Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “process tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

[18F]Tosyl fluoride as a versatile [18F]fluoride source for the preparation of 18F-labeled radiopharmaceuticals

Abstract Positron emission tomography (PET) is an in vivo imaging technology that utilizes positron-emitting radioisotope-labeled compounds as PET radiotracers that are commonly used in clinic and in various research areas, including oncology, cardiology, and neurology. Fluorine-18 is the most widely used PET-radionuclide and commonly produced by proton bombardment of 18 O-enriched water in a cyclotron. The [ 18 F]fluoride thus obtained generally requires processing by azeotropic drying in order to completely remove H 2 O before it can be used for nucleophilic radiofluorination. In general, the drying step is important in facilitating the radiofluorination reactions and the preparation of 18 F-labeled PET radiotracers. In this communication, we have demonstrated the feasibility of using [ 18 F]tosyl fluoride ([ 18 F]TsF) as a versatile [ 18 F]fluoride source for radiofluorination to bypass the azeotropic drying step, and we have developed a continuous flow solid-phase radiosynthesis strategy to generate [ 18 F]TsF in a form that is excellent for radiofluorination. [ 18 F]TsF shows high reactivity in radiofluorination and provides the features suitable for preparing PET radiotracers on a small scale and exploring novel radiolabeling technologies. Thus, using [ 18 F]TsF as a [ 18 F]fluoride source is a promising strategy that facilitates radiofluorination and provides a convenient and efficient solution for the preparation of 18 F-labeled radiopharmaceuticals that is well matched to the emerging trends in PET imaging technologies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation and Development of Phase Array Ultrasonic Testing (PAUT) System for Additively Manufactured Parts

This research focuses on the application of advanced ultrasonic testing techniques developed by The Phased Array Company (TPAC) for inspecting defects in additive manufacturing (AM) parts. Traditionally, X-ray computed tomography is the standard for inspecting AM components. Although, the long inspection and analysis time, along with relatively high cost make implementation difficult. Thus, an alternative nondestructive evaluation (NDE) approach is necessary to support quality assurance efforts within the field of AM. TPAC is recognized as a leader in ultrasonic testing innovation, deploying sophisticated algorithms such as Total Focusing Method (TFM) and Phased Wave Imaging (PWI) for ultrasonic data processing and interpretation. This work will explore how the TFM and PWI algorithms can assist defect detection within polymer AM parts. The AM field is seeking novel NDE methods to provide support within quality control and assurance efforts. Advanced ultrasonics inspection have the potential to fulfill this need.

99 GENERAL AND MISCELLANEOUS↗

Evaluation and Development of Phase Array Ultrasonic Testing (PAUT) System for Additively Manufactured Parts

This research focuses on the application of advanced ultrasonic testing techniques developed by The Phased Array Company (TPAC) for inspecting defects in additive manufacturing (AM) parts. Traditionally, X-ray computed tomography is the standard for inspecting AM components. Although, the long inspection and analysis time, along with relatively high cost make implementation difficult. Thus, an alternative nondestructive evaluation (NDE) approach is necessary to support quality assurance efforts within the field of AM. TPAC is recognized as a leader in ultrasonic testing innovation, deploying sophisticated algorithms such as Total Focusing Method (TFM) and Phased Wave Imaging (PWI) for ultrasonic data processing and interpretation. This work will explore how the TFM and PWI algorithms can assist defect detection within polymer AM parts. The AM field is seeking novel NDE methods to provide support within quality control and assurance efforts. Advanced ultrasonics inspection have the potential to fulfill this need.

36 MATERIALS SCIENCE↗

Sensitivity Analysis of Geometric Imperfection Sources in Honeycomb Cores on Flatwise Compression Behavior

Manufacturing aluminum honeycomb core material using the expansion process can lead to geometric imperfections in the cellular core structures. These imperfections arise due to irregularities introduced in the initial foil bonding, variations in foil thickness, and residual stresses from manufacturing processes. Such geometric imperfections include cell shape distortions, cell wall waviness, non-uniform cell wall thickness, and variability in the shape and height of the adhesive fillet. Imperfections in the cell walls negatively affect the transverse compression and shear strength, while also reducing the resistance to damage under impact loads. Previous work presented the identification and quantification of these manufactured imperfections using high resolution X-ray computed tomography (CT) scans of honeycomb cores in co-cured composite sandwich panels. The present paper presents a sensitivity analysis of individual components of the sources of geometric imperfections on the flatwise compression of aluminum honeycomb cores. The initial geometric imperfections in honeycomb cells are decomposed into three components, namely cell shape (cell edge length and cell internal angles) in-plane cell wall waviness, and out-of-plane waviness along the core thickness. A sensitivity analysis is conducted using finite element (FE) models of the decomposed imperfections to understand how each component affects compression failure.

aluminum honycomb↗

37-Day Microgravity Exposure in 16-Week Female C57BL/6J Mice is Associated with Weight Bearing Site-Specific Bone Loss

Exposure to space environment factors, including microgravity unloading and space radiation, is well-known to be associated with rapid bone loss in mammals, but significant questions remain about mechanistic aspects of this process. Specifically, bone loss may vary depending on many interacting factors including age and skeletal maturity, physical activity, social versus individual housing, and habitat configuration. Likewise cellular tissue loss mechanisms in space may include changes to mineral homeostasis by activation of bone degradation by osteoclasts, or inhibition of bone formation by osteoblasts, and be caused by microgravity mechanical unloading or increased space radiation. In this study we used microcomputed tomography to quantify bone loss in multiple skeletal sites of group housed mice either exposed to 37 days in space on ISS during the Rodent Research 1, (RR1), experiments using the NASA Rodent Habitat, (RH), versus ground controls in the same habitats or standard vivarium cages. Our results in space versus matched RH ground controls show significant cancellous and cortical bone loss in the femur and tibia, but not in vertebrae, indicating that only weight-bearing bones experience significant bone loss during spaceflight. This finding suggests that space radiation at the low levels found in low Earth Orbit may not be a significant contributing factor to bone loss in space. Interestingly while mice maintained in the RH maintained or gained bone relative to Basal controls, mice kept in standard vivarium cages for 37 days showed significant loss in weight bearing bones, not as acute, but comparable in magnitude to spaceflight effects. These results suggest the RH configuration versus vivarium cages, may allow for greater mechanical loading of weight bearing bones as mice climb internal habitat surfaces, promoting maintenance of bone regenerative health.

mouse↗

Tomo2Mesh: Fast Reconstruction and Visualization of Tomography Data in Mesh Format

Tomo2Mesh is an open-source project targeted towards real-time reconstruction, segmentation, and visualization of computed tomography (CT) data in mesh format. The CT reconstruction scheme is based on filtered back-projection of voxel subsets. The segmentation scheme uses a 3D convolutional neural network. To allow for fast, real-time reconstruction, voxel subsets are first identified by coarse reconstruction. The detail in specific regions of interest is improved through full reconstruction of voxel subsets in that region. Data structures are implemented to store and process voxel subsets. Finally, voxel data is labeled using connected components to detect disconnected regions such as voids whose morphological attributes (e.g., Feret diameter, principal axis orientation, local number density, size, etc.) can be measured also in real-time. Finally, a fast marching cubes implementation processes labeled voxel data into a triangular face mesh (vertices and faces) in .ply format for visualization in Paraview or other mesh visualization tools. The code provides a simple programming interface for detecting, classifying, and visualizing regions of interest based on morphology. For example, detected voids can be classified as round pores or extended cracks. Highly porous neighborhoods can be identified based on local number density. The mesh texture (or color) is assigned based these morphological attributes to allow smart visualization scenarios in real-time (e.g., show only long cracks). At the time of first release (July 2022), extraction of face mesh for visualization for raw CT data from a 2 megapixel camera would take between 1-5 minutes for most scenarios.

TEKAWADE, ANIKET↗

Soil carbon accrual and biopore formation across a plant diversity gradient

Plant diversity promotes soil organic carbon (SOC) gains through intricate changes in root-soil interactions and their subsequent influence on soil physical and biological processes. We assessed SOC and pore characteristics of soils under a range of switchgrass-based plant systems 12 years after their establishment. The systems represented a gradient of plant diversity with species richness ranging from 1 to 30 species. We focused on soil biopores as indicators of the legacy of root activity and explored biopore relationships with SOC accumulation. Biopores were measured using X-ray computed micro-tomography. Plant functional richness explained 29 % of bioporosity and 36 % of SOC variation, while bioporosity itself explained 36 % of the variation in SOC. The most diverse plant system (30 species) had the highest SOC, while long-term bare soil fallow and monoculture switchgrass had the lowest. Of particular note was a 2-species mixture of switchgrass (Panicum virgatum L.) and ryegrass (Elymus canadensis), which exhibited the highest bioporosity and achieved SOC levels comparable to those of the systems with 6 and 10 plant species, and were inferior only to the system with 30 species. We conclude that plant diversity may enhance SOC through biopore-mediated mechanisms and suggest a potential for identifying specific plant combinations that may be particularly efficient for fostering biopore formation and, subsequently, SOC sequestration.

Kim, Kyungmin [Seoul National Univ. (Korea, Republ↗

Pressure regimes and core formation in the accreting earth

Recent work suggests that a large degree of melting is required to segregate metal from silicates, suggesting a connection with the formation of magma oceans. At low pressures metallic liquids do not wet silicate minerals, preventing the metal from aggregating into large masses that can sink. At high pressures, above 25 GPa, the dihedral angles of grains in contact with oxygen-rich metallic liquids may be reduced enough to allow percolation of metal, but this has not been confirmed. Physical models of core formation and accretion may therefore involve the formation of magma oceans and the segregation of metal at both high and low pressures. Models of core formation involving different pressure regimes are discussed as well as chemical evidence bearing on the models. Available geophysical data is ambiguous. The nature of the 670 km boundary (chemical difference or strictly phase change) between the upper and lower mantle is in doubt. There is some evidence that plumes are derived from the lower mantle, and seismic tomography strongly indicates that penetration of subducting oceanic crust into the lower mantle, but the tomography data also indicates that the 670 km discontinuity is a significant barrier to general mantle convection. The presence of the D' layer at the base of the lower mantle could be a reaction zone between the mantle and core indicating core-mantle disequilibrium, or D' layer could be subducted material. The abundance of the siderophile elements in the mantle could provide clues to the importance of high pressure processes in Earth, but partition coefficients at high pressures are only beginning to be measured.

Newsom, H. E.↗

Examining phase separation and crystallization in glasses with X-ray nano-computed tomography

X-ray nano-computed tomography (nano-CT) is a powerful technique to characterize and visualize 3 dimensional (3D) phenomena in complex glasses at the nanoscale. This technique can offer a unique opportunity to explore the intricate morphology of multicomponent glass and glass-ceramic samples, due to its low X-ray energy and high spatial resolution (down to 50 nm). In the current demonstration paper, nano-CT provided insight into crystallization and phase separation, as well as a variety of other phenomena, including corrosion, fracture, and porosity. At scales ranging from 100 to 20 μm, the microstructures of phase separation in borosilicate, complex silicate, and chalcogenide glass compositions were examined. In addition, crystallites present in simulant nuclear waste glasses, volcanic glasses, and other related samples were explored. Nano-CT analysis can add to the understanding of (1) the formation processes, (2) distributions, interactions, and compositions of phases, and (3) the mechanisms, structures, and growth of crystallization and phase separation. Nano-CT offers wide potential in the field of glass science, especially when (1) common characterization methods are insufficient, (2) simple sample preparation is required, (3) 3D rendering is needed, or (4) compelling images of small, complex features are desired.

36 MATERIALS SCIENCE↗

X-Ray Computed Tomography Monitors Damage in Composites

The NASA Lewis Research Center recently codeveloped a state-of-the-art x-ray CT facility (designated SMS SMARTSCAN model 100-112 CITA by Scientific Measurement Systems, Inc., Austin, Texas). This multipurpose, modularized, digital x-ray facility includes an imaging system for digital radiography, CT, and computed laminography. The system consists of a 160-kV microfocus x-ray source, a solid-state charge-coupled device (CCD) area detector, a five-axis object-positioning subassembly, and a Sun SPARCstation-based computer system that controls data acquisition and image processing. The x-ray source provides a beam spot size down to 3 microns. The area detector system consists of a 50- by 50- by 3-mm-thick terbium-doped glass fiber-optic scintillation screen, a right-angle mirror, and a scientific-grade, digital CCD camera with a resolution of 1000 by 1018 pixels and 10-bit digitization at ambient cooling. The digital output is recorded with a high-speed, 16-bit frame grabber that allows data to be binned. The detector can be configured to provide a small field-of-view, approximately 45 by 45 mm in cross section, or a larger field-of-view, approximately 60 by 60 mm in cross section. Whenever the highest spatial resolution is desired, the small field-of-view is used, and for larger samples with some reduction in spatial resolution, the larger field-of-view is used.

Baaklini, George Y.↗

Extensive nanoprecipitate morphology transformation in a nanostructured ferritic alloy due to extreme thermomechanical processing

Nano-oxide precipitates in a modern nanostructured ferritic alloy were investigated after extreme thermomechanical processing into a thin-walled tube geometry. It was found that the morphology of the precipitates changed from spherical to rod-shaped, with some increasing to aspect ratios of up to 9, despite the precipitate volume fraction (0.3%) and number density (> 10 23 m -3 ) of precipitates remaining unchanged. High-resolution electron microscopy showed that the precipitates likely remained coherent with the Fe-matrix, while atom probe tomography confirmed that the precipitate compositions remained unaffected by the transformation. The morphological change was attributed to the shearable nature of the (Y,Ti,O)-rich precipitates, indicating they should be considered as “soft” obstacles to dislocation motion. The elongation was most pronounced in larger (>5 nm) precipitates, which may be caused by preferential dissolution of the smallest (1–3 nm) precipitates followed by the competition between re-precipitation and solute diffusion to larger precipitates during recovery heat treatments.

36 MATERIALS SCIENCE↗

Study of deeply virtual Compton scattering at the future electron-ion collider

This study presents the impact of future measurements of deeply virtual Compton scattering (DVCS) with the ePIC detector at the electron-ion collider (EIC), currently under construction at Brookhaven National Laboratory. The considered process is sensitive to generalized parton distributions (GPDs), the understanding of which is a cornerstone of the EIC physics program. Our study marks a milestone in the preparation of DVCS measurements at EIC and provides a reference point for future analyses. In addition to presenting distributions of basic kinematic variables obtained with the latest ePIC design and simulation software, we examine the impact of future measurements on the understanding of nucleon tomography and DVCS Compton form factors, which are directly linked to GPDs. We also assess the impact of radiative corrections and background contribution arising from exclusive π 0 production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microstructural heterogeneity of the buffer layer of TRISO nuclear fuel particles

Tristructural isotropic (TRISO) nuclear fuel particles contain a layered spherical shell designed to retain fission products; however, failure occurs in rare cases—commonly initiated in the porous pyrocarbon buffer layer. Achieving a comprehensive understanding of the buffer-initiated failure mechanisms requires detailed characterization of the buffer porosity and its heterogeneous distribution across multiple length scales. Here we performed FIB-SEM tomography across the buffer layer thickness (~100 µm) to produce 3D reconstructions of the buffer microstructure with 50 nm spatial resolution. We found an average overall porosity of ~14%, which does not solely account for the low density of the buffer (50% of the theoretical density). Additionally, the local porosity and its fluctuation increase from the kernel interface towards the inner pyrocarbon (IPyC) layer, which we attribute to the chemical vapor deposition process conditions during the TRISO particle fabrication. Detailed characterization of the porous microstructure—including analysis of the pore size, distribution, shape, and orientation—provides insight into the process-structure-property-performance relations of TRISO nuclear fuel particles and will inform multiscale models designed to predict the failure of TRISO particles under irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Visualization of conformational changes and membrane remodeling leading to genome delivery by viral class-II fusion machinery

Chikungunya virus (CHIKV) is a human pathogen that delivers its genome to the host cell cytoplasm through endocytic low pH-activated membrane fusion mediated by class-II fusion proteins. Though structures of prefusion, icosahedral CHIKV are available, structural characterization of virion interaction with membranes has been limited. Here, we have used cryo-electron tomography to visualize CHIKV’s complete membrane fusion pathway, identifying key intermediary glycoprotein conformations coupled to membrane remodeling events. Using sub-tomogram averaging, we elucidate features of the low pH-exposed virion, nucleocapsid and full-length E1-glycoprotein’s post-fusion structure. Contrary to class-I fusion systems, CHIKV achieves membrane apposition by protrusion of extended E1-glycoprotein homotrimers into the target membrane. The fusion process also features a large hemifusion diaphragm that transitions to a wide pore for intact nucleocapsid delivery. Our analyses provide comprehensive ultrastructural insights into the class-II virus fusion system function and direct mechanistic characterization of the fundamental process of protein-mediated membrane fusion.

59 BASIC BIOLOGICAL SCIENCES↗

Physics guided machine learning for multi-material decomposition of tissues from dual-energy CT scans of simulated breast models with calcifications

We introduce a physics guided data-driven method for image-based multi-material decomposition for dual-energy computed tomography (CT) scans. The method is demonstrated for CT scans of virtual human phantoms containing more than two types of tissues. The method is a physics-driven supervised learning technique. We take advantage of the mass attenuation coefficient of dense materials compared to that of muscle tissues to perform a preliminary extraction of the dense material from the images using unsupervised methods. We then perform supervised deep learning on the images processed by the extracted dense material to obtain the final multi-material tissue map. The method is demonstrated on simulated breast models with calcifications as the dense material placed amongst the muscle tissues. The physics-guided machine learning method accurately decomposes the various tissues from input images, achieving a normalized root-mean-squared error of 2.75%.

Gopalakrishnan Meena, Murali↗

Determination of the Three-Dimensional Morphology of ALH84001 and Biogenic MV-1 Magnetite: Comparison of Results from Electron Tomography and Classical Transmission Electron Microscopy

Dated at approximately 3.9 billion years of age, carbonate disks, found within fractures of the host rock of Martian meteorite ALH84001, have been interpreted as secondary minerals that formed at low temperature in an aqueous medium. Heterogeneously distributed within these disks are magnetite nanocrystals that are of Martian origin. Approximately one quarter of these magnetites have morphological and chemical similarities to magnetite particles produced by magnetotactic bacteria strain MV-1, which are ubiquitous in aquatic habitats on Earth. Moreover, these types of magnetite particles are not known or expected to be produced by abiotic means either through geological processes or synthetically in the laboratory. The remaining three quarters of the ALH84001 magnetites are likely products of multiple processes including, but not limited to, precipitation from a hydrothermal fluid, thermal decomposition of the carbonate matrix in which they are embedded, and extracellular formation by dissimilatory Fe-reducing bacteria. We have proposed that the origins of magnetites in ALH84001 can be best explained as the products of multiple processes, one of which is biological. Recently the three-dimensional (3-D) external morphology of the purported biogenic fraction of the ALH84001 magnetites has been the subject of considerable debate. We report here the 3-D geometry of biogenic magnetite crystals extracted from MV-1 and of those extracted from ALH84001 carbonate disks using a combination of high resolution classical and tomographic transmission electron microscopy (TEM). We focus on answering the following questions: (1) which technique provides adequate information to deduce the 3-D external crystal morphology?; and, (2) what is the precise 3-D geometry of the ALH84001 and MV-1 magnetites?

Thomas-Keprta, Kathie L.↗

Rapid macrovoid characterization in membranes prepared via nonsolvent-induced phase separation: A comparison between 2D and 3D techniques

Optimizing the performance of asymmetric membranes prepared via nonsolvent-induced phase separation (NIPS) requires a quantitative understanding of how processing variables influence membrane morphology. Presently, the most useful structural quantification techniques require 3D visualization of the membrane structure and are best suited for studies seeking detailed information on small datasets. This study proposes and validates a rapid and accurate technique for quantifying macroporosity (i.e., D m ), a simple descriptor of sublayer macrovoid content in asymmetric membranes D m . values measured from segmented cross-sectional imaging performed via X-ray computed tomography (XCT) and scanning electron microscopy (SEM) are presented and compared for three asymmetric membranes prepared from commercial polymers. Importantly, analyses of 3D XCT membrane reconstructions reveal that D m is described by a single, centralized mean, which demonstrates that macrovoid content is spatially homogenous. Thus, D m can be approximated from limited sampling of the 2D cross-sectional membrane structure via SEM. A proposed 2D SEM sampling method provides D m estimates within ±6% of corresponding 3D XCT values with 30 independent measurements for the three membranes. Further sensitivity is achieved using complementary descriptors such as macrovoid count density (i.e., C m ). This technique is thus a useful tool for characterizing macroporosity from a broad selection of membrane samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CryoDRGN-AI: neural ab initio reconstruction of challenging cryo-EM and cryo-ET datasets

Proteins and other biomolecules form dynamic macromolecular machines that are tightly orchestrated to move, bind, and perform chemistry. Cryo-electron microscopy (cryo-EM) and cryo-electron tomography (cryo-ET) can access the intrinsic heterogeneity of these complexes and are therefore key tools for understanding their function. However, 3D reconstruction of the collected imaging data presents a challenging computational problem, especially without any starting information, a setting termed ab initio reconstruction. Here, in this study, we introduce cryoDRGN-AI, a method leveraging an expressive neural representation and combining an exhaustive search strategy with gradient-based optimization to process challenging heterogeneous datasets. Using cryoDRGN-AI, we reveal new conformational states in large datasets, reconstruct previously unresolved motions from unfiltered datasets, and demonstrate ab initio reconstruction of biomolecular complexes from in situ data. With this expressive and scalable model for structure determination, we hope to unlock the full potential of cryo-EM and cryo-ET as a high-throughput tool for structural biology and discovery.

Levy, Axel [Stanford Univ., CA (United States); SL↗