Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Delay line anodes for microchannel-plate spectrometers

A photon-counting readout system for microchannel-plate spectrometers is described that uses a delay line and timing circuit for the wavelength coordinate and a wedge-wedge charge division system for the orthogonal spatial coordinate. A novel zigzag layout allows these two anode patterns to coexist on a common planar substrate and share the charge from each photoevent, thereby simultaneously localizing the photon in each of its two dimensions. Unlike wedge-and-strip or resistive anode encoders, the delay line offers a spatial resolution that is relatively independent of the format length. Unlike discrete anode systems, the delay line readout system's complexity is also independent of the field of view size. These facts make the delay line readout system advantageous in large format detectors. A testbed detector having a delay line propagation speed of 2.2 mm/ns and a time resolution of 33 ps FWHM has been assembled. Ultraviolet testing shows a Gaussian event distribution having a 70-micron FWHM width; the readout system blur contribution is less than 50-micron FWHM.

Lampton, M.↗

Epithermal Neutron Evidence for a Diurnal Surface Hydration Process in the Moon's High Latitudes

We report evidence from epithermal neutron flux observations that show that the Moon's high latitude surfaces are being actively hydrated, dehydrated and rehydrated in a diurnal cycle. The near-surface hydration is indicated by an enhanced suppression of the lunar epithermal neutron leakage flux on the dayside of the dawn terminator on poleward-facing slopes (PFS). At 0600 to 0800 local-time, hydrogen concentrations within the upper 1 meter of PFS are observed to be maximized relative to equivalent equator-facing slopes (EFS). During the lunar day surface hydrogen concentrations diminish towards dusk and then rebuild overnight. Surface hydration is determined by differential comparison of the averaged EFS to PFS epithermal neutron count rates above +/- 75 deg latitude. At dawn the contrast bias towards PFS is consistent with at least 15 to 25 parts-per-million (ppm) hydrogen that dissipates by dusk. We review several lines of evidence derived from temperature and epithermal neutron data by a correlated analysis of observations from the Lunar Reconnaissance Orbiter's (LRO) Lunar Exploration Neutron Detector (LEND) that were mapped as a function of lunar local-time, Lunar Observing Laser Altimeter (LOLA) topography and Diviner (DLRE) surface temperature.

diurnal cycles↗

Super active regions and production of major solar flares

The success of imaging detectors with small fields of veiw such as HXIS or P/OF (Pinhole/Occulter Facility) depends heavily on pointing to the right place at the right time. During the solar maximum years many active regions coexist on the solar disk. Therefore, in order to point the imaging detector to the right place, it is important to know which active region is most likely to produce major flares. This knowledge is also important for flare prediction. As a first step toward this goal active regions have been identified which produced major flares observed by HXRBS (Hard X-Ray Burst Spectrometer) on SMM during February 1980 through December 1983. For this study the HXRBS Event List, an updated flare list compiled by the HXRBS group, and the Comprehensive Reports of the Solar Geophysical Data were used. During this period, HXRBS detected hard X-rays from approx 7000 solar flares, out of which only 441 flares produced X-rays with peak count rates exceeding 1000 counts/s. Flares with such high peak count rates are major flares. During the same time period about 2100 active regions passed across the solar disk, out of which only 153 were observed to produce major flares. (Some active regions are known to persist for several solar rotations, but at each passage new active region numbers are assigned and the estimate is based on active region numbers.) Out of these 153 active regions, 25 were observed to produce 5 or more major flares. Considering their high productivity of major flares, we may call these active regions super active regions. These 25 super active regions produced 209 major flares, accounting for 51% of all the major flares with identified active regions.

Bai, T.↗

Second generation detector for low order global solar oscillations

The first observations of long period low order global solar oscillations grew out of diameter measurements made over an extended period of time. As a result of these investigations, a detailed understanding of the surface properties of the oscillations evolved, allowing development of a second generation detector. This new detector, currently under development directly utilizes various surface properties of the oscillations and does not, therefore, directly involve diameter measurements. The specifications of the detector, its supporting telescope and the observing program are reviewed.

Forbes, F. F.↗

Testing methods and techniques: Quality control and nondestructive testing: A complication

A variety of devices and techniques useful in nondestructive testing is described. Ranging in complexity from an automated ultrasonic testing system designed for complex laminated honeycomb structures, to a flexible leak detector probe, the items represent either potential savings in cost and time, or improvement in inspection quality over past techniques. Data cover weld and braze inspection, leak detection, and inspection of composite materials.

Source record↗

Feasibility of an on-line fission-gas-leak detection system

Calculations were made to determine if a cladding failure could be detected in a 100-kW zirconium hydride reactor primary system by monitoring the highly radioactive NaK coolant for the presence of I-131. The system is to be completely sealed. A leak of 0.01 percent from a single fuel pin was postulated. The 0.364-MeV gamma of I-131 could be monitored on an almost continuous basis, while its presence could be varified by using a longer counting time for the 0.638-MeV gamma. A lithium-drifted germanium detector would eliminate radioactive corrosion product interference that could occur with a sodium iodide scintillation detector.

Lustig, P. H.↗

The ISEE-C gamma ray burst spectrometer

The technical properties, operation, and expected sensitivity are discussed for an experiment intended to search for narrow lines in the spectra of gamma ray bursts during the ISEE-C mission. At the heart of the experiment is a radiatively cooled germanium solid state photon detector. The instrumentation is capable of storing the entire spectrum of all but the largest bursts in the energy range 0.05-6.5 MeV. In addition, it analyzes the signals from two CsI detectors in two other experiments on the spacecraft and records event time histories from these to a few millisecond accuracy. A background mode permits spectral analysis during quiet times and will allow the determination of physically interesting upper limits for narrow lines in the diffuse gamma ray background radiation.

Teegarden, B. J.↗

Recent results from observations of 4U1700-37 using SAS-3

SAS-3 observations of a complete orbital cycle (approximately 3.5 d) of the X-ray source 4U1700-37 are presented. A persistent, approximately sinusoidal modulation of approximately 60% amplitude is present in the data at 97 m. Satellite orbital effects are ruled out by using other detectors pointed away from the source but sampled at the same time. The effect of such a long rotation period (if indeed the period is rotational) on current ideas involving accretion torques and stellar wind is discussed.

Matilsky, T.↗

The discovery of a 97 minute periodicity in 4U 1700-37

SAS 3 observations of a complete orbital cycle (about 3.5 days) of the X-ray source 4U 1700-37 are presented. A persistent, approximately sinusoidal modulation of about 60% amplitude is present in the data at 97 minutes. Satellite orbital effects are ruled out by using other detectors pointed away from the source but sampled at the same time. The effect of such a long rotation period (if indeed the period is rotational) on current ideas involving accretion torques and stellar wind is discussed.

Matilsky, T.↗

Phase Detector for Power-Factor Controller

Positive feedback assures reliable switching. Three Phase Power Factor Controller includes three phase detectors, each produces rectangular waves of duration approximately equal to lag time between line voltage and motor current.

Nola, F. J.↗

Manned Mars mission solar physics: Solar energetic particle prediction and warning

There are specific risks to the crew of the manned Mars mission from energetic particles generated by solar activity. Therefore, mission planning must provide for solar monitoring and solar activity forecasts. The main need is to be able to anticipate the energetic particle events associated with some solar flares and, occasionally, with erupting filaments. A second need may be for forecasts of solar interference with radio communication between the manned Mars mission (during any of its three phases) and Earth. These two tasks are compatible with a small solar observatory that would be used during the transit and orbital phases of the mission. Images of the Sun would be made several times per hour and, together with a solar X-ray detector, used to monitor for the occurrence of solar activity. The data would also provide a basis for research studies of the interplanetary medium utilizing observations covering more of the surface of the Sun than just the portion facing Earth.

Suess, S. T.↗

Coronagraph observations and analyses of the ultraviolet solar corona

The major activities on the Spartan Ultraviolet Coronal Spectrometer project include both scientific and experimental/technical efforts. In the scientific area, a detailed analysis of the previously reported Doppler dimming of HI Ly-alpha from the July 1982 rocket flight has determined an outflow velocity at 2 solar radii from sun center to be between 153 and 251 km/s at 67 percent confidence. The technical activities include, several improvements made to the instrument that will result in enhanced scientific performance or in regaining a capability that had deteriorated during the delay time in the launch date. These include testing and characterizing the detector for OVI radiation, characterizing a serrated occulter at UV and visible wavelengths, fabricating and testing telescope mirrors with improved edges, testing and evaluating a new array detector system, modifying the slit mask mechanism and installing a mask in the instrument to block the Ly-alpha resonance line when the electron scattered component is being observed.

Kohl, John L.↗

Dipole analysis on EGRET data of extragalactic gamma ray background radiation

A dipole analysis on the EGRET (Energetic Gamma-Ray Experimental Telescope) data seems to be one of the numerous subjects that can be investigated for the extragalactic gamma ray background radiation. By the end of the first one and half years after launch, the all-sky survey program of GRO (Gamma Ray Observatory) will be completed. The EGRET detector will cover the full sky area fairly well by that time. A set of gamma ray data suitable for dipole moment calculations will be available. Furthermore, there now exist in the literature several dipole anisotropy results calculated for optical and infrared observations on the distribution of galaxies in the full sky. The results of dipole moment analysis from gamma ray observation can be compared with those at other wavebands, and hopefully some deeper understanding can be gained on the large scale structure of the Universe.

Lin, Ying-Chi↗

Airborne Calibration Of An Orbiting Radiometer

Experiment demonstrates feasibility of using recently calibrated airborne radiometer to calibrate satellite-borne radiometer monitoring Earth and not calibrated since before launch. Calibration technique helps to assure Earth scientists of accuracy of satellite radiometric measurements taken during long time. Optical train of orbiting radiometer degraded slowly and sensitivities of detectors and gains of amplifiers changed slowly in outer-space environment, but frequent calibrations by airborne-radiometer technique make it possible to compensate for these changes.

Smith, Gilbert R.↗

Long-wavelength PtSi infrared detectors fabricated by incorporating a p(+) doping spike grown by molecular beam epitaxy

By incorporating a 1-nm-thick p(+) doping spike at the PtSi/Si interface, we have successfully demonstrated extended cutoff wavelengths of PtSi Schottky infrared detectors in the long wavelength infrared (LWIR) regime for the first time. The extended cutoff wavelengths resulted from the combined effects of an increased electric field near the silicide/Si interface due to the p(+) doping spike and the Schottky image force. The p(+) doping spikes were grown by molecular beam epitaxy at 450 C, using elemental boron as the dopant source, with doping concentrations ranging from 5 x 10 exp 19 to 2 x 10 exp 20/cu cm. Transmission electron microscopy indicated good crystalline quality of the doping spikes. The cutoff wavelengths were shown to increase with increasing doping concentrations of the p(+) spikes. Thermionic emission dark current characteristics were observed and photoresponses in the LWIR regime were demonstrated.

Lin, T. L.↗

BATSE observations of gamma-ray burst spectra. I - Spectral diversity

We studied the time-averaged gamma-ray burst spectra accumulated by the spectroscopy detectors of the Burst and Transient Source Experiment. The spectra are described well at low energy by a power-law continuum with an exponential cutoff and by a steeper power law at high energy. However, the spectral parameters vary from burst to burst with no universal values. The break in the spectrum ranges from below 100 keV to more than 1 MeV, but peaks below 200 keV with only a small fraction of the spectra breaking above 400 keV; it is therefore unlikely that a majority of the burst spectra are shaped directly by pair processes, unless bursts originate from a broad redshift range. The correlations among burst parameters do not fulfill the predictions of the cosmological models of burst origin. No correlations with burst morphology or the spatial distribution were found. We demonstrate the importance of using a complete spectral description even if a partial description (e.g., a model without a high-energy tail) is statistically satisfactory.

Band, D.↗

Surface Passivation of CdZnTe Detector by Hydrogen Peroxide Solution Etching

The spectral resolution of room temperature nuclear radiation detectors such as CdZnTe is usually limited by the presence of conducting surface species that increase the surface leakage current. Studies have shown that the leakage current can be reduced by proper surface preparation. In this study, we try to optimize the performance of CdZnTe detector by etching the detector with hydrogen peroxide solution as function of concentration and etching time. The passivation effect that hydrogen peroxide introduces have been investigated by current-voltage (I-V) measurement on both parallel strips and metal-semiconductor-metal configurations. The improvements on the spectral response of Fe-55 and 241Am due to hydrogen peroxide treatment are presented and discussed.

Hayes, M.↗