Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Noise variance analysis using a flat panel x-ray detector: A method for additive noise assessment with application to breast CT applications

Purpose: A simplified linear model approach was proposed to accurately model the response of a flat panel detector used for breast CT (bCT). Methods: Individual detector pixel mean and variance were measured from bCT projection images acquired both in air and with a polyethylene cylinder, with the detector operating in both fixed low gain and dynamic gain mode. Once the coefficients of the linear model are determined, the fractional additive noise can be used as a quantitative metric to evaluate the system's efficiency in utilizing x-ray photons, including the performance of different gain modes of the detector. Results: Fractional additive noise increases as the object thickness increases or as the radiation dose to the detector decreases. For bCT scan techniques on the UC Davis prototype scanner (80 kVp, 500 views total, 30 frames/s), in the low gain mode, additive noise contributes 21% of the total pixel noise variance for a 10 cm object and 44% for a 17 cm object. With the dynamic gain mode, additive noise only represents approximately 2.6% of the total pixel noise variance for a 10 cm object and 7.3% for a 17 cm object. Conclusions: The existence of the signal-independent additive noise is the primary cause for a quadratic relationship between bCT noise variance and the inverse of radiation dose at the detector. With the knowledge of the additive noise contribution to experimentally acquired images, system modifications can be made to reduce the impact of additive noise and improve the quantum noise efficiency of the bCT system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-F-CAMPUS-J-05: Effect of Uncorrelated Noise Texture On Computed Tomography Quantitative Image Features

Purpose: To investigate the relationship between quantitative image features (i.e. radiomics) and statistical fluctuations (i.e. electronic noise) in clinical Computed Tomography (CT) using the standardized American College of Radiology (ACR) CT accreditation phantom and patient images. Methods: Three levels of uncorrelated Gaussian noise were added to CT images of phantom and patients (20) acquired in static mode and respiratory tracking mode. We calculated the noise-power spectrum (NPS) of the original CT images of the phantom, and of the phantom images with added Gaussian noise with means of 50, 80, and 120 HU. Concurrently, on patient images (original and noise-added images), image features were calculated: 14 shape, 19 intensity (1st order statistics from intensity volume histograms), 18 GLCM features (2nd order statistics from grey level co-occurrence matrices) and 11 RLM features (2nd order statistics from run-length matrices). These features provide the underlying structural information of the images. GLCM (size 128x128) was calculated with a step size of 1 voxel in 13 directions and averaged. RLM feature calculation was performed in 13 directions with grey levels binning into 128 levels. Results: Adding the electronic noise to the images modified the quality of the NPS, shifting the noise from mostly correlated to mostly uncorrelated voxels. The dramatic increase in noise texture did not affect image structure/contours significantly for patient images. However, it did affect the image features and textures significantly as demonstrated by GLCM differences. Conclusion: Image features are sensitive to acquisition factors (simulated by adding uncorrelated Gaussian noise). We speculate that image features will be more difficult to detect in the presence of electronic noise (an uncorrelated noise contributor) or, for that matter, any other highly correlated image noise. This work focuses on the effect of electronic, uncorrelated, noise and future work shall examine the influence of changes in quantum noise on the features. J. Oliver was supported by NSF FGLSAMP BD award HRD #1139850 and the McKnight Doctoral Fellowship.

60 APPLIED LIFE SCIENCES↗

Dislocation‐Induced Structural and Luminescence Degradation in InAs Quantum Dot Emitters on Silicon

This study probes the extent to which dislocations reduce carrier lifetimes and alter growth morphology and luminescence in InAs quantum dots (QD) grown on silicon. These heterostructures are key ingredients to achieving a highly reliable monolithically integrated light source on silicon necessary for photonic-integrated circuits. Around 20%–30% shorter carrier lifetimes are found at spatially resolved individual dislocations at room temperature using time-resolved cathodoluminescence spectroscopy, highlighting the strong nonradiative impact of dislocations even against the three-dimensional confinement of QDs. Beyond these direct effects of increased nonradiative recombination, it is found that misfit dislocations in the defect filter layers employed during III–V/Si growth alter the QD growth environment to induce a crosshatch-like variation in QD emission color and intensity when the filter layer is positioned sufficiently close to the QD emitter layer. Sessile threading dislocations generate even more egregious hillock defects that also reduce emission intensities by altering layer thicknesses, as measured by transmission electron microscopy and atom probe tomography. This work presents a more complete picture of the impacts of dislocations relevant to the development of light sources for scalable silicon photonic integrated circuits.

36 MATERIALS SCIENCE↗

Cryogenic Correlative Single‐Particle Photoluminescence Spectroscopy and Electron Tomography for Investigation of Nanomaterials

Abstract Cryogenic single‐particle photoluminescence (PL) spectroscopy has been used with great success to directly observe the heterogeneous photophysical states present in a population of luminescent particles. Cryogenic electron tomography provides complementary nanometer scale structural information to PL spectroscopy, but the two techniques have not been correlated due to technical challenges. Here, we present a method for correlating single‐particle information from these two powerful microscopy modalities. We simultaneously observe PL brightness, emission spectrum, and in‐plane excitation dipole orientation of CdSSe/ZnS quantum dots suspended in vitreous ice. Stable and fluctuating emitters were observed, as well as a surprising splitting of the PL spectrum into two bands with an average energy separation of 80 meV. In some cases, the onset of the splitting corresponded to changes in the in‐plane excitation dipole orientation. These dynamics were assigned to structures of individual quantum dots and the excitation dipoles were visualized in the context of structural features.

Dahlberg, Peter D.↗

Transducer selection and application in magnetoacoustic tomography with magnetic induction

As an acoustic receiver, transducer plays a vital role in signal acquisition and image reconstruction for magnetoacoustic tomography with magnetic induction (MAT-MI). In order to optimize signal acquisition, the expressions of acoustic pressure detection and waveform collection are theoretically studied based on the radiation theory of acoustic dipole and the reception pattern of transducer. Pressure distributions are simulated for a cylindrical phantom model using a planar piston transducer with different radii and bandwidths. The proposed theory is also verified by the experimental measurements of acoustic waveform detection for an aluminum foil cylinder. It is proved that acoustic pressure with sharp and clear boundary peaks can be detected by the large-radius transducer with wide bandwidth, reflecting the differential of the induced Lorentz force accurately, which is helpful for precise conductivity reconstruction. To detect acoustic pressure with acceptable pressure amplitude, peak pressure ratio, amplitude ratio, and improved signal to noise ratio, the scanning radius of 5–10 times the radius of the object should be selected to improve the accuracy of image reconstruction. This study provides a theoretical and experimental basis for transducer selection and application in MAT-MI to obtain reconstructed images with improved resolution and definition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical tomographic reconstruction of ion beam induced refractive index changes in silica

Refractive index changes induced by ion beam implantation can be used to produce photonic devices such as waveguides. Here, we relate the measured three-dimensional changes in refractive index produced by ion beam implantation to modeling of the implantation process. We use a quantitative phase microscopic method in conjunction with a tomographic reconstruction process to determine the change in the refractive index distribution within a silica optical fiber that has been selectively implanted with 2.4 MeV H{sup +} ions. The index profile is compared with numerical simulations of the ion vacancy and ionization using the stopping range of ions in matter program.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High spatiotemporal resolution measurement of regional lung air volumes from 2D phase contrast x-ray images

Purpose: Described herein is a new technique for measuring regional lung air volumes from two-dimensional propagation-based phase contrast x-ray (PBI) images at very high spatial and temporal resolution. Phase contrast dramatically increases lung visibility and the outlined volumetric reconstruction technique quantifies dynamic changes in respiratory function. These methods can be used for assessing pulmonary disease and injury and for optimizing mechanical ventilation techniques for preterm infants using animal models. Methods: The volumetric reconstruction combines the algorithms of temporal subtraction and single image phase retrieval (SIPR) to isolate the image of the lungs from the thoracic cage in order to measure regional lung air volumes. The SIPR algorithm was used to recover the change in projected thickness of the lungs on a pixel-by-pixel basis (pixel dimensions {approx}16.2 {mu}m). The technique has been validated using numerical simulation and compared results of measuring regional lung air volumes with and without the use of temporal subtraction for removing the thoracic cage. To test this approach, a series of PBI images of newborn rabbit pups mechanically ventilated at different frequencies was employed. Results: Regional lung air volumes measured from PBI images of newborn rabbit pups showed on average an improvement of at least 20% in 16% of pixels within the lungs in comparison to that measured without the use of temporal subtraction. The majority of pixels that showed an improvement was found to be in regions occupied by bone. Applying the volumetric technique to sequences of PBI images of newborn rabbit pups, it is shown that lung aeration at birth can be highly heterogeneous. Conclusions: This paper presents an image segmentation technique based on temporal subtraction that has successfully been used to isolate the lungs from PBI chest images, allowing the change in lung air volume to be measured over regions as small as the pixel size. Using this technique, it is possible to measure changes in regional lung volume at high spatial and temporal resolution during breathing at much lower x-ray dose than would be required using computed tomography.

60 APPLIED LIFE SCIENCES↗

Method of imaging the electrical conductivity distribution of a subsurface

A method of imaging electrical conductivity distribution of a subsurface containing metallic structures with known locations and dimensions is disclosed. Current is injected into the subsurface to measure electrical potentials using multiple sets of electrodes, thus generating electrical resistivity tomography measurements. A numeric code is applied to simulate the measured potentials in the presence of the metallic structures. An inversion code is applied that utilizes the electrical resistivity tomography measurements and the simulated measured potentials to image the subsurface electrical conductivity distribution and remove effects of the subsurface metallic structures with known locations and dimensions.

36 MATERIALS SCIENCE↗

Fielding of a time-resolved tomographic diagnostic

A diagnostic instrument has been developed for the acquisition of high-speed time-resolved images at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed in order to create time histories of the electron beam. Four discrete optical subsystems view Cerenkov light generated at an X-ray target inside of a vacuum envelope. Each system employs cylindrical optics to image light in one direction and collapse light in the orthogonal direction. Each of the four systems images and collapses in unique axes, thereby capturing unique information. Light along the imaging axis is relayed via optical fiber to streak cameras. A computer is used to reconstruct the original image from the four optically collapsed images. Due to DARHT’s adverse environment, the instrument can be operated remotely to adjust optical parameters and contains a subsystem for remote calibration. The instrument was deployed and calibrated, and has been used to capture and reconstruct images. Matters of alignment, calibration, control, resolution, adverse conditions and maintenance will be discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Milky Way Tomography IV: Dissecting Dust

We use SDSS photometry of 73 million stars to simultaneously obtain best-fit main-sequence stellar energy distribution (SED) and amount of dust extinction along the line of sight towards each star. Using a subsample of 23 million stars with 2MASS photometry, whose addition enables more robust results, we show that SDSS photometry alone is sufficient to break degeneracies between intrinsic stellar color and dust amount when the shape of extinction curve is fixed. When using both SDSS and 2MASS photometry, the ratio of the total to selective absorption, R{sub V}, can be determined with an uncertainty of about 0.1 for most stars in high-extinction regions. These fits enable detailed studies of the dust properties and its spatial distribution, and of the stellar spatial distribution at low Galactic latitudes (|b| < 30{sup o}). Our results are in good agreement with the extinction normalization given by the Schlegel et al. (1998, SFD) dust maps at high northern Galactic latitudes, but indicate that the SFD extinction map appears to be consistently overestimated by about 20% in the southern sky, in agreement with recent study by Schlafly et al. (2010). The constraints on the shape of the dust extinction curve across the SDSS and 2MASS bandpasses disfavor the reddening law of O'Donnell (1994), but support the models by Fitzpatrick (1999) and Cardelli et al. (1989). For the latter, we find a ratio of the total to selective absorption to be R{sub V} = 3.0 {+-} 0.1(random) {+-} 0.1 (systematic) over most of the high-latitude sky. At low Galactic latitudes (|b| < 5{sup o}), we demonstrate that the SFD map cannot be reliably used to correct for extinction because most stars are embedded in dust, rather than behind it, as is the case at high Galactic latitudes. We analyze three-dimensional maps of the best-fit R{sub V} and find that R{sub V} = 3.1 cannot be ruled out in any of the ten SEGUE stripes at a precision level of {approx} 0.1 - 0.2. Our best estimate for the intrinsic scatter of R{sub V} in the regions probed by SEGUE stripes is {approx} 0.2. We introduce a method for efficient selection of candidate red giant stars in the disk, dubbed 'dusty parallax relation', which utilizes a correlation between distance and the extinction along the line of sight. We make these best-fit parameters, as well as all the input SDSS and 2MASS data, publicly available in a user-friendly format. These data can be used for studies of stellar number density distribution, the distribution of dust properties, for selecting sources whose SED differs from SEDs for high-latitude main sequence stars, and for estimating distances to dust clouds and, in turn, to molecular gas clouds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microwave-driven coherent operation of a semiconductor quantum dot charge qubit

An intuitive realization of a qubit is an electron charge at two well-defined positions of a double quantum dot. The qubit is simple and has the potential for high-speed operation because of its strong coupling to electric fields. But, charge noise also couples strongly to this qubit, resulting in rapid dephasing at all but one special operating point called the ‘sweet spot’. In previous studies d.c. voltage pulses have been used to manipulate semiconductor charge qubits but did not achieve high-fidelity control, because d.c. gating requires excursions away from the sweet spot. Here, by using resonant a.c. microwave driving we achieve fast (greater than gigahertz) and universal single qubit rotations of a semiconductor charge qubit. The Z-axis rotations of the qubit are well protected at the sweet spot, and we demonstrate the same protection for rotations about arbitrary axes in the X–Y plane of the qubit Bloch sphere. We characterize the qubit operation using two tomographic approaches: standard process tomography and gate set tomography. Moreover, both methods consistently yield process fidelities greater than 86% with respect to a universal set of unitary single-qubit operations.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Atom probe tomography characterisation of a laser diode structure grown by molecular beam epitaxy

Atom probe tomography (APT) has been used to achieve three-dimensional characterization of a III-nitride laser diode (LD) structure grown by molecular beam epitaxy (MBE). Four APT data sets have been obtained, with fields of view up to 400 nm in depth and 120 nm in diameter. These data sets contain material from the InGaN quantum well (QW) active region, as well as the surrounding p- and n-doped waveguide and cladding layers, enabling comprehensive study of the structure and composition of the LD structure. Two regions of the same sample, with different average indium contents (18% and 16%) in the QW region, were studied. The APT data are shown to provide easy access to the p-type dopant levels, and the composition of a thin AlGaN barrier layer. Next, the distribution of indium within the InGaN QW was analyzed, to assess any possible inhomogeneity of the distribution of indium (''indium clustering''). No evidence for a statistically significant deviation from a random distribution was found, indicating that these MBE-grown InGaN QWs do not require indium clusters for carrier localization. However, the APT data show steps in the QW interfaces, leading to well-width fluctuations, which may act to localize carriers. Additionally, the unexpected presence of a small amount (x = 0.005) of indium in a layer grown intentionally as GaN was revealed. Finally, the same statistical method applied to the QW was used to show that the indium distribution within a thick InGaN waveguide layer in the n-doped region did not show any deviation from randomness.

36 MATERIALS SCIENCE↗

Laser ion source with solenoid field

Pulse length extension of highly charged ion beam generated from a laser ion source is experimentally demonstrated. In this study, the laser ion source (LIS) has been recognized as one of the most powerful heavy ion source. However, it was difficult to provide long pulse beams. By applying a solenoid field (90 mT, 1 m) at plasma drifting section, a pulse length of carbon ion beam reached 3.2 μs which was 4.4 times longer than the width from a conventional LIS. The particle number of carbon ions accelerated by a radio frequency quadrupole linear accelerator was 1.2 × 10 11 , which was provided by a single 1 J Nd-YAG laser shot. A laser ion source with solenoid field could be used in a next generation heavy ion accelerator.

43 PARTICLE ACCELERATORS↗

Generation and characterization of ultrabroadband polarization–frequency hyperentangled photons

We generate ultrabroadband photon pairs entangled in both polarization and frequency bins through an all-waveguided Sagnac source covering the entire optical C- and L-bands (1530–1625 nm). We perform comprehensive characterization of high-fidelity states in multiple dense wavelength-division multiplexed channels, achieving full tomography of effective four-qubit systems. Additionally, leveraging the inherent high dimensionality of frequency encoding and our electro-optic measurement approach, we demonstrate the scalability of our system to higher dimensions, reconstructing states in a 36-dimensional Hilbert space consisting of two polarization qubits and two frequency-bin qutrits. Our findings hold potential significance for quantum networking, particularly dense coding and entanglement distillation in wavelength-multiplexed quantum networks.

42 ENGINEERING↗

WE-G-204-04: Focal Spot Deblurring For High Resolution Amorphous Selenium (aSe) Complementary Metal Oxide Semiconductor (CMOS) X-Ray Detector

Purpose: CMOS-based aSe detectors compared to CsI-TFT-based flat panels have the advantages of higher spatial sampling due to smaller pixel size and decreased blurring characteristic of direct rather than indirect detection. For systems with such detectors, the limiting factor degrading image resolution then becomes the focal-spot geometric unsharpness. This effect can seriously limit the use of such detectors in areas such as cone beam computed tomography, clinical fluoroscopy and angiography. In this work a technique to remove the effect of focal-spot blur is presented for a simulated aSe detector. Method: To simulate images from an aSe detector affected with focal-spot blur, first a set of high-resolution images of a stent (FRED from Microvention, Inc.) were acquired using a 75µm pixel size Dexela-Perkin-Elmer detector and averaged to reduce quantum noise. Then the averaged image was blurred with a known Gaussian blur at two different magnifications to simulate an idealized focal spot. The blurred images were then deconvolved with a set of different Gaussian blurs to remove the effect of focal-spot blurring using a threshold-based, inverse-filtering method. Results: The blur was removed by deconvolving the images using a set of Gaussian functions for both magnifications. Selecting the correct function resulted in an image close to the original; however, selection of too wide a function would cause severe artifacts. Conclusion: Experimentally, focal-spot blur at different magnifications can be measured using a pin hole with a high resolution detector. This spread function can be used to deblur the input images that are acquired at corresponding magnifications to correct for the focal spot blur. For CBCT applications, the magnification of specific objects can be obtained using initial reconstructions then corrected for focal-spot blurring to improve resolution. Similarly, if object magnification can be determined such correction may be applied in fluoroscopy and angiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identifying Decoherence Mechanisms in Superconducting Qubits through Advanced Materials Characterization

Although superconducting qubits have emerged as a leading technology platform for quantum computing through large improvements in device coherence times and gate fidelity in recent years, the presence of defects and impurities at the interfaces and surfaces in the constituent materials continue to limit performance and serve as a critical barrier in achieving scalable quantum systems. Understanding and eliminating these sources of quantum decoherence in superconducting qubit devices requires dedicated studies aimed at establishing robust structure-property relationships that will enable researchers to target and eliminate defects strategically. As part of the Superconducting Materials and Systems (SQMS) center, we have extensively employed state-of-the-art materials characterization techniques, including scanning/transmission electron microscopy, secondary ion mass spectrometry, atom probe tomography, x-ray diffraction, and x-ray photoelectron spectroscopy in conjunction with device measurements to elucidate such relationships. In this talk, I will discuss some of our recent findings, including linking atomic defects to microwave loss in surface oxides, linking impurities in the Josephson Junction to qubit parameters, and linking low temperature precipitates to device performance. By applying these insights, we have been able to strategically develop and implement mitigation strategies for reliable fabrication of high coherence superconducting qubits.

Murthy, A. [Fermilab] (ORCID:0000000176776866)↗

Identifying Decoherence Mechanisms in Superconducting Qubits through Advanced Materials Characterization

Although superconducting qubits have emerged as a leading technology platform for quantum computing through large improvements in device coherence times and gate fidelity in recent years, the presence of defects and impurities at the interfaces and surfaces in the constituent materials continue to limit performance and serve as a critical barrier in achieving scalable quantum systems. Understanding and eliminating these sources of quantum decoherence in superconducting qubit devices requires dedicated studies aimed at establishing robust structure-property relationships that will enable researchers to target and eliminate defects strategically. As part of the Superconducting Materials and Systems (SQMS) center, we have extensively employed state-of-the-art materials characterization techniques, including scanning/transmission electron microscopy, secondary ion mass spectrometry, atom probe tomography, x-ray diffraction, and x-ray photoelectron spectroscopy in conjunction with device measurements to elucidate such relationships. In this talk, I will discuss some of our recent findings, including linking atomic defects to microwave loss in surface oxides, linking impurities in the Josephson Junction to qubit parameters, and linking low temperature precipitates to device performance. By applying these insights, we have been able to strategically develop and implement mitigation strategies for reliable fabrication of high coherence superconducting qubits.

Murthy, A. [Fermilab] (ORCID:0000000176776866)↗

In-situ observation of non-hemispherical tip shape formation during laser-assisted atom probe tomography

It is shown by SEM imaging of the tip and by observing the emission pattern of the evaporated atoms that laser assisted evaporation in an atom probe can lead to nonhemispherical tip shapes and time-dependent nonuniform emission. We have investigated this nonuniformity by observing the change in field of view when using laser wavelengths of 515 nm and 343 nm on silicon. The change is monitored in situ by 0.5 nm thick silicon oxide. We demonstrate that the field of view can easily be changed by more than 10 nm and that the apparent oxide layer thickness can deviate substantially from its correct value. The dependence of the tip shape deformations and the reconstruction artifacts on the laser wavelength are explained through simulations of the laser-tip interaction and nonhomogeneous heating effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗