Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “positron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Moments of event shapes in electron-positron annihilation at next-to-next-to-leading order

This article gives the perturbative next-to-next-to-leading order results for the moments of the most commonly used event shape variables associated to three-jet events in electron-positron annihilation: thrust, heavy jet mass, wide jet broadening, total jet broadening, C parameter and the Durham three-to-two-jet transition variable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

White dwarf pulsars as possible cosmic ray electron-positron factories

We suggest that white dwarf (WD) pulsars can compete with neutron star (NS) pulsars for producing the excesses of cosmic ray electrons and positrons (e{sup {+-}}) observed by the PAMELA, ATIC/PPB-BETS, Fermi, and H.E.S.S. experiments. A merger of two WDs leads to a rapidly spinning WD with a rotational energy ({approx}10{sup 50} erg) comparable to the NS case. The birth rate ({approx}10{sup -2}-10{sup -3}/yr/galaxy) is also similar, providing the right energy budget for the cosmic ray e{sup {+-}}. Applying the NS theory, we suggest that the WD pulsars can in principle produce e{sup {+-}} up to {approx}10 TeV. In contrast to the NS model, the adiabatic and radiative energy losses of e{sup {+-}} are negligible since their injection continues after the expansion of the pulsar wind nebula, and hence it is enough that a fraction {approx}1% of WDs are magnetized ({approx}10{sup 7}-10{sup 9} G) as observed. The long activity also increases the number of nearby sources ({approx}100), which reduces the Poisson fluctuation in the flux. The WD pulsars could dominate the quickly cooling e{sup {+-}} above TeV energy as a second spectral bump or even surpass the NS pulsars in the observing energy range {approx}10 GeV-1 TeV, providing a background for the dark matter signals and a nice target for the future AMS-02, CALET, and CTA experiment.

79 ASTRONOMY AND ASTROPHYSICS↗

Positron Emission Tomography Detector Development for Plant Biology

There are opportunities for the development of new tools to advance plant biology research through the use of radionuclides. Thomas Jefferson National Accelerator Facility, Duke University, West Virginia University and the University of Maryland are collaborating on the development of radionuclide imaging technologies to facilitate plant biology research. Biological research into optimizing plant productivity under various environmental constraints, biofuel and carbon sequestration research are areas that could potentially benefit from new imaging technologies. Using 11CO2 tracers, the investigators at Triangle University Nuclear Laboratory / Duke University Phytotron are currently researching the dynamical responses of plants to environmental changes forecasted from increasing greenhouse trace gases involved in global change. The biological research primary focus is to investigate the impact of elevated atmospheric CO2 and nutrients limitation on carbon and nitrogen dynamics in plants. We report here on preliminary results of 11CO2 plant imaging experiments involving barley plants using Jefferson Lab dual planar positron emission tomography detectors to image 11CO2 in live barley plants. New detector designs will be developed based on the preliminary studies reported here and further planned.

43 PARTICLE ACCELERATORS↗

Optical observation of energy loss distribution and practical range of positrons from a {sup 18}F water solution in a water-equivalent phantom

The energy loss distribution of {beta}{sup +} particles is closely related to their maximum penetration depth distribution and annihilation point distribution. The latter is of practical importance for positron emission tomography. Experimental data related to the energy loss distribution are important for comprehensive validation of physics and simulation models of {beta}{sup +} interactions. In this paper the authors present a new experimental approach that allows them to visually observe the {beta}{sup +} energy loss distribution of a solution of nuclear medicine radioisotopes in a plastic scintillator using an optical camera. The authors also report a set of the first experimental results. A water solution of {sup 18}F was localized in a small hole in a plastic scintillator (BC430). Optical imaging of the scintillator yielded visual images of the energy loss distribution with a submillimeter resolution. The radial dependence in the energy distribution was quantitatively measured by analysis of the images, and exponential fitting parameters were obtained. The authors observed that the results of Monte Carlo simulation with EGS5 (version 1.0.2) and GEANT4 (version 4.9.01.p01) were consistent with those obtained experimentally. The results of the Monte Carlo simulation indicated that for a linear scale, the energy loss distribution in the scintillator was approximately the same as that in water, and the relative shape of the energy loss distribution was close to those of the maximum penetration depth distribution and annihilation point distribution. This paper also presents discussions about the further possibilities of this optical imaging approach. Thus, optical observation of the {beta}{sup +} energy loss distribution in a scintillator is a promising technique for visual and quantitative experimental studies of {beta}{sup +} emission from a solution of radioisotopes that are used in nuclear medicine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transconvolution and the virtual positron emission tomograph-A new method for cross calibration in quantitative PET/CT imaging

Purpose: Positron emission tomography (PET)/computed tomography (CT) measurements on small lesions are impaired by the partial volume effect, which is intrinsically tied to the point spread function of the actual imaging system, including the reconstruction algorithms. The variability resulting from different point spread functions hinders the assessment of quantitative measurements in clinical routine and especially degrades comparability within multicenter trials. To improve quantitative comparability there is a need for methods to match different PET/CT systems through elimination of this systemic variability. Consequently, a new method was developed and tested that transforms the image of an object as produced by one tomograph to another image of the same object as it would have been seen by a different tomograph. The proposed new method, termed Transconvolution, compensates for differing imaging properties of different tomographs and particularly aims at quantitative comparability of PET/CT in the context of multicenter trials. Methods: To solve the problem of image normalization, the theory of Transconvolution was mathematically established together with new methods to handle point spread functions of different PET/CT systems. Knowing the point spread functions of two different imaging systems allows determining a Transconvolution function to convert one image into the other. This function is calculated by convolving one point spread function with the inverse of the other point spread function which, when adhering to certain boundary conditions such as the use of linear acquisition and image reconstruction methods, is a numerically accessible operation. For reliable measurement of such point spread functions characterizing different PET/CT systems, a dedicated solid-state phantom incorporating {sup 68}Ge/{sup 68}Ga filled spheres was developed. To iteratively determine and represent such point spread functions, exponential density functions in combination with a Gaussian distribution were introduced. Furthermore, simulation of a virtual PET system provided a standard imaging system with clearly defined properties to which the real PET systems were to be matched. A Hann window served as the modulation transfer function for the virtual PET. The Hann's apodization properties suppressed high spatial frequencies above a certain critical frequency, thereby fulfilling the above-mentioned boundary conditions. The determined point spread functions were subsequently used by the novel Transconvolution algorithm to match different PET/CT systems onto the virtual PET system. Finally, the theoretically elaborated Transconvolution method was validated transforming phantom images acquired on two different PET systems to nearly identical data sets, as they would be imaged by the virtual PET system. Results: The proposed Transconvolution method matched different PET/CT-systems for an improved and reproducible determination of a normalized activity concentration. The highest difference in measured activity concentration between the two different PET systems of 18.2% was found in spheres of 2 ml volume. Transconvolution reduced this difference down to 1.6%. In addition to reestablishing comparability the new method with its parameterization of point spread functions allowed a full characterization of imaging properties of the examined tomographs. Conclusions: By matching different tomographs to a virtual standardized imaging system, Transconvolution opens a new comprehensive method for cross calibration in quantitative PET imaging. The use of a virtual PET system restores comparability between data sets from different PET systems by exerting a common, reproducible, and defined partial volume effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The VEPP-2000 electron-positron collider: First experiments

In 2007, at the Institute of Nuclear Physics (Novosibirsk), the construction of the VEPP-2000 electron-positron collider was completed. The first electron beam was injected into the accelerator structure with turned-off solenoids of the final focus. This mode was used to tune all subsystems of the facility and to train the vacuum chamber using synchrotron radiation at electron currents of up to 150 mA. The VEPP-2000 structure with small beta functions and partially turned-on solenoids was used for the first testing of the 'round beams' scheme at an energy of 508 MeV. Beam-beam effects were studied in strong-weak and strong-strong modes. Measurements of the beam sizes in both cases showed a dependence corresponding to model predictions for round colliding beams. Using a modernized SND (spherical neutral detector), the first energy calibration of the VEPP-2000 collider was performed by measuring the excitation curve of the phimeson resonance; the phi-meson mass is known with high accuracy from previous experiments at VEEP-2M. In October 2009, a KMD-3 (cryogenic magnetic detector) was installed at the VEPP-2000 facility, and the physics program with both the SND and LMD-3 particle detectors was started in the energy range of 1-1.9 GeV. This first experimental season was completed in summer 2010 with precision energy calibration by resonant depolarization.

43 PARTICLE ACCELERATORS↗

Halo Formation And Emittance Growth of Positron Beams in Plasmas

An ultrarelativistic 28.5 GeV, 700-{micro}m-long positron bunch is focused near the entrance of a 1.4-m-long plasma with a density n{sub e} between {approx}10{sup 13} and {approx}5 x 10{sup 14} cm{sup -3}. Partial neutralization of the bunch space charge by the mobile plasma electrons results in a reduction in transverse size by a factor of {approx}3 in the high emittance plane of the beam {approx}1 m downstream from the plasma exit. As n{sub e} increases, the formation of a beam halo containing {approx}40% of the total charge is observed, indicating that the plasma focusing force is nonlinear. Numerical simulations confirm these observations. The bunch with an incoming transverse size ratio of {approx}3 and emittance ratio of {approx}5 suffers emittance growth and exits the plasma with approximately equal sizes and emittances.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tracking Synthetic Particle Paths Generated in GATE with Multi-Positron Emission Particle Tracking (MPEPT)

Multi-Positron Emission Particle Tracking (MPEPT) is able to reconstruct the position of point-sources in a PET scanner to a high degree of accuracy. Experimental and simulated trajectories of activated point-sources are compared herein to validate the GATE model of our PET scanner, and test MPEPT performance. The trajectory followed by one point-source of activity 370000 Bq is simulated in GATE, and experimentally measured for velocities 0.18, 0.22. and 0.45 cm/s moving along the major axis of the detector bore. The average difference between the prescribed and predicted point-source positions is found to be approximately 0.3 mm. However, the number of Lines of Response (LOR) reported by GATE for the 370000 Bq source is larger than the number of LOR measured in the experiments. Additional testing of the accuracy of MPEPT is provided by the simulation of 20 point-sources of 20 Bq each placed around the surface of a sphere of radius 40 mm and moving radially inward to a radius of 20 mm at a constant velocity of 1 E-6 m/s. Point-source trajectories for the GATE simulation are compared to trajectories reconstructed from the GATE generated LOR using MPEPT. The average difference between prescribed and predicted point-source position is found to be approximately 0.72 mm. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Concept of an upright wearable positron emission tomography imager in humans

Abstract Background Positron Emission Tomography ( PET ) is traditionally used to image patients in restrictive positions, with few devices allowing for upright, brain‐dedicated imaging. Our team has explored the concept of wearable PET imagers which could provide functional brain imaging of freely moving subjects. To test feasibility and determine future considerations for development, we built a rudimentary proof‐of‐concept prototype (Helmet_ PET ) and conducted tests in phantoms and four human volunteers. Methods Twelve Silicon Photomultiplier‐based detectors were assembled in a ring with exterior weight support and an interior mechanism that could be adjustably fitted to the head. We conducted brain phantom tests as well as scanned four patients scheduled for diagnostic F 18‐ FDG PET / CT imaging. For human subjects the imager was angled such that field of view included basal ganglia and visual cortex to test for typical resting‐state pattern. Imaging in two subjects was performed ~4 hr after PET / CT imaging to simulate lower injected F 18‐ FDG dose by taking advantage of the natural radioactive decay of the tracer (F 18 half‐life of 110 min), with an estimated imaging dosage of 25% of the standard. Results We found that imaging with a simple lightweight ring of detectors was feasible using a fraction of the standard radioligand dose. Activity levels in the human participants were quantitatively similar to standard PET in a set of anatomical ROI s. Typical resting‐state brain pattern activation was demonstrated even in a 1 min scan of active head rotation. Conclusion To our knowledge, this is the first demonstration of imaging a human subject with a novel wearable PET imager that moves with robust head movements. We discuss potential research and clinical applications that will drive the design of a fully functional device. Designs will need to consider trade‐offs between a low weight device with high mobility and a heavier device with greater sensitivity and larger field of view.

60 APPLIED LIFE SCIENCES↗

Inclusive measurements of inelastic electron and positron scattering from unpolarized hydrogen and deuterium targets.

Results of inclusive measurements of inelastic electron and positron scattering from unpolarized protons and deuterons at the HERMES experiment are presented. The structure functions F{sub 2}{sup p} and F{sub 2}{sup d} are determined using a parameterization of existing data for the longitudinal-to-transverse virtual-photon absorption cross-section ratio. The HERMES results provide data in the ranges 0.006 {le} x {le} 0.9 and 0.1 GeV{sup 2} {le} Q{sup 2} {le} 20 GeV{sup 2}, covering the transition region between the perturbative and the non-perturbative regimes of QCD in a so-far largely unexplored kinematic region. They are in agreement with existing world data in the region of overlap. The measured cross sections are used, in combination with data from other experiments, to perform fits to the photon-nucleon cross section using the functional form of the ALLM model. The deuteron-to-proton cross-section ratio is also determined.

08 HYDROGEN↗

C-Arm Computed Tomography Compared With Positron Emission Tomography/Computed Tomography for Treatment Planning Before Radioembolization

The purpose of this study was to determine whether rotational C-arm computed tomography (CT) allows visualization of liver metastases and adds relevant information for radioembolization (RE) treatment planning. Technetium angiography, together with C-arm CT, was performed in 47 patients to determine the feasibility for RE. C-arm CT images were compared with positron emission tomography (PET)/CT images for the detection of liver tumors. The images were also rated according one of the following three categories: (1) images that provide no additional information compared with DSA alone; (2) images that do provide additional information compared with DSA; and (2) images that had an impact on eligibility determination for and planning of the RE procedure. In all patients, 283 FDG-positive liver lesions were detected by PET. In venous contrast-phase CT, 221 (78.1%) and 15 (5.3%) of these lesions were either hypodense or hyperdense, respectively. In C-arm CT, 103 (36.4%) liver lesions were not detectable because they were outside of either the field of view or the contrast-enhanced liver segment. Another 25 (8.8%) and 98 (34.6%) of the liver lesions were either hyperdense or presented primarily as hypodense lesions with a rim enhancement, respectively. With PET/CT as the standard of reference, venous CT and C-arm CT failed to detect 47 (16.6%) and 57 (20.1%) of all liver lesions, respectively. For RE planning, C-arm CT provided no further information, provide some additional information, or had an impact on the procedure in 20 (42.5%), 15 (31.9%) and 12 (25.6%) of patients, respectively. We conclude that C-arm CT may add decisive information in patients scheduled for RE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recommended nuclear data for medical radioisotope production: diagnostic positron emitters

An IAEA coordinated research project that began in 2012 and ended in 2016 was primarily dedicated to the compilation, evaluation and recommendation of cross-section data for the production of medical radionuclides. One significant part of this work focused on diagnostic positron emitters. These particular studies consist of 69 reactions for direct and indirect or generator production of 44 Sc( 44 Ti), 52 mMn( 52 Fe), 52 gMn, 55 Co, 61 Cu, 62 Cu( 62 Zn), 66 Ga, 68 Ga( 68 Ge), 72 As( 72 Se), 73 Se, 76 Br, 82 Rb( 82 Sr), 82 mRb, 86 Y, 89 Zr, 90 Nb, 94 mTc, 110 mIn( 110 Sn), 118 Sb( 118 Te), 120 I, 122 I( 122 Xe), 128 Cs( 128 Ba), and 140 Pr( 140 Nd) medical radionuclides. The resulting reference cross-section data were obtained from Padé fits to selected and corrected experimental data, and integral thick target yields were subsequently deduced. Uncertainties in the fitted results were estimated via a Padé least-squares method with the addition of a 4% assessed systematic uncertainty. Experimental data were also compared with theoretical predictions available from the TENDL-2015 and TENDL-2017 libraries.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Bone marrow examination in patients with Ewing sarcoma/peripheral primitive neuroectodermal tumor without metastasis based on {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography

Ewing sarcoma/peripheral primitive neuroectodermal tumor (ES/PNET) is an aggressive bone tumor. Bone marrow aspiration and biopsy (BMAB) has been recognized as the gold standard for assessing bone marrow status. While the latest guideline suggests the need to omit bone marrow aspiration in patients with no findings on {sup 18}F-fluorodeoxyglucose positron emission tomography ({sup 18}F-FDG PET) based on one retrospective report, there is no study using {sup 18}F-FDG PET/computed tomography (CT). We retrospectively reviewed 26 consecutive, previously untreated, ES/PNET patients. We compare the results of bone marrow aspiration and biopsy (BMAB) and those of {sup 18}F-FDG PET/CT in ES/PNET patients. All of the 21 patients without metastases on {sup 18}F-FDG PET/CT had negative BMAB. The sensitivity of bone marrow involvement in bone metastases positive patients on {sup 18}F-FDG PET/CT was 75% (3/4), and the specificity was 100% (22/22). In addition to the metastatic findings on {sup 18}F-FDG PET/CT, tumor diameter, lactate dehydrogenase level at diagnosis, and the presence or absence of bone metastasis were factors related to bone marrow involvement. It may be a reasonable option to omit BMAB in ES/PNET patients with no distant metastasis based on {sup 18}F-FDG PET/CT findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The high matrix acquisition technique for imaging of atherosclerotic plaque inflammation in fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography with time-of-flight: Phantom study

Background: Motion artifact and partial volume effect caused underestimation of coronary plaque inflammation. This study evaluated the high matrix acquisition technique using time-of-flight (TOF) positron emission tomography/computed tomography for imaging of atherosclerotic plaque inflammation with fluorine-18 fluorodeoxyglucose in small and moving phantoms. Methods and Results: All images were reconstructed using a conventional algorithm without TOF (4 × 4 × 4 mm{sup 3} voxel size) and a high matrix algorithm with TOF (2 × 2 × 2 mm{sup 3} voxel size). Microsphere phantoms of 10, 7.9, 6.2, 5.0, and 4.0 mm diameters were acquired in 3-dimensional list-mode for 30 minutes. A heart phantom mimicking cardiac motion consisted of a hot spot simulating a plaque (φ 4 mm, φ 2 mm) on the outside of the left ventricle. In the microsphere and heart phantom study, visual discrimination, maximum activity, and target-to-background ratio using the high matrix algorithm with TOF were better than those using the conventional algorithm without TOF. Conclusion: The high matrix algorithm with TOF improves detection of small targets in phantoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Corrected coronary opacification decrease from coronary computed tomography angiography: Validation with quantitative 13N-ammonia positron emission tomography

Background: To assess the functional relevance of a coronary artery stenosis, corrected coronary opacification (CCO) decrease derived from coronary computed tomography angiography (CCTA) has been proposed. The present study aims at validating CCO decrease with quantitative 13N-ammonia positron emission tomography (PET) myocardial perfusion imaging (MPI). Methods and Results: This retrospective study consists of 39 patients who underwent hybrid CCTA/PET-MPI. From CCTA, attenuation in the coronary lumen was measured before and after a stenosis and corrected to the aorta to calculate CCO and its decrease. Relative flow reserve (RFR) was calculated by dividing the stress myocardial blood flow (MBF) of a vessel territory subtended by a stenotic coronary by the stress MBF of the reference territories without stenoses. RFR was abnormal in 11 vessel territories (27%). CCO decrease yielded a sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for prediction of an abnormal RFR of 73%, 70%, 88%, 47%, and 70%, respectively. Conclusions: CCTA-derived CCO decrease has moderate diagnostic accuracy to predict an abnormal RFR in PET-MPI. However, its high negative predictive value to rule out functional relevance of a given lesion may confer clinical implications in the diagnostic work-up of patients with a coronary stenosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Review of cardiovascular imaging in the Journal of Nuclear Cardiology 2018. Part 1 of 2: Positron emission tomography, computed tomography, and magnetic resonance

In this review, we summarize key articles that have been published in the Journal of Nuclear Cardiology in 2018 pertaining to nuclear cardiology with advanced multi-modality and hybrid imaging including positron emission tomography, cardiac-computed tomography, and magnetic resonance. In an upcoming review, we will summarize key articles that relate to the progress made in the field of single-photon emission computed tomography. We hope that these sister reviews will be useful to the reader to navigate the literature in our field.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is there a role for cardiac positron emission tomography in hypertrophic cardiomyopathy?

Coronary microvascular dysfunction and, its functional consequence, myocardial ischemia are common pathologic features in patients with hypertrophic cardiomyopathy (HCM). Both have been commonly invoked as potential triggers of and/or contributors to the underlying pathophysiological processes leading to heart failure, and malignant ventricular arrhythmias. Positron emission tomography (PET) with myocardial blood flow quantification provides a unique opportunity to evaluate the integrity and function of the coronary microcirculation in HCM. The purpose of the present review is to summarize all the pertinent literature and future perspectives of the role of PET in the evaluation and risk stratification of patients with HCM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗