At least 703 records · Page 39

Effects of knock intensity measurement technique and fuel chemical composition on the research octane number (RON) of FACE gasolines: Part 1 – Lambda and knock characterization

The Research and Motor Octane Number (RON and MON) rate the knock propensity of gasoline in the Cooperative Fuel Research (CFR) engine by comparing the knock intensity of sample fuels relative to that of primary reference fuels (PRF), a binary blend of iso-octane and n-heptane. Important differences exist between standard octane testing and automotive spark ignition (SI) engine knock testing including speed, load, air-to-fuel equivalence ratio (lambda), and knock characterization, which lead to a discrepancy between a fuel’s RON rating and its knock resistance characterized on an automotive SI engine based on knock-limited spark advance. This publication is the first of a set of three publications which modify operating parameters of the RON test method (ASTM D2699) to investigate the effects of these differences with automotive SI engine knock-limited spark advance testing. A fuel’s standard RON is evaluated at the lambda of the highest knock intensity, whereas automotive SI engines typically operate at stoichiometry. Here, we analyze the effects of a stoichiometric RON rating methodology. Additionally, the knock intensity response from the standard CFR knockmeter system is compared to a cylinder pressure oscillation-based knock intensity at several lambda settings. All experiments were performed with a set of seven Coordinating Research Council (CRC) Fuels for Advanced Combustion Engines (FACE) gasolines with approximately 95 RON. The fuel chemical composition impacted the lambda of the highest knock intensity, which resulted in fuel-specific offsets between the standard and stoichiometric RON ratings. The knock system comparison showed significant offsets between cylinder pressure-based and knockmeter-based knock intensity levels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of knock intensity measurement technique and fuel chemical composition on the research octane number (RON) of FACE gasolines: Part 2 – Effects of spark timing

The Research and Motor Octane Number (RON, MON) characterize a fuel’s knock resistance by rating the knock intensity of a sample fuel relative to that of Primary Reference Fuels (PRF) in a Cooperative Fuel Research (CFR) Engine. A fuel’s octane number is regulated to prevent damage from autoignition leading to knocking combustion in spark-ignition engines. The operational differences between the standard RON rating and modern engine operation are explored in a three-part publication series. The previous study focused on the effects of lambda and knock characterization. This second study primarily focuses on the effects of spark timing on RON determination. Following the findings from the first publication, the knock intensity was captured by the knockmeter and by the maximum amplitude of pressure oscillations (MAPO) at the lambda of peak knock intensity and stoichiometry. Knock-limited spark advance tests were conducted for a set of seven Fuels for Advanced Combustion Engines (FACE) from the Coordinating Research Council (CRC) with varying chemical composition, PRFs, and Toluene Standardization Fuels (TSFs). For retarded spark timings, pre-spark low-temperature heat release was found for low RON PRFs. Low RON PRFs also showed knocking characteristics before reaching the center of combustion suggesting that the use of knock-limited spark advance (KLSA) was preferred over the knock-limited combustion phasing. Primarily paraffinic fuels tended towards increased pressure oscillations while dominantly aromatic fuels experienced higher pressure rise rates. A MAPO-based KLSA correlated best to Octane Index at a negative K-factor suggesting beyond RON operation despite being at otherwise RON conditions. At stoichiometry, the MAPO-based KLSA did neither correlate to RON nor Octane Index. Finally, good agreement was found between KLSA-based effective RON from this study to the MAPO-based effective RON from the first study.

10 SYNTHETIC FUELS↗

Technique for an improved and time-resolved carbon areal density measurement with a single channel diagnostic for inertial confinement fusion

Measurement of the areal density and velocity of the carbon ablator shell during peak burn in inertial confinement fusion give powerful information on the state of the ablator and where in the trajectory of implosion it reaches peak burn. Detailed comparison of the absolute densities and velocities of the carbon in implosions has been prevented by the limited ability to resolve shot-to-shot variation within a shot series or within a campaign. Here, a new approach using a single, ultra fast (~10 ps) gamma ray channel can massively reduce uncertainties and will provide insights on improvements to target and drive variables. Small improvements in these experimental design parameters may result in much greater yields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ quantification of fracture slip induced by hydraulic injections in a deep borehole: A comparison of two different borehole techniques

In situ measurements of fracture deformation during fluid injection are rare, yet essential for understanding the mechanical response of fractured rock. In this study, we evaluate the reliability of two methods by comparing their slip vector estimates: high-resolution borehole acoustic televiewer images captured before and after injection tests, and displacement data from a three-component borehole deformation probe recorded during the injections. Acoustic televiewer images capture only final in-plane displacement, whereas three-component borehole deformation measurements provide full 3D, transient fracture movement. Four injection tests in a fractured granitic rock mass along an inclined borehole at the Bedretto Underground Laboratory (Switzerland), beneath more than 1100 m of overburden, were analyzed. The two methods yielded consistent kinematics and comparable slip magnitudes, typically in the range of 0.2 – 0.6 mm. Angular differences between estimated slip directions ranged from 0.2° to 28°. For two test intervals with pre-existing fractures optimally oriented for slip, the measured slip vectors agreed with forward-modeled slip vectors based on the regional in situ stress field, supporting the Wallace–Bott hypothesis. Measurable shear displacement was identified in two test intervals containing fractures oriented nearly perpendicular to the least principal stress, including a newly formed hydraulic fracture. This demonstrates that even fractures unfavorably oriented for slip can undergo shear due to local stress perturbations around an inclined borehole.

Acoustic televiewer↗

Evaluation of a 3-Dimensional-Printed Head Simulation Technique for Teaching Flexible Nasopharyngoscopy to Radiation Oncology Residents

Simulation-based medical education is an effective tool for medical teaching, but simulation-based medical education deployment in radiation oncology (RO) is limited. Flexible nasopharyngoscopy (FNP), an essential skill for RO residents, requires practice that typically occurs on volunteer patients, introducing the potential for stress and discomfort. We sought to develop a high-fidelity simulator and intervention that provides RO residents the opportunity to develop FNP skills in a low-pressure environment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Health-Related Quality of Life Outcomes in Head and Neck Cancer: Results From a Prospective, Real-World Data Study With Brazilian Patients Treated With Intensity Modulated Radiation Therapy, Conformal and Conventional Radiation Techniques

To compare global health-related quality of life (HRQoL) and overall survival (OS) in patients with head and neck cancer treated with intensity modulated radiation therapy (IMRT), conformal radiation therapy (3DCRT) or conventional radiation therapy (2DRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗