Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “test effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Evaporative Cooling and Dehumidification Garment for Portable Life Support Systems

This paper describes the design and development of an innovative thermal and humidity control system for future space suits. The system comprises an evaporation cooling and dehumidification garment (ECDG) and a lithium chloride absorber radiator (LCAR). The ECDG absorbs heat and water vapor from inside the suit pressure garment, while the LCAR rejects heat to space without venting water vapor. The ECDG is built from thin, flexible patches with coversheets made of non-porous, water-permeable membranes that -enclose arrays of vapor flow passages. Water vapor from inside the spacesuit diffuses across the water permeable membranes, enters the vapor flow channels, and then flows to the LCAR, thus dehumidifying the internal volume of the space suit pressure garment. Additional water evaporation inside the ECDG provides cooling for sensible heat loads. -The heat released from condensation and absorption in the LCAR is rejected to the environment by thermal radiation. We have assembled lightweight and flexible ECDG pouches from prototypical materials and measured their performance in a series of separate effects tests under well-controlled, prototypical conditions. Sweating hot plate tests at typical space suit pressures show that ECDG pouches can absorb over 60 W/ft of latent heat and 20 W/ft of sensible heat from the pressure garment environment. These results are in good agreement with the predictions of our analysis models.

Izenson, Michael↗

Open Rotor Tone Shielding Methods for System Noise Assessments Using Multiple Databases

Advanced aircraft designs such as the hybrid wing body, in conjunction with open rotor engines, may allow for significant improvements in the environmental impact of aviation. System noise assessments allow for the prediction of the aircraft noise of such designs while they are still in the conceptual phase. Due to significant requirements of computational methods, these predictions still rely on experimental data to account for the interaction of the open rotor tones with the hybrid wing body airframe. Recently, multiple aircraft system noise assessments have been conducted for hybrid wing body designs with open rotor engines. These assessments utilized measured benchmark data from a Propulsion Airframe Aeroacoustic interaction effects test. The measured data demonstrated airframe shielding of open rotor tonal and broadband noise with legacy F7/A7 open rotor blades. Two methods are proposed for improving the use of these data on general open rotor designs in a system noise assessment. The first, direct difference, is a simple octave band subtraction which does not account for tone distribution within the rotor acoustic signal. The second, tone matching, is a higher-fidelity process incorporating additional physical aspects of the problem, where isolated rotor tones are matched by their directivity to determine tone-by-tone shielding. A case study is conducted with the two methods to assess how well each reproduces the measured data and identify the merits of each. Both methods perform similarly for system level results and successfully approach the experimental data for the case study. The tone matching method provides additional tools for assessing the quality of the match to the data set. Additionally, a potential path to improve the tone matching method is provided.

Bahr, Christopher J.↗

Evaluation of Large Volume SrI2(Eu) Scintillator Detectors

There is an ever increasing demand for gamma-ray detectors which can achieve good energy resolution, high detection efficiency, and room-temperature operation. We are working to address each of these requirements through the development of large volume SrI{sub 2}(Eu) scintillator detectors. In this work, we have evaluated a variety of SrI{sub 2} crystals with volumes >10 cm{sup 3}. The goal of this research was to examine the causes of energy resolution degradation for larger detectors and to determine what can be done to mitigate these effects. Testing both packaged and unpackaged detectors, we have consistently achieved better resolution with the packaged detectors. Using a collimated gamma-ray source, it was determined that better energy resolution for the packaged detectors is correlated with better light collection uniformity. A number of packaged detectors were fabricated and tested and the best spectroscopic performance was achieved for a 3% Eu doped crystal with an energy resolution of 2.93% FWHM at 662keV. Simulations of SrI{sub 2}(Eu) crystals were also performed to better understand the light transport physics in scintillators and are reported. This study has important implications for the development of SrI{sub 2}(Eu) detectors for national security purposes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Use of DRACS to Enhance HTGRs Passive Safety and Economy

This paper discusses the use of DRACS to Enhance HTGRs Passive Safety and Economy. One of the important requirements for Gen. IV High Temperature Gas Cooled Reactors (HTGR) is passive safety. Currently all the HTGR designs use Reactor Vessel Auxiliary Cooling System (RVACS) for passive decay heat removal. [1] The decay heat first is transferred to core barrel by conduction and radiation, and then to reactor vessel by thermal radiation and convection; finally the decay heat is transferred to natural circulated air or water systems. RVACS can be characterized as a surface based decay heat removal system. Similar concepts have been widely used in sodium cooled fast reactor (SFR) designs, advanced light water reactors like AP1000. The RVACS is especially suitable for smaller power reactors since small systems have relatively larger surface area. RVACS tends to be less expensive. However, it limits the largest achievable power level for modular HTGRs due to the mismatch between the reactor power (proportional to volume) and decay heat removal capability (proportional to surface). When the relative decay heat removal capability is reduced, the peak fuel temperature increases, even close to the design limit. Annual designs with internal reflector can mitigate this effect therefore further increase the power. Another way to increase power is to increase power density. However, it is also limited by the decay heat removal capability. Besides safety, HTGRs also need to be economical in order to compete with other reactor designs. The limit of decay heat removal capability set by using RVACS has affected the economy of HTGRs. Forsberg [2] pointed out other disadvantages of using RVACS such as conflicting functional requirements for the reactor vessel and scaling distortion for integral effect test of the system performance. A potential alternative solution is to use a volume based passive decay removal system, call Direct Reactor Auxiliary Cooling Systems (DRACS), to remove or mitigate the limitation on decay heat removal capability. DRACS has been widely used in SFR designs and in liquid salt cooled high temperature reactors. The containment cooling system in BWR is another example of volume based decay removal systems. DRACS composes of natural circulation loops with two sets of heat exchangers, one in reactor side and another is in environment side. DRACS has the benefits of increasing the power as needed (scalability) and modularity. This paper introduces the concept of using DRACS to enhance HTGRs passive safety and economy.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impact of Rheological Modifiers on Various Slurries Supporting DOE Waste Processing

Controlling the stability and subsequent rheological properties of slurries has been an important but challenging issue in nuclear waste treatment, one that previous research has yet to sufficiently address. At the Hanford and Savannah River sites, operation of the waste treatment facilities at increased solids loading reduces the evaporative load on the melter systems and thereby increases waste processing rates. However, at these higher solids loadings, increased slurry rheology becomes a significant processing issue. The current study evaluates the use of several rheological modifiers to alleviate increased slurry rheology at high waste solids concentrations. Rheological modifiers change particle interactions in slurry. For colloidal slurries, modifiers mainly alter the electrostatic and steric interactions between particles, leading to a change in slurry rheology. Weak organic acid type rheological modifiers strengthen electrostatic repulsion whereas nonionic/polymer surfactant type rheological modifiers introduce a steric repulsion. We investigated various rheological modifiers using high level waste (HLW) nuclear waste simulants characterized typically by high ionic strength and a wide range of pH from 4 to 13. Using rheological analysis, it was found that citric acid and polyacrylic acid would be good rheological modifiers for the HLW simulants tested, effectively reducing slurry rheology by 40% or more. Physical insights into the mechanisms driving stabilization by these rheological modifiers will be discussed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Large Volume SrI2(Eu) Scintillator Detectors

There is an ever increasing demand for gamma-ray detectors which can achieve good energy resolution, high detection efficiency, and room-temperature operation. We are working to address each of these requirements through the development of large volume SrI2(Eu) scintillator detectors. In this work, we have evaluated a variety of SrI2 crystals with volumes >10 cm3. The goal of this research was to examine the causes of energy resolution degradation for larger detectors and to determine what can be done to mitigate these effects. Testing both packaged and unpackaged detectors, we have consistently achieved better resolution with the packaged detectors. Using a collimated gamma-ray source, it was determined that better energy resolution for the packaged detectors is correlated with better light collection uniformity. A number of packaged detectors were fabricated and tested and the best spectroscopic performance was achieved for a 3% Eu doped crystal with an energy resolution of 2.93% FWHM at 662keV. Simulations of SrI2(Eu) crystals were also performed to better understand the light transport physics in scintillators and are reported. This study has important implications for the development

Sturm, Benjamin↗

Conjugate Heat Transfer Analysis of the Supercritical CO2 Based Counter Flow Compact 3D Heat Exchangers

Compact heat exchangers using supercritical fluids such as CO2 are preferred due to their high heat transfer capacity and smaller footprint. Three-dimensional conjugate forced convection heat transfer analysis was performed on several shell-and-tube counter-flow microchannel heat exchangers. Numerical simulations were conducted to test effect of change in mass flow rate, hydraulic diameter and various cross sections on the heat transfer. Increasing mass flow rate improved heat transfer up to a maximum value and then decreased downstream with increasing turbulence. Maximum heat transfer was obtained for the micro channel with the smallest hydraulic diameter. Amongst the cross sections analyzed (circular, square, circular with radial ribs, and square with radial ribs), the most uniform distribution of temperature and maximum heat transfer were obtained for circular cross section with radial ribs. An optimally efficient operation of such a heat exchanger can be attained by considering these factors during multi-objective constrained optimization of geometric parameters and requirements for additive manufacturing of such compact heat exchangers.

Chitale, Janhavi↗

Emulation and Adversarial Analysis of EV Charging Networks

In the effort of decarbonization and evolution of the modern electrical grid, electric vehicles (EVs) play a key part to transform the grid. However, due to the rapid adoption of EVs and the demand of the charging infrastructure required to power said EVs, risk of a cyber-attack may impose serious consequences. There is a need to analyze and protect the charging ecosystem infrastructure from cyber threats before it reaches wide-scale deployment. In an effort to secure vehicle to grid (V2G) communications, standardization is necessary for continued reliable system operation. The protocol ISO 15118 outlines controls and practices that should be implemented for secure vehicle to grid (V2G) communications. The standard is gaining momentum for American markets as the demand for EV infrastructure grows. The adoption of ISO 15118 in American markets poses several challenges: the deployment of a public key infrastructure (PKI) as outlined within the standard, interoperability of charging different EVs with chargers from different manufactures using the PKI, and scaling the ecosystem to meet the demand while managing risks. This project was created to understand potential cyber and scaling challenges of PKI for EV infrastructure through utilizing a series of emulated components mapping to what exists in the EV ecosystem today, and the components of the PKI that are under development. The key nodes within the emulation that are under development are: electric vehicle (EV), electric vehicle supply equipment (EVSE), charge network operator (CNO), certificate authority (CA), and online certificate status protocol (OCSP) that must all interact using secure and trusted communications. With these emulated components and utilizing orchestration methods to rapidly deploy and scale the components, the ability to analyze risks of the ecosystem and address gaps before the PKI ecosystem is fully deployed to production should yield a more robust and mature production charging infrastructure. Our approach will use a modular architecture of virtual machines within an orchestration platform and will target scales of 100s, 1000s, and 10,000s of entities interacting. The core research questions trying to be answered with this scope of work are: what are the impacts of a rogue CA, what are the risks of certificate revocation list (CRL) management, what is the value of OCSP stapling, what components are vulnerable to DOS attacks, and what test effective payloads may impact the components.

charging ecosystem↗

Deuteron Spin Structure function $g_1$ at low $Q^2$

The spin structure function $g_1(x,Q^2)$ and its moments provide crucial information on the internal structure of the nucleon. At low momentum transfer $Q^2$, one can study the transition from partonic (quark-gluon) to hadronic (nucleonic) degrees of freedom and test effective theories based on QCD, for instance Chiral Perturbation Theory (ChPT). As $Q^2$ goes to zero, the first moment of $g_1$ is constrained by the GDH sum rule and its ChPT extensions, which makes measurements of $g_1$ in this region uniquely interesting. As part of the large program of spin structure function measurements with CLAS at Jefferson Lab, the EG4 experiment measured the cross section difference between electron beam and proton/deuteron target spins parallel and antiparallel to each other (and the beam direction) down to small scattering angles (approx. 7 degrees). From these differences, $g_1$ can be extracted, with minimal model uncertainties, down to $Q^2$ as low as 0.01 GeV$^2$. We will give a brief overview of the experiment and its analysis, and present first preliminary results on the deuteron spin structure function $g_{1d}(x,Q^2)$.

Adhikari, Krishna↗

Preliminary LOCA analysis of the westinghouse small modular reactor using the WCOBRA/TRAC-TF2 thermal-hydraulics code

The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (> 225 MWe) integral pressurized water reactor (iPWR) with all primary components, including the steam generator and the pressurizer located inside the reactor vessel. The reactor core is based on a partial-height 17x17 fuel assembly design used in the AP1000{sup R} reactor core. The Westinghouse SMR utilizes passive safety systems and proven components from the AP1000 plant design with a compact containment that houses the integral reactor vessel and the passive safety systems. A preliminary loss of coolant accident (LOCA) analysis of the Westinghouse SMR has been performed using the WCOBRA/TRAC-TF2 code, simulating a transient caused by a double ended guillotine (DEG) break in the direct vessel injection (DVI) line. WCOBRA/TRAC-TF2 is a new generation Westinghouse LOCA thermal-hydraulics code evolving from the US NRC licensed WCOBRA/TRAC code. It is designed to simulate PWR LOCA events from the smallest break size to the largest break size (DEG cold leg). A significant number of fluid dynamics models and heat transfer models were developed or improved in WCOBRA/TRAC-TF2. A large number of separate effects and integral effects tests were performed for a rigorous code assessment and validation. WCOBRA/TRAC-TF2 was introduced into the Westinghouse SMR design phase to assist a quick and robust passive cooling system design and to identify thermal-hydraulic phenomena for the development of the SMR Phenomena Identification Ranking Table (PIRT). The LOCA analysis of the Westinghouse SMR demonstrates that the DEG DVI break LOCA is mitigated by the injection and venting from the Westinghouse SMR passive safety systems without core heat up, achieving long term core cooling. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quantitative Phenomena Identification and Ranking Table (QPIRT) for Bayesian uncertainty quantification

Propagating parameter uncertainty for a nuclear reactor system code is a challenging problem due to often non-linear system response to the numerous parameters involved and lengthy computational times; issues that compound when a statistical sampling procedure is adopted, since the code must be run many times. The number of parameters sampled must therefore be limited to as few as possible that still accurately characterize the uncertainty in the system response. A Quantitative Phenomena Identification and Ranking Table (QPIRT) was developed to accomplish this goal. The QPIRT consists of two steps: a 'Top-Down' step focusing on identifying the dominant physical phenomena controlling the system response, and a 'Bottom-Up' step which focuses on determining the correlations from those key physical phenomena that significantly contribute to the response uncertainty. The Top-Down step evaluates phenomena using the governing equations of the system code at nominal parameter values, providing a 'fast' screening step. The Bottom-Up step then analyzes the correlations and models for the phenomena identified from the Top-Down step to find which parameters to sample. The QPIRT, through the Top-Down and Bottom-Up steps thus provides a systematic approach to determining the limited set of physically relevant parameters that influence the uncertainty of the system response. This strategy was demonstrated through an application to the RELAP5-based analysis of a PWR Total Loss of main Feedwater Flow (TLOFW) accident, also known as feed and bleed' scenario, . Ultimately, this work is the first component in a larger task of building a calibrated uncertainty propagation framework. The QPIRT is an essential piece because the uncertainty of those selected parameters will be calibrated to data from both Separate and Integral Effect Tests (SETs and IETs). Therefore the system response uncertainty will incorporate the knowledge gained from the database of past large IETs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental study on the operational and the cooling performance of the APR+ passive auxiliary feedwater system

The passive auxiliary feedwater system (PAFS) is one of the advanced safety features adopted in the APR+ which is intended to completely replace the conventional active auxiliary feedwater system. The PAFS cools down the steam generator secondary side and eventually removes the decay heat from the reactor core by introducing a natural driving force mechanism; i.e., condensing steam in nearly-horizontal U-tubes submerged inside the passive condensation cooling tank (PCCT). With an aim of validating the cooling and operational performance of the PAFS, the separate effect test, PASCAL (PAFS Condensing Heat Removal Assessment Loop), is being performed to experimentally investigate the condensation heat transfer and natural convection phenomena in the PAFS. A single nearly-horizontal U-tube whose dimension is same as the prototypic U-tube of the APR+ PAFS is simulated in the PASCAL test. By performing the PASCAL test, the major thermal-hydraulic parameters such as local/overall heat transfer coefficients, fluid temperature inside the tube, wall temperature of the tube, and pool temperature distribution in the PCCT were produced not only to evaluate the current condensation heat transfer model but also to present database for the safety analysis related with the PAFS. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Condensation model for the ESBWR passive condensers

In the General Electric's Economic simplified boiling water reactor (GE-ESBWR) the passive containment cooling system (PCCS) plays a major role in containment pressure control in case of an loss of coolant accident. The PCCS condenser must be able to remove sufficient energy from the reactor containment to prevent containment from exceeding its design pressure following a design basis accident. There are three PCCS condensation modes depending on the containment pressurization due to coolant discharge; complete condensation, cyclic venting and flow through mode. The present work reviews the models and presents model predictive capability along with comparison with existing data from separate effects test. The condensation models in thermal hydraulics code RELAP5 are also assessed to examine its application to various flow modes of condensation. The default model in the code predicts complete condensation well, and basically is Nusselt solution. The UCB model predicts through flow well. None of condensation model in RELAP5 predict complete condensation, cyclic venting, and through flow condensation consistently. New condensation correlations are given that accurately predict all three modes of PCCS condensation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

OECD RIA Benchmark Phase II - Towards a better understanding of the RIA fuel modelling

This paper deals with the second phase of the RIA (reactivity initiated accident) fuel rod code benchmark for water-cooled reactors that began in 2014. This second phase has been organized around 2 complementary activities: the first activity is to compare the results of different simulations on simplified cases in order to provide additional bases for understanding the differences in modelling of the concerned phenomena, while the second activity is focused on the assessment of the uncertainty of the results. The detailed specification and comparison of the results from the first activity is presented in this paper. Based on the Phase-I and Phase-II conclusions, some generic recommendations can be made. First, fuel and clad thermomechanical models (with the associated material properties) should be further improved and validated more extensively against a sound RIA database. Secondly, build-up of a comprehensive and robust database consisting of both separate-effect tests and integral tests should be pursued in the short term to reinforce the basis for assessment of both individual model and model integration into codes. Thirdly, an assessment of the uncertainty of fuel thermo-mechanics is of high interest (which is consistent with the second activity of this RIA benchmark Phase-II). Finally, as RIA fuel codes are more and more likely to be used for reactor accident studies, particularly for those involving safety analyses, the fuel rod failure criteria (generally used in such analyses) will have to be carefully justified and validated. The current RIA fuel failure criteria are mainly based on the fuel thermal variables and the verification is based on 'conservative' assumptions for the heat transfer conditions. As all codes give rather consistent evaluations of such variables, it appears possible, taking into account adequate provisions, to derive criteria based on thermal variables from experimental values or from an analytical approach. However, if in the future more mechanistic modelling is ever to be used to establish fuel-failure criteria based on mechanical variables, weaknesses in the validation of the codes identified above will have to be accounted for.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TRACE Code Validation of BWR SVEA Fuel Assembly Spray Cooling

Emergency spray cooling injection is a safety feature implemented in many boiling water reactor designs to reflood a reactor during an accident. Significant experimental work has qualified the efficacy of spray cooling, and ongoing computational modeling efforts strive to more accurately portray the phenomena involved. This work examines the physical phenomena pertaining to emergency spray cooling injection over SVEA-type fuel assemblies. BWR emergency core cooling system (ECCS) designs commonly incorporate a Low-Pressure Core Spray (LPCS) system that introduces coolant through spray nozzles directed to the top of the core, and are located in the upper plenum region. This design is effective for LOCA response, particularly during the initial refill and reflood stages of accident response where the goal is limiting the peak cladding temperature rise in the core. The U.S. NRC thermal-hydraulics code TRACE version 5.0 Patch 4 has been chosen to simulate the separate-effect tests performed by ASEA-ATOM. The computational model was evaluated by performing forward uncertainty quantification using Dakota as the analysis tool and code driver on 31 identified parameters from the input model and TRACE physical constitutive models. This paper discusses the sensitivity of the investigated parameters with respect to spray cooling simulation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Convective Heat Transfer in Decay Heat Exchanger of Sodium-cooled Fast Reactor

Sodium-to-sodium heat exchangers such as the decay heat exchanger (DHX) are key components of the prototype generation [V sodium-cooled fast reactor (PGSFR). The DHX transfers the decay heat generated in the reactor core to the decay heat removal loop after a reactor shutdown. Shell-and-tube type with straight tube arrangement has been widely adopted for the sodium-to-sodium heat exchanger of the sodium-cooled fast reactor. Thus liquid metal heat transfer characteristics inside the tube and around the tube bundle have to be fully understood to design the sodium-to-sodium heat exchanger and evaluate its thermal performance accurately. Plenty of studies on the convective heat transfer of the liquid metals were conducted to present the Nusselt number (Nu) correlations with respect to the Peclet number (Pe). However, those correlations still deviated from each other considerably and few of correlations for low Pe range (less than 100) have been reported. Accordingly, it is difficult for a design code developer to choose a proper heat transfer coefficient correlation for the sodium-to-sodium heat exchanger particularly in a low flow rate range. Recently, a separate effect test for the DHX has been completed using the STELLA-1 facility at KAERI according to the STELLA program which aims at establishment of separate and integral test database (DB) for the design of the PGSFR. The heat transfer performance test of the DHX was successfully conducted under major operating conditions. The objective of this work is to suggest proper convective heat transfer correlations for tube- and shell-sides of the sodium-to-sodium heat exchanger based on the test DB obtained from STELLA-1. The Pe range of the analyzed experimental data is concentrated on less then 100. The adequacy of the suggested correlations is evaluated by applying to the DHX design code, SHXSA. Based on the DHX test DB of the STELLA-1, the proper convective heat transfer correlations for the tube- and shell-side of sodium-to-sodium heat exchangers were suggested. Two correlation combinations for each side were proposed and turned out to be reasonable through the evaluation using the SHXSA design code: Suggestion no. 1: - Lyon correlation (constant = 4) for tube-side; - Lubarsky-Kaufman correlation for shell-side. Suggestion no. 2: - Modified Lyon correlation (constant = 1.45) for tube-side; - Schad-modified correlation for shell-side The Pe ranges of the DHX test DB were 53 - 225 for the tube-side and 45 - 148 for the shell-side, but most of test conditions were concentrated on the Pe range of less than 100. Two correlation suggestions can be practically used for the design of sodium-to-sodium heat exchangers. However, by utilizing more test DB, it needs to be verified which one is closer to real phenomena. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗