Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plug”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Shielding Analyses for SNS Accelerator Power Upgrade

The Proton Power Upgrade (PPU) project [1] at Spallation Neutron Source (SNS) is aiming at increasing the neutron beam intensities at the First Target Station (FTS) and advancing accelerator capability to additionally power a future Second Target Station (STS) [2]. PPU will involve upgrading the SNS accelerator complex to double the currently available proton beam power from 1.4 to 2.8 MW, by increasing the proton beam energy from 1 GeV to 1.3 GeV and by increasing the proton beam current.PPU will enable new science capabilities enhancing the experiment throughput of the 19 existing FTS instruments, which are heavily oversubscribed. STS will include 22 additional neutron scattering instruments. Numerous neutronics analyses are performed to support PPU evaluating the FTS systems for higher beam power and for system upgrades. Part of the PPU scope is an extension of the Ring to Target Beam Transport (RTBT) line, a stub out of the accelerator tunnel for the future Ring to STS Transport (RTST) line[3]. As the RTST tunnel will not be built within the PPU project, the stub will be shielded by a plug, which is planned to be made from regular concrete.In order to provide radiation protection safety, analyses are required to design adequate plug thickness for the stub. The thickness of the stub is driven by the criterion that the area downstream of the plug is “unrestricted access area”, demanding the dose rate downstream the stub be below 0.25 mrem/h at 30 cm from the surface at normal operation and below 20 Rem/hr for accident cases. Additionally, analyses verifying the amount of soil for shielding the accelerator tunnel to the above stated requirements are performed.

Popova, Irina I.↗

Utah FORGE: Milford Triaxial Test Data and Summary from EGI labs

Six samples were evaluated in unconfined and triaxial compression, their data are included in separate excel spreadsheets, and summarized in the word document. Three samples were plugged along the axis of the core (presumed to be nominally vertical) and three samples were plugged perpendicular to the axis of the core. A designation of "V"indicates vertical or the long axis of the plugged sample is aligned with the axis of the core. Similarly, "H" indicates a sample that is nominally horizontal and cut orthogonal to the axis of the core. Stress-strain curves were made before and after the testing, and are included in the word doc. The confining pressure for this test was 2800 psi. A series of tests are being carried out on to define a failure envelope, to provide representative hydraulic fracture design parameters and for future geomechanical assessments. The samples are from well 52-21, which reaches a maximum depth of 3581 ft +/- 2 ft into a gneiss complex.

15 GEOTHERMAL ENERGY↗

Fast and Accurate Core Analysis by the Full-Immersion Pressure-Pulse Decay: Part 1—Theory

Summary Core-scale measurements are considered the ground truth that oil and gas or electric utility companies use to predict the migration of fluids such as oil, natural gas, carbon dioxide, or brine deep underground during their extraction or injection operations. To provide a greater understanding of petrophysical properties of low-permeability geologic formations such as shales and tight gas sandstones, this study introduces a novel core-analysis procedure. The technique follows conventional pressure-pulse-decay permeametry, where the pressure in an inlet chamber adjacent to a cylindrical core plug undergoes a rapid pressurization, the system is shut in, and the pressure reaches a new equilibrium. However, unlike a standard unidirectional pressure-pulse decay, the full-immersion pressure-pulse decay (Hannon 2019) applies a pressure disturbance to the entire outer surface area of the sample. This article covers the numerical simulator designed to model flow through an anisotropic porous sample in this scenario. The model assumes distinct but uniform permeabilities along the radial and axial directions of the cylindrical plug sample. When extracting a plug vertically (or perpendicular to bedding), the permeability along the radial direction associates with the horizontal permeability (i.e., parallel to bedding), whereas in the axial direction, flow occurs perpendicular to bedding (a vertical permeability). Investigations of these model outputs demonstrate an approximately 20-fold decrease in time to complete a full-immersion experiment compared with conventional pressure-pulse decay. Furthermore, the pressure-decay curves resulting from the full-immersion method have slightly different shapes than those resulting from other unidimensional transient methods. These differences begin to demonstrate that, under achievable experimental conditions, the analysis of pressure data from one full-immersion test could enable the simultaneous estimation of the apparent permeabilities parallel and perpendicular to bedding of a cylindrical sample in addition to its porosity. A follow-up article finalizes the proof of this capability with a parameter-estimation procedure and presents experimental verification through a proof-of-concept study. Described in greater detail in that article, the parameter estimator requires multiple forward simulations to analyze the data, which behooves minimizing the compute time for each simulation. By using an alternating direction implicit time-marching scheme and a structured but variably spaced grid, the numerical simulator built for this purpose provides a forward model output with suitable accuracy in approximately 0.5 seconds.

Energy & Fuels↗

Reference design and operations for deep borehole disposal of high-level radioactive waste.

A reference design and operational procedures for the disposal of high-level radioactive waste in deep boreholes have been developed and documented. The design and operations are feasible with currently available technology and meet existing safety and anticipated regulatory requirements. Objectives of the reference design include providing a baseline for more detailed technical analyses of system performance and serving as a basis for comparing design alternatives. Numerous factors suggest that deep borehole disposal of high-level radioactive waste is inherently safe. Several lines of evidence indicate that groundwater at depths of several kilometers in continental crystalline basement rocks has long residence times and low velocity. High salinity fluids have limited potential for vertical flow because of density stratification and prevent colloidal transport of radionuclides. Geochemically reducing conditions in the deep subsurface limit the solubility and enhance the retardation of key radionuclides. A non-technical advantage that the deep borehole concept may offer over a repository concept is that of facilitating incremental construction and loading at multiple perhaps regional locations. The disposal borehole would be drilled to a depth of 5,000 m using a telescoping design and would be logged and tested prior to waste emplacement. Waste canisters would be constructed of carbon steel, sealed by welds, and connected into canister strings with high-strength connections. Waste canister strings of about 200 m length would be emplaced in the lower 2,000 m of the fully cased borehole and be separated by bridge and cement plugs. Sealing of the upper part of the borehole would be done with a series of compacted bentonite seals, cement plugs, cement seals, cement plus crushed rock backfill, and bridge plugs. Elements of the reference design meet technical requirements defined in the study. Testing and operational safety assurance requirements are also defined. Overall, the results of the reference design development and the cost analysis support the technical feasibility of the deep borehole disposal concept for high-level radioactive waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Opening the Plutonium-Beryllium Neutron Sealed-Source RGMA1002-113

The radiograph of the PuBe neutron sealed-source was useful in determining dimensions and identifying construction details. This information gives the engineer and machinist a better idea of where to breach the outer container. It would be advantageous to use a higher energy radiography system to provide information about inner container dimensions, construction details, and nuclear material location to facilitate disassembly. Characterization of the inner and outer container materials would be useful for selecting proper cutting inserts to provide more efficient and cleaner cuts. A real-time, in-line method for qualitatively identifying metal compositions such as handheld x-ray fluorescent (XRF) may prove sufficient. The disassembly of PuBe sealed-sources generally involves numerous attempts to pry a lid or plug from the innermost container. The forces involved make it impractical to hold the source so this attempt must take place with the container held horizontally in the collet. The horizontal orientation risks the flow of PuBe materials out of the container when the plug is freed as occurred in this disassembly. To mitigate this risk, it was agreed that a small vise should be introduced into the glovebox to hold the container firmly in a vertical orientation for attempts to pry off lids or plugs. The vise should hold cylindrical containers firmly without inflicting scratches or gouges into sealed-source metal surfaces. Documentation of PuBe neutron sealed-source disassembly is effectively recorded with a series of professional photographs as presented in this report. Unfortunately, the prevalence of metal surfaces and materials combined with uneven, low light conditions reduce the contrast between disassembled parts and background. To improve the photographic record of disassembly, colored liner materials should be identified and introduced as a staged background for PuBe component pictures.

07 ISOTOPE AND RADIATION SOURCES↗

MarmotViz User Guide

MarmotViz is an illustrative visualization plug-in for ParaView. It is intended for generating enhanced visualizations of time-varying datasets on unstructured connected meshes. A detailed description of the implemented algorithms and program structure can be found in the related document: Generalized framework and algorithms for illustrative visualization of time-varying data on unstructured meshes . This document provides details for compiling/building MarmotViz, using the MarmotViz plug-in in ParaView, and extending the MarmotViz plug-in.

42 ENGINEERING↗

Self-decomposable Fibrous Bridging Additives for Temporary Cementitious Fracture Sealers in EGS Wells

This study evaluates compatibility of a self-degradable temporary fracture sealer with the drilling mud and plugging and self-degrading performance of different fibers to be used in combination with the sealer. The sodium silicate-activated slag/Class C fly ash (SSASC) cementitious sealer must plug fractures at 85oC to allow continuous well drilling and it must degrade and leave the fractures open for water at later times when exposed to temperatures above 200oC. The sealer showed good compatibility with the mud. Even the blend of 80/20 vol.% of sealer/mud reached a compressive strength of more than 2000 psi set as one of the material criteria, mostly due to the additional activation of the slag and Class C fly ash by the alkaline ingredient present in the drilling fluid. In contrast, the drilling fluid was detrimental to the compressive strength development in conventional Class G well cement, so that it failed to meet this criterion. Among several organic fibers tested both polyvinyl alcohol (PVA)-and nylon-based fibers showed adequate plugging of the sealer in slot nozzles of 1-in. wide x 6-in. long x 0.08 in. and 0.24 in. high under pressures up to 700 psi. PVA fibers displayed better compressive toughness and self-degrading properties than nylon. The compressive toughness of sealers made by adding 1.0 wt% 6 mm-length PVA and 0.5 wt% 19 mm-length PVA was 9.5-fold higher than that of a non-bridged sealer. One factor governing the development of such high toughness was an excellent adherence of PVA to the SSASC cement. The alkali-catalyzed self-decomposition of PVA at 200°C led to the morphological transformation of the material from a fibrous structure to a microscale flake-like structure that helped the desirable conversion of the sealer into small fragments. In contrast, nylon’s decomposition provided a reticular network structure in the self-degraded sealer resulting in bigger fragments compared against the sealer with PVA. The PVA fiber has a high potential as a self-decomposable bridging additive in the SSASC cement sealer.

15 GEOTHERMAL ENERGY↗

Lab Tests Demonstrate Effectiveness of Advanced Power Strips [Fact Sheet]

NREL engineers evaluate the functionalities of advanced power strips and help consumers choose the right one for their plug loads. Many consumer electronics devices waste energy even after they are turned off via “vampire” loads, meaning they continue to draw current as long as they remain plugged into receptacles. In a typical home with 40 plug loads, vampire loads can account for nearly 10% of household electricity use. Advanced power strips (APS) are a convenient and inexpensive way to curb this type of energy waste, and are the focus of laboratory tests conducted by the Residential Buildings group at the National Renewable Energy Laboratory (NREL). By replacing ordinary power strips with APS, appliances that are not in use can be automatically shut off. APS are designed primarily for the home office and entertainment center, where the concentration of consumer electronics is typically high.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pulsed Magnetic Welding for Advanced Core and Cladding Steel

To investigate a solid-state joining method, pulsed magnetic welding (PMW), for welding the advanced core and cladding steels to be used in Generation IV systems, with a specific application for fuel pin end-plug welding. As another alternative solid state welding technique, pulsed magnetic welding (PMW) has not been extensively explored on the advanced steels. The resultant weld can be free from microstructure defects (pores, non-metallic inclusions, segregation of alloying elements). More specifically, the following objectives are to be achieved: 1. To design a suitable welding apparatus fixture, and optimize welding parameters for repeatable and acceptable joining of the fuel pin end-plug. The welding will be evaluated using tensile tests for lap joint weldments and helium leak tests for the fuel pin end-plug; 2 Investigate the microstructural and mechanical properties changes in PMW weldments of proposed advanced core and cladding alloys; 3. Simulate the irradiation effects on the PWM weldments using ion irradiation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

DOE Hybrid and Electric Vehicle Test Platform

Based on the contract NT-42790 to the Department of Energy, “Plug-in Hybrid Ethanol Research Platform”, Advanced Vehicle Research Center (AVRC) Virginia has successfully developed the phase I electric drive train research platform which has been named as Laboratory Rapid Application Testbed (LabRAT). In phase II, LabRAT is to be upgraded into plug-in hybrid research platform, which will be capable of testing power systems for electric vehicles, and plug-in hybrid electric vehicles running on conventional as well as alternative fuels. LabRAT is configured as a rolling testbed with plentiful space for installing various component configurations. Component connections are modularized for flexibility and are easily replaced for testing various mechanisms. LabRAT is designed and built as a full functional vehicle chassis with a steering system, brake system and four wheel suspension. The rear drive axle offers maximum flexibility with a quickly changeable gear ratio final drive to accommodate different motor speed requirements. The electric drive system includes an electric motor which is mechanically connected to the rear axle through an integrated speed/torque sensor. Initially, a 100 kW UQM motor and corresponding UQM motor controller is used which can be easily replaced with another motor/controller combination. A lithium iron phosphate (LiFePO4) battery pack is installed, which consists of 108 cells of 100 AH capacity, giving the total energy capacity of 32.5 kWh. Correspondingly, a fully functional battery management system (BMS) is installed to perform battery cell operation monitoring, cell voltage balancing, and reporting battery real time operating parameters to vehicle controller. An advanced vehicle controller ECU is installed for controlling the drive train. The vehicle controller ECU receives traction or braking torque command from driver through accelerator and brake pedal position sensors and battery operating signals from the BMS through CAN BUS, and then generates motor torque command (traction or braking) to the motor controller based on the control algorithm software embedded in the vehicle controller ECU. The vehicle controller ECU is a re-programmable electronic control unit. Any control algorithm software developed can be easily downloaded to vehicle controller ECU to test any newly developed control strategy. The flexibility of the control system significantly enhances the practical applicability of the LabRAT. A new test methodology has been developed for the LabRAT simulating any vehicles running on road with different weights from compact passenger car to light duty truck on an AC or eddy current dynamometers without much effort for modification of the system. LabRAT is equipped with a fully functional data acquisition system supplied by CyberMetrix. The measurement points along the drive train are DC electric power between battery pack and motor controller input, AC electric power between motor controller and electric motor, mechanical power between motor and rear axle. The data acquisition system is designed with more capability than current requirements in order to meet the requirements for phase II.

33 ADVANCED PROPULSION SYSTEMS↗

Public Key-Based Need-to-Know Authorization Engine Final Report CRADA No. TSB-1553-98

The goals of this project were to develop a public key-based authentication service plug-in based on LLNL's requirements, integrate the public key-based authentication with the Intra Verse authorization service adn the LLNL NTK server by developing a full-featured version of the prototyped Intra Verse need-to-know plug in; and to test the authorization and need-to-know plug-in in a secured extranet prototype among selected national Labs.

97 MATHEMATICS AND COMPUTING↗

Charging Electric Vehicles in Smart Cities: An EVI-Pro Analysis of Columbus, Ohio

With the support of the U.S. Department of Energy's Vehicle Technologies Office, the National Renewable Energy Laboratory (NREL) worked with the City of Columbus, Ohio, to develop a plan for the expansion of the region's network of charging stations to support increased adoption of plug-in electric vehicles (PEVs) in the local market. NREL's Electric Vehicle Infrastructure Projection (EVI-Pro) model was used to generate scenarios of regional charging infrastructure to support consumer PEV adoption. Results indicate that approximately 400 Level 2 plugs at multi-unit dwellings and 350 Level 2 plugs at non-residential locations are required to support Columbus' primary PEV goal of 5,300 PEVs on the road by the end of 2019. This analysis finds that while consumer demand for fast charging is expected to remain low (due to modest anticipated adoption of short-range battery electric vehicles), a minimum level of fast charging coverage across the city is required to ease consumer range anxiety concerns by providing a safety net for unexpected charging events. Sensitivity analyses around some key assumptions have also been performed; of these, consumer preference for PHEV versus BEV and for their electric driving range, ambient conditions, and availability of residential charging at multi-unit dwellings were identified as key determinants of the non-residential PEV charging infrastructure required to support PEV adoption. The results discussed in this report can be leveraged by similar U.S. cities as part of a strategy to accelerate PEV adoption in the light-duty vehicle market.

25 ENERGY STORAGE↗

SCC Aerosol Transport Model Summary Report

The purpose of the present work is to introduce a generic and reliable numerical model for prediction of aerosol transport, deposition, and plugging in leak paths similar to stress corrosion cracks while accounting for potential plugging formation. The model is dynamic (changing leak path geometry due to plugging) and it relies on the numerical solution of the aerosol transport equation in one dimension using finite differences. An extensive validation exercise (particle diameters: 0.01-10 μm and pressure difference up to 12 kPa) was conducted based on comparisons with experimental and theoretical data. The developed model is fairly general since it is based on a generic mechanistic description of the aerosol flow and particle deposition in the leak path, without requiring experimental fittings other than using the leak rate parameters commonly available in practical applications. Despite the approximate agreement of the model with the experimental data, the obtained predictions can be qualified as realistic. This is a major achievement of the model, which has been based on generic aerosol mechanics with no reference or adjustment to experimental data.

42 ENGINEERING↗

Fiscal Year 2018 Sodium-CO2 Interaction Test

An experiment campaign was continued in Fiscal Year 2018 in the Argonne National Laboratory (Argonne) SNAKE facility that investigated the interactions between supercritical carbon dioxide (sCO 2 ) and sodium through injection of sCO 2 into an open surface sodium pool. Two of fifteen previous SNAKE tests revealed that self-plugging of the leakage path/nozzle occurs at higher initial sodium temperatures of about 500 ºC due to chemical reactions involving CO 2 , sodium, and sodium-CO 2 reaction products. At lower sodium temperatures, the interaction phenomena involve consumption of injected CO 2 and formation of an agglomerated mass of reaction products without self-plugging. The FY 2018 test investigated interactions at an intermediate initial sodium temperature of about 411 ºC, representative of the interior of a sodium-to-CO 2 heat exchanger in a Sodium-Cooled Fast Reactor (SFR) sCO 2 Brayton Cycle energy conversion system. The experiment was successfully conducted and did not show self-plugging as evidenced by a sustained chemical reaction between the injected CO 2 and sodium and consumption of CO 2 .

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CX-100 Manufacturing (Final Project Report)

This report details the work completed under the CX-100 blade manufacturing project. It presents the tooling design and manufacturing, blade production, blade instrumentation, blade shipping and adapter plate design and fabrication. The CX-100 blade was designed to demonstrate the efficient use of carbon fiber in the spar cap of a wind turbine blade. The baseline blade used for this project was the ERS-100 (Revision D) wind turbine blade. ERS-100 master plugs – for both the high pressure and low pressure skins – were modified to create plugs for the CX-100. Using the new CX-100 master skin plugs, high pressure and low pressure molds were fabricated. Similar modifications were also completed on the shear web plug/mold, the blade assembly fixture and the root stud insertion fixture. Once all of the tooling modifications were complete, a production run of seven CX-100 prototype blades was undertaken. Of those seven blades, four were instrumented with strain gauges before final assembly. After production at the TPI facility in Rhode Island, the blades were shipped to various test sites: two blades to the NWTC at NREL, two blades to Sandia National Laboratory and three blades to the USDA-ARS turbine field test facility located in Bushland, Texas. An adapter plate was designed to allow the CX-100 blades to be installed on existing Micron 65/13M turbines at the USDA site. The conclusion of this program is the kick-off of the blade testing at the three testing facilities.

42 ENGINEERING↗

Quantifying the Tangible Value of Public Electric Vehicle Charging Infrastructure

The lack of an extensive public recharging infrastructure is an important barrier to the growth of the plug-in electric vehicle (PEV) market. Because charging infrastructure is likely to be underutilized during the early stages of market development, it is difficult for decision makers to decide how much to invest in public charging stations. Quantifying the value of public charging infrastructure to current and potential future owners of PEVs is essential for estimating the benefits of charging stations to current PEV owners and for predicting the impact on future PEV sales. This paper estimates consumers’ willingness to pay for public charging infrastructure in the context of utility maximization. The objective is to provide a method for valuing charging infrastructure that can inform investment decisions and be used in forecasting models to predict the impacts on future PEV sales. A basic theory of the tangible value of charging infrastructure is developed as a function of PEV type, range, recharging time and existing infrastructure. Existing simulation studies provide functional relationships that quantify the ability of charging infrastructure to enable additional miles of electrified travel. The enabled travel functions are used to predict impact of infrastructure deployment on incremental electrified travel for 1) plug-in hybrids and 2) intra-regional and 3) inter-regional travel by all-electric vehicles. The willingness to pay for increased electrified miles is derived from the willingness to pay for increased electric driving range, based on econometric studies of plug-in vehicle choice. The result is a set of three functions that can be used to calculate the marginal willingness-to-pay for public charging infrastructure as a function of vehicle attributes, existing charging infrastructure, energy prices and annual vehicle travel.

33 ADVANCED PROPULSION SYSTEMS↗

Accidental Disassembly of a Multi Branch Outlet Strip with Surge Protector (Investigation Report)

On December 16 a worker attempted to disconnect a computer plug from a multi outlet surge protector strip. The plastic housing of the surge protector disintegrated while the plug was pulled exposing the bare conductors of the internal wiring. The worker disconnected the wall plug on the multi outlet strip and de-energized the outlet strip. The worker contacted the FOD and the FOD called the ISR DESO for advice. The DESO collected the pieces and performed an autopsy on the device.

42 ENGINEERING↗

Development and Demonstration of Medium-Heavy Duty PHEV Work Trucks

The heavy-duty vehicle market (Class 6-8) has been a difficult segment for the introduction of plug-in vehicles due to the large energy storage requirement (with corresponding cost), challenging duty cycles, and the diversity of vehicle configurations. The Work Truck market represents a significant opportunity for Heavy-Duty PHEV adoption. (1) The usage cycle includes driving and stationary/worksite power requirements, ensuring full daily usage of the grid-charged battery (battery size: 15-30kWhr). Though daily driving can often be short (an average of 26 miles per day), worksite power includes substantial demand (hydraulics, exportable 110/220V power, 12V support, HVAC). (2) Worksite power demands for conventional vehicles require continuous loaded engine operation, resulting in significant emissions, fuel consumption and noise impacts. (3) These trucks serve an industry that is highly diverse in final vehicle duty cycle, configuration, and jobsite power demands resulting in the need for a modular, configurable hybrid solution. Through this program, Odyne has developed and demonstrated a medium/heavy duty plug-in hybrid solution capable of meeting the needs of the work truck market while delivering fuel and emissions reductions of 50% or greater when evaluated against the full-day work truck duty cycle. The Odyne system developed in this project was released for commercial sale as the G2V7 Odyne Plug-in Hybrid and ePTO systems. The testing and field demonstration proved that the Odyne hybrid system is capable of reducing work truck fuel use and emissions by over 50% while subsequent commercial sales demonstrate the flexibility of the modular design and the capability to support electric systems of 12 – 30 kW and hydraulic based systems of 60 kW (80 HP) or greater. Odyne is continuing to work with suppliers on reducing component costs and working with supporting agencies to initiate projects to increase the driving and full day fuel and emissions savings in order to continue to improve the customer value and return on investment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗