determine this removal capability are presented.

Ray, C. D.↗

The capability of satellite borne remote sensors to measure stratospheric trace constituents. Volume 1: Background and requirements

Volume 1 of a three volume report issued as MITRE/METREX Technical Report is presented. This volume contains a synthesis of the results of two previous MITRE/METREX studies and an update of the information. These studies deal with a comprehensive review of stratospheric trace constituent measurement requirements. The scope of the study was restricted to those contituents which fall into the general category of air pollutants.

Keitz, E. L.↗

The capability of satellite borne remote sensors to measure stratospheric trace constituents. Volume 2: Ozone and aerosol related missions

Stratospheric trace constituent measurement requirements are separated into two somewhat overlapping areas. In the first area, it is assumed that the only problem of interest is ozone; its chemistry chain, environmental effects and measurement requirements. In like manner, in the second area it is assumed that the only problem of interest is stratospheric aerosols; their chemistry, effects and measurement requirements.

Keitz, E. L.↗