Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulsing frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Raman Lidar Profiles Best Estimate Value-Added Product Technical Report

The ARM Raman lidars are semi-autonomous ground-based systems that transmit at a wavelength of 355 nm with 300 mJ, ~5 ns pulses, and a pulse repetition frequency of 30Hz. Signals from the various detection channels are processed to produce time- and height-resolved estimates of several geophysical quantities, such as water vapor mixing ratio, relative humidity, aerosol scattering ratio, backscatter, optical depth, extinction, and depolarization ratio. Data processing is currently handled by a suite of six value-added product (VAP) processes. Collectively, these processes are known as the Raman Lidar Profiles VAP (RLPROF). The top-level best-estimate (BE) VAP process was introduced in order to bring together the most relevant information from the intermediate-level VAPs. As such, the BE process represents the final stage in data processing for the Raman lidar. Its principal function is to extract the primary variables from each of the intermediate-level VAPs, perform additional quality control, and combine all of this information into a single output file for the end-user. The focus of this document is to describe the processing performed by the BE VAP process.

54 ENVIRONMENTAL SCIENCES↗

Development and Deployment of a Compact Eye-Safe Scanning Differential absorption Lidar (DIAL) for Spatial Mapping of Carbon Dioxide for Monitoring/Verification/Accounting at Geologic Sequestration Sites

A scanning differential absorption lidar (DIAL) instrument for monitoring carbon dioxide has been developed. The laser transmitter uses two tunable discrete mode laser diodes (DMLD) operating in the continuous wave (cw) mode with one locked to the online absorption wavelength and the other operating at the offline wavelength. Two in-line fiber optic switches are used to switch between online and offline operation. After the fiber optic switch, an acousto- optic modulator (AOM) is used to generate a pulse train used to injection seed an erbium doped fiber amplifier (EDFA) to produce eye-safe laser pulses with maximum pulse energies of 66 {micro}J, a pulse repetition frequency of 15 kHz, and an operating wavelength of 1.571 {micro}m. The DIAL receiver uses a 28 cm diameter Schmidt-Cassegrain telescope to collect that backscattered light, which is then monitored using a photo-multiplier tube (PMT) module operating in the photon counting mode. The DIAL instrument has been operated from a laboratory environment on the campus of Montana State University, at the Zero Emission Research Technology (ZERT) field site located in the agricultural research area on the western end of the Montana State University campus, and at the Big Sky Carbon Sequestration Partnership site located in north-central Montana. DIAL data has been collected and profiles have been validated using a co-located Licor LI-820 Gas Analyzer point sensor.

47 OTHER INSTRUMENTATION↗

Raman Lidar MERGE Value-Added Product

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility Raman lidars (RLs) are semi-autonomous, land-based, laser remote sensing systems that provide height- and time-resolved measurements of water vapor mixing ratio, temperature, aerosol backscatter, extinction, and linear depolarization ratio from about 200 m to greater than 10 km AGL. These systems transmit at a wavelength of 355 nm with 300 mJ, ~5 ns pulses, and a pulse repetition frequency of 30 Hz. The receiver incorporates nine detection channels, including two water vapor channels at 408 nm, two nitrogen channels at 387 nm, three elastic channels, and two rotational Raman channels for temperature profiling at 354 and 353 nm. Figure 1 illustrates the layout of the ARM RL receiver system. Backscattered light from the atmosphere enters the telescope and is directed into the receiver system (i.e., aft optics). This signal is then split between a narrow-field-of-view radiometer (NFOV) path (blue) and a wide-field-of-view zenith radiometer (WFOV) path (red). The WFOV (2 mrad) path contains three channels (water vapor, nitrogen, and unpolarized elastic), and the NFOV (0.3 mrad) path contains six channels (water vapor, nitrogen, parallel and perpendicular elastic, and two rotational Raman). All nine detection channels use Electron Tubes 9954B photomultiplier tubes (PMTs). The signals from each of the nine PMTs are acquired using transient data recorders from Licel GbR (Berlin, Germany). The Licel data recorders provide simultaneous measurements of both analog photomultiplier current and photon counts at height resolution of 7.5 m and a time resolution of 10 s. The analog signal provides good linearity in the strong signal regime, but poor sensitivity at low signal levels. Conversely, the photo counting signal provides good sensitivity in the weak signal regime, but is strongly nonlinear at higher signal levels. The advantage in recording both signals is that they can be combined (or merged) into a single signal with improved dynamic range. The process of combining the analog and photon counting data has become known as “gluing” (Whiteman et al., 2006).

47 OTHER INSTRUMENTATION↗

Use of Fiber Optic Distributed Acoustic Sensing for Measuring Hydraulic Connectivity for Geothermal Applications

Advanced methods in reservoir characterization are required to effectively harness geothermal energy from fractured high-temperature, high-pressure crystalline rock. It is critical to determine sufficient fluid connection between injection and production wells to enhance sweep efficiency and optimize the lifetime of the reservoir. A technology is needed that can monitor hydraulic connectivity in real time at any depth in the reservoir, throughout the lifetime of the reservoir. GeoMechanics Technologies, in collaboration with California State University, Long Beach (CSULB) and Silixa LLC, working in cooperation with the Department of Energy, Small Business Innovation Research through DOE SBIR Grant No: DE-SC-0017744, conducted a Phase I research project to investigate the use of fiber optic Distributed Acoustic Sensing (DAS) to improve geothermal reservoir characterization. Fiber optic DAS technology uses inter-well pressure sensing in response to periodic injection to determine hydraulic connectivity in fractured geothermal reservoirs. Fiber optic technology is capable of withstanding high temperatures and pressures typical of geothermal reservoirs. This tool would provide nearly continuous pressure monitoring along the length of the wellbore, providing knowledge into hydraulic pathways even where perforations do not exist. Real-time hydraulic monitoring can be performed without interrupting normal field operations. Also, measurements can be obtained throughout the lifetime of the well, ideally accounting for any changes in operations or reservoir configurations or thermally induced changes in permeability. The objective of this research effort was to develop and document an innovative tool that can be used for geothermal reservoir characterization. GeoMechanics Technologies and partners investigated and documented the use of fiber optic DAS for measuring the hydromechanical response caused by fractures in a reservoir and how that correlates to reservoir connectivity. For this Phase I project, numerical simulations, laboratory testing, and a field demonstration were performed to further validate the effectiveness of DAS technology for detecting formation hydraulics. This report summarizes the project activities. The main significant findings are: 1. From the numerical simulations using conceptual models, it is concluded that a high permeability zone inside a reservoir shows a different strain pattern along vertical monitoring lines away from the injection, when inducing low frequency pressure pulses. 2. The order of magnitude of strain observed at a distance of 100 ft from the injection well ranged from nanostrain to microstrain. Such strains are detectable with DAS tools currently available to industry. 3. Laboratory experiments stressed the importance of cable design and layout in the field, making calibration on site necessary for each application individually. 4. Field comparison highlighted the operational conditions that play a role in adding noise to the DAS measurement, where temperature effects for this type of application are also considered as noise to the strain measurements. 5. The analyses conducted to date provide motivation for further research, development and application of this technology, combined with field testing.

15 GEOTHERMAL ENERGY↗

Titanate Capacitors for Power Electronics

Titanium alloys were synthesized and coated with oxide dielectric films using anodizing in electrolytic baths. They possess high specific energies based on high charge-densities and high breakdown-electric-fields. These were made into alloy ribbons by rapid solidification by vacuum-spin casting, then anodized to form homogeneous dielectric films that serve as the medium in which electric charges are stored with high specific energy density in electrolytic capacitors. The new energy-dense dielectrics were formed by anodizing homogeneous Ti-Zr-X anode alloys, where X is a combination of Hf, Nb, Mo, Be, and/or Si. Thus homogeneous, dense and essentially-defect-free oxide-glass films were formed, e.g., (Ti-Zr-Hf-Be)O 2 films with high specific energy with stability over a wide voltage range, up to over 300 Volt, at temperatures from cryogenic to over 100 degrees C. When packaged with oxidizing electrolyte the dielectric is self-repairing in the event that accidental defects spring up. This provides reliable high-energy and high power performance with little de-rating, i.e., high reliability and lifetime in pulsed or high-frequency operating conditions.

25 ENERGY STORAGE↗

Switch leakage mitigation through differential cancellation

High speed analog-to-digital converters (ADC), switched-capacitor delay elements, and pulsed radio frequency (RF) systems all require switches in the signal path operating at high switching speeds, providing low resistance when enabled, and providing high signal isolation when disabled. In semiconductor technologies such as CMOS, the enabled state resistance directly scales with the sizing of the switch device, where a larger width switch provides a lower enabled state resistance. As the device width is increased, so is the capacitance formed between the gate, drain, and source of the device.

42 ENGINEERING↗

Development of a 50 MW 30 GHz Gyroklystron Amplifier

DOE requires sources for testing of high gradient accelerator structures. A power of 50 MW is required at K and Ka band. The pulse length must be ~ 1 microsecond and the pulse repetition frequency at least 100 Hz. At least some applications may require phase stability not offered by a free running oscillator. CCR proposed to build a 50 MW 30 GHz gyrklystron amplifier. This approach would give the required phase stability. The frequency was at the second harmonic of the cycltron frequency and used the TE02 mode. This makes it possible to design a device without an inner conductor, and with a conventional (non-inverted) MIG. This minimizes cost and the risk due to mechanical alignment issues. A detailed design of the gyroklystron was produced. The design was based on simulations of the cavity(ies), electron gun, output coupler and output window. Two designs were produced. One was at the fundamental of the cyclotron frequency. Simulations predicted an output power of 72 MW with an efficiency of 48%. The other was at the second harmonic, producing 37 MW with an efficiency of 37%.

43 PARTICLE ACCELERATORS↗

Compact Gamma-ray Source Technology Development Study

This study focuses on the applicability of current accelerator and laser technologies to the construction of compact, narrow bandwidth, gamma-ray sources for DHS missions in illicit materials detection. It also identifies research and development areas in which advancement will directly benefit these light sources. In particular, we review the physics of Compton scattering based light sources and emphasize the source properties most important to Nuclear Resonance Fluorescence (NRF) applications of interest. The influences of laser and electron beam properties on the light source are examined in order to evaluate the utility of different technologies for this application. Applicable bulk and fiber-based laser systems and laser recirculation technologies are discussed and Radio Frequency (RF) Linear Accelerator (linac) technologies are examined to determine the optimal frequency and pulse formats achievable.

42 ENGINEERING↗

Remotely-actuated biomedical switch

Remotely-actuated biomedical switching circuit using transistors consumes no power in the off position and can be actuated by a single-frequency telemetry pulse to control implanted instrumentation. Silicon controlled rectifiers permit the circuit design which imposes zero drain on supply batteries when not in use.

Lee, R. D.↗

Electro-optical time marker for high-speed cameras

Electro-optical device converts high-frequency electrical pulses into permanent optical records on film. Accurate, well defined images are formed of electronic pulses having repetition rates greater than 10,000 pulses/sec and pulse widths of 20 microseconds or less. Small electronic switch drives a silicon carbide electroluminescent diode.

Copeland, J. T., Jr.↗

Event-sequence detector

Detector consists of matrix of storage elements which are activated by coincidence of failure-voltage pulses and clock pulses. Clock frequency used for event sequence detector can be selected to provide time resolution demanded by test at hand.

Hanna, M. F.↗

The 1969 solar occultation of the Crab Nebula pulsar.

Results of an occultation experiment carried out on June 14-15, 1969, when the Crab Nebula pulsar passed within 80 min of arc from the center of the sun. For a time interval of two months around this event comparisons are made of the reception times of pulses at frequencies of 111.5, 196.5, and 430 MHz for the purpose of determining the contribution of the solar corona to the integrated electron density along the total path length to the pulsar. For impact parameters between 5 and 12 solar radii the measured integrated densities are not incompatible with those that can be derived from a spherically symmetric Baumbach-Allen model. The systematic differences in density obtained at each observation frequency can be explained in terms of refraction effects.

Rankin, J. M.↗