Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power balance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Flexibility in the Energy Balancing Network of Photosynthesis Enables Safe Operation under Changing Environmental Conditions

Given their ability to harness chemical energy from the sun and generate the organic compounds necessary for life, photosynthetic organisms have the unique capacity to act simultaneously as their own power and manufacturing plant. This dual capacity presents many unique challenges, chiefly that energy supply must be perfectly balanced with energy demand to prevent photodamage and allow for optimal growth. From this perspective, we discuss the energy balancing network using recent studies and a quantitative framework for calculating metabolic ATP and NAD(P)H demand using measured leaf gas exchange and assumptions of metabolic demand. We focus on exploring how the energy balancing network itself is structured to allow safe and flexible energy supply. We discuss when the energy balancing network appears to operate optimally and when it favors high capacity instead. We also present the hypothesis that the energy balancing network itself can adapt over longer time scales to a given metabolic demand and how metabolism itself may participate in this energy balancing.

59 BASIC BIOLOGICAL SCIENCES↗

Regulations for Bat Protection in Mexico's Wind Farms

Wind energy development has expanded the fastest globally among all renewable sources during the last 20 years. However, wind farms have documented adverse impacts on bats, including mortality from collisions with turbine blades and disruptions to habitat and behavior. As the world's sixth most attractive economy for renewables, with 70 operating wind farms, Mexico and its bats now face escalating threats from the country's burgeoning wind industry. Despite this rapid growth, few studies have analyzed Mexico's regulatory framework to prevent, evaluate, and mitigate wind farm effects on bats. In this study, we reviewed Mexican laws and treaties that facilitate wind farm permitting, construction, operation, and decommissioning, and searched for guidelines that specifically address bat conservation. We found eight international pacts that promote wind power adoption along with three relevant articles in Mexico's Constitution. The General Law of Ecological Balance and Environmental Protection proved most pertinent for impact management. Supplementary guidelines from the Ministry of Environment and Natural Resources offer general strategies for evaluating wind farm impacts on bats, but adherence remains voluntary. Given expanding wind power investments across Mexico, we highlight the need for more stringent national standards that require preventative and corrective measures to protect bat populations. Tighter legislation and enforcement offer pathways toward environmentally sustainable wind energy development in Mexico.

17 WIND ENERGY↗

Application of Spaceborne Scatterometer to Study Typhoon, Tropical Hydrologic Balance and El Nino

The high spatial resolution and global coverage of a spaceborne microwave scatterometer make it a power instrument to study phenomena ranging from typhoon to El Nino Southern Oscillation which have regional and short term economic and ecological impacts as well as effects on long term and global climate changes. In this report, the application of scatterometer data, by itself, to study the intensity and the evolution of typhoon is demonstrated. The potential of combining wind vector and precipitable water derived from two spaceborne sensors to study the hydrologic balance in the tropics is discussed. The role of westerly wind bursts as a precursor of anomalous warming in the equatorial Pacific is investigated with coincident data from microwave scatterometer, altimeter and radiometer.

Liu, W. Timothy↗

Effect of superconducting solenoid model cores on spanwise iron magnet roll control

Compared with conventional ferromagnetic fuselage cores, superconducting solenoid cores appear to offer significant reductions in the projected cost of a large wind tunnel magnetic suspension and balance system. The provision of sufficient magnetic roll torque capability has been a long-standing problem with all magnetic suspension and balance systems; and the spanwise iron magnet scheme appears to be the most powerful system available. This scheme utilizes iron cores which are installed in the wings of the model. It was anticipated that the magnetization of these cores, and hence the roll torque generated, would be affected by the powerful external magnetic field of the superconducting solenoid. A preliminary study has been made of the effect of the superconducting solenoid fuselage model core concept on the spanwise iron magnet roll torque generation schemes. Computed data for one representative configuration indicate that reductions in available roll torque occur over a range of applied magnetic field levels. These results indicate that a 30-percent increase in roll electromagnet capacity over that previously determined will be required for a representative 8-foot wind tunnel magnetic suspension and balance system design.

Britcher, C. P.↗

Quad-Chip Double-Balanced Frequency Tripler

Solid-state frequency multipliers are used to produce tunable broadband sources at millimeter and submillimeter wavelengths. The maximum power produced by a single chip is limited by the electrical breakdown of the semiconductor and by the thermal management properties of the chip. The solution is to split the drive power to a frequency tripler using waveguides to divide the power among four chips, then recombine the output power from the four chips back into a single waveguide. To achieve this, a waveguide branchline quadrature hybrid coupler splits a 100-GHz input signal into two paths with a 90 relative phase shift. These two paths are split again by a pair of waveguide Y-junctions. The signals from the four outputs of the Y-junctions are tripled in frequency using balanced Schottky diode frequency triplers before being recombined with another pair of Y-junctions. A final waveguide branchline quadrature hybrid coupler completes the combination. Using four chips instead of one enables using four-times higher power input, and produces a nearly four-fold power output as compared to using a single chip. The phase shifts introduced by the quadrature hybrid couplers provide isolation for the input and output waveguides, effectively eliminating standing waves between it and surrounding components. This is accomplished without introducing the high losses and expense of ferrite isolators. A practical use of this technology is to drive local oscillators as was demonstrated around 300 GHz for a heterodyne spectrometer operating in the 2-3-THz band. Heterodyne spectroscopy in this frequency band is especially valuable for astrophysics due to the presence of a very large number of molecular spectral lines. Besides high-resolution radar and spectrographic screening applications, this technology could also be useful for laboratory spectroscopy.

Lin, Robert H.↗

Optimizing Power Line Undergrounding Decisions under Varying Wildfire Risk and Weather Scenarios

Abstract—The threat of wildfire ignitions from electric power equipment has led utilities to increasingly turn to preemptive power shutoffs, which, while effective in reducing grid-induced wildfire risk, can cause significant load loss. Undergrounding power lines is an alternative strategy for preventing grid-induced wildfires. However, undergrounding lines is costly, so an efficient undergrounding plan must balance reductions in wildfire risk and load loss with the cost of undergrounding lines. We propose a robust optimization model to identify which power lines to underground to maximize load served while limiting wildfire risk across a range of wildfire risk and weather scenarios. Since solving this problem may be computationally heavy for large power grids and many operating scenarios, we present a delayed constraint generation algorithm to iteratively add scenarios until an optimal solution is found. We evaluate the performance of this framework on the RTS-GMLC with scenarios representing a year of operating conditions and compare it with a stochastic programming formulation. Our results indicate that our undergrounding model is successful in reducing load shed and risk compared to baseline cases in which no mitigation action is taken and only power shutoffs are implemented (no undergrounding). The robust formulation also reduces more load shed than the stochastic formulation in the most extreme scenarios. Index Terms—grid resilience, optimization, transmission systems, underground power lines, wildfire risk.

Taylor, S. [Department of Electrical and Computer ↗

A Community Guide to Regulatory Barriers Affecting Microgrids (Reports 1-3)

In response to growing risks of power outages from extreme weather and aging infrastructure, communities are increasingly exploring the potential of microgrids to provide reliable energy access. Microgrids offer promising solutions to meet this challenge but face a complex landscape of non-technical barriers, particularly regulations concerning the provision and distribution of energy. Most existing legal and regulatory frameworks were designed for a centralized, one-way power system, and are often poorly suited to handle systems that independently balance distributed energy resources with local load. This three-part report series provides a strategic analysis of existing regulatory and legal factors affecting microgrid deployments to help non-technical community leaders and decision-makers better understand the feasibility of a microgrid in their community. -Report No. 1: Foundational Issues Facing Microgrids details the universal policy barriers all microgrids face, including utility interconnection processes, rate structures, and local permitting. -Report No. 2: Single Property Microgrids outlines how direct asset ownership and operating behind-the-meter can bypass some regulatory oversight, using the Blue Lake Rancheria microgrid as a case study. -Report No. 3: Multi-Property Microgrids tackles the complex challenges of crossing public rights-of-way and navigating utility franchise rights, highlighting the Coventry microgrid project. The series equips decision-makers with phased frameworks to navigate financial and regulatory complexities, engage effectively with local utilities and Authorities Having Jurisdiction (AHJs), and structure successful microgrid projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Storage Analysis

This study presents a comprehensive techno-economic characterization of energy storage and exible low carbon power generation technologies that can shift energy across days, weeks, or months to balance daily, weekly, and seasonal disparities in supply and demand. Energy storage technologies evaluated here include pumped hydropower storage (PHS), adiabatic and diabatic compressed air energy storage (CAES), vanadium redox flow batteries (VRBs), pumped thermal energy storage (P-TES), and renewably produced hydrogen stored in either geologic formations or underground pipes with re-electrification via combustion turbines in combined cycles, stationary proton exchange membrane (PEM) fuel cells, or the novel use of PEM fuel cells designed for heavy-duty vehicles (HDVs) which are expected to have shorter lives but also lower capital costs. We also evaluate flexible low-carbon power generation systems, including ethanol combustion in gas turbines and natural gas combustion with carbon capture and sequestration (CCS). We estimate current costs with literature data, use learning rates to characterize future costs, and develop capacity factors calibrated to an 85% renewables grid to calculate the levelized cost of energy (LCOE) of each technology. Results illustrate that at the 12-hour storage duration, PHS and CAES have the lowest LCOE with current costs, and VRBs become competitive if future costs are achieved. At the 120-hour storage duration, hydrogen systems with geologic storage and natural gas with CCS achieve the lowest LCOE in both current and future capital cost scenarios. In particular, the new configuration of HDV-PEM fuel cells with hydrogen storage in geologic formations evaluated here could lower the LCOE by 22-27% compared to stationary fuel cell systems typically evaluated and might help enable very high (>80%) renewable energy electric power systems. P-TES and hydrogen stored in underground pipes are the least-cost options at the 120-hour storage duration rating that do not require some form of geologic storage. Sensitivity analysis and Monte Carlo analysis illustrate that the general trends seen in this study are valid for a wide range of capacity factors and future cost scenarios. The study also illustrates that coproducing and selling hydrogen to other markets could reduce the LCOE of hydrogen systems by up to 39%.

carbon capture and sequestration↗

NASA PEMFC Development Background and History

NASA has been developing proton-exchange-membrane (PEM) fuel cell power systems for the past decade, as an upgraded technology to the alkaline fuel cells which presently provide power for the Shuttle Orbiter. All fuel cell power systems consist of one or more fuel cell stacks in combination with appropriate balance-of-plant hardware. Traditional PEM fuel cells are characterized as flow-through, in which recirculating reactant streams remove product water from the fuel cell stack. NASA recently embarked on the development of non-flow-through fuel cell systems, in which reactants are dead-ended into the fuel cell stack and product water is removed by internal wicks. This simplifies the fuel cell power system by eliminating the need for pumps to provide reactant circulation, and mechanical water separators to remove the product water from the recirculating reactant streams. By eliminating these mechanical components, the resulting fuel cell power system has lower mass, volume, and parasitic power requirements, along with higher reliability and longer life. Four vendors have designed and fabricated non-flow-through fuel cell stacks under NASA funding. One of these vendors is considered the "baseline" vendor, and the remaining three vendors are competing for the "alternate" role. Each has undergone testing of their stack hardware integrated with a NASA balance-of-plant. Future Exploration applications for this hardware include primary fuel cells for a Lunar Lander and regenerative fuel cells for Surface Systems.

Hoberecht, Mark↗

Reliability Considerations of ULP Scaled CMOS in Spacecraft Systems

NASA, the aerospace community, and other high reliability (hi-rel) users of advanced microelectronic products face many challenges as technology continues to scale into the deep sub-micron region. Decreasing the feature size of CMOS devices not only allows more components to be placed on a single chip, but it increases performance by allowing faster switching (or clock) speeds with reduced power compared to larger scaled devices. Higher performance, and lower operating and stand-by power characteristics of Ultra-Low Power (ULP) microelectronics are not only desirable, but also necessary to meet low power consumption design goals of critical spacecraft systems. The integration of these components in such systems, however, must be balanced with the overall risk tolerance of the project.

reliability↗

Report on High-Fidelity Dynamic Modeling of a Coal-Fired Steam Power Plant

As a result of the growth of renewables including solar and wind energy with fluctuating production, fossil fuel power plants are being required to cycle between high and low power production. This cycling is both at a greater frequency and over a wider range than in the past. In many cases, power plants are not designed for this type of cycling operation but can nonetheless endure these challenging operation requirements under the right conditions. In this project, optimal solution for enhanced flexible operations are being investigated using model based estimation and control techniques. To support the development of model-based estimator and model-based controls at GE Global Research, GE Steam Power configured a dynamic model using a reference steam plant design including the boiler, turbine, and water/steam conditioning systems as well as the controls needed for plant cycling with stability and reliability. The dynamic model was built using the APROS® software from VTT, and then calibrated to multiple load conditions from full load (100%TMCR) to partial loads (75%TMCR, 50%TMCR and 25%TMCR) based on internally developed steady state heat balance models at the unit level. These internal heat balance models are based on first principles and extensive engineering experiences from GE Steam Power as an OEM and a services provider. This topical report presents the structure of the unit level dynamic model, the tuning process, and representative simulation results from typical load cycling simulations using the dynamic model.

01 COAL, LIGNITE, AND PEAT↗

SPARTA: A flux adjustment methodology to interpret complex experiments

For the accurate determination of reactivity from a detector count rate, correction of spatial effects is of prime importance. This spatial correction is often provided using simulation methodologies, but this may introduce a bias if the result of the experiment is also used as input data for the simulation. Here, this work presents a flux adjustment methodology able to infer experimental reactivity and correction of spatial effects without the need for a simulation. It can process the signal from a complex experiment such as a heat balance measurement in the TREAT reactor, where control rods are continuously adjusted to maintain a constant power. In the present work, this methodology successfully computed the reactivity and the local spatial variation of the flux of a generated signal. It also proved to be robust against noise and errors on kinetic parameters and provides a credible interpretation of a heat balance experiment in TREAT. Efficiency of flux adjustment methods for complex experiment enable a better experiment interpretation less reliant on nuclear data evaluation.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluating power grid model hydropower feasibility with a river operations model

Production cost models (PCMs) simulate dispatch of generators across a large power grid and are used widely by planners to study the reliability of electricity supply. As energy systems transition away from the thermoelectric technologies that have traditionally balanced electricity supply and demand, hydropower and its representation in PCMs is of increasing importance. A limitation of PCMs applied to continental power grids with diverse generation portfolios is that hydropower generation is simulated without full consideration of complex river dynamics, leading to possible misrepresentation of grid flexibility and performance. In addition, data used in PCMs may reflect outdated operating policies. In this paper we propose a hydropower generation feasibility test for PCMs. The approach uses a detailed hydropower model to determine whether the hourly hydropower schedule from a PCM with simplified monthly parameterization can be attained after accounting for realistic river dynamics and operating policies, such as spill requirements and general water movement and balance through a cascade reservoir system. We perform this hydropower generation test for the ‘Big 10’ hydropower system on the Columbia River (part of the Western Interconnect of the United States), revealing 9% overestimation of available hydropower generation in a PCM solution in an average hydrologic year. Our evaluation provides insight on the cost and opportunities for better representing hydropower in PCMs.

54 ENVIRONMENTAL SCIENCES↗

Spacecraft Charging Current Balance Model Applied to High Voltage Solar Array Operations

Spacecraft charging induced by high voltage solar arrays can result in power losses and degradation of spacecraft surfaces. In some cases, it can even present safety issues for astronauts performing extravehicular activities. An understanding of the dominant processes contributing to spacecraft charging induced by solar arrays is important to current space missions, such as the International Space Station, and to any future space missions that may employ high voltage solar arrays. A common method of analyzing the factors contributing to spacecraft charging is the current balance model. Current balance models are based on the simple idea that the spacecraft will float to a potential such that the current collecting to the surfaces equals the current lost from the surfaces. However, when solar arrays are involved, these currents are dependent on so many factors that the equation becomes quite complicated. In order for a current balance model to be applied to solar array operations, it must incorporate the time dependent nature of the charging of dielectric surfaces in the vicinity of conductors1-3. This poster will present the factors which must be considered when developing a current balance model for high voltage solar array operations and will compare results of a current balance model with data from the Floating Potential Measurement Unit4 on board the International Space Station.

Willis, Emily M.↗

Thrust Stand for Electric Propulsion Performance Evaluation

An electric propulsion thrust stand capable of supporting testing of thrusters having a total mass of up to 125 kg and producing thrust levels between 100 microN to 1 N has been developed and tested. The design features a conventional hanging pendulum arm attached to a balance mechanism that converts horizontal deflections produced by the operating thruster into amplified vertical motion of a secondary arm. The level of amplification is changed through adjustment of the location of one of the pivot points linking the system. Response of the system depends on the relative magnitudes of the restoring moments applied by the displaced thruster mass and the twisting torsional pivots connecting the members of the balance mechanism. Displacement is measured using a non-contact, optical linear gap displacement transducer and balance oscillatory motion is attenuated using a passive, eddy-current damper. The thrust stand employs an automated leveling and thermal control system. Pools of liquid gallium are used to deliver power to the thruster without using solid wire connections, which can exert undesirable time-varying forces on the balance. These systems serve to eliminate sources of zero-drift that can occur as the stand thermally or mechanically shifts during the course of an experiment. An in-situ calibration rig allows for steady-state calibration before, during and after thruster operation. Thrust measurements were carried out on a cylindrical Hall thruster that produces mN-level thrust. The measurements were very repeatable, producing results that compare favorably with previously published performance data, but with considerably smaller uncertainty.

Polzin, Kurt A.↗

Photovoltaic systems perspective

This paper summarizes the elements of photovoltaic power system and clarifies the terminology currently used. The relationship of system efficiency and cost is described particularly for the Balance of Photovoltaic System (BOPS) area. The current status of the BOPS development activity is described. The photovoltaic systems terminology is found to be on the road to standardization. Power conditioning, energy storage, and support structure are found to be BOPS cost and/or efficiency drivers. Although the current BOPS activity has identified low-cost/high-efficiency components, further development work is necessary.

Sutton, P. D.↗

A flexible and differentiable coil proxy for stellarator equilibrium optimization

Balancing plasma performance and coil cost is a significant challenge when designing a stellarator power plant. Most current stellarator designs are produced through two-stage optimization: stage-1 for the equilibrium and stage-2 for a coil design that reproduces its magnetic configuration. Because few proxies connect both stages, two-stage optimization can produce plasmas that have high-quality physical properties but overly complex coils. In recent years, single-stage optimization has increasingly been used to optimize the plasma and coils simultaneously in order to improve the plasma–coil balance. However, all existing single-stage tools are specialized for filament coils, cannot model coil systems containing permanent magnets or dipole arrays, and continue to be challenged by numerical problems. The quasi-single-stage optimization finds a middle ground by integrating a coil optimization subproblem into stage-1 optimization. We present a flexible, differentiable coil complexity proxy based on the newly developed QUADCOIL coil optimization code. QUADCOIL is fast and can target realistic coil metrics and constraints that are unavailable to codes with comparable speed. We demonstrate the effectiveness and flexibility of the QUADCOIL proxy by presenting two QSS optimization studies. The first study produces a permanent magnet solution for the MUSE stellarator with 34% fewer magnets than previous solutions. The second study produces a coil solution for the ARIES-CS stellarator with 30% reductions in both peak and root-mean-square force.

Fu, Lanke [Princeton Plasma Physics Laboratory (PP↗

Carbon footprint prediction considering the evolution of alternative fuels and cargo: A case study of Yangtze river ships

For reducing carbon emissions in the shipping sector, application of alternative low-carbon and zero-carbon fuels is the consensus. However, requirements of economic development cannot be ignored while focusing on emission reduction. Cargo development is an important prerequisite. Considering the cargo growth as a novelty, a method to calculate the annual carbon emissions of different alternative fuel-powered ships in different cargo growth prospects and power scenarios is proposed. With respect to the time dimension, the relationship between alternative fuels, cargo, and carbon reduction is revealed. The Yangtze River bulk carrier case was studied and the life cycle carbon emission analysis of diesel, LNG hybrid, LNG, hydrogen, methanol, and ammonia were carried out. The annual carbon curves of the high, steady, and low cargo growth prospects were obtained for different scenarios of the power system structure. The results show that LNG hybrid, LNG and methanol fuels are currently the suitable choices. Their life cycle carbon emissions were reduced by 31.5–38.1% compared with those of diesel power. The carbon emissions of green hydrogen and green ammonia were reduced by 78.8% and 91.3%, respectively, compared with those of hydrogen and ammonia. The carbon reduction results of green fuels in their initial application were explored which are at 0.6–10.8%. In addition, there is a balanced annual growth rate, whose annual carbon curve will be steady under its corresponding scenario of power system structure, which could help the ship owners plan their future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗