Method for Determining the Estimated Timing Uncertainty for Digital Sampling Instruments .
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
The transport of conserved quantities like spin and charge is fundamental to characterizing the behavior of quantum many-body systems. Numerically simulating such dynamics is generically challenging, which motivates the consideration of quantum computing strategies. However, the relatively high gate errors and limited coherence times of today's quantum computers pose their own challenge, highlighting the need to be frugal with quantum resources. In this work we report simulations on quantum hardware of infinite-temperature energy transport in the mixed-field Ising chain, a paradigmatic many-body system that can exhibit a range of transport behaviors at intermediate times. We consider a chain with L = 12 sites and find results broadly consistent with those from ideal circuit simulators over 90 Trotter steps, containing up to 990 entangling gates. To obtain these results, we use two key problem-tailored insights. First, we identify a convenient basis – the Pauli Y basis – in which to sample the infinite-temperature trace and provide theoretical and numerical justifications for its efficiency relative to, e.g., the computational basis. Second, in addition to a variety of problem-agnostic error mitigation strategies, we employ a renormalization strategy that compensates for global nonconservation of energy due to device noise. We discuss the applicability of the proposed sampling approach beyond the mixed-field Ising chain and formulate a variational method to search for a sampling basis with small sample-to-sample fluctuations for an arbitrary Hamiltonian. This opens the door to applying these techniques in more general models.
Explore the source record for details and available documents.
Abstract The bioenergy crops such as energycane, miscanthus, and sorghum are being genetically modified using state of the art synthetic biotechnology techniques to accumulate energy‐rich molecules such as triacylglycerides (TAGs) in their vegetative cells to enhance their utility for biofuel production. During the initial genetic developmental phase, many hundreds of transgenic phenotypes are produced. The efficiency of the production pipeline requires early and minimally destructive determination of oil content in individuals. Current screening methods require time‐intensive sample preparation and extraction with chemical solvents for each plant tissue. A rapid screen will also be needed for developing industrial extraction as these crops become available. In the present study, we have devised a proton relaxation nuclear magnetic resonance ( 1 H‐NMR) method for single‐step, non‐invasive, and chemical‐free characterization of in‐situ lipids in untreated and pretreated lignocellulosic biomass. The systematic evaluation of NMR relaxation time distribution provided insight into the proton environment associated with the lipids in the biomass. It resolved two distinct lipid‐associated subpopulations of proton nuclei that characterize total in‐situ lipids into bound and free oil based on their “molecular tumbling” rate. The T1T2 correlation spectra also facilitated the resolution of the influence of various pretreatment procedures on the chemical composition of molecular and local 1 H population in each sample. Furthermore, we show that hydrothermally pretreated biomass is suitable for direct NMR analysis unlike dilute acid and alkaline pretreated biomass which needs an additional step for neutralization.
Ongoing and upcoming galaxy redshift surveys, such as the Dark Energy Spectroscopic Instrument (DESI) survey, will observe vast regions of sky and a wide range of redshifts. In order to model the observations and address various systematic uncertainties, N-body simulations are routinely adopted, however, the number of large simulations with sufficiently high mass resolution is usually limited by available computing time. Therefore, achieving a simulation volume with the effective statistical errors significantly smaller than those of the observations becomes prohibitively expensive. In this study, we apply the Convergence Acceleration by Regression and Pooling (CARPool) method to mitigate the sample variance of the DESI-like galaxy clustering in the AbacusSummit simulations, with the assistance of the quasi-N-body simulations FastPM. Based on the halo occupation distribution (HOD) models, we construct different FastPM galaxy catalogs, including the luminous red galaxies (LRGs), emission line galaxies (ELGs), and quasars, with their number densities and two-point clustering statistics well matched to those of AbacusSummit. We also employ the same initial conditions between AbacusSummit and FastPM to achieve high cross-correlation, as it is useful in effectively suppressing the variance. Our method of reducing noise in clustering is equivalent to performing a simulation with volume larger by a factor of 5 and 4 for LRGs and ELGs, respectively. We also mitigate the standard deviation of the LRG bispectrum with the triangular configurations k 2 = 2k 1 = 0.2 h Mpc -1 by a factor of 1.6. With smaller sample variance on galaxy clustering, we are able to constrain the baryon acoustic oscillations (BAO) scale parameters to higher precision. The CARPool method will be beneficial to better constrain the theoretical systematics of BAO, redshift space distortions (RSD) and primordial non-Gaussianity (NG).
Here we report an experimental setup for simultaneously measuring specific heat and thermal conductivity in feedback-controlled pulsed magnetic fields of 50 ms duration at cryogenic temperatures. A stabilized magnetic field pulse obtained by the feedback control, which dramatically improves the thermal stability of the setup and sample, is used in combination with the flash method to obtain absolute values of thermal properties up to 37.2 T in the 22–16 K temperature range. We describe the experimental setup and demonstrate the performance of the present method with measurements on single-crystal samples of the geometrically frustrated quantum spin-dimer system SrCu 2 (BO 3 ) 2 . Our proof-of-principle results show excellent agreement with data taken using a standard steady-state method, confirming the validity and convenience of the present approach.
ABSTRACT Obtaining accurately calibrated redshift distributions of photometric samples is one of the great challenges in photometric surveys like LSST, Euclid, HSC, KiDS, and DES. We present an inference methodology that combines the redshift information from the galaxy photometry with constraints from two-point functions, utilizing cross-correlations with spatially overlapping spectroscopic samples, and illustrate the approach on CosmoDC2 simulations. Our likelihood framework is designed to integrate directly into a typical large-scale structure and weak lensing analysis based on two-point functions. We discuss efficient and accurate inference techniques that allow us to scale the method to the large samples of galaxies to be expected in LSST. We consider statistical challenges like the parametrization of redshift systematics, discuss and evaluate techniques to regularize the sample redshift distributions, and investigate techniques that can help to detect and calibrate sources of systematic error using posterior predictive checks. We evaluate and forecast photometric redshift performance using data from the CosmoDC2 simulations, within which we mimic a DESI-like spectroscopic calibration sample for cross-correlations. Using a combination of spatial cross-correlations and photometry, we show that we can provide calibration of the mean of the sample redshift distribution to an accuracy of at least 0.002(1 + z), consistent with the LSST-Y1 science requirements for weak lensing and large-scale structure probes.
A precision polymer featuring one phenyl pendant at every fifth carbon on a polyethylene backbone was modified to varying degrees of sulfonation (DS = 33–98%) using acetyl sulfate with standard conditions by varying reaction times (up to 48 h). This soft, homogeneous method allows for evenly distributed phenylsulfonic acid groups with minimal side reactions and results in light brown, transparent materials with glass transition temperatures of 33–78 °C that increase with DS and parent polymer molar mass. The DS was accurately determined through well-resolved 1 H NMR (DSHNMR) signals of the regularly spaced phenyl groups and corroborated by inverse-gated decoupling 13 C NMR analysis. These analyses were compared to a series of other commonly accepted methods for DS determination including titration and elemental analysis (EA). The DS by titration (DS titr ) also increased with reaction time but was consistently lower than those determined by NMR. Significant discrepancies between theoretical and measured sulfur mass were observed for several samples through EA. Qualitative methods, such as infrared spectroscopy and thermal analyses, were also performed and correlated well with the DS determined by NMR. Here, this study presents a promising method to achieve a complete scope of homogeneous sulfonation from mild reaction conditions and presents a case to determine DS through multiple methods, with spectroscopic analyses, such as NMR, being potentially the most valuable.
An ultra-microtome method is developed for the preparation of transmission electron microscopy (TEM) specimens from the cathodes of Li-ion battery. Results indicate that the samples prepared with the ultra-microtome method yield atomic resolution imaging from the core area of particles of hundreds to thousands of nanometers. Analysis of the TEM samples prepared with ultra-microtome indicates that no observable structural damage, such as microcracking, is introduced during the cutting process, and the cathodes cut by ultra-microtome exhibit unchanged micro-morphologies compared with the uncut ones. These results demonstrate that ultra-microtome is a promising method for the preparation of TEM specimens and revealing in-depth microstructures of fragile materials such as battery cathodes.
Uptake of noble gases into heterogeneous geologic core samples was measured using a piezometric methodology. In addition to measuring accessible porosity—as with gas pycnometry—by monitoring the rate of pressure decay, this method can also be used to estimate the gas effective diffusivity in the sample. In contrast to previous applications of this method, where milligram quantities of fractured grains are characterized, here approximately kilogram core samples were left intact when tested. In doing so, a more representative sample of the heterogeneous field geology is provided. Additionally, alteration of the pore structure and connectivity during sample preparation is avoided. Furthermore, to scale the piezometric method from milligrams to kilograms, the system was designed to operate at medium vacuum (1 to 100 Pa) to restrict transport in pores less than approximately 60 µm to large Knudsen numbers. To test the system performance, two samples of interest were selected: a rhyolitic welded tuff from Blue Canyon Dome at the Energetic Materials Research and Testing Center and a zeolitized non-welded rhyolitic tuff from the Nevada National Security Site. Three noble gases were utilized in this test series; Argon and xenon as they are of direct interest to nuclear monitoring efforts and helium as it is a weakly adsorbing reference standard. Additionally, mercury intrusion porosimetry measurements were made on subsamples of the core to compare the observed porosity by the two methods and to discuss gas transport rates in the context of the measured pore distribution.
The invention generally relates to methods of analyzing crude oil. In certain embodiments, methods of the invention involve obtaining a crude oil sample, and subjecting the crude oil sample to mass spectrometry analysis. In certain embodiments, the method is performed without any sample pre-purification steps.
The invention generally relates to methods of analyzing crude oil. In certain embodiments, methods of the invention involve obtaining a crude oil sample, and subjecting the crude oil sample to mass spectrometry analysis. In certain embodiments, the method is performed without any sample pre-purification steps.
A central object in the computational studies of rare events is the committor function. Though costly to compute, the committor function encodes complete mechanistic information of the processes involving rare events, including reaction rates and transition-state ensembles. Under the framework of transition path theory, Rotskoff et al. [Proceedings of the 2nd Mathematical and Scientific Machine Learning Conference, Proceedings of Machine Learning Research (PLMR, 2022), Vol. 145, pp. 757–780] proposes an algorithm where a feedback loop couples a neural network that models the committor function with importance sampling, mainly umbrella sampling, which collects data needed for adaptive training. Here, in this work, we show additional modifications are needed to improve the accuracy of the algorithm. The first modification adds elements of supervised learning, which allows the neural network to improve its prediction by fitting to sample-mean estimates of committor values obtained from short molecular dynamics trajectories. The second modification replaces the committor-based umbrella sampling with the finite-temperature string (FTS) method, which enables homogeneous sampling in regions where transition pathways are located. We test our modifications on low-dimensional systems with non-convex potential energy where reference solutions can be found via analytical or finite element methods, and show how combining supervised learning and the FTS method yields accurate computation of committor functions and reaction rates. We also provide an error analysis for algorithms that use the FTS method, using which reaction rates can be accurately estimated during training with a small number of samples. The methods are then applied to a molecular system in which no reference solution is known, where accurate computations of committor functions and reaction rates can still be obtained.
Accurate actinide measurements are critical within the field of nuclear science. Traditional methods for actinide quantification require time-consuming sample processing prior to analysis. There is a need for rapid analytical techniques that still maintain a high degree of accuracy. In this work, actinide reactivity was assessed for multiple oxygen-containing reaction gases using quadrupole inductively coupled plasma tandem mass spectrometry (Q-ICP-MS/MS) to evaluate actinide analysis in complex sample matrices without analyte-matrix separation. A novel method was developed to measure 241 Am/ 241 Pu in complex sample matrices using O 2 /He reaction gas with no matrix removal or analyte pre-concentration. This inline method reduces matrix-derived polyatomic interferences that complicate traditional ICP-MS analyses by mass-shifting to 241 Am 16 O + and 241 Pu 16 O 2 + , allowing Am and Pu to be mass separated for simultaneous analysis. While mass shifting is efficient, a small portion of Am + (<1.3%) and Pu + (<1.4%) react to from AmO 2 + and PuO + , respectively. Therefore, a mass balance approach was used, in combination with reactivity determined from 242 Pu and 243 Am standard solutions, to correct for residual 241 PuO + and 241 AmO 2 + . The method was validated by measuring 241 Am/ 241 Pu in Pu isotope standards CRM-136 and CRM-137 (separated in March/April 1970 and February 2022, respectively) in both neat solutions and complex matrices containing diluted soil (NIST SRM 2711a, >1000 µg·g -1 ). Method detection limits of 15.9 and 9.6 fg·g -1 were determined for 241 Am and 241 Pu, respectively, and 241 Am/ 241 Pu ratios were measured with accuracies within <3.5%. In conclusion, this work presents the first direct analysis of 241 Am/ 241 Pu in unseparated complex matrices, advancing capabilities for rapid actinide measurements.
Here, this study outlines the development and subsequent validation of a method using chelation ion chromatography (CIC) pretreatment followed by traditional ion chromatography (IC) and post column UV/vis detection to measure transition metals in fossil fuel wastewaters, such as oil & gas (O&G) brines and coal mine drainage (CMD) waters. Measurement of transition metals is often an important characterization step in the research of environmental and energy systems. IC represents one way to measure these metals with the advantages of being versatile, simple and relatively low cost compared to other analytical methods. However, high concentrations of alkali and alkaline earth metals present in fossil fuel wastewaters will decrease IC detectability of transition metals in these waters. In this study, a CIC method was developed for the analysis of transition metal ions (Fe 3+ , Cu 2+ , Ni 2+ , Zn 2+ , Co 2+ , Mn 2+ , and Fe 2+ ) in fossil fuel associated wastewaters such as Appalachian CMD and O&G wastewaters from the Permian and Bakken shale basins in the United States. CIC system incorporated an on-line chelator column (e.g., the MetPac CC-1) with high selectivity for transition metals over alkali and alkaline earth metals for salt matrix removal prior to transition metal separation and detection. Additional method developments also included acidifying all samples to 2% v/v HCl and using gradient elution rather than isocratic. The recoverability of transition metals in simple salt solutions commonly found in CMD and brine samples (e.g. NaCl, Na 2 SO 4 , CaCl 2 ) using CIC was evaluated and compared to that using traditional IC. Our results found that the CIC system significantly improved transition metal recoveries for samples in 10,000 mg/L CaCl 2 matrix, reaching 87%-108% recovery for all analytes, as opposed to 2-323% recovery in traditional IC. The limits of detection in this study achieved 10.09 – 161.2 μg/L, comparable to reported values in similar IC studies. The developed method was also verified with certified water samples, resulting in 89% - 111% recoveries in samples with higher analyte concentrations (i.e. >4x the LoDs). The developed method achieved 87% -112% recoveries for most analytes in CMD samples and 72%-138% recoveries for Bakken shale samples, relative to ICP-MS values. Overall, the current IC method can be a very good screening tool for fast and cheap analysis for transition metals at mg/L level, to facilitate selection of samples for more detailed ICP-MS analysis.
Neptune Fluid Flow Systems is a rising engineering firm with a technology focus in improving cryogenic sample preparation for cryogenic-transmission electron microscopy (cryo-TEM) studies. To advance the R&D of its innovative cryogenic preparation method, Neptune has teamed up with the Center for Nanophase Materials Science (CNMS) at Oak Ridge National Laboratory (ORNL) to achieve the following aims: (1) validate the technical feasibility of CryoSheet sample prep method, (2) design, fabricate and test the cryo-stage support, and (3) experiment and achieve success with the novel sample preparation method on different soft matters.
Abstract Surrogate-based Bayesian optimization has been widely applied in design optimization to increase sampling efficiency. However, the cost for each evaluation of the objective function can still be very high when physical experiments or large-scale simulations are involved. Multi-fidelity Bayesian optimization is the new approach to further improve the sampling efficiency by reducing the number of expensive samples at the highest fidelity level and supplementing them with less expensive ones at low-fidelity levels. In this paper, a new consequential improvement (CI) acquisition function is proposed to allow for the simultaneous selection of the solution and the fidelity level in problems with a known hierarchy of fidelity levels. The new CI acquisition function incorporates the consequential effectiveness of objective improvement with the considerations of cost, accuracy, and validity differences between high- and low-fidelity samples in engineering practice. The new method of multi-fidelity Bayesian optimization based on the CI is demonstrated with several analytical and simulation-based design examples. In the simulation-based design optimization example, the results show that the CI acquisition function has a decisive advantage in the sampling efficiency over the other methods of multi-fidelity Bayesian optimization with simultaneous selection. The results indicate that the proposed method is particularly advantageous in solving high-dimensional problems and when large cost ratios between high- and low-fidelity evaluations exist and high-fidelity validation is mandatory. Furthermore, the method robustly avoids the prevalent issue of over sampling at low-fidelity levels.
Residual resistance ratio (RRR) of superconducting strands is an important parameter for magnet electrical stability. RRR serves as a measure of the low-temperature electrical conductivity of the copper within a conductor that has a copper stabilization matrix. For Nb 3 Sn, due to the need of a reaction heat treatment, the technical requirements for high quality measurements of strands extracted from Rutherford cables are particularly demanding. Quality of wire, cabling deformation, heat treatment temperature, heat treatment atmosphere, sample handling, and measurement methods can all affect the RRR. Therefore, as an integral part of the electrical quality control (QC) of Nb 3 Sn Rutherford cables manufactured at the Lawrence Berkeley National Laboratory, it was prudent that we established a RRR measurement system that can isolate the assessment of cable-fabrication-related impacts from sample preparation and measurement factors. Here we describe a bespoke cryocooler-based measurement system, capable of measuring RRR of over 80 samples in a single cooldown. The samples are mounted on custom-designed printed circuit boards that accommodate the shape of strands extracted from a Rutherford cable without added deformation, which we will show is critical in ensuring that the measurements accurately represent the RRR values of the conductor within the cable. Using this sample mounting solution, we routinely measure the overall RRR of the strand as well as individual intra-strand sections corresponding to both cable edges and cable broad faces with high reproducibility. Such measurements provide valuable information on the variation of RRR along the length of the strands as well as across strand productions and cable runs over time.