Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Precision Measurement of the W Mass

Using proton-antiproton collision data corresponding to an integrated luminosity of 8.8 fb-1 collected in Tevatron Run 2, CDF performed a high precision measurement of the W mass. This result, 80433.5±6.4±6.9 MeV, is the most precise so far, and shows a discrepancy of 76 with Standard Model expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision HD Polarimetry with the LEGS Crossed-Coil NMR Polarimeter

We have developed a precision NMR polarimeter to observe the proton and deuteron polarization of a frozen spin HD target used in photoproduction experiments at the LEGS facility. This polarimeter uses a pair of magnetically orthogonal (''crossed'') RF coils to reduce the signal to very small levels in the absence of polarization of the sample. This reduces the thermal noise in the total signal with polarization, which improves the statistical precision of the polarization determination. Care has been taken in the design of the instrument to reduce nonthermal sources of noise, with the result that a fractional polarization uncertainty of 4% can be maintained over the lifetime of the targets, which has been as long as 19 months. The non-ideal response of the NMR circuit makes a negligible contribution to this uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Time Projection Chamber for Precision {sup 239}Pu(n,f) Cross Section Measurement

High precision measurements of the {sup 239}Pu(n,f) cross section have been identified as important for the Global Nuclear Energy Partnership (GNEP) and other programs. Currently, the uncertainty on this cross section is of the order 2-3% for neutron energies below 14 MeV and the goal is to reduce this to less than 1%. The Time Projection Chamber (TPC) has been identified as a possible tool to make this high precision measurement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precise studies on resonant energies of the first intershell (KLL) dielectronic recombination processes for He- up to O-like xenon

Precise studies of the resonant energies of KLL dielectronic recombination (DR) processes of He-, Li-, Be-, B-, C-, N-, and O-like xenon ions were performed at the Shanghai Electron Beam Ion Trap [X. Zhu et al., Nucl. Instrum. Methods Phys. Res. B 235, 509 (2005)], employing home developed high precision, high stability high voltage dividers. Influences from retardation by the capacitor of experimental setup, contact potential, space charge of the electron beam, and of ion neutralization, as well as fringing field effects were taken into account. The obtained resonant energies were, at an average uncertainty level of 0.03%, compared with calculation results by relativistic configuration interaction (RCI) theory, relativistic many-body perturbation theory (RMBPT), and by multiconfiguration Dirac-Fock (MCDF) theory. All the three predicted DR resonant energies by MCDF agree with our experiments. Among the 15 predictions by RMBPT, 13 are in good agreement with our experimental results. But only five out of 15 predictions by RCI calculation agree with our experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precision measurements of positronium decay rate and energy level

Positronium is an ideal system for the research of the bound state QED. New precise measurement of orthopositronium decay rate has been performed with an accuracy of 150 ppm, and the result combined with the last three is 7.0401{+-}0.0007 {mu}s{sup -1}. It is the first result to validate the 2nd order correction. The Hyper Fine Splitting of positronium is sensitive to the higher order corrections of the QED prediction and also to the new physics beyond Standard Model via the quantum oscillation into virtual photon. The discrepancy of 3.5{sigma} is found recently between the measured values and the QED prediction (O({alpha}{sup 3})). It might be due to the contribution of the new physics or the systematic problems in the previous measurements: (non-thermalized Ps and non-uniformity of the magnetic field). We propose new methods to measure HFS precisely without the these uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High precision high voltage divider and its application to electron beam ion traps

A high precision high voltage divider has been developed for the electron beam ion trap in Shanghai. The uncertainty caused by the temperature coefficient of resistance (TCR) and the voltage coefficient of resistance has been studied in detail and was minimized to the level of ppm (10{sup -6}) range. Once the TCR was matched between the resistors, the precision of the dividing ratio finally reached the ppm range also. We measured the delay of the divider caused by the capacitor introduced to minimize voltage ripple to be 2.35 ms. Finally we applied the divider to an experiment to measure resonant energies for some dielectronic recombination processes for highly charged xenon ions. The final energies include corrections for both space charge and fringe field effects are mostly under 0.03%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Measurements of the 278 keV {sup 14}N(p,{gamma}) and the 151 keV {sup 18}O(p,{alpha}) Resonance Parameters

In thin film technology, analytical methods for monitoring the deposition of oxide and nitride coatings and the effects of corrosive, laser and ion-beam treatments have attracted considerable attention. For depth-profiling the concentrations of light isotopes, resonant nuclear reaction analysis is an excellent non-destructive ion-beam analytical tool. We report here on precision measurements of the 278 keV {sup 14}N(p,{gamma}) and the 151 keV {sup 18}O(p,{alpha}) resonances using the high-resolution proton beam of the Goettingen IONAS accelerator. The deduced resonance energies E{sub R} and total widths {gamma}(in the laboratory system) are E{sub R} = 277.60(27) keV and {gamma} = 1115(33) eV for the {sup 14}N(p,{gamma}) resonance, and E{sub R} = 150.97(26) keV and {gamma} = 178(35) eV for the {sup 18}O(p,{alpha}) resonance. These values are significantly more precise than the ones quoted in the literature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diagnostic development in precise opacity measurement of radiatively heated Al plasma on Shenguang II laser facility

Simultaneous measurements of the self-emission spectrum, the backlighting source spectrum, and the transmission spectrum in one shot, which reduce the experimental uncertainties from shot-to-shot fluctuation, are essential for precise opacity experiments. In order to achieve precise absorption spectrum of Al plasmas, a special half sample sandwich target was designed and short backlighter was used to provide time- and space-resolving diagnostics on the Shenguang II high power laser facility. In the measurement, a cylindrical cavity with CH foam baffles was used to provide a clean x-ray radiation environment for sample heating. The x-ray source spectrum, the transmission spectrum, and the self-emission spectrum of the soft x-ray heated Al sample were recorded in one shot with a penta-erythritol tetrakis (hydroxymethy) methane C(CH{sub 2}OH){sub 4} (PET) crystal spectrometer by using the point-projection method. Experimental results have been compared with the calculation results of a detailed level accounting opacity code.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Electron Beam Polarimetry

Measurements at future electron accelerators will require unprecedented precision in the determination of electron beam polarization. Existing and novel electron beam polarization measurement schemes are examined, and ideas are being presented of how to to achieve sub-1% precision in polarization determination.

43 PARTICLE ACCELERATORS↗

Precise Lamb Shift Measurements in Hydrogen-Like Heavy Ions--Status and Perspectives

The precise determination of the energy of the Lyman {alpha}1 and {alpha}2 lines in hydrogen-like heavy ions provides a sensitive test of quantum electrodynamics in very strong Coulomb fields. For the first time, a calorimetric low-temperature detector was applied in an experiment to precisely determine the transition energy of the Lyman lines of lead ions {sup 207}pb{sup 81+} at the Experimental Storage Ring (ESR) at GSI. The detectors consist of silicon thermistors, provided by the NASA/Goddard Space Flight Center, and Pb or Sn absorbers to obtain high quantum efficiency in the energy range of 40-80 keV, where the Doppler-shifted Lyman lines are located. The measured energy of the Lyman {alpha}1 line, E(Ly-{alpha}1, {sup 207}Pb{sup 81+}) = (77937{+-}12{sub stat}{+-}23{sub syst}) eV, agrees within errors with theoretical predictions. The systematic error is mainly due to uncertainties in the non-linear energy calibration of the detectors as well as the relative position of detector and gas-jet target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fundamental Symmetries of the Early Universe and the Precision Frontier

The search for the next Standard Model of fundamental interactions is being carried out at two frontiers: the high energy frontier involving the Tevatron and Large Hadron Collider, and the high precision frontier where the focus is largely on low energy experiments. I discuss the unique and powerful window on new physics provided by the precision frontier and its complementarity to the information we hope to gain from present and future colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tau Contribution and Precision Measurement of theta{sub 23} at a Neutrino Factory

We discuss precision measurements of the leading atmospheric parameters at a standard neutrino factory. The oscillation of the muon and electron neutrinos (anti-neutrinos) to tau neutrinos (anti-neutrinos) adds to the muon events sample (both right sign and wrong sign) via leptonic decays of the taus produced through charge current interactions in the detector. We focus on how this contribution affects a precision measurement of the atmospheric mixing parameters and the deviation of nu{sub m}ureversiblenu{sub t}aumixing from maximality.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accuracy and precision in photonic Doppler velocimetry

While photonic Doppler velocimetry (PDV) is becoming a common diagnostic in dynamic compression research, its limiting accuracy and precision are not well understood. Velocity resolution is known to be inversely proportional to the time resolution, but resolution estimates differ by one to two orders of magnitude. Furthermore, resolution varies with the number of recorded signals and how these signals are analyzed. Numerical simulations reveal factors that affect accuracy and precision in PDV, and the results may be extended to a broad class of measurements. After systematic effects are eliminated, the limiting velocity uncertainty in a PDV measurement is governed by the sampling rate, the signal noise fraction, and the analysis time duration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of precision weak-link stage systems with large travel range and sub-nanometer-scale resolution

To use x-ray optics with nanometer resolution limit, scanning x-ray nanoprobes with corresponding mechanical positioning capability need to be designed. In particular, positioning stages with both sub-nanometer resolution and a positioning/scanning range of several millimeters are required. Based on our design of precision weak-link stages with interferometric encoders for the Center for Nanoscale Materials (CNM) hard x-ray nanoprobe at the Advanced Photon Source (APS) Sector 26, we have developed a new two-dimensional (2-D) weak-link stage system for nanopositioning of a specimen holder. This system provides sub-nanometer resolution, coupled with sub-nanometer metrology at a travel range of several millimeters. The 2-D weak-link stage system is designed with high structure stiffness using laminar overconstrained weak-link mechanisms [4-6]. In this paper we present the study of a linear precision weak-link stage system with sub-centimeter travel range and sub-nanometer positioning resolution. Design of a rotary weak-link stage system with 10-nrad resolution and 10-degree-level travel range is also discussed in this paper.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-precision Penning trap mass measurements for tests of the Standard Model

With the nowadays achievable accuracy in Penning trap mass spectrometry on short-lived exotic nuclides as well as stable atoms, precision fundamental tests can be performed, among them a test of the Standard Model, in particular with regard to the weak interaction, the CPT symmetry conservation, and the unitarity of the Cabibbo-Kobayashi-Maskawa quark mixing matrix. In addition, accurate mass values of specific nuclides are important for neutrino physics. The presently best tests of the Standard Model with high-precision Penning trap mass spectrometry will be reviewed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Current Status of Precision Superallowed Fermi {beta}-Decay Measurements at TRIUMF-ISAC

Recent experimental work at the TRIUMF-ISAC radioactive ion-beam facility in Vancouver Canada, has produced several new results related to precise experimental tests of fundamental symmetries. The nature of these programs range from campaigns using existing setups, to the development of new apparats to further the experimental reach. One of the primary goals has been the investigation of superallowed Fermi {beta}-decay, and its relation to Standard Model tests of CVC and CKM unitarity The extraction of experimental {beta}-decay ft values requires the measurement of three quantities: the half-life, the superallowed branching ratio, and the parent-daughter mass difference. TRIUMF-ISAC has the ability to measure each of these values with very high precision, using a gas-proportional-counter, the 8{pi}{gamma}-ray spectrometer, and TITAN, respectively. This report focuses on the recent experimental progress of the superallowed program, as well as highlighting some results from the successful halo-nucleus mass-measurement program at TITAN.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Flexible drift-compensation system for precise 3D force mapping in severe drift environments

The acquisition of dense 3D data sets is of great importance, but also a challenge for scanning probe microscopy (SPM). Thermal drift often induces severe distortions in the data, which usually constrains the acquisition of dense data sets to experiments under ultra-high vacuum and low-temperature conditions. Atom tracking is an elegant approach to compensate for thermal drift and to position the microscope tip with highest precision. Here, we present a flexible drift compensation system which can easily be connected to existing SPM hardware. Furthermore, we describe a 3D data acquisition and position correction protocol, which is capable of handling large and non-linear drift as typically present in room temperature measurements. This protocol is based on atom-tracking for precise positioning of the tip and we are able to acquire dense 3D data sets over several hours at room temperature. The performance of the protocol is demonstrated by presenting 3D data taken on a CaCO{sub 3}(1014) surface with the data density being as large as 85x85x500 pixel.

36 MATERIALS SCIENCE↗

Precision spectroscopy of light kaonic atom X-rays in the SIDDHARTA experiment

The KN system at rest makes a sensitive testing ground for low energy QCD. At the DA{Phi}NE electron-positron collider of Laboratori Nazionali di Frascati we study kaonic atoms, taking advantage of the low-energy kaons from {Phi}-mesons decaying nearly at rest. The DEAR (DA{Phi}NE Exotic Atom Research) experiment at LNF delivered the most precise data on kaonic hydrogen up to now. DEAR and its follow-up experiment SIDDHARTA (Silicon Drift Detector for Hadronic Atom Research by Timing Application) are using X-ray spectroscopy of kaonic atoms to measure the strong interaction induced shift and width of the ground state. SIDDHARTA is the first experiment on kaonic helium-3 and deuterium ever, and kaonic hydrogen was remeasured with improved precision.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗