Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

High-Resolution Mapping of SO2 Using Airborne Observations from the GeoTASO Instrument During the KORUS-AQ Field Study: PCA-Based Vertical Column Retrievals

The Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) instrument is an airborne hyperspectral spectrometer measuring backscattered solar radiation in the ultraviolet (290–400 nm) and visible (415–695 nm) wavelength regions. This paper presents high-resolution sulfur dioxide (SO2) maps over the Korean Peninsula, produced by SO2 retrievals from GeoTASO measurements during the Korea–United States Air Quality Field Study (KORUS-AQ) from May to June 2016. The highly sensitive GeoTASO instrument with a spatial resolution of ~250 m × 250 m can detect point emission sources of SO2 within its fields of view, even without merging multiple overlapping observations. To retrieve SO2 vertical columns from the GeoTASO measurements, we apply an algorithm based on principal component analysis (PCA), which is effective in suppressing noise and biases in SO2 retrievals. The retrievals successfully capture SO2 plumes and various point sources such as power plants, a petrochemical complex, and a steel mill, located in South Chungcheong Province, some of which are not detected by a ground-based in situ measurement network. Spatial distributions of SO2 from GeoTASO observations in source areas are consistent with those from the Stack Tele-Monitoring System reports and airborne in situ SO2 measurements. Comparisons of SO2 retrievals from GeoTASO and existing satellite sensors demonstrate the significance of high-resolution SO2 observations, by indicating that GeoTASO detects small SO2 emission sources that are not precisely resolved by single overpasses of satellites. To assess future geostationary SO2 observations having a higher spatial resolution, we upscale the GeoTASO SO2 retrievals to a spatial resolution of the Geostationary Environment Monitoring Spectrometer (GEMS). Since the upscaled GeoTASO retrievals also detect SO2 plumes clearly, we expect from GEMS to identify even small SO2 emission sources over Asia.

Chong, Heesung↗

Observations on the long-period variability of the Gulf Stream downstream of Cape Hatteras

To examine the long-period variability of the Gulf Stream, sea level residuals relative to a 2-year mean sea level in the Gulf Stream downstream of Cape Hatteras (between 75 deg W and 60 deg W longitude) are used. Residuals, as derived from Geosat altimetry between November 1986 and December 1988, were gridded in space and time at a temporal resolution of 10 days and spatial resolution of 1/4 deg. Complex empirical orthogonal function (CEOF) analysis was applied to the data set to extract the spatially correlated signal with the original data subsampled to 1/2 deg. In addition to determining the space-time scales and propagation characterisitics of the different modes, wavenumber-frequency spectral techniques were used to separate the variability into propagating and stationary components. The CEOF technique applied to the data set indicated that the first four CEOF modes accounted for 60% of the variability and were found to be above the noise leve 99% of the time. CEOF 1 was associated with westward propagation at 5 km/d at a wavelength of 2000 km and eastward propagation at 1-2 km/d centered at a 500-km wavelength. This first CEOF is in good agreement with thin-jet equivalent barotropic models which predict westward propagation for wavelengths greater than 1130 km. A deflection of the wavelike pattern at 65 deg W also indicates a possible topographic effect. A simple scaling of the effect of topography indicates that for length scales longer than the internal Rossby radius of deformation, the topographic term is at least of the same order of magnitude as the beta effect. The second CEOF was more broadbanded in wavenumber space, with eastward propagation occurring in a wavenumber-frequency band between 300 and 1400 km and 0.5 and 2.0 cycles/yr. The third CEOF is similar in structure to the first, but with less energy. CEOF 4 was clearly identifiable with higher frequencies than the first three with westward propagation at 4 km/d. The spatial location of this mode along with the westward propagation indicates possible influences from eddy-stream interactions. Thus topography, Rossby wave dynamics and eddy-stream interactions all appear to have a significant role in determining the space-time scales and propagation properties of the long-period response of sea level in the Gulf Stream.

Vazquez, Jorge↗

Concentration Measurements in Self-Excited Momentum Dominated Low-Density Gas Jets

Flow structure of self-excited, laminar, axisymmetric, momentum-dominated helium jets discharged vertically into ambient air was investigated using high-speed rainbow schlieren deflectometry technique. Measurements were obtained at temporal resolution of 1 ms and spatial resolution of 0.19 mm for two test cases with Richardson number of 0.034 and 0.018. Power spectra revealed that the oscillation frequency was independent of spatial coordinates, suggesting global oscillations in the flow. Abel inversion algorithm was used to reconstruct the concentration field of helium. Instantaneous concentration contours revealed changes in the flow field and evolution of vortical structures during an oscillation cycle. Temporal evolution plots of helium concentration at different axial locations provided detailed information about the instability in the flow field.

Yildirim, B. S.↗

Hyperspectral Fluorescence and Reflectance Imaging Instrument

The system is a single hyperspectral imaging instrument that has the unique capability to acquire both fluorescence and reflectance high-spatial-resolution data that is inherently spatially and spectrally registered. Potential uses of this instrument include plant stress monitoring, counterfeit document detection, biomedical imaging, forensic imaging, and general materials identification. Until now, reflectance and fluorescence spectral imaging have been performed by separate instruments. Neither a reflectance spectral image nor a fluorescence spectral image alone yields as much information about a target surface as does a combination of the two modalities. Before this system was developed, to benefit from this combination, analysts needed to perform time-consuming post-processing efforts to co-register the reflective and fluorescence information. With this instrument, the inherent spatial and spectral registration of the reflectance and fluorescence images minimizes the need for this post-processing step. The main challenge for this technology is to detect the fluorescence signal in the presence of a much stronger reflectance signal. To meet this challenge, the instrument modulates artificial light sources from ultraviolet through the visible to the near-infrared part of the spectrum; in this way, both the reflective and fluorescence signals can be measured through differencing processes to optimize fluorescence and reflectance spectra as needed. The main functional components of the instrument are a hyperspectral imager, an illumination system, and an image-plane scanner. The hyperspectral imager is a one-dimensional (line) imaging spectrometer that includes a spectrally dispersive element and a two-dimensional focal plane detector array. The spectral range of the current imaging spectrometer is between 400 to 1,000 nm, and the wavelength resolution is approximately 3 nm. The illumination system consists of narrowband blue, ultraviolet, and other discrete wavelength light-emitting-diode (LED) sources and white-light LED sources designed to produce consistently spatially stable light. White LEDs provide illumination for the measurement of reflectance spectra, while narrowband blue and UV LEDs are used to excite fluorescence. Each spectral type of LED can be turned on or off depending on the specific remote-sensing process being performed. Uniformity of illumination is achieved by using an array of LEDs and/or an integrating sphere or other diffusing surface. The image plane scanner uses a fore optic with a field of view large enough to provide an entire scan line on the image plane. It builds up a two-dimensional image in pushbroom fashion as the target is scanned across the image plane either by moving the object or moving the fore optic. For fluorescence detection, spectral filtering of a narrowband light illumination source is sometimes necessary to minimize the interference of the source spectrum wings with the fluorescence signal. Spectral filtering is achieved with optical interference filters and absorption glasses. This dual spectral imaging capability will enable the optimization of reflective, fluorescence, and fused datasets as well as a cost-effective design for multispectral imaging solutions. This system has been used in plant stress detection studies and in currency analysis.

Ryan, Robert E.↗

Spatial and spectral resolution necessary for remotely sensed vegetation studies

An outline is presented of the required spatial and spectral resolution needed for accurate vegetation discrimination and mapping studies as well as for determination of state of health (i.e., detection of stress symptoms) of actively growing vegetation. Good success was achieved in vegetation discrimination and mapping of a heterogeneous forest cover in the ridge and valley portion of the Appalachians using multispectral data acquired with a spatial resolution of 15 m (IFOV). A sensor system delivering 10 to 15 m spatial resolution is needed for both vegetation mapping and detection of stress symptoms. Based on the vegetation discrimination and mapping exercises conducted at the Lost River site, accurate products (vegetation maps) are produced using broad-band spectral data ranging from the .500 to 2.500 micron portion of the spectrum. In order of decreasing utility for vegetation discrimination, the four most valuable TM simulator VNIR bands are: 6 (1.55 to 1.75 microns), 3 (0.63 to 0.69 microns), 5 (1.00 to 1.30 microns) and 4 (0.76 to 0.90 microns).

Rock, B. N.↗

Fine Particulate Matter Predictions Using High Resolution Aerosol Optical Depth (AOD) Retrievals

To date, spatial-temporal patterns of particulate matter (PM) within urban areas have primarily been examined using models. On the other hand, satellites extend spatial coverage but their spatial resolution is too coarse. In order to address this issue, here we report on spatial variability in PM levels derived from high 1 km resolution AOD product of Multi-Angle Implementation of Atmospheric Correction (MAIAC) algorithm developed for MODIS satellite. We apply day-specific calibrations of AOD data to predict PM(sub 2.5) concentrations within the New England area of the United States. To improve the accuracy of our model, land use and meteorological variables were incorporated. We used inverse probability weighting (IPW) to account for nonrandom missingness of AOD and nested regions within days to capture spatial variation. With this approach we can control for the inherent day-to-day variability in the AOD-PM(sub 2.5) relationship, which depends on time-varying parameters such as particle optical properties, vertical and diurnal concentration profiles and ground surface reflectance among others. Out-of-sample "ten-fold" cross-validation was used to quantify the accuracy of model predictions. Our results show that the model-predicted PM(sub 2.5) mass concentrations are highly correlated with the actual observations, with out-of- sample R(sub 2) of 0.89. Furthermore, our study shows that the model captures the pollution levels along highways and many urban locations thereby extending our ability to investigate the spatial patterns of urban air quality, such as examining exposures in areas with high traffic. Our results also show high accuracy within the cities of Boston and New Haven thereby indicating that MAIAC data can be used to examine intra-urban exposure contrasts in PM(sub 2.5) levels.

aerosol optical depth↗

Coronal fine structure as seen in the Skylab white light coronagraph

The white light coronograph (WLC) on Skylab provided an opportunity to study the corona at high spatial and temporal resolution. The spatial resolution of the instrument was approximately 25 cm with images taken approximately one per min. One set of images taken over a 10 min period was digitized, providing ten high spatial resolution images for analysis. The progress in data processing techniques available at the time was not sufficient to permit a reliable study of the fine structure in these images. Using current techniques an investigation of the sizes and lifetimes of the smallest scale features in the data was carried out. A preliminary analysis of an area between 2 and 3 Ro was completed. The results show that very narrow rays extend from at least 2 to 3 Ro. The narrowest of these rays has a thickness of approximately 75 cm. The contrast is so low that they are very close to the noise limit of the data. Most of the rays observed become unrecognizable after 10 min, although some remain visible over the entire time. Some notion seems to be detectable in the fine structure rays, but analysis of more frames will be needed to quantify these results.

Poland, Arthur I.↗

Planetary investigation utilizing an imaging spectrometer system based upon charge injection technology

An intrinsic silicon charge injection device (CID) television sensor array has been used in conjunction with a CaMoO4 colinear tunable acousto optic filter, a 61 inch reflector, a sophisticated computer system, and a digital color TV scan converter/computer to produce near IR images of Saturn and Jupiter with 10A spectral resolution and approximately 3 inch spatial resolution. The CID camera has successfully obtained digitized 100 x 100 array images with 5 minutes of exposure time, and slow-scanned readout to a computer. Details of the equipment setup, innovations, problems, experience, data and final equipment performance limits are given.

Wattson, R. B.↗

The University of Colorado OSO-8 spectrometer experiment. I - Introduction and optical design considerations

The optical design of the high-resolution ultraviolet spectrometer prepared for the OSO-8 spacecraft is discussed. The instrument is a conventional 1 m Ebert-Fastie spectrometer fed by a Cassegrainian telescope. The instrument operates in the spectral range 1200-2000 A with spectral resolution of order 0.02 A. Spatial resolution is about 2.5 arcsec normal to the direction of the slit and is selectable from about 3 arcsec to 15 arcmin along the direction of the slit. Time resolution for the single spectrometer channel is selectable according to the needs of an individual observation and is limited to a maximum sampling rate of 40 ms per data point. The instrument is controlled by an internal general purpose computer.

Bruner, E. C., Jr.↗

Science support for the atmospheric trace molecule spectroscopy (ATMOS) experiment

The experiment is a satellite solar occultation interferometer spectrometer experiment under development for flight on Spacelab 3. Launch is expected in March 1985. ATMOS will provide high spectral resolution (0.02/cm) and high spatial resolution (2 km from Shuttle altitude) data over the spectral range from 2 micrometers to 16 micrometers. This region of the spectrum is rich in absorption features of major and minor trace gases which are critical to the understanding of the chemistry and physics of the Earth's upper atmosphere. The broad objectives of the ATMOS experiment are to: identify and measure, on a global scale, the volume mixing ratios of known and newly discovered molecular species; determine vertical profiles for these species; and provide spectral data on the atmosphere for use in optimizing the design of future instruments to monitor specific gases.

Rinsland, C. P.↗

Single-pulse, laser-saturated fluorescence measurements of OH in turbulent nonpremixed flames

A single-pulse, laser-saturated fluorescence technique has been developed for absolute OH concentration measurements with a temporal resolution of 2 nsec, a spatial resolution of less than 0.1 cu mm, and an estimated accuracy of + or - 30 percent. It has been applied in laminar, transitional, and turbulent hydrogen-air diffusion flames, providing the first reported quantitative measurements of average values, rms fluctuations, and probability-density functions of OH-radical concentration in nonpremixed flames.

Lucht, R. P.↗

A broad band X-ray imaging spectrophotometer for astrophysical studies

A broadband X-ray imaging spectrophotometer (BBXRIS) has been built for astrophysical studies. The BBXRIS is based on a large-imaging gas scintillation proportional counter (LIGSPC), a combination of a gas scintillation proportional counter and a multiwire proportional counter, which achieves 8 percent (FWHM) energy resolution and 1.5-mm (FWHM) spatial resolution at 5.9 keV. The LIGSPC can be integrated with a grazing incidence mirror and a coded aperture mask to provide imaging over a broad range of X-ray energies. The results of tests involving the LIGSPC and a coded aperture mask are presented, and possible applications of the BBXRIS are discussed.

Lum, Kenneth S. K.↗

Measurement and modeling of moist processes

The keynote talk summarized five years of work simulating observed mesoscale convective systems with the RAMS (Regional Atmospheric Modeling System) model. Excellent results are obtained when simulating squall line or other convective systems that are strongly forced by fronts or other lifting mechanisms. Less highly forced systems are difficult to model. The next topic in this colloquium was measurement of water vapor and other constituents of the hydrologic cycle. Impressive accuracy was shown measuring water vapor with both the airborne DIAL (Differential Absorption Lidar) system and the the ground-based Raman Lidar. NMC's plans for initializing land water hydrology in mesoscale models was presented before water vapor measurement concepts for GCIP were discussed. The subject of using satellite data to provide mesoscale moisture and wind analyses was next. Recent activities in modeling of moist processes in mesoscale systems was reported on. These modeling activities at the Canadian Atmospheric Environment Service (AES) used a hydrostatic, variable-resolution grid model. Next the spatial resolution effects of moisture budgets was discussed; in particular, the effects of temporal resolution on heat and moisture budgets for cumulus parameterization. The conclusion of this colloquium was on modeling scale interaction processes.

Cotton, William↗

Mapping minerals, amorphous materials, environmental materials, vegetation, water, ice and snow, and other materials: The USGS tricorder algorithm

One of the challenges of Imaging Spectroscopy is the identification, mapping and abundance determination of materials, whether mineral, vegetable, or liquid, given enough spectral range, spectral resolution, signal to noise, and spatial resolution. Many materials show diagnostic absorption features in the visual and near infrared region (0.4 to 2.5 micrometers) of the spectrum. This region is covered by the modern imaging spectrometers such as AVIRIS. The challenge is to identify the materials from absorption bands in their spectra, and determine what specific analyses must be done to derive particular parameters of interest, ranging from simply identifying its presence to deriving its abundance, or determining specific chemistry of the material. Recently, a new analysis algorithm was developed that uses a digital spectral library of known materials and a fast, modified-least-squares method of determining if a single spectral feature for a given material is present. Clark et al. made another advance in the mapping algorithm: simultaneously mapping multiple minerals using multiple spectral features. This was done by a modified-least-squares fit of spectral features, from data in a digital spectral library, to corresponding spectral features in the image data. This version has now been superseded by a more comprehensive spectral analysis system called Tricorder.

Clark, Roger N.↗

GEO Sounding Using Microwave Instruments

There are several microwave instruments in low Earth orbit (LEO) that are used for atmospheric temperature and humidity sounding in conjunction with companion IR sounders as well as by themselves. These instruments have achieved a certain degree of maturity and undergoing a redesign to minimize their size, mass, and power from the previous generation instruments. An example of these instruments is the AMSU-A series, now flying on POES and AQUA spacecraft with the IR sounders HIRS and AIRS. These older microwave instruments are going to be replaced by the ATMS instruments that will fly on NPP and NPOESS satellites with the CrIS sounder. A number of techniques learned from the ATMS project in instrument hardware design and data processing are directly applicable to a similar microwave sounder on a geosynchronous platform. These techniques can significantly simplify the design of a Geostationary orbit (GEO) microwave instrument, avoiding costly development and minimizing the risk of not being able to meet the scientific requirements. In fact, some of the 'enabling' technology, such as the use of MMIC microwave components (which is the basis for the ATMS' much reduced volume) can be directly applied to a GEO sounder. The benefits of microwave sounders are well known; for example, they penetrate non-precipitating cloud cover and allow for use of colocated IR observations in up to 80% cloud cover. The key advantages of a microwave instrument in GEO will be the ability to provide high temporal resolution as well as uniform spatial resolution and extend the utility of a colocated advanced IR sounder to cases in which partial cloud cover exists. A footprint of the order of 100 km by 100 km resolution with hemispherical coverage within one hour can be easily achieved for sounding channels in the 50 to 59 GHz range. A GEO microwave sounder will also allow mesoscale sampling of select regions.

Shiue, James↗

Spectral behavior of hydrated sulfate salts: implications for Europa mission spectrometer design

Remote sensing of the surface of Europa with near-infrared instruments has suggested the presence of hydrated materials, including sulfate salts. Attention has been focused on these salts for the information they might yield regarding the evolution of a putative interior ocean, and the evaluation of its astrobiological potential. These materials exhibit distinct infrared absorption features due to bound water. The interactions of this water with the host molecules lead to fine structure that can be used to discriminate among these materials on the basis of their spectral behavior. This fine structure is even more pronounced at the low temperatures prevalent on icy satellites. Examination of hydrated sulfate salt spectra measured under cryogenic temperature conditions provides realistic constraints for future remote-sensing missions to Europa. In particular, it suggests that a spectrometer system capable of 2-5 nm spectral resolution or better, with a spatial resolution approaching 100 m, would be able to differentiate among proposed hydrated surface materials, if present, and constrain their distributions across the surface. Such information would provide valuable insights into the evolutionary history of Europa.

Astronomy↗

Hyperspectral Imager-Tracker

The Hyperspectral Imager-Tracker (HIT) is a technique for visualization and tracking of low-contrast, fast-moving objects. The HIT architecture is based on an innovative and only recently developed concept in imaging optics. This innovative architecture will give the Light Prescriptions Innovators (LPI) HIT the possibility of simultaneously collecting the spectral band images (hyperspectral cube), IR images, and to operate with high-light-gathering power and high magnification for multiple fast- moving objects. Adaptive Spectral Filtering algorithms will efficiently increase the contrast of low-contrast scenes. The most hazardous parts of a space mission are the first stage of a launch and the last 10 kilometers of the landing trajectory. In general, a close watch on spacecraft operation is required at distances up to 70 km. Tracking at such distances is usually associated with the use of radar, but its milliradian angular resolution translates to 100- m spatial resolution at 70-km distance. With sufficient power, radar can track a spacecraft as a whole object, but will not provide detail in the case of an accident, particularly for small debris in the onemeter range, which can only be achieved optically. It will be important to track the debris, which could disintegrate further into more debris, all the way to the ground. Such fragmentation could cause ballistic predictions, based on observations using high-resolution but narrow-field optics for only the first few seconds of the event, to be inaccurate. No optical imager architecture exists to satisfy NASA requirements. The HIT was developed for space vehicle tracking, in-flight inspection, and in the case of an accident, a detailed recording of the event. The system is a combination of five subsystems: (1) a roving fovea telescope with a wide 30 field of regard; (2) narrow, high-resolution fovea field optics; (3) a Coude optics system for telescope output beam stabilization; (4) a hyperspectral-mutispectral imaging assembly; and (5) image analysis software with effective adaptive spectral filtering algorithm for real-time contrast enhancement.

Agurok, Llya↗

Hyperspectral Thermal Emission Spectrometer: Engineering Flight Campaign

The Hyperspectral Thermal Emission Spectrometer (HyTES) successfully completed its first set of engineering test flights. HyTES was developed in support of the Hyperspectral Infrared Imager (HyspIRI). HyspIRI is one of the Tier II Decadal Survey missions. HyTES currently provides both high spectral resolution (17 nm) and high spatial resolution (2-5m) data in the thermal infrared (7.5-12 micron) part of the electromagnetic spectrum. HyTES data will be used to help determine the optimum band positions for the HyspIRI Thermal Infrared (TIR) sensor and provide antecedent data for HyspIRI related studies.

HyTES↗