Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “total variation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Further interpretation of satellite measurements of Antarctic total ozone

Both dynamical and chemical mechanisms have been advanced to explain the decrease in total ozone in the Antarctic spring. Further analysis of satellite measurements show that during any one year, the September decline in total ozone near the South Pole is compensated by an increase at midlatitudes. The total ozone amount from 44 deg S to the pole remains almost unchanged from August through November even though both the polar and midlatitude values reach extremes during this period. These observations suggest that the variations within the spring season in south polar total ozone are governed by dynamical redistribution rather than chemical processes.

Stolarski, Richard S.↗

Spatial variations in tropical ozone - The influence of meridional transport and planetary waves in the stratosphere

The backscatter ultraviolet instrument on the Atmosphere Explorer-E satellite has acquired a large body of stratospheric and total ozone data in the tropical region. The latitudinal variation of the ozone mixing ratio on constant pressure surfaces shows the transition from chemical domination to transport control between 5 and 10 mb. Spectral analysis of the longitudinal O3 structure reveals large wavenumber 1 and 2 patterns, although considerable activity in wavenumbers 5 through 7 sometimes appears. Longitudinal structure increases with decreasing pressure between 30 and 5 mb. The spatial variability near 5 mb must reflect similar structure in the odd nitrogen distribution which provides the major loss mechanism for ozone at this level.

Frederick, J. E.↗

Flame radiation

Total radiation and heat flux data was obtained on a combustor liner by advanced instrumentation. If the results obtained by the special instrumentation are considered to be representative of the total radiation and heat flux, then the effect of variation of engine operating parameters and of fuel type can be more easily obtained. The special instrumentation used for these investigations consisted of five total radiometers and two total heat flux gages. The radiometers were arranged axially and circumferentially through sliding air seals in the outer liner. The two heat flux gages were welded in the outer liner between two circumferential radiometers. Static pressures were obtained on both the cold and the hot side of the outer liner in the area of the heat flux gages. Liner metal temperatures were also obtained. The combustor inlet pressure was varied over a nominal range of 0.5 to 2.07 MPa, inlet air temperature from 550 to 670 K, and fuel-air ratio from about 0.015 to 0.040. The two fuels tested were ASTM Jet A and a fuel designated as ERBS V. Results of the tests are discussed.

Wear, J. D.↗

A test of water vapor radiometer-based troposphere calibration using VLBI observations on a 21-kilometer baseline

Simultaneous very long baseline interferometry (VLBI) and water vapor radiometer (WVR) measurements on a 21 km baseline showed that calibration by WVRs removed a significant fraction of the effect of tropospheric delay fluctuations for these experiments. From comparison of the residual delay variations within scans and between scans, the total tropospheric contribution t the delay residuals for each of the three 5 to 20 hour sessions was estimated as 1, 17, and 10%, with the first value being uncertain. The observed improvement in rms residual delay from WVR calibration during these three sessions was 4, 16, and 2%, respectively. The improvement is consistent with the estimated 2 to 3 mm path delay precision of current WVRs. The VLBI measurements, of natural radio sources, were conducted in April and May 1993 at Goldstone, California. Dual-frequency (2.3 and 8.4 GHz) observations were employed to remove the effects of charged particles from the data. Measurements with co-pointed WVRs, located within 50 m of the axis of each antenna, were performed to test the ability of the WVRs to calibrate line-of-sight path delays. Factors that made WVR performance assessment difficult included (1) the fact that the level of tropospheric fluctuations was smaller than is typical for Goldstone during these experiments and (2) VLBI delay variations on longer time scales (i.e., over multiple scans) contained uncalibrated instrumental effects (probably a result of slow temperature variations in the VLBI hardware) that were larger than the tropospheric effects.

Linfield, R. P.↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Diurnal variation of stratospheric chlorine monoxide - A critical test of chlorine chemistry in the ozone layer

Ground-based observations of a mm-wave spectral line at 278 GHz have yielded stratospheric chlorine monoxide column density diurnal variation records which indicate that the mixing ratio and column density of this compound above 30 km are about 20 percent lower than model predictions based on 2.1 parts/billion of total stratospheric chlorine. The observed day-to-night variation is, however, in good agreement with recent model predictions, both confirming the existence of a nighttime reservoir for chlorine and verifying the predicted general rate of its storage and retrieval.

Solomon, P. M.↗

Accuracy of ghost rotationally invariant slave-boson and dynamical mean field theory as a function of the impurity-model bath size

Here, we compare the accuracy of the ghost rotationally invariant slave-boson (g-RISB) theory and dynamical mean field theory (DMFT) on the single-band Hubbard model, as a function of the number of bath sites in the embedding impurity Hamiltonian. Our benchmark calculations confirm that the accuracy of g-RISB can be systematically improved by increasing the number of bath sites, similar to DMFT. With a few bath sites, we observe that g-RISB is systematically more accurate than DMFT for the ground-state observables. On the other hand, the relative accuracy of these methods is generally comparable for the quasiparticle weight and the spectral function. As expected, we observe that g-RISB satisfies the variational principle in infinite dimensions, as the total energy decreases monotonically towards the exact value as a function of the number of bath sites, suggesting that the g-RISB wave function may approach the exact ground state in infinite dimensions. Our results suggest that the g-RISB is a promising method for first-principles simulations of strongly correlated matter, which can capture the behavior of both static and dynamical observables, at a relatively low computational cost.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Antioxidant Activity, Microbiological Quality, and Acceptability of Spontaneously Fermented Shrimp Sausage (Litopenaeus vannamei)

Fermented shrimp sausages are prepared spontaneously with Litopenaeus vannamei as raw material. Shrimp is one of the marine sources with rich chitosan as bioactive compounds, antioxidants, vitamin E, and probiotic lactic acid bacteria (LAB) produced by fermentation processes. This study aimed to analyze the variations in antioxidant activity, vitamin E content, total LAB, total pathogenic bacteria, pH, and acceptability of shrimp sausage produced at different fermentation times. A completely randomized experimental design study was performed using four levels of exposure time, including control (0 days), 1, 2, and 3 days. The treatment was conducted spontaneously with 1.2% salt concentration, a drying temperature of 50°C for 3 h, and fermentation at 35°C. The evaluated parameters included the antioxidant activity measured with the radical 2,2-azino-bis (3-ethylbenzothiazoline-6-sulphonic acid) method, vitamin E levels by high-performance liquid chromatography, total LAB with total plate count, and Escherichia coli bacteria by the most probable number method. Salmonella sp. and Staphylococcus aureus were estimated by the identification method. A pH meter was used to assess acidity, and hedonic organoleptic testing was performed for taste, aroma, color, and texture. The results show significant differences in antioxidant activity, vitamin E, and shrimp sausage acceptability at varied fermentation times p ≤ 0.05 . However, the best formulation was obtained with the first-day fermented shrimp sausage, as shown by its bioactive content and the level of acceptability.

Afifah, Diana N.↗

Theoretical study of corrugated plates: Shear stiffness of a trapezoidally corrugated plate with discrete attachments to a rigid flange at the ends of the corrugations

Analysis and numerical results are presented for the elastic shear stiffness of a corrugated shear web with a certain type of discrete attachments at the ends of the trough lines of the corrugations, namely point attachments to a rigid flange which interferes with the deformations of the end cross sections by preventing downward movement but permitting upward (lifting off) movement. The analysis is based on certain assumed modes of deformation of the cross sections in conjunction with the method of minimum total potential energy and the calculus of variations in order to obtain equations for the manner in which the assumed modes of deformation vary along the length of the corrugation. The numerical results are restricted to the case of equal-width crests and troughs but otherwise apply to a wide variety of geometries. They are in the form of graphs which give the overall shear stiffness as a fraction of the overall shear stiffness that could be obtained by having continuous attachment at the ends of the corrugations.

Hsiao, C.↗

Survey of recent work on the analysis of discretely attached corrugated shear webs.

Summary and progress report of more recent work by the author and his students on the theoretical analysis of stiffness, stresses, and deformations of corrugated shear webs with discrete, rather than continuous, attachment between the ends of the corrugations and the surrounding members. Various kinds of discrete attachment are considered, and two kinds of corrugation cross section: the trapezoidal and the curvilinear, the latter having crests and valleys made up of identical circular arcs. The more recent analyses employ the method of minimum total potential energy and the calculus of variations to obtain differential equations and boundary conditions governing the longitudinal variation of various component modes used to describe the deformations of a cross section. They are believed to be more accurate than earlier analyses in that they generally permit more degrees of freedom in the assumed deformations. In particular, they abandon the assumption, characteristic of the earlier analyses, that the straight-line generators of the corrugation remain straight during the shearing of the web.

Libove, C.↗

Individual radiosensitivity and its daily variations

The effectiveness of determining individual radiosensitivity of rats by total gas exchange measurements, studies of Na/K content in urine, and the reaction of leukocytes to intra-abdominal administration of epinephrine, was studied. The most indicative results of predicting individual reaction to radiation were obtained by the leukocyte reaction to epinephrine load; however, changes in the leukocyte content of peripheral blood after epinephrine administration depended on the initial level during the day.

Druzhinin, Y. N.↗

Feasibility of SiC composite structures for 1644 deg gas turbine seal applications

The feasibility of silicon carbide composite structures was evaluated for 1644 K gas turbine seal applications. The silicon carbide composites evaluated consisted of Si/SiC Silcomp (Trademark) - and sintered silicon carbide as substrates, both with attached surface layers containing BN as an additive. A total of twenty-eight candidates with variations in substrate type and density, and layer chemistry, density, microstructure, and thickness were evaluated for abradability, cold particle erosion resistance, static oxidation resistance, ballistic impact resistance, and fabricability. The BN-free layers with variations in density and pore size were later added for evaluation. The most promising candidates were evaluated for Mach 1.0 gas oxidation/erosion resistance from 1477 K to 1644 K. The as-fabricated rub layers did not perform satisfactorily in the gas oxidation/erosion tests. However, preoxidation was found to be beneficial in improving the hot gas erosion resistance. Overall, the laboratory and rig test evaluations show that material properties are suitable for 1477 K gas turbine seal applications.

Darolia, R.↗

A computer code for performance of spur gears

In spur gears both performance and failure predictions are known to be strongly dependent on the variation of load, lubricant film thickness, and total flash or contact temperature of the contacting point as it moves along the contact path. The need of an accurate tool for predicting these variables has prompted the development of a computer code based on recent findings in EHL and on finite element methods. The analyses and some typical results which to illustrate effects of gear geometry, velocity, load, lubricant viscosity, and surface convective heat transfer coefficient on the performance of spur gears are analyzed.

Wang, K. L.↗

Effect of buoyancy and power design parameters on hybrid airship performance

The effects of several design parameters on the performance of hybrid airships having rotors and propellers were examined with a simple mathematical model. The parameters included buoyancy ratio, Froude number, ratio of rotor power to total power, and rotor shaft tilt. Performance variations resulting from changes in these parameters were calculated, and are presented and discussed. Performance quantities included best climb rate, equivalent vehicle L/D, and maximum speed. Performance at all speeds between hover and maximum speed was found to be sensitive to power distribution between rotors and propellers, and to rotor shaft tilt.

Talbot, P. D.↗

The large scale gas and dust distribution in the galaxy: Implications for star formation

Infrared Astronomy Observations are presented for the diffuse infrared (IR) emissions from the galactic plane at wavelengths of 60 and 100 microns and the total far infrared intensity and its longitudinal variations in the disk were derived. Using available CO, 5 GHz radio-continuum, and HI data, the IR luminosity per hydrogen mass and the ingrared excess (IRE) ratio in the Galaxy were derived. The longitudinal profiles of the 60 and 100 micron emission were linearly decomposed into three components that are associated with molecular (H2), neutral (HI), and ionized (HII) phases in the interstellar medium (ISM), and the relevant dust properties were derived in each phase. Implications of the findings for various models of the diffuse IR emisison and for star formation in the galactic disk are discussed.

Sodroski, T. J.↗

A numerical study of three-dimensional vortex breakdown

A numerical simulation of bubble-type vortex breakdown using a unique discrete form of the full 3-D, unsteady incompressible Navier-Stokes equations was performed. The Navier-Stokes equations were written in a vorticity-velocity form and the physical problem was not restricted to axisymmetric flow. The problem was parametized on a Rossby- Reynolds-number basis. Utilization of this parameter duo was shown to dictate the form of the free-field boundary condition specification and allowed control of axial breakdown location within the computational domain. The structure of the breakdown bubble was studied through time evolution plots of planar projected velocity vectors as well as through plots of particle traces and vortex lines. These results compared favorably with previous experimental studies. In addition, profiles of all three velocity components are presented at various axial stations and a Fourier analysis was performed to identify the dominant circumferential modes. The dynamics of the breakdown process were studied through plots of axial variation of rate of change of integrated total energy and rate of change of integrated enstrophy, as well as through contour plots of velocity, vorticity and pressure.

Spall, Robert E.↗