Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reliability study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

A Prognostic Launch Vehicle Probability of Failure Assessment Methodology for Conceptual Systems Predicated on Human Causal Factors

Create an improved method to calculate reliability of a conceptual launch vehicle system prior to fabrication by using historic data of actual root causes of failures. While failures have unique "proximate causes", there are typically a finite amount of common "root causes". Heretofore launch vehicle reliability evaluation typically hardware-centric statistical analyses, while most root causes of failures are been shown to be human-centric. A method based on human-centric root causes can be used to quantify reliability assessments and focus proposed actions to mitigate problems. Existing methods have been optimistic in their projections of launch vehicle reliability compared to actuals. Hypothesis: reliability of a conceptual launch vehicle can be more accurately evaluated based on a rational, probabilistic approach using past failure assessment teams' findings predicated on human-centric causes."Human Reliability Analysis Methods Selection Guidance for NASA"Chandler F.T., et al., NASA HQ/OSMA study group, July 2006. Outside HRA experts from academia, other federal labs, and the private sector. 50 system reliability methods considered, fourteen selected for further study, four finally selected as best suited for human spaceflight. Probabilistic Risk Analysis (PRA) + Human Reliability Analysis (HRA) enabled incorporating effects and probabilities of human errors. While four down-selected methods deemed appropriate for failure assessment, it did not appear that these methods could be concisely applied to perform major system-wide assessment of probability of failure of a conceptual design without becoming unwieldy."Engineering a Safer World", Detailed, comprehensive study external to NASA Leveson N. G., MIT, 2011.Systems-Theoretic Accident Model and Processes (STAMP). All-encompassing accident model based on systems theory analyzed accidents after they occurred and created approaches to prevent occurrence in developing systems not focused on failure prevention per se, but rather reducing hazards by influencing human behavior through use of constraints, hierarchical control structures, and process models to improve system safetySystem Theoretic Process Analysis (STPA) addresses predictive part of problem (a "hazard analysis"). Includes all causal factors identified in STAMP: "...design errors, software flaws, component interaction accidents, cognitively complex human decision-making errors, and social organizational and management factors contributing to accidents" can guide design process rather than require it to exist before-hand did not appear capable of concise application for system-wide assessment of probability of failure of a conceptual design without becoming unwieldy.

Williams, Craig H.↗

Enhanced Component Performance Study: Air-Operated Valves 1998–2020

This report presents an enhanced performance evaluation of air-operated valves (AOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2020 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The AOV failure modes considered are failure-to-open/close (FTOC), failure to operate or control (FTOP), and spurious operation (SO). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following trends were identified for the most recent 10-year period: o Extremely statistically significant increasing trend for the frequency of FTOC demands (demands per reactor year) for low-demand (= 20 demands per year) AOVs o Extremely statistically significant increasing trend for the frequency of FTOC demands for high-demand (> 20 demands per year) AOVs o Highly statistically significant decreasing trend for the failure rate of FTOP for low-demand AOVs o Highly statistically significant decreasing trend for the frequency of FTOP events (failures per reactor year) for low-demand AOVs o Statistically significant decreasing trend for the failure rate of SO for low-demand AOVs o Statistically significant decreasing trend for the frequency of SO events (failures per reactor year) for low-demand AOVs.

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Motor-Operated Valves 1998-2020

This report presents an enhanced performance evaluation of motor-operated valves (MOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2020 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MOV failure modes considered are fail to open or close (FTOC), fail to operate or control (FTOP), and spurious operation (SO). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trend was identified for MOVs for the most recent 10-year period: • Low-demand MOV frequency of FTOC demands (demands per reactor year). The following increasing trends were identified for MOVs for the most recent 10-year period: • Low-demand MOV FTOC failure probability • Low-demand MOV frequency of FTOC events (failures per reactor year).

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Motor Operated Valves 1998–2022

This report presents an enhanced performance evaluation of motor-operated valves (MOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2022 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MOV failure modes considered are fail to open or close (FTOC), fail to operate or control (FTOP), and spurious operation (SO). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trend was identified for MOVs for the most recent 10-year period: • Low-demand MOV frequency of FTOC demands (demands per reactor year). The following decreasing trends were identified for MOVs for the most recent 10-year period: • Low-demand MOV FTOC failure probability • Low-demand MOV frequency of FTOC events (failures per reactor year).

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Air Operated Valves 1998–2022

This report presents an enhanced performance evaluation of air operated valves (AOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2022 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The AOV failure modes considered are fail to open or close (FTOC), fail to operate or control (FTOP), and spurious operation (SO). The component reliability estimates and the reliability data are trended for the most recent 10 year period while yearly estimates for reliability are provided for the entire study period. The following increasing trends were identified for AOVs for the most recent 10 year period: • Low demand AOV frequency of FTOC demands (demands per reactor year) • High demand AOV frequency of FTOC demands. The following decreasing trends were identified for AOVs for the most recent 10 year period: • Low demand AOV FTOC failure probability • Low demand AOV FTOP failure rate • Low demand AOV frequency of FTOC events (failures per reactor year) • Low demand AOV frequency of FTOP events.

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Motor-Operated Valves 1998-2024

This report presents an enhanced performance evaluation of motor-operated valves (MOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2024 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MOV failure modes considered are fail to open or close (FTOC), fail to operate or control (FTOP), and spurious operation (SO). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trend was identified for MOVs for the most recent 10-year period: • Low-demand MOV frequency of FTOC demands (demands per reactor year). The following decreasing trends were identified for MOVs for the most recent 10-year period: • Low-demand MOV FTOC failure probability • High-demand MOV SO failure rate • Low-demand MOV frequency of FTOC events (failures per reactor year) • High-demand MOV frequency of SO events (failures per reactor year).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design guidelines for use of adhesives and organic coatings in hybrid microcircuits

A study was conducted to investigate the reliability of organic adhesives in hybrid microcircuits. The objectives were twofold: (1) to identify and investigate problem areas that could result from the use of organic adhesives and (2) to develop evaluation tests to quantify the extent to which these problems occur for commercially available adhesives. Efforts were focused on electrically conductive adhesives. Also, a study was made to evaluate selected organic coatings for contamination protection for hybrid microcircuits.

Caruso, S. V.↗

Automated, reliable, and efficient continental-scale replication of 7.3 petabytes of computational simulation data: A case study

We report on our experiences replicating 7.3 petabytes (PB) of Earth System Grid Federation (ESGF) computational simulation data from Lawrence Livermore National Laboratory (LLNL) in California to Argonne National Laboratory (ANL) in Illinois and Oak Ridge National Laboratory (ORNL) in Tennessee—a task motivated by a need for increased reliability, capacity, and performance. This task presented significant challenges: the need to move 29 million files twice under time pressure from aging storage hardware; a source file system bottleneck limiting throughput to 1.5 GB/s; frequent site maintenance windows; and the need for complete reliability at scale. We addressed these challenges using a simple replication tool that invoked Globus to transfer large bundles of files while tracking progress in a database, dynamically rerouting transfers to work around maintenance periods and file system limitations. Under the covers, Globus organized transfers to make efficient use of the high-speed Energy Sciences network (ESnet) and the data transfer nodes deployed at participating sites, and also addressed security, integrity checking, and recovery from a variety of transient failures. This success demonstrates the considerable benefits that can accrue from the adoption of performant data replication infrastructure. The replication tool is available at https://github.com/esgf2-us/data-replication-tools.

Globus↗

Modeling of multi-component precipitation and crystallization for zero-liquid-discharge desalination

This study proposes novel ZLD treatment trains that integrate multi-component chemical precipitation and multi-effect evaporative crystallization for efficient brine management. The methodology emphasizes sustainability by integrating CO₂ for chemical precipitation and reducing environmental impact, exemplified with two case studies: produced water that includes industrial waste heat utilization by adopting the emerging vacuum air-gapped membrane distillation (VAGMD) technology, and brackish groundwater that is abundant in sulphate which undergoes treatment by low-salt-rejection reverse osmosis (LSRRO) with interstage chemical precipitation. Here, this study is the first of its kind to simultaneously account for reducing risk of mineral scaling and effective recovery of valuable solids when incorporating VAGMD and LSRRO in ZLD treatment trains. Using Reaktoro and WaterTAP, both Python-based, open-source platforms, we model the recovery of high-purity magnesium, calcium, and sodium salts while optimizing energy consumption and operational efficiency in proposed ZLD pathways for case studies of produced water and brackish desalination brine management. Validation with experimental and reference data confirms the reliability of the models used. In both case studies, the optimized ZLD process achieves recovery rates of 97%, 99%, and 90% for Mg, Ca, and Na, with purities exceeding 99%, and brine volume reduced to less than 4% of the initial feed flow.

3D CT scans↗

Saturn component failure rate and failure rate modifiers

Failure mode frequency ratios, environmental adjustment factors, and failure rates for mechanical and electromechanical component families are presented. The failure rates and failure rate modifiers resulted from a series of studies whose purpose was to provide design, tests, reliability, and systems engineers with accurate, up-to-date failure rate information. The results of the studies were achieved through an extensive engineering analysis of the Saturn Program test data and Unsatisfactory Condition Reports (UCR's) and the application of mathematical techniques developed for the studies.

Source record↗

Data Collection and Analysis Challenges and Mitigation Strategies for Quantitative Human Factors Research Studies in Nuclear Power Plant Modernization

The United States (U.S.) Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program Plant Modernization Pathway is conducting targeted research and development (R&D) to address aging and reliability concerns with the legacy instrumentation and control and related information systems of the U.S. LWR fleet. In this effort, the application of human factors engineering (HFE) provides an important role in ensuring new digital plant technologies enable broad innovation and business improvement with continued operational safety. Evaluation is a key activity in HFE, which often occurs iteratively through the system design lifecycle. While qualitative methods are important in collecting information of how users perform tasks through observations, quantitative methods are equally important in assessing system design based on performance. In collecting and analyzing this quantitative data, there are notable challenges in the nuclear HFE domain that may threaten the validity and reliability of the inferences made in these studies. Notable challenges include small sample size and limited resources, large error variance and small effect size, an “adding test features to losing degrees of freedom” dilemma, non-normal distribution, and heterogeneity of variance. The results in control room usability studies are often statistically non-significant, which makes it hard to interpret. This work discusses these challenges across different scientific viewpoints and provides real-world examples of these challenges in practice. Collectively, the objective of this work is to position these challenges to the larger data science community as a means of identifying future opportunities to address these issues.

99 GENERAL AND MISCELLANEOUS↗

Can portable glucose and lactate meters be a useful tool in quantifying stress of juvenile Chinook salmon?

Blood plasma analyses can provide researchers, aquaculture facilities and fisheries managers with valuable insights into the physiological state and welfare of fish. For example, glucose and lactate are part of the secondary stress response system, and elevated concentrations are indicators of stress. However, analysing blood plasma in the field can be logistically difficult and typically involves sample storage and transport to quantify concentrations in a laboratory setting. Portable glucose and lactate meters offer an alternative to laboratory assays and have shown to be relatively accurate in fish, but these tools have only been validated for a few fish species. The objective of this study was to investigate if portable meters could be reliably used in Chinook salmon (Oncorhynchus tshawytscha). As part of a larger stress response study, juvenile Chinook salmon (157 ± 17 mm fork length [mean ± standard deviation; SD]) were exposed to stress-inducing treatments and sampled for blood. Laboratory reference glucose concentrations (milligrams per deciliter; mg/dl; n = 70) were positively correlated with the Accu-Check Aviva meter (Roche Diagnostics, Indianapolis, IN) measurements (R 2 = 0.79), although glucose values were 1.21 ± 0.21 (mean ± SD) times higher in the laboratory than with the portable meter. Lactate concentrations (milliMolar; mM; n = 52) of the laboratory reference were also positively correlated (R 2 = 0.76) with the Lactate Plus meter (Nova Biomedical, Waltham, MA) and were 2.55 ± 0.50 times higher than portable meter. Our results indicate both meters could be used to measure relative glucose and lactate concentrations in Chinook salmon and provide fisheries professionals with a valuable tool, particularly in remote field settings.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of Reactive Power on Photovoltaic Inverter Reliability and Lifetime

This paper performs research on predicting Photovoltaic (PV) inverters reliability and lifetime based on thermal cycling. Thermal cycling is considered the most important stressors in an inverter system. In order to achieve this, a detailed electro-thermal model of the PV inverter will be developed along with their controllers capable of providing voltage support through reactive power. An in-house inverter was built, and a PV inverter model was developed to match the physical inverter. The PV inverter electrothermal model was validated for different ambient temperatures to match the in-house inverter hardware. The in-house inverter was placed inside a thermal chamber to emulate different ambient temperatures and their losses and temperature rises within the system were measured. After the validation of the model, a reduced order model of the inverter will be implemented to translate the mission profile of ambient temperature and solar irradiance into load profile of junction temperatures of the switches. The junction temperature data will be used to identify the reliability indices and hence predict the useful lifetime of the inverter system. Along with the model to predict useful lifetime of the system, the impact of reactive power on the overall reliability of the system will be studied. The key observation in this paper shows that lifetime of the inverter decreases as the operating power factor moves away from unity.

14 SOLAR ENERGY↗

Conceptual Integration Studies of Localized Active Flow Control on the Wing of a Commercial Aircraft

A study of conceptual integration and performance of localized active flow control technology onto wings of short-to-medium-range project passenger airplanes is summarized. Using predicted aerodynamic performance improvement opportunities on a computational fluid dynamics reference aircraft, this paper presents the estimated performance opportunities for conceptual implementation of studied wing localized active flow control technology for low-speed (takeoff and landing) application on a Project Research Aircraft configuration. Using conceptual active flow control systems and structural integration weight penalties for studied concepts, potential relevant net performance benefits can be obtained with reliable active flow control in takeoff and landing. The conceptual integration study identifies potential localized wing active flow control application opportunities for high-lift conditions using energy sources available on modern aircraft. Material benefits are estimated for takeoff and landing configurations for selected localized wing active flow control applications. The study concluded that substantial low-speed Maximum Lift and Lift/Drag related performance improvements may be possible with localized wing high-lift active flow control systems powered by auxiliary power unit, engine bleed, or electrical compressors - with due consideration of integration and weight impacts as well as availability requirements of such systems.

drag reduction↗

Comparison of 70 deg tilt, LBNP, and passive standing as measures of orthostatic tolerance

The present study was performed to assess the reliability of lower body negative pressure (LBNP) as a test of orthostatic tolerance. The need for this assessment arose from the prior observation in this laboratory that some subjects show wide day-to-day variation in heart rate responses to LBNP. The extent of these variations was so great as to raise a serious question as to the value of LBNP as a measure of study-induced alterations (e.g., those produced by bedrest or weightlessness) in orthostatic tolerance. Five healthy volunteers were subjected to a series of tests, consisting of 70 deg tilt, LBNP, and passive standing, on three occasions preceding and three occasions following a 2-week period of bedrest. Study results show that it is possible to subdivide the volunteers into subgroups which show either great or little day-to-day variability in any of the three tests. All three tests revealed bedrest-induced alterations in orthostatic tolerance quite adequately. Of the three tests studied, LBNP most frequently resulted in the largest test-induced heart rate alterations, followed by quiet standing and, finally 70 deg tilt.

Hyatt, K. H.↗

National Transmission Planning Study - Long-Term Modeling Results

The National Transmission Planning Study (NTP Study) analyzed the transformation needed to ensure the U.S. transmission system continues to reliably meet electricity demand as the power sector evolves. The study linked several long- and short-term power systems models to test numerous interregional and regional transmission buildout scenarios. The results included in this dataset are from the long-term capacity expansion modeling, completed with NREL's ReEDS model. This includes nearly 100 future transmission scenarios with a wide range of economic, reliability, and resilience conditions. The dataset includes all the results visualized in the Tableau Public site, as linked below.

Array↗

Multiscale Characterization of Photovoltaic Modules—Case Studies of Contact and Interconnect Degradation

The current popularity of photovoltaic (PV) systems is due in large part to their exceptional reliability and significantly lower cost than other energy sources. Studying cell and module degradation is key to promote further development in the state of the art. Fielded or accelerated aged modules exhibit different failure modes, of which metallization degradation (contacts and interconnections) is prevalent. In this work, we discuss how multiscale characterization methods can be applied to a variety of module technologies that have been field exposed and have undergone accelerated age testing. These methods include performing characterization on the module level, cell level, and finally the materials level. The observed performance losses from the module- and cell-level characterization can be correlated with materials properties to find out the root cause of degradation. We recommend an initial nondestructive characterization suite, including module- and cell-level current-voltage ( I--V ), Suns-V OC , photoluminescence and electroluminescence imaging, quantum efficiency, ultraviolet fluorescence imaging, and thermal infrared imaging. Samples are then extracted from particularly degraded regions of the module and prepared for materials characterization techniques, such as top-down and cross-sectional scanning electron microscopy, energy-dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, secondary ion mass spectrometry, Raman spectroscopy, and transmission electron microscopy, allowing a deeper look into the mechanism behind the metallization degradation. This article serves as an instructional review to introduce the different multiscale characterization methods and how they can be effectively applied to perform PV degradation studies. Furthermore, we also share some of our examples and discuss the strengths, limitations, and best practices for each of the characterization techniques.

14 SOLAR ENERGY↗

Enhanced Component Performance Study: Turbine-Driven Pumps 1998–2018

This report presents an enhanced performance evaluation of turbine-driven pumps (TDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2018 as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The TDP failure modes considered are failure to start (FTS), failure to run less than or equal to one hour (FTR≤1H), failure to run more than one hour (FTR>1H), and normally running systems FTS and failure to run (FTR). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. A highly statistically significant decreasing trend was identified in the standby TDP unavailability estimates.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗