Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “systems testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Calculating the free energy of transfer of small solutes into a model lipid membrane: Comparison between metadynamics and umbrella sampling

We compare the performance of two well-established computational algorithms for the calculation of free-energy landscapes of biomolecular systems, umbrella sampling and metadynamics. We look at benchmark systems composed of polyethylene and polypropylene oligomers interacting with lipid (phosphatidylcholine) membranes, aiming at the calculation of the oligomer water-membrane free energy of transfer. We model our test systems at two different levels of description, united-atom and coarse-grained. We provide optimized parameters for the two methods at both resolutions. We devote special attention to the analysis of statistical errors in the two different methods and propose a general procedure for the error estimation in metadynamics simulations. Metadynamics and umbrella sampling yield the same estimates for the water-membrane free energy profile, but metadynamics can be more efficient, providing lower statistical uncertainties within the same simulation time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

3D printed structures for optimized carbon capture technology in packed bed columns

The use of 3D printed structured packing for the optimization of aqueous-amine based carbon capture in packed absorption columns is examined in this paper. An experimental testing system has been set up, and initial comparisons were made between metal, plastic, and 3D printed 16-inch packing elements and between three 8-inch 3D printed elements of different densities. Pressure drop measurements were obtained at various air flowrates under dry conditions. Measurements were also taken for a wet system by adding water at six different liquid flowrates. In each case, theoretical calculations for pressure drop were performed based on a model presented in the literature. It was found that, for the 16-inch dry column, the model slightly overpredicts the pressure drop. The model provides an accurate prediction for the dry 8-inch experimental data, especially for the two least dense packing elements. For the wet system, the model overpredicts the pressure drop, likely due to modeling deficiencies when the column reaches its loading limit. Furthermore, these results provide sufficient confidence to move forward with testing and process intensification of the CO 2 capture process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In situ environmentally-isolated wear tester

The present invention relates to an in situ testing system, which includes a wear tester and an enclosure. The wear tester is configured to apply a normal load, by way of a tip, to a surface of the test sample. Use of an enclosure allows such wear testing to be conducted in a controlled environment.

36 MATERIALS SCIENCE↗

Next Generation Durable, Cost Effective, Energy Efficient Tubular SOFC (Final Scientific/Technical Report)

The overall objective of this project is to develop and optimize a YSZ electrolyte-based solid oxide fuel cell (SOFC) technology for low cost, low temperature (~ 650°C), and high energy efficiency operation. The developed technology will be implemented and demonstrated in a high efficiency 2~3kW SOFC with applicability to sub-MW systems. A summary of significant accomplishments is provided below. Key accomplishments: 1. Improved fundamental cell technology demonstrated at single tube and system scale. Improved power output by 54% while operating at the normal temperature of 750°C. And improved power output by 33% while operating at 650°C, 100°C lower than normal temperature. 2. SPS patented internal recycle arrangement was developed and extended to operate on LPG fuel directly in a compact, high-efficiency (> 40%) system. 3. System testing was conducted to prove the long-term durability of cell improvements. Demonstrated over 8000 hours of operation at 0.21 %/1000 hrs degradation. 4. A large-scale, 2.5kW net power system demonstration was completed, which demonstrated 40% net efficiency over 1000 hours. 5. System design and cost analysis of a 1MW system utilizing a 2.5kW bundle was completed. Cost optimization of the bundle showed a reduction of nearly 80% is possible from $\$$5,790/kW to $\$$1250/kW. This lower cost is considered viable for SPS commercialization.

03 NATURAL GAS↗

Operational resilience metrics for power systems with penetration of renewable resources

Abstract Modern power grid is evolving towards carbon neutrality by deploying increasing amount of renewable energy resources. However, the impact of renewable generation on power system planning and operation is not sufficiently investigated, especially the capability of renewable penetrated power systems to resist and recover from major disturbances, which is a critical concern for system operators. Novel metrics and evaluation methodologies are needed to depict systems’ ability in response to events caused by natural disasters, and quantitatively evaluate system performance in various time scales. In this paper, operational resilience metrics are proposed for power systems with penetration of renewable energy resources based on transient stability principles. A systematic methodology is proposed to quantitatively assess the evolution of system performance during various stages of the disaster process. Based on the proposed metrics, a resilience‐oriented disaster management strategy is designed and validated using the modified IEEE 39‐bus test system. The simulation results demonstrate the validity of the proposed metrics and strategy, and show that the system resilience is enhanced during the mitigation of fault conditions.

Gui, Jianzhong↗

Investigation of storage options for scientific computing on Grid and Cloud facilities

In recent years, several new storage technologies, such as Lustre, Hadoop, OrangeFS, and BlueArc, have emerged. While several groups have run benchmarks to characterize them under a variety of configurations, more work is needed to evaluate these technologies for the use cases of scientific computing on Grid clusters and Cloud facilities. This paper discusses our evaluation of the technologies as deployed on a test bed at FermiCloud, one of the Fermilab infrastructure-as-a-service Cloud facilities. The test bed consists of 4 server-class nodes with 40 TB of disk space and up to 50 virtual machine clients, some running on the storage server nodes themselves. With this configuration, the evaluation compares the performance of some of these technologies when deployed on virtual machines and on bare metal nodes. In addition to running standard benchmarks such as IOZone to check the sanity of our installation, we have run I/O intensive tests using physics-analysis applications. This paper presents how the storage solutions perform in a variety of realistic use cases of scientific computing. One interesting difference among the storage systems tested is found in a decrease in total read throughput with increasing number of client processes, which occurs in some implementations but not others.

Garzoglio, Gabriele↗

Developing VSC-HVDC Oscillation Damping Control Constraints in Unit Commitment

High-voltage direct current (HVDC) systems within the existing power grids will play a pivotal role in enabling high share of renewable power integration and transportation electrification. There is a need for transmission planning models to accurately capture the impact of VSC-HVDC oscillation damping control on the system planning and model the constraints in the security constrained unit commitment (SCUC) problem. In this paper, the SCUC problem in a hybrid DC-AC grid considering damping on electromechanical inter-area oscillation is studied. An electromechanical oscillation-driven transmission capability constraints are derived from system swing equation and incorporated into the SCUC. Multiple system damping control scenarios are set based on the extracted plausible bounds of damping coefficient and inertia constant to linearize the nonlinear expressions. The SCUC problem with proposed constraints is tested on the Reliability Test System Grid Modernization Lab Consortium (RTS-GMLC) via PLEXOS. The impact of the proposed constraints on regional generation, inertia, power flow, annual system cost, and renewable energy curtailment are fully assessed.

damping control↗

Formulation of Three-Phase State Estimation Problem Using a Virtual Reference

State Estimation (SE) is the backbone of modern Energy Management System (EMS) due its capability of processing real time measurements and provide reliable information to system operators. Since its introduction to power systems in the 70’s, SE has been widely used in transmission networks. Distribution grids on the other hand lack sufficient number of real time measurements, and for that reason SE has not been widely implemented on these systems. The recent increase in the number of renewable energy sources connected to the grid at lower voltage levels, the advent of Distribution Automation (DA) and Smart Grids necessitate closer monitoring of distribution networks and thus forcing utilities to upgrade their operations and deploy Advanced Distribution Management Sytems (ADMS). Therefore, Distribution System State Estimation (DSE) is paramount to provide real time monitoring of active distribution grids. This papers investigates the formulation of the three-phase distribution state estimation where in the most general case, none of the system buses may have balanced three phase voltages. In such a case, the choice and definition of the slack bus need to be revisited. Most of the existing work arbitrarily assign the root bus of the distribution feeder as the balanced three-phase reference which may not be realistic for today’s active distribution systems. This paper addresses this shortcoming of the existing SE formulations by introducing a virtual reference bus. Here, the proposed approach is effectively validated by simulations carried out on distribution test systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Final Report: Part 1. In-Place Filter Testing Instrument for Nuclear Material Containers. Part 2. Canister Filter Test Standards for Aerosol Capture Rates.

A portable instrument has been developed to assess the functionality of filter sand o-rings on nuclear material storage canisters, without requiring removal of the canister lid. Additionally, a set of fifteen filter standards were procured for verifying aerosol leakage and pressure drop measurements in the Los Alamos Filter Test System. The US Department of Energy uses several thousand canisters for storing nuclear material in different chemical and physical forms. Specialized filters are installed into canister lids to allow gases to escape, and to maintain an internal ambient pressure while containing radioactive contaminants. Diagnosing the condition of container filters and canister integrity is important to ensure worker and public safety and for determining the handling requirements of legacy apparatus. This report describes the In-Place-Filter-Tester, the Instrument Development Plan and the Instrument Operating Method that were developed at the Los Alamos National Laboratory to determine the “as found” condition of unopened storage canisters. The Instrument Operating Method provides instructions for future evaluations of as-found canisters packaged with nuclear material. Customized stainless steel canister interfaces were developed for pressure-port access and to apply a suction clamping force for the interface. These are compatible with selected Hagan-style and SAVY-4000 storage canisters that were purchased from NFT (Nuclear Filter Technology, Golden, CO). Two instruments were developed for this effort: an initial Los Alamos POC (Proof-of-Concept) unit and the final Los Alamos IPFT system. The Los Alamos POC was used to create the Instrument Development Plan: (1) to determine the air flow and pressure characteristics associated with canister filter clogging, and (2) to test simulated configurations that mimicked canister leakage paths. The canister leakage scenarios included quantifying: (A) air leakage due to foreign material (i.e. dust and hair) fouling of o-rings, (B) leakage through simulated cracks in o-rings, and (C) air leakage due to inadequately tightened canister lids. The Los Alamos POC instrument determined pertinent air flow and pressure quantities, and this knowledge was used to specify a customized Isaac® (Z axis, Salt Lake City, UT) leak test module. The final Los Alamos IPFT (incorporating the Isaac® leak test module) was used to repeat the tests in the Instrument Development Plan (with simulated filter clogging tests and canister leak pathway tests). The Los Alamos IPFT instrument is capable of determining filter clogging and leak rate conditions, without requiring removal of the container lid. The IPFT measures pressure decay rate from 1.7E-03 in WC/sec to 1.7E-01 in WC/sec. On the same unit scale, helium leak testing of canisters has a range from 5.7E-07 in WC/sec to 1.9E-03 in WC/sec. For a 5-quart storage canister, the IPFT measures equivalent leak flow rates from 0.03 to 3.0 cc/sec. The IPFT does not provide the same sensitivity as helium leak testing, but is able to gauge the assembled condition of as-found and in-situ canisters.

61 RADIATION PROTECTION AND DOSIMETRY↗

Update on Small Modular Reactors Dynamic System Modeling Tool: Web Application

Previous reports focused on the development of component and system models as well as end-to-end system models using Modelica and Dymola for two advanced reactor architectures: (1) Advanced Liquid Metal Reactor and (2) fluoride high-temperature reactor (FHR). The focus of this report is the release of the first beta version of the web-based application for model use and collaboration, as well as an update on the FHR model. The web-based application allows novice users to configure end-to-end system models from preconfigured choices to investigate the instrumentation and controls implications of these designs and allows for the collaborative development of individual component models that can be benchmarked against test systems for potential inclusion in the model library. A description of this application is provided along with examples of its use and a listing and discussion of all the models that currently exist in the library.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Developing VSC-HVDC Oscillation Damping Control Constraints in Unit Commitment

High-voltage direct current (HVDC) systems within the existing power grids will play a pivotal role in enabling high share of renewable power integration and transportation electrification. There is a need for transmission planning models to accurately capture the impact of VSC-HVDC oscillation damping control on the system planning and model the constraints in the security constrained unit commitment (SCUC) problem. In this paper, the SCUC problem in a hybrid DC-AC grid considering damping on electromechanical inter-area oscillation is studied. An electromechanical oscillation-driven transmission capability constraints are derived from system swing equation and incorporated into the SCUC. Multiple system damping control scenarios are set based on the extracted plausible bounds of damping coefficient and inertia constant to linearize the nonlinear expressions. The SCUC problem with proposed constraints is tested on the IEEE 73-bus reliability test system (RTS) case via PLEXOS. The impact of the proposed constraints on regional generation, inertia, power flow, annual system cost, and renewable energy curtailment are fully assessed.

damping control↗

How to reduce Shutdown Dose Rates in ITER Diagnostics Equatorial Ports

The ITER vacuum vessel presents 54 access ports, arranged in three levels, where port plugs are inserted hosting different types of systems: test blanket modules, antennas, vacuum pumps, neutral beam injectors and diagnostics. At the equatorial level, nine out of the eighteen access ports present diagnostics port plugs, in which the diagnostics systems are deployed into three DSMs (Diagnostics Shield Modules). The DSMs, being a major constituent in volume of the port plugs, must help to fulfill the design target of Shutdown Dose Rates (SDDR) corresponding to 100 μSv.h{sup -1} after 10{sup 6} s of cooling time for planned in-situ maintenance operations in the port interspace. Additionally, the DSMs are largely responsible for the port plug drained weight limit of 45 T, which imposes limitations to the shielding technology. Up to now, all the proposed DSM designs combine differently stainless steel, water and/or B{sub 4}C as shielding to accommodate a maximum of 1.1 m{sup 3} of DSM bulk shield, contained into a L 1845 x W 518 x H 2011 mm stainless steel box weighting 5.8 T for each DSM. These proposals show insufficient shielding properties with respect to SDDR, while none of them satisfies currently the weight limit. However, during 2016, a new DSM concept has been developed, named 'modular DSM', with significant engineering advances and changes. The DSM length has been increased by 500 mm, up to 2345 mm. The SS box has been reduced to the minimum structure required, presenting the same weight while being larger and hosting a larger volume of bulk shielding inside. Thus, the volume of bulk shielding has been enlarged up to 1.5 m{sup 3} per DSM. The shielding technology is based on B{sub 4}C bricks deployed in SS trays that are attached to the vertical plates. This results in a bulk shielding made of 65% of B{sub 4}C, 10% SS and 25% void, with effective density of 2.4 g.cm{sup -3}. In summary, the modular DSM, without a weight increase, hosts extra 0.5 m3 of bulk shielding along an additional 500 mm of length, to be used with a light but highly neutron absorber, what allows fitting the weight limit of 45 T for the port plug once drained. From now, the non-modular DSMs will be referred as 'short DSMs'. The modular DSM's advantages with respect to the short DSM versions have shown that the DSMs design can be improved in generic approach, i.e. when the penetrations of the systems are not taken into consideration. A mention apart is required when port specific penetrations are considered. Provided that they will be an important radiation transmission path, their presence could significantly diminish the improvement. To clarify this issue, in this work we have carried out a nuclear analysis of the ITER equatorial port no. 11 integration considering the modular DSM. It is a first plasma port hosting the following 6 major diagnostics systems: Neutral Particle Analyzer (NPA), H-α monitor, Low Field Side (LFS) reflectometry, Visible - Ultraviolet divertor (VUV div), Visible - Ultraviolet core survey (VUV CS) and X-rays Crystal System (XRCS). For the baseline case, a SDDR matrix has been derived assigning responsibilities to the different EP no. 11 individual systems in terms of neutron flux transmission through them, and the related activation due to that neutron flux (activation of itself, but also of the rest of systems taken one by one). Different EP no. 11 configurations have been studied in addition to the baseline case. For example, the backfill of the port plug penetrations to protect all the empty space not required for systems sight. Another issue is the determination of the role of the Co impurity content minimization from 0.05 wt.% to 0.03 wt.% recently proposed. In this summary, only some results related to the baseline are given.

61 RADIATION PROTECTION AND DOSIMETRY↗

ISDSN Sensor System Phase One Test Report

This Phase 1 Test Report documents the test activities and results completed for the Idaho National Laboratory (INL) sensor systems that will be deployed in the meso-scale test bed (MSTB) at Florida International University (FIU), as outlined in the ISDSN-MSTB Test Plan. This report captures the sensor system configuration tested; test parameters, testing procedure, any noted changes from the implementation plan, acquired test data sets, and processed results.

58 GEOSCIENCES↗

Hydrogen storage properties of magnesium nanotrees investigated by a quartz crystal microbalance system

We report on enhanced low temperature hydrogen storage properties of magnesium “nanotrees” fabricated by glancing angle deposition (GLAD) method. The arrays of nanotrees and conventional thin films of elemental Mg have been deposited directly onto gold coated unpolished quartz crystal substrates. Mg nanotrees were about 15 μm in height, 10 μm by 1 μm in lateral size, and were composed of “nanoleaves” of about 20 nm in thickness, 2 μm length, and 1 μm width. Hydrogen absorption and desorption properties of Mg nanotrees and thin films were investigated using a quartz crystal microbalance (QCM) testing system that is capable of measuring weight changes with a nanogram sensitivity. QCM absorption tests were performed at temperatures 100, 200, and 300 °C under 30 bars of H 2 pressure. Measurements revealed that Mg nanotrees can absorb hydrogen at significantly higher weight percentage (wt%) and faster rates compared to conventional Mg films under similar conditions. Hydrogen storage of Mg thin film was observed to be at 0.02, 0.30 and 3.91 wt% (weight percentage), while it reached to 1.26, 3.75, and 5.86 wt% for nanotrees at temperatures 100, 200, and 300 °C, respectively, after 150 min. In addition, the results of desorption experiments show that Mg nanotrees can start to release hydrogen at temperatures as low as 100 °C at a rate of 0.11 wt% (vs. 0.01 wt% for thin film at the same temperature) with desorption rates reaching to 1.05 wt% at 200 °C (0.26 wt% for thin film) and 2.57 wt% at 300 °C (1.45 wt% for thin film), which are considerably lower desorption temperatures compared to previously reported values for bulk Mg (>300 °C). The enhancement in hydrogen absorption and desorption properties of Mg nanotrees is believed to originate from their thin and isolated nanoleaves that also have an improved oxidation resistance property.

08 HYDROGEN↗

A universal density matrix functional from molecular orbital-based machine learning: Transferability across organic molecules

We address the degree to which machine learning (ML) can be used to accurately and transferably predict post-Hartree-Fock correlation energies. Refined strategies for feature design and selection are presented, and the molecular-orbital-based machine learning (MOB-ML) method is applied to several test systems. Strikingly, for the second-order Møller-Plessett perturbation theory, coupled cluster with singles and doubles (CCSD), and CCSD with perturbative triples levels of theory, it is shown that the thermally accessible (350 K) potential energy surface for a single water molecule can be described to within 1 mhartree using a model that is trained from only a single reference calculation at a randomized geometry. To explore the breadth of chemical diversity that can be described, MOB-ML is also applied to a new dataset of thermalized (350 K) geometries of 7211 organic models with up to seven heavy atoms. In comparison with the previously reported Δ-ML method, MOB-ML is shown to reach chemical accuracy with threefold fewer training geometries. Finally, a transferability test in which models trained for seven-heavy-atom systems are used to predict energies for thirteen-heavy-atom systems reveals that MOB-ML reaches chemical accuracy with 36-fold fewer training calculations than Δ-ML (140 vs 5000 training calculations).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Multi-Output Hybrid Energy Systems Interacting with the Grid: Application of Improved Price-Taker and Price-Maker Approaches to Nuclear-Hydrogen Systems

The growing recognition of the value of hydrogen as an energy intermediate in supporting future power systems with high shares of variable renewable energy has prompted many studies to quantify the economic potential of multi-output hybrid systems, which are one type of integrated energy systems (IES). Because of the complexity of modeling multiple sectors, these studies typically use simplified modeling approaches to capture the interactions between sectors. In this study, we explore the implications of alternative modeling approaches for nuclear-hydrogen IES focusing on a power system in the Midwest United States. We combine highly resolved capacity expansion and production cost modeling tools of the power system with a detailed hydrogen system optimization tool to determine the optimal electrolyzer and storage sizing and optimal operations of the nuclear-hydrogen hybrid resource across three future study years. We compare economic and operational outcomes across a spectrum of modeling approaches, including a non-hybridized base approach; a traditional price-taker approach that does not include the impact of hydrogen production on the electricity system; a power-system-focused price-maker approach that does not account for temporal hydrogen constraints; and two improved price-taker and price-maker approaches that each address the impact of revenue-optimal levels of electricity production on the resulting power system and temporal hydrogen constraints on the overall feasible solution. Results show how a traditional price-taker approach can overestimate the economic benefits of multi-output nuclear-hydrogen IES compared to our two improved approaches that estimate both hydrogen system constraints and power system interaction. We find that hydrogen output requirements and storage size limits are key drivers to overall operations and some economic outcomes. Under our assumed constant hydrogen output requirement, storage costs, test system, and modeling approaches, our results indicate that hybridization can provide a net benefit, but results are sensitive to the treatment of hydrogen revenues and electricity prices as impacted by the power system evolution.

capacity expansion modeling↗

Tau leaping of stiff stochastic chemical systems via local central limit approximation

Stiffness manifests in stochastic dynamic systems in a more complex manner than in deterministic systems; it is not only important for a time-stepping method to remain stable but it is also important for the method to capture the asymptotic variances accurately. In the context of stochastic chemical systems, time stepping methods are known as tau leaping. Well known existing tau leaping methods have shortcomings in this regard. The implicit tau method is far more stable than the trapezoidal tau method but underestimates the asymptotic variance. On the other hand, the trapezoidal tau method which estimates the asymptotic variance exactly for linear systems suffers from the fact that the transients of the method do not decay fast enough in the context of very stiff systems. We propose a tau leaping method that possesses the same stability properties as the implicit method while it also captures the asymptotic variance with reasonable accuracy at least for the test system S{sub 1}↔S{sub 2}. The proposed method uses a central limit approximation (CLA) locally over the tau leaping interval and is referred to as the LCLA-τ. The CLA predicts the mean and covariance as solutions of certain differential equations (ODEs) and for efficiency we solve these using a single time step of a suitable low order method. We perform a mean/covariance stability analysis of various possible low order schemes to determine the best scheme. Numerical experiments presented show that LCLA-τ performs favorably for stiff systems and that the LCLA-τ is also able to capture bimodal distributions unlike the CLA itself. The proposed LCLA-τ method uses a split implicit step to compute the mean update. We also prove that any tau leaping method employing a split implicit step converges in the fluid limit to the implicit Euler method as applied to the fluid limit differential equation.

97 MATHEMATICS AND COMPUTING↗