Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

OPAD 1991

The Optical Plume Anomaly Detection Program, an experimental study in the attempt to create a rocket engine health monitor based on detection and possible quantification of anomalous atomic and molecular species in the exhaust plume, has been in existence for several years. The instruments developed to monitor the exhaust plumes are presented. Two optical instruments are employed: the polychromator and the spectrometer. The polychromator is a 16 channel spectroradiometer having independent channels individually adjustable for center wavelength and pass bandwidth. Those values may be mechanically reset, with the aid of certain lab equipment. The spectrometer is a multichannel spectral analyzer having two 2048 element linear photodiode arrays at the exit plane of the dispersing instrument, which, like the 16 channel device, is a 1/2 meter grating spectrograph. These instruments are equipped with ultraviolet grade multifiber optical input cables, allowing the instruments to be placed in a benign environment. Telescopes mounted on the test stand observe the plume keeping the shock structure in view. The data acquisition and control system consist of four 80386-33 MHz computers: two at the test stand for instrument control and data preconditioning, and two in the test support building providing data archiving, display, and system control. Further descriptions of the instrumentation are provided.

Powers, W. T.↗

Structural dynamics: Probabilistic structural analysis methods. Program overview

A brief description is provided of the fundamental aspects of a quantification process. Progress since the last structural durability conference in 1989 is summarized. The methodology to date and that to be developed during the life of the program is presented. The uncertain factors are presented. The approach is outlined that is required to achieve component and/or system certification in the shortest possible time for affordable reliability risk. Two new elements appear in a block diagram: (1) uncertainties in human factor, and (2) uncertainties in the computer code. Research to quantify the uncertainties in the human factor was initiated and is discussed.

Chamis, Christos C.↗

OPAD through 1991 - Status report no. 2

The Optical Plume Anomaly Detection (OPAD) experimental program has attempted to develop a rocket engine health monitor for the detection, and if possible the quantification, of anomalous atomic and molecular species in exhaust plumes. The test program has formulated instrument designs allowing both wide spectral range and high spectral resolution. Attention is presently given to OPAD data collected for the SSME at NASA-Marshall's technology test stand, with a view to spectral emissions at startup and variations in baseline plume emissions due to changes in rated power level.

Powers, W. T.↗

Three-dimensional temporal reconstruction and analysis of plume images

An experiment with two subsonic jets generating a cross-flow was conducted as part of a study of the structural features of temporal reconstruction of plume images. The flow field structure was made visible using a direct injection flow visualization technique. It is shown that image analysis and temporal three-dimensional visualization can provide new information on the vortical structural dynamics of multiple jets in a cross-flow. It is expected that future developments in image analysis, quantification and interpretation, and flow visualization of rocket engine plume images may provide a tool for correlating the engine diagnostic features by interpreting the evolution of the structures in the plume.

Dhawan, Atam P.↗

Absorption parameters of very dense molecular spectra for the HITRAN compilation

Cross sections for the heavy molecules CFC-11, CFC-12, CFC-13, CFC-14, CFC-22, CFC-113, CFC-114, CFC-115, CCl4, ClONO2, N2O5, HNO4, and HNO3 are included on the HITRAN 91 database. For many of these species, the cross sections vary by a factor of two between room temperature and temperatures near 210 K. The chemical importance of the heavy molecules, the quantitative accuracy of the HITRAN 91 cross sections, and the need for additional spectroscopic quantification are discussed.

Massie, S. T.↗

Laser absorption flow diagnostics for use in hypersonic ground-based and flight experiments

Consideration is given to laboratory ground-based scale systems for measuring OH and NO and diode laser systems for measuring O2 and H2O. Several diagnostic instruments which are currently being used in a scramjet combustor test rig of the Ames 16-inch shock tunnel are described. Data on mole fraction, temperature, density, pressure, and velocity is obtained using specific data reduction techniques. These measurements provide critical data for evaluation of the propulsion system performance which include mass capture for quantification of fuel equivalence ratio (O2), flow contamination and emission levels (NO), combustion progress (OH), and injector mixing and combustion efficiency (H2O).

Cavolowsky, John A.↗

Four dimensional reconstruction and analysis of plume images

Results of a time-history based three-dimensional reconstruction of cross-sectional images corresponding to a specific planar location of the jet structure are reported. The experimental set-up is described, and three-dimensional displays of time-history based reconstruction of the jet structure are presented. Future developments in image analysis, quantification and interpretation, and flow visualization of rocket engine plume images are expected to provide a tool for correlating engine diagnostic features with visible flow structures.

Dhawan, Atam P.↗

Doppler global velocimetry - The next generation?

A new measurement technique is being developed by NASA to measure off-surface flow fields. This method, Doppler global velocimetry, will allow quantification of complex three-dimensional flow fields at video camera rates. The entire flow field structure within a selected plane is measured simultaneously rather than by scanned, point-by-point measurements using conventional laser velocimetry. To assess the capability of this new technique, velocity measurements of the vortical flow field above a thin 75-degree delta wing were made in the NASA Langley Basic Aerodynamics Research Tunnel. The operation of the system is described along with the techniques developed to process the output images. The results are then compared with similar measurements obtained using a three component laser velocimeter.

Meyers, James F.↗

The interaction of high voltage systems with the environments of the moon and Mars

An evaluation is made of the consequences of the interaction of high-voltage spacecraft systems designed for use in orbit or on the lunar and Martian surfaces with such environmental components as electrically charged dust, low pressure atmospheres, ionospheric plasmas and neutral gas species, and chemically reactive species. An account is given of plausible means for obtaining the requisite data and developing priorities for the study of each of the identified interactions. Attention is given to the computational tools whose development is required for the simulation and quantification of risk factors for the various likely interactions.

Hillard, G. B.↗

Stratospheric aerosol and gas experiment III (SAGE III) aerosol and trace gas measurements for Earth Observing System (EOS)

The SAGE III instrument, the latest in a series of satellite-based instruments employing the self-calibrating solar occultation technique to monitor aerosols and trace gases in the atmosphere, and potential contributions to monitoring global change and other EOS objectives are described. Uses of these data are illustrated with SAGE I and II long-term ozone, aerosol, and water vapor data. The SAGE III instrument will improve the SAM II and SAGE data products with greater overall accuracy, and will provide the ability to extend these measurements over a greater height range. SAGE III will provide long-term self-calibrating global data sets from the midtroposphere to mesosphere, which will contribute greatly to the quantification and understanding of global change.

Mccormick, M. P.↗

Analysis of atmospheric trace constituents from high resolution infrared balloon-borne and ground-based solar absorption spectra

Results of ongoing studies of high-resolution solar absorption spectra aimed at the identification and quantification of trace constituents of importance in the chemistry of the stratosphere and upper troposphere are presented. An analysis of balloon-borne and ground-based spectra obtained at 0.0025/cm covering the 700-2200/cm interval is presented. The 0.0025/cm spectra, along with corresponding laboratory spectra, improves the spectral line parameters, and thus the accuracy of quantifying trace constituents. Results for COF2, F22, SF6, and other species are presented. The retrieval methods used for total column density and altitude distribution for both ground-based and balloon-borne spectra are also discussed.

Goldman, A.↗

The infeasibility of quantifying the reliability of life-critical real-time software

This paper affirms that the quantification of life-critical software reliability is infeasible using statistical methods, whether these methods are applied to standard software or fault-tolerant software. The classical methods of estimating reliability are shown to lead to exorbitant amounts of testing when applied to life-critical software. Reliability growth models are examined and also shown to be incapable of overcoming the need for excessive amounts of testing. The key assumption of software fault tolerance - separately programmed versions fail independently - is shown to be problematic. This assumption cannot be justified by experimentation in the ultrareliability region, and subjective arguments in its favor are not sufficiently strong to justify it as an axiom. Also, the implications of the recent multiversion software experiments support this affirmation.

Butler, Ricky W.↗

A comparison of two Shuttle launch and entry suits - Reach envelope, isokinetic strength, and treadmill tests

A quantification has been conducted of any existing differences between the performance, in operational conditions, of the Space Shuttle crew Launch Entry Suit (LES) and the new Advanced Crew Escape Suit (ACES). While LES is a partial-pressure suit, the ACES system which is being considered as a replacement for LES is a full-pressure suit. Three tests have been conducted with six subjects to ascertain the suits' reach envelope, strength, and treadmill performance. No significant operational differences were found between the two suit designs.

Schafer, Lauren E.↗

Tests characterizing bioprocessor hardware for analytical modeling

The tests outlined in this paper were used to characterize the hardware components of the Salad Machine, a small NASA-developed bioprocessor. The data from these tests are presented, and the methods by which this data can be integrated into system mathematical models are briefly discussed. The subsystems and physical processes discussed include the lighting system, the air loop (condensing heat exchanger and the blower), heat transfer to the surroundings, and leakage. Through this effort it was learned that in the development of a test protocol, care should be taken to order the tests such that environmental parameters, particularly humidity, require as few large adjustments as possible. Sensor calibration and installation take a substantial amount of time, which should be built into the test schedule. Two properties were particularly hard to quantify: the air flow rate and the energy from the lighting system entering into the growth volume. Flow rate can be measured using the appropriate device for the system configuration and airflow. Lighting system radiation level was measured using three methods. The results of these methods varied substantially, putting off conclusive quantification of this value.

Gustavino, S.↗

A computer-controlled apparatus for Seebeck inhomogeneity testing of sheathed thermocouples

Mineral-insulated metal-sheathed (MIMS) thermocouple assemblies are used throughout industry and research facilities as a method of temperature measurement where requirements for either harsh environmental conditions exist, or where rigidity of the measurement probe is required. Seebeck inhomogeneity is the abnormal variation of the Seebeck coefficient from point to point in a material. It is not disclosed in conventional calibration. A standardized method of measuring thermoelectric inhomogeneity along the thermocouple probe length is not available. Therefore, calibration for sheathed probes normally does not include testing of probe inhomogeneity. The measurement accuracy would be severely impacted if significant inhomogeneity and a temperature gradient were present in the same region of the probe. A computer-controlled system for determining inhomogeneities was designed, fabricated, and tested. This system provides an accurate method for the identification of the location of inhomogeneity along the length of a sheathed thermocouple and for the quantification of the inhomogeneity. This paper will discuss the apparatus and procedure used to perform these tests and will present data showing tests performed on sheathed thermocouple probes.

Burkett, Cecil G., Jr.↗

Sensitive Technique For Detecting Alignment Of Seed Laser

Frequency response near resonance measured. Improved technique for detection and quantification of alignment of injection-seeding laser with associated power-oscillator laser proposed. Particularly useful in indicating alignment at spectral purity greater than 98 percent because it becomes more sensitive as perfect alignment approached. In addition, implemented relatively easily, without turning on power-oscillator laser.

Barnes, Norman P.↗

Adaptive control of interface by temperature and interface profile feedback in transparent multi-zone crystal growth furnace

The objective of this research is to control the dynamics of multizone programmable crystal growth furnaces. Due to the inevitable heat exchange among different heating zones and the transient nature of the process, the dynamics of multizone furnaces is time varying, distributed, and therefore complex in nature. Electrical power to heating zones and the translational speed of the ampoule are employed as inputs to control the dynamics. Structural properties of the crystal is the ultimate aim of this adaptive control system. These properties can be monitored in different ways. Following an order of complexity, these may include: (1) on line measurement of the material optical properties such as the refractive index of crystal; (2) on line x-ray imaging of the interface topology; (3) on line optical quantification of the interface profile such as the determination of concavity or convexity of the interface shape; and (4) on line temperature measurement at points closest to the material such as measurements of the ampoule's outside and inside surface temperatures. The research performed makes use of the temperature and optical measurements, specified in (3) and (4) as the outputs of furnace dynamics. However, if the instrumentation is available, the proposed control methodology can be extended to the measurements listed in (1) and (2).

Batur, Celal↗

Magnetic resonance imaging after exposure to microgravity

A number of physiological changes were demonstrated in bone, muscle, and blood from exposure of humans and animals to microgravity. Determining mechanisms and the development of effective countermeasures for long-duration space missions is an important NASA goal. Historically, NASA has had to rely on tape measures, x-ray, and metabolic balance studies with collection of excreta and blood specimens to obtain this information. The development of magnetic resonance imaging (MRI) offers the possibility of greatly extending these early studies in ways not previously possible; MRI is also non-invasive and safe; i.e., no radiation exposure. MRI provides both superb anatomical images for volume measurements of individual structures and quantification of chemical/physical changes induced in the examined tissues. This investigation will apply MRI technology to measure muscle, intervertebral disc, and bone marrow changes resulting from exposure to microgravity.

Leblanc, Adrian↗