Catalyst metal-ligand design for rapid, selective, and solventless depolymerization of Nylon-6 plastics
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Antibiotic use can lead to the expansion of multi-drug-resistant pathobionts within the gut microbiome that can cause life-threatening infections. Selective alternatives to conventional antibiotics are in dire need. Here, in this work, we describe a Klebsiella PhageBank for the tailored design of bacteriophage cocktails to treat multi-drug-resistant Klebsiella pneumoniae. Using a transposon library in carbapenem-resistant K. pneumoniae, we identify host factors required for phage infection in major Klebsiella phage families. Leveraging the diversity of the PhageBank, we formulate phage combinations that eliminate K. pneumoniae with minimal phage resistance. Optimized cocktails selectively suppress the burden of K. pneumoniae in the mouse gut and drive the loss of key virulence factors that act as phage receptors. Phage-mediated diversification of bacterial populations in the gut leads to co-evolution of phage variants with higher virulence and broader host range. Altogether, the Klebsiella PhageBank charts a roadmap for phage therapy against a critical multidrug-resistant human pathogen.
Not Available
Not provided.
Not Available
Not Available
Not Available
Not Available
Not provided.
Estimates of potential flood inundation areas and depths are critical to informing the preparedness, response, and investment decisions of many government agencies and private sector organizations, especially under a changing climate. The standard modeling approaches, however, are often either computationally intensive or constrained in their accuracy or applicability. A novel, rivulet-based, 2D model of pluvial flooding is described in this article that is 10,000 to 10 million times less computationally complex than the full solution of the shallow water equations, yet achieves inundation area hit rates of between 0.8 and 0.9 and relative absolute mean errors of 10%-20% across a wide range of flow depths. This combination of accuracy and efficiency will enable real-time depth estimates during flood events, detailed sensitivity analyses, and the generation of large ensembles to support broad uncertainty analyses.
Current research octane number (RON) and motor octane number (MON) gasoline performance characterization techniques use dated, complex engine testing methodology and limit researchers’ ability to easily characterize small volumes of experimental fuels. A novel methodology is presented that correlates measured ignition delay (ID) time to RON in an Advanced Fuel Ignition Delay Analyzer (AFIDA) constant-volume combustion chamber device at a single pressure/temperature condition, with an r2 of 0.99 and standard error (SE) of 1.0. The correlation of the slope of the ID time between two additional temperature points to octane sensitivity (S) produces an r2 of 0.97 and SE of 0.69; however, fuels with S>12 are indistinguishable. These results are based on methodology calibration using 31 primary and toluene reference fuels containing 0%-40% ethanol with RON values ranging from 85 to 113. Validation of these methods using a 102-sample fuel matrix spanning an array of base fuels and additive chemistry designed to test the robust applicability of the method, along with pump gasoline and high-octane surrogate blend samples, demonstrates an r2 of 0.94 and SE of 1.3 for the RON correlation over all samples, whereas the equivalent S correlation produces an r2 of 0.78 and SE of 1.2 by excluding two additives, 3-pentanone and diisobutylene, which displayed poor S correlation results. This novel AFIDA analysis method can be performed in 1 h and with 40 mL of fuel, offering significant improvements in time and volume requirements over traditional techniques.
Hydrogen (H 2 ) crossover in proton exchange membrane water electrolyzers refers to the process by which hydrogen produced at the cathode traverses the membrane and mixes with the oxygen produced at the anode. This phenomenon reduces efficiency and may pose flammability hazards. In this work we present a method for quantifying the H 2 content of the anode exhaust gas using a gas chromatograph that is capable of sampling data every 2 min. Subsequent theory is presented to calculate the crossover flux, overall H 2 efficiency, and H 2 energy requirements. Results the effects of membrane thickness using Nafion TM N117 (178 um) and Nafion TM NR212 (51 um) membranes. Furthermore, it was found that thinner membranes lead to improved VI performance but exhibit higher crossover rates. Despite their increased crossover, leading to decreased hydrogen efficiency, the calculated required energy for NR212 membrane-electrode assemblies (MEAs) was significantly lower than that of N117 MEAs.