Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optimisation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

SU-E-T-205: Improving Quality Assurance of HDR Brachytherapy: Verifying Agreement Between Planned and Delivered Dose Distributions Using DICOM RTDose and Advanced Film Dosimetry

Purpose: HDR brachytherapy is undergoing significant development, and quality assurance (QA) checks must keep pace. Current recommendations do not adequately verify delivered against planned dose distributions: This is particularly relevant for new treatment planning system (TPS) calculation algorithms (non TG-43 based), and an era of significant patient-specific plan optimisation. Full system checks are desirable in modern QA recommendations, complementary to device-centric individual tests. We present a QA system incorporating TPS calculation, dose distribution export, HDR unit performance, and dose distribution measurement. Such an approach, more common in external beam radiotherapy, has not previously been reported in the literature for brachytherapy. Methods: Our QA method was tested at 24 UK brachytherapy centres. As a novel approach, we used the TPS DICOM RTDose file export to compare planned dose distribution with that measured using Gafchromic EBT3 films placed around clinical brachytherapy treatment applicators. Gamma analysis was used to compare the dose distributions. Dose difference and distance to agreement were determined at prescription Point A. Accurate film dosimetry was achieved using a glass compression plate at scanning to ensure physically-flat films, simultaneous scanning of known dose films with measurement films, and triple-channel dosimetric analysis. Results: The mean gamma pass rate of RTDose compared to film-measured dose distributions was 98.1% at 3%(local), 2 mm criteria. The mean dose difference, measured to planned, at Point A was -0.5% for plastic treatment applicators and -2.4% for metal applicators, due to shielding not accounted for in TPS. The mean distance to agreement was 0.6 mm. Conclusion: It is recommended to develop brachytherapy QA to include full-system verification of agreement between planned and delivered dose distributions. This is a novel approach for HDR brachytherapy QA. A methodology using advanced film dosimetry and gamma comparison to DICOM RTDose files has been demonstrated as suitable to fulfil this need.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-215: Interactive Dose Shaping: Proof of Concept Study for Six Prostate Patients

Purpose: To provide a proof of concept study for IMRT treatment planning through interactive dose shaping (IDS) by utilising the respective tools to create IMRT treatment plans for six prostate patients. Methods: The IDS planning paradigm aims to perform interactive local dose adaptations of an IMRT plan without compromising already established valuable dose features in real-time. Various IDS tools are available in our in-house treatment planning software Dynaplan and were utilised to create IMRT treatment plans for six patients with an adeno-carcinoma of the prostate. The sequenced IDS treatment plans were compared to conventionally optimised clinically approved plans (9 beams, co-planar). The starting point consisted of open fields. The IDS tools were utilised to sculpt dose out of the rectum and bladder. For each patient, several IDS plans were created, with different trade-offs between organ sparing and target coverage. The reference dose distributions were imported into Dynaplan. For each patient, the IDS treatment plan with a similar or better trade-off between target coverage and OAR sparing was selected for plan evaluation, guided by a physician. Pencil beam dose calculation was performed on a grid with a voxel size of 1.95×1.95×2.0 mm{sup 3}. D98%, D2%, mean dose and dose-volume indicators as specified by Quantec were calculated for plan evaluation. Results: It was possible to utilise the software prototype to generate treatment plans for prostate patient geometries in 15–45 minutes. Individual local dose adaptations could be performed in less than one second. The average differences compared to the reference plans were for the mean dose: 0.0 Gy (boost) and 1.2 Gy (CTV), for D98%: −1.1 Gy and for D2%: 1.1 Gy (both target volumes). The dose-volume quality indicators were well below the Quantec constraints. Conclusion: Real-time treatment planning utilising IDS is feasible and has the potential to be implemented clinically. Research at The Institute of Cancer Research is supported by Cancer Research UK under Programme C46/A10588.

60 APPLIED LIFE SCIENCES↗

WE-G-BRF-09: Force- and Image-Adaptive Strategies for Robotised Placement of 4D Ultrasound Probes

Purpose: To allow continuous acquisition of high quality 4D ultrasound images for non-invasive live tracking of tumours for IGRT, image- and force-adaptive strategies for robotised placement of 4D ultrasound probes are developed and evaluated. Methods: The developed robotised ultrasound system is based on a 6-axes industrial robot (adept Viper s850) carrying a 4D ultrasound transducer with a mounted force-torque sensor. The force-adaptive placement strategies include probe position control using artificial potential fields and contact pressure regulation by a PD controller strategy. The basis for live target tracking is a continuous minimum contact pressure to ensure good image quality and high patient comfort. This contact pressure can be significantly disturbed by respiratory movements and has to be compensated. All measurements were performed on human subjects under realistic conditions. When performing cardiac ultrasound, rib- and lung shadows are a common source of interference and can disrupt the tracking. To ensure continuous tracking, these artefacts had to be detected to automatically realign the probe. The detection is realised by multiple algorithms based on entropy calculations as well as a determination of the image quality. Results: Through active contact pressure regulation it was possible to reduce the variance of the contact pressure by 89.79% despite respiratory motion of the chest. The results regarding the image processing clearly demonstrate the feasibility to detect image artefacts like rib shadows in real-time. Conclusion: In all cases, it was possible to stabilise the image quality by active contact pressure control and automatically detected image artefacts. This fact enables the possibility to compensate for such interferences by realigning the probe and thus continuously optimising the ultrasound images. This is a huge step towards fully automated transducer positioning and opens the possibility for stable target tracking in ultrasoundguided radiation therapy requiring contact pressure of 5–10 N. This work was supported by the Graduate School for Computing in Medicine and Life Sciences funded by Germany's Excellence Initiative [DFG GSC 235/1].

60 APPLIED LIFE SCIENCES↗

SU-E-J-200: Operation of An Electron Accelerator On An Integrated MR-Linac System

Purpose: An integrated MRI guided radiotherapy system poses a challenge of operating a linear accelerator in the presence of a magnetic field as the magnetic force acting on the electrons could Result in radiation source displacement and subsequent reduction of dose output. It was the purpose of this work to test the performance of a linac in the presence of a 1.5T MRI system. Methods: The first experimental MRI guided radiotherapy system at UMC-Utrecht consisting of an Elekta linac rotating around a 1.5T Magnex magnet was examined. A passive magnetic shield was simulated, designed and installed to reduce the influence of the MRI magnet stray field on the electron beamline. The B field inside the shield was measured as a function of gantry angle and measurements of dose rate constancy upon gantry rotation were performed. Results: The magnitude of the magnetic field on the electron beam path without the shield was as high as 70G. It varied by up to 15G with gantry rotation due to the presence of metal beams in the bunker floor which resulted in dose output drop of up to 70% at certain gantry angles. With the prototype shield, field magnitude was reduced to well below 0.5G everywhere along the electron beam path. Field variation with gantry rotation was decreased to below 0.2G and enabled dose output of the linac to be recovered at all gantry angles. The homogeneity of the field inside the MRI magnet has not been compromised. Conclusion: It was demonstrated that the influence of the 1.5T magnet and the bunker design on the linac operation has been minimised. The performance will be further improved on the Elekta Atlantic system which incorporates a newly developed and optimised Philips magnet design and bunker construction. J Harasimowicz, D Roberts, I Shinton and S Sund are employed by Elekta Limited Crawley, H Wang and M Zhong are employed by Elekta Beijing Medical Systems Co. Ltd., J Overweg is employed by Philips Technologie GmbH Forschungslaboratorien.

60 APPLIED LIFE SCIENCES↗

SU-E-T-653: Quantifying Inter-Fraction Range Uncertainty for Input Into Robust Proton Planning

Purpose: To provide a method for quantifying centre- and tumour site-specific population range uncertainty due to inter-fraction motion for use within robust proton planning and plan analysis. PTV-based and probabilistic/robust plans depend upon accurate knowledge of geometric and range uncertainties. If the uncertainty model is inaccurate, both types of plan, PTV or probabilistic, could produce under-dosing of the target and/or overdosing of OAR. Methods: Daily mega-voltage volumetric imaging data from previously treated radiotherapy patients has been used to investigate inter-fraction changes to water equivalent path-length (WEPL). Daily image-guidance scans were carried out for each patient and corrected for changes in CTV position (using rigid transformations). An effective depth algorithm was used to determine residual range changes, after corrections were applied, by comparing WEPL within the CTV at each fraction for several beam angles. This method has been demonstrated for nine prostate and seven head and neck. Results: Inter-fraction range changes for the head and neck patient sample were Σ=3.39mm, σ=4.72mm and overall mean =−1.82mm; for prostate Σ=5.64mm, σ=5.91mm and overall mean =0.98 mm. The choice of beam angle for head and neck did not affect the inter-fraction range error significantly; however this was not the same for prostate. Greater range changes were seen using a lateral beam compared to an anterior beam for prostate due to relative motion of the prostate and femoral heads. Conclusion: A method has been developed to quantify population range changes due to inter-fraction motion. The results show a non-zero mean for these samples, as well as significant Σ and σ, highlighting the importance of quantifying uncertainties and use of image guidance. Such information can be used in robust optimisation algorithms and for analysing treatment plan robustness. It may also help in establishing beam start conditions at planning and for establishing adaptive planning protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-BRD-09: Novel MRI Compatible Electron Accelerator for MRI-Linac Radiotherapy

Purpose: MRI guided radiotherapy is a rapidly growing field; however current linacs are not designed to operate in MRI fringe fields. As such, current MRI- Linac systems require magnetic shielding, impairing MR image quality and system flexibility. Here, we present a bespoke electron accelerator concept with robust operation in in-line magnetic fields. Methods: For in-line MRI-Linac systems, electron gun performance is the major constraint on accelerator performance. To overcome this, we propose placing a cathode directly within the first accelerating cavity. Such a configuration is used extensively in high energy particle physics, but not previously for radiotherapy. Benchmarked computational modelling (CST, Darmstadt, Germany) was employed to design and assess a 5.5 cell side coupled accelerator with a temperature limited thermionic cathode in the first accelerating cell. This simulation was coupled to magnetic fields from a 1T MRI model to assess robustness in magnetic fields for Source to Isocenter Distance between 1 and 2 meters. Performance was compared to a conventional electron gun based system in the same magnetic field. Results: A temperature limited cathode (work function 1.8eV, temperature 1245K, emission constant 60A/K/cm{sup 2}) will emit a mean current density of 24mA/mm{sup 2} (Richardson’s Law). We modeled a circular cathode with radius 2mm and mean current 300mA. Capture efficiency of the device was 43%, resulting in target current of 130 mA. The electron beam had a FWHM of 0.2mm, and mean energy of 5.9MeV (interquartile spread of 0.1MeV). Such an electron beam is suitable for radiotherapy, comparing favourably to conventional systems. This model was robust to operation the MRI fringe field, with a maximum current loss of 6% compared to 85% for the conventional system. Conclusion: The bespoke electron accelerator is robust to operation in in-line magnetic fields. This will enable MRI-Linacs with no accelerator magnetic shielding, and minimise painstaking optimisation of the MRI fringe field. This work was supported by US (NIH) and Australian (NHMRC & Cancer Institute NSW) government research funding. In addition, I would like to thank cancer institute NSW and the Ingham Institute for scholarship support.

60 APPLIED LIFE SCIENCES↗

WE-AB-209-08: Novel Beam-Specific Adaptive Margins for Reducing Organ-At-Risk Doses

Purpose: Current practice of using 3D margins in radiotherapy with high-energy photon beams provides larger-than-required target coverage. According to the photon depth-dose curve, target displacements in beam direction result in minute changes in dose delivered. We exploit this behavior by generating margins on a per-beam basis which simultaneously account for the relative distance of the target and adjacent organs-at-risk (OARs). Methods: For each beam, we consider only geometrical uncertainties of the target location perpendicular to beam direction. By weighting voxels based on its proximity to an OAR, we generate adaptive margins that yield similar overall target coverage probability and reduced OAR dose-burden, at the expense of increased target volume. Three IMRT plans, using 3D margins and 2D per-beam margins with and without adaptation, were generated for five prostate patients with a prescription dose Dpres of 78Gy in 2Gy fractions using identical optimisation constraints. Systematic uncertainties of 1.1, 1.1, 1.5mm in the LR, SI, and AP directions, respectively, and 0.9, 1.1, 1.0mm for the random uncertainties, were assumed. A verification tool was employed to simulate the effects of systematic and random errors using a population size of 50,000. The fraction of the population that satisfies or violates a given DVH constraint was used for comparison. Results: We observe similar target coverage across all plans, with at least 97.5% of the population meeting the D98%>95%Dpres constraint. When looking at the probability of the population receiving D5<70Gy for the rectum, we observed median absolute increases of 23.61% (range, 2.15%–27.85%) and 6.97% (range, 0.65%–17.76%) using per-beam margins with and without adaptation, respectively, relative to using 3D margins. Conclusion: We observed sufficient and similar target coverage using per-beam margins. By adapting each per-beam margin away from an OAR, we can further reduce OAR dose without significantly lowering target coverage probability by irradiating more less-important tissues. This work is supported by Cancer Research UK under Programme C33589/A19908. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR.

07 ISOTOPE AND RADIATION SOURCES↗

WE-DE-BRA-06: Evaluation of the Imaging Performance of a Novel Water-Equivalent EPID

Purpose: To evaluate the megavoltage imaging performance of a novel, water-equivalent electronic portal imaging device (EPID) developed for simultaneous imaging and dosimetry applications in radiotherapy. Methods: A novel EPID prototype based on active matrix flat panel imager technology has been developed by our group and previously reported to exhibit a water-equivalent dose response. It was constructed by replacing all components above the photodiode detector in a standard clinical EPID (including the copper plate and phosphor screen) with a 15 × 15 cm{sup 2} array of plastic scintillator fibers. Individual fibers measured 0.5 × 0.5 × 30 mm{sup 3}. Spatial resolution was evaluated experimentally relative to that of a standard EPID with the thin slit technique to measure the modulation transfer function (MTF) for 6 MV x-ray beams. Monte Carlo (MC) EPID models were used to benchmark simulated MTFs against the measurements. The zero spatial frequency detective quantum efficiency (DQE(0)) was simulated for both EPID configurations and a preliminary optimization of the prototype was performed by evaluating DQE(0) as a function of fiber length up to 50 mm. Results: The MC-simulated DQE(0) for the prototype EPID configuration was ∼7 times greater than that of the standard EPID. The prototype’s DQE(0) also increased approximately linearly with fiber length, from ∼1% at 5 mm length to ∼11% at 50 mm length. The standard EPID MTF was greater than the prototype EPID’s for all spatial frequencies, reflecting the trade off between x-ray detection efficiency and spatial resolution with thick scintillators. Conclusion: This study offers promising evidence that a water-equivalent EPID previously demonstrated for radiotherapy dosimetry may also be used for radiotherapy imaging applications. Future studies on optimising the detector design will be performed to develop a next-generation prototype that offers improved megavoltage imaging performance, with the aim to at least match that of current clinical EPIDs. Funding for this project was provided by an Australian Research Council Linkage Project grant (2015) between The University of Sydney, South Western Sydney Local Health District and Perkin-Elmer Pty Ltd.

60 APPLIED LIFE SCIENCES↗

WE-H-BRA-07: Mechanistic Modelling of the Relative Biological Effectiveness of Heavy Charged Particles

Purpose Uncertainty in the Relative Biological Effectiveness (RBE) of heavy charged particles compared to photons remains one of the major uncertainties in particle therapy. As RBEs depend strongly on clinical variables such as tissue type, dose, and radiation quality, more accurate individualised models are needed to fully optimise treatments. MethodsWe have developed a model of DNA damage and repair following X-ray irradiation in a number of settings, incorporating mechanistic descriptions of DNA repair pathways, geometric effects on DNA repair, cell cycle effects and cell death. Our model has previously been shown to accurately predict a range of biological endpoints including chromosome aberrations, mutations, and cell death. This model was combined with nanodosimetric models of individual ion tracks to calculate the additional probability of lethal damage forming within a single track. These lethal damage probabilities can be used to predict survival and RBE for cells irradiated with ions of different Linear Energy Transfer (LET). ResultsBy combining the X-ray response model with nanodosimetry information, predictions of RBE can be made without cell-line specific fitting. The model’s RBE predictions were found to agree well with empirical proton RBE models (Mean absolute difference between models of 1.9% and 1.8% for cells with α/β ratios of 9 and 1.4, respectively, for LETs between 0 and 15 keV/µm). The model also accurately recovers the impact of high-LET carbon ion exposures, showing both the reduced efficacy of ions at extremely high LET, as well as the impact of defects in non-homologous end joining on RBE values in Chinese Hamster Ovary cells.ConclusionOur model is predicts RBE without the inclusion of empirical LET fitting parameters for a range of experimental conditions. This approach has the potential to deliver improved personalisation of particle therapy, with future developments allowing for the calculation of individualised RBEs. SJM is supported by a Marie Curie International Outgoing Fellowship from the European Commission’s FP7 program (EC FP7 MC-IOF-623630)

60 APPLIED LIFE SCIENCES↗

Synthesis, crystal structure, HF and DFT calculations of 1-(2-chlorobenzyl)-N-(1-(2-chlorobenzyl)-4,5-dihydro-1H-imidazol-2-yl) -1H-benzimidazol-2-amine

The titled compound (1), has been synthesized and characterized by IR and {sup 1}H-NMR spectroscopy, and single crystal X-ray diffraction. The compound crystallizes in the triclinic space group P-1. The crystal structure is stabilized by C-H-{pi} and aromatic {pi}-{pi} interactions. There are also intramolecular N-H-N and C-H-N hydrogen bonds in the molecule. The use of quantum chemical calculations to characterise and optimise the choice of material is illustrated by ab initio treatments. Vibrational frequencies and LUMO-HOMO energy difference of 1 have also been investigated by Density functional theory (DFT) and Hartree-Fock (HF) calculations. Calculated frequencies are in good agreement with the corresponding experimental data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Drug providers’ perspectives on antibiotic misuse practices in eastern Ethiopia: a qualitative study

Objective Antibiotic misuse includes using them to treat colds and influenza, obtaining them without a prescription, not finishing the prescribed course and sharing them with others. Although drug providers are well positioned to advise clients on proper stewardship practices, antibiotic misuse continues to rise in Ethiopia. It necessitates an understanding of why drug providers failed to limit such risky behaviours. This study aimed to explore drug providers’ perspectives on antibiotic misuse practices in eastern Ethiopia. Setting The study was conducted in rural Haramaya district and Harar town, eastern Ethiopia. Design and participants An exploratory qualitative study was undertaken between March and June 2023, among the 15 drug providers. In-depth interviews were conducted using pilot-tested, semistructured questions. The interviews were transcribed verbatim, translated into English and analysed thematically. The analyses considered the entire dataset and field notes. Results The study identified self-medication pressures, non-prescribed dispensing motives, insufficient regulatory functions and a lack of specific antibiotic use policy as the key contributors to antibiotic misuse. We found previous usage experience, a desire to avoid extra costs and a lack of essential diagnostics and antibiotics in public institutions as the key drivers of non-prescribed antibiotic access from private drug suppliers. Non-prescribed antibiotic dispensing in pharmacies was driven by client satisfaction, financial gain, business survival and market competition from informal sellers. Antibiotic misuse in the setting has also been linked to traditional and ineffective dispensing audits, inadequate regulatory oversights and policy gaps. Conclusion This study highlights profits and oversimplified access to antibiotics as the main motivations for their misuse. It also identifies the traditional antibiotic dispensing audit as an inefficient regulatory operation. Hence, enforcing specific antibiotic usage policy guidance that entails an automated practice audit, a responsible office and insurance coverage for persons with financial limitations can help optimise antibiotic use while reducing resistance consequences.

General & Internal Medicine↗

Electron and photon energy calibration with the ATLAS detector using LHC Run 1 data

This paper presents the electron and photon energy calibration achieved with the ATLAS detector using about 25 fb -1 of LHC proton–proton collision data taken at centre-of-mass energies of √s=7 and 8 TeV. The reconstruction of electron and photon energies is optimised using multivariate algorithms. The response of the calorimeter layers is equalised in data and simulation, and the longitudinal profile of the electromagnetic showers is exploited to estimate the passive material in front of the calorimeter and reoptimise the detector simulation. After all corrections, the Z resonance is used to set the absolute energy scale. For electrons from Z decays, the achieved calibration is typically accurate to 0.05 % in most of the detector acceptance, rising to 0.2 % in regions with large amounts of passive material. The remaining inaccuracy is less than 0.2–1 % for electrons with a transverse energy of 10 GeV, and is on average 0.3 % for photons. The detector resolution is determined with a relative inaccuracy of less than 10 % for electrons and photons up to 60 GeV transverse energy, rising to 40 % for transverse energies above 500 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction of hadronic decay products of tau leptons with the ATLAS experiment

This document presents a new method of reconstructing the individual charged and neutral hadrons in tau decays with the ATLAS detector. The reconstructed hadrons are used to classify the decay mode and to calculate the visible four-momentum of reconstructed tau candidates, significantly improving the resolution with respect to the calibration in the existing tau reconstruction. The performance of the reconstruction algorithm is optimised and evaluated using simulation and validated using samples of Z → ττ and Z(→ μμ)+jets events selected from proton–proton collisions at a centre-of-mass energy √s = 8 TeV, corresponding to an integrated luminosity of 5 fb -1 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of $WW\gamma $ and $WZ\gamma $ production in $pp$ collisions at $\sqrt{s} = {8} \,{\text {TeV}}$ and search for anomalous quartic gauge couplings with the ATLAS experiment

This paper presents a study of WWγ and WZγ triboson production using events from proton–proton collisions at a centre-of-mass energy of √s = 8 TeV recorded with the ATLAS detector at the LHC and corresponding to an integrated luminosity of 20.2 fb –1 . The WWγ production cross-section is determined using a final state containing an electron, a muon, a photon, and neutrinos (eνμνγ). Upper limits on the production cross-section of the eνμνγ final state and the WWγ and WZγ final states containing an electron or a muon, two jets, a photon, and a neutrino (eνjjγ or μνjjγ) are also derived. The results are compared to the cross-sections predicted by the Standard Model at next-to-leading order in the strong-coupling constant. In addition, upper limits on the production cross-sections are derived in a fiducial region optimised for a search for new physics beyond the Standard Model. The results are interpreted in the context of anomalous quartic gauge couplings using an effective field theory. Confidence intervals at 95% confidence level are derived for the 14 coupling coefficients to which WWγ and WZγ production are sensitive.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for a heavy resonance decaying to a top quark and a vector-like top quark in the lepton + jets final state in pp collisions at $\sqrt{s} = 13\,\text {TeV} $

Here a search is presented for a heavy spin-1 resonance $\mathrm {Z}'$ decaying to a top quark and a vector-like top quark partner $\text {T} $ in the lepton + jets final state. The search is performed using a data set of $\mathrm {p}$ $\mathrm {p}$ collisions at a centre-of-mass energy of 13 $\,\text {TeV}$ corresponding to an integrated luminosity of $35.9{\,\text {fb}^{-1}} $ as recorded by the CMS experiment at the CERN LHC in the year 2016. The analysis is optimised for final states arising from the $\text {T} $ decay modes to a top quark and a Higgs or $\mathrm {Z}$ boson ( $\text {T} \rightarrow \mathrm {H} \mathrm {t}, \mathrm {Z} \mathrm {t}$ ). The event selection makes use of resolved and merged top quark decay products, as well as decays of boosted Higgs bosons and $\mathrm {Z}$ and $\mathrm {W}$ bosons using jet substructure techniques. No significant deviation from the standard model background expectation is observed. Exclusion limits on the product of the cross section and branching fraction for $\mathrm {Z}'\rightarrow \mathrm {t}\text {T}, \text {T} \rightarrow \mathrm {H} \mathrm {t}, \mathrm {Z} \mathrm {t}, \mathrm {W}\mathrm {b}$ are presented for various combinations of the $\mathrm {Z}'$ resonance mass and the vector-like $\text {T} $ quark mass. These results represent the most stringent limits to date for the decay mode $\mathrm {Z}'\rightarrow \mathrm {t}\text {T} \rightarrow \mathrm {t}\mathrm {H} \mathrm {t}$ . In a benchmark model with extra dimensions, invoking a heavy spin-1 resonance $\mathrm {G}^* $ , masses of the $\mathrm {G}^* $ between 1.5 and 2.3 $\,\text {TeV}$ and between 2.0 and 2.4 $\,\text {TeV}$ are excluded for $\text {T} $ masses of 1.2 and 1.5 $\,\text {TeV}$ , respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗