Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Flow Injection Electrochemical Quartz Crystal Microbalance with ICP-OES Detection: Electroprecipitation and Stripping of Lanthanum and Neodymium in a Flow Cell

We used an improved version of our hyphenated analysis technique, flow injection electrochemical quartz crystal microbalance (EQCM) with inductively coupled optical emission spectroscopy, to investigate the electroprecipitation of lanthanum and neodymium from flowing solutions. The improved version has two independent flow injection circuits, allowing different conditions for electrochemical precipitation (pH=4.3 or 2.6) and quick stripping (2% HNO3) with EQCM mass detection and ICP-OES elemental analysis. Lanthanum or neodymium ions in a 500 uL sample were injected into a carrier stream and deposited onto an EQCM housed in a micro flow cell, owing to a localized high-pH layer. The deposits are subsequently stripped from the electrode using HNO3 and analyzed downstream using an ICP-OES. We found that using acidic solutions without supporting electrolyte leads to an increase of the amount of lanthanum detected by 4-fold. The enhanced deposition can be attributed to enhanced mass transfer by migration. Furthermore, we showed that by applying chronopotentiometry, we can detect a change in the hydrogen evolution reaction mechanism that enables the precipitation of lanthanides on the surface of the electrode. Understanding and enhancing the deposition of lanthanides is relevant for elemental or isotopic detection in nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Development of fracture diagnostic methods for fluid distribution based on quantitative interpretation of distributed acoustic sensing and distributed temperature sensing

Multistage hydraulic fracturing design on horizontal wells has significantly evolved with larger fluid volume, more fracturing stages, and tighter perforation cluster spacing to efficiently stimulate unconventional reservoirs. From the published field observations, the recent fracturing design results in complex fracture networks or swarm of fractures. Fracture treatment evaluation is extremely challenging in such a case because of the large amount of variables in well completion and stimulation design. Combined measurements from different technologies can help in fracture diagnosis. Fluid distribution, either during fracture injection or during production, directly relates to the stimulation efficiency at the cluster level and at the stage level. Because it is unlikely in the real world to distribute the injected fluid uniformly among all the clusters, we need diagnostic techniques to generate the flow profile along a lateral. Fiber-optic measurements, such as distributed acoustic sensing (DAS) and distributed temperature sensing (DTS), are currently used to diagnose downhole flow conditions. This technology allows us to qualitatively confirm the fluid flow profile and other issues occurring downhole during fracturing such as leakage through plugs. For optimizing a fracturing design, we also need to understand how the design parameters are correlated with the stimulation efficiency. In this study, we combine two sets of models of DAS and DTS data interpretation for injected fluid volume distribution. The DAS is interpreted based on an empirical correlation between fluid flow rates and frequency band energy from the acoustic signals. The DTS is interpreted by performing temperature history match-based thermal energy conservation. Because of the completely different physics behind the interpretations, the confirmation of two interpretations provides confidence in fluid distribution.

Geochemistry & Geophysics↗

Effect of heating/cooling dynamics in the hysteresis loop and tunable IR emissivity of VO 2 thin films

We experimentally investigate the semiconductor-to-metal transition (SMT) in vanadium dioxide thin films using an infrared thermographic technique. During the semiconductor to metal phase change process, VO 2 optical properties dynamically change and infrared emission undergoes a hysteresis loop due to differences between heating and cooling stages. The shape of the hysteresis loop was accurately monitored under different dynamic heating/cooling rates. In order to quantify and understand the effects of different rates, we used a numerical modelling approach in which a VO 2 thin layer was modeled as metamaterial. The main experimental findings are interpreted assuming that both the rate of formation and shape of metallic inclusions are tuned with the heating/cooling rate. The structural transition from monoclinic to tetragonal phases is the main mechanism for controlling the global properties of the phase transition. However, our experimental results reveal that the dynamics of the heating/cooling process can become a useful parameter for further tuning options and lays out a macroscopic optical sensing scheme for the microscopic phase change dynamics of VO 2 . Our study sheds light on phase-transition dynamics and their effect on the infrared emission spectra of VO 2 thin films, therefore enabling the heating/cooling rate to be an additional parameter to control infrared emission characteristics of thermal emitters. The hysteresis loop represents the phase coexistence region, thus being of fundamental importance for several applications, such as the operation of radiative thermal logic elements based on phase transition materials. For such applications, the phase transition region is shifted for heating and cooling processes. We also show that, depending on the way the phase change elements are heated, the temperature operation range will be slightly modified.

42 ENGINEERING↗

The right conditions for high-precision dynamic temperature and heat capacity measurement via pyrometry and conductivity

The pursuit of accurate bulk temperature T under extreme conditions has been a long-standing goal of the high pressure science community, complicated by a lack of data to inform models. To reach these extremely high-pressure, high-temperature (high P − T) conditions, a combination of dynamic and heated static experiments (e.g., diamond or gem anvil cel experiments) are used. For example, in a diamond anvil cell (DAC) experiment, a sample placed in the DAC is first pressurized. Following pressurization, the sample T is increased either by heating the entire DAC (usually using resistive heating, and limited to ∼1000K) or by applying intense laser power to the sample surfaces. In a dynamic experiment, the process of pressurizing the sample also heats it. In the case of shock physics experiments, such heating is substantial, easily reaching thousands of Kelvin; in our work we have seen T ∼17000K. Most methods of measuring temperature at ambient are not compatible with experiments under these high-pressure, high-temperature conditions: thermocouples break, melt, or have conductivity properties that differ from ambient where they are calibrated; thermometers would melt; both are too slow. As a result most methods are based on non-contact techniques such as x-ray diffraction broadening, neutron scattering, or optical methods. Of these, optical methods using the visible and near-infrared region of the spectrum are the most commonly used as the sources and detectors are readily available. In the case of optical methods the optical depth, and therefore the measurement location, is limited to the surface. When a window or anvil material is used, heat flows from the sample into the window/anvil. Likewise, if the sample undergoes a change in thermodynamic state, such as expansion upon release, different T may be expected. As a result, the surface or apparent temperature T app measurement will differ from the bulk or interior temperature that is desired. This surface measurement must be related to the bulk measurement using thermal transport models and material models. While it is tempting to conclude that one should just use x-ray methods that directly probe the interior, even these methods have been shown to depend on thermal transport and material models. Regardless of the method used to create the high P − T condition, therefore, we must understand the role of thermal transport and material models upon our interpretation of the T measurement, as well as the errors and uncertainties associated with the choice of models used in the analysis. This is a substantial area of research and this paper is by no means a complete survey of the relevant sources of uncertainty. For example, we have yet to begin to address alternate transport models in a detailed manner (e.g., Tan-Ahrens), or the many models that use additional layers to approximate melting, turbulence, or epitaxial phenomena). Likewise, we have not explored the impact upon uncertainty of thermal models that use temperature-dependent thermal transport coefficients, or the wide range of material models that can be applied. Instead, this paper focuses on using one simple model, the Urtiew-Grover model, to understand the sources of error in T measurement so that we may identify how best to focus future research efforts to return the best improvements and avoid working on over-optimizing a single type of measurement. To this end, we work through some of the best and worst case scenarios for T measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impacts of a Prescribed Fire on Air Quality in Central New Mexico

A short-duration but high-impact air quality event occurred on 28 November 2018 along the Rio Grande Valley of New Mexico. This fire occurred outside the typical wildfire season, and greatly impacted the air quality in Socorro, NM, and the surroundings. Measurements were taken during the event using an aerosol light scattering technique (integrating nephelometer) and a particulate mass concentration monitor (DustTrak PM optical monitor). The instruments sampled the ambient air during the event on the campus of the New Mexico Institute of Mining and Technology in Socorro, New Mexico. The peak values on a 5-min basis of light scattering and the PM mass concentration reached 470 Mm -1 and 270 µg/m 3 , respectively. We examined the meteorological context of the event using local meteorological data and back trajectories using the NOAA HYSPLIT model to determine atmospheric transport and possible sources. Several fires, both prescribed and wildfires, occurred in the region including a prescribed burn at Bosque del Apache National Wildlife Refuge (17 km south-southeast of the receptor site). The data suggest that the prescribed burn at Bosque del Apache was the dominant contributor due to transport evidence and the event’s narrow spatiotemporal extent. The increasing importance of restoring ecosystem function using prescribed fire in wildland fire management will likely lead to more frequent air quality impacts and sets up policy tradeoffs that require a balance between these public goals. This study examines the evidence of the effects of a prescribed fire in a protected wildland area impacting the air quality in a nearby populated area.

54 ENVIRONMENTAL SCIENCES↗

ADRIANO2 Calorimeter performance from 2022 Prototypes

A novel high-granularity dual-readout calorimetric technique was developed as part of the T1604 collaboration research program. The building block of ADRIANO2 Calorimeter consists of a pair of optically isolated, small sized tiles made of scintillating plastic and lead glass. The two components of the dual-readout energy compensation technique. Furthermore,Cˇerenkovlightfromtheleadglassareexploitedtoforhighresolutiontimingmeasurements,whilehigh granularity from scintillating plastic can be used to probe the spatial component of the particle shower. This setup works for excellent energy resolution and particle identification for REDTOP as it is crucial for a calorimeter to detect and identify the decay products of eta/eta-prime mesons. Measurements were collected on several ADRIANO2 prototypes between February to December 2022 to evaluate the detector performance. The key metrics extracted from the analyses are presented in this paper are the efficiencies and light-yi eld for various tile configurations. The measured values will be used as input parameters for improved REDTOP Montecarlo simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement report: Molecular composition, optical properties, and radiative effects of water-soluble organic carbon in snowpack samples from northern Xinjiang, China

Abstract. Water-soluble organic carbon (WSOC) in the cryosphere has an important impact on the biogeochemistry cycling and snow–ice surface energy balance through changes in the surface albedo. This work reports on the chemical characterization of WSOC in 28 representative snowpack samples collected across a regional area of northern Xinjiang, northwestern China. We employed multimodal analytical chemistry techniques to investigate both bulk and molecular-level composition of WSOC and its optical properties, informing the follow-up radiative forcing (RF) modeling estimates. Based on the geographic differences and proximity of emission sources, the snowpack collection sites were grouped as urban/industrial (U), rural/remote (R), and soil-influenced (S) sites, for which average WSOC total mass loadings were measured as 1968 ± 953 ng g−1 (U), 885 ± 328 ng g−1 (R), and 2082 ± 1438 ng g−1 (S), respectively. The S sites showed the higher mass absorption coefficients at 365 nm (MAC365) of 0.94 ± 0.31 m2 g−1 compared to those of U and R sites (0.39 ± 0.11 m2 g−1 and 0.38 ± 0.12 m2 g−1, respectively). Bulk composition of WSOC in the snowpack samples and its basic source apportionment was inferred from the excitation–emission matrices and the parallel factor analysis featuring relative contributions of one protein-like (PRLIS) and two humic-like (HULIS-1 and HULIS-2) components with ratios specific to each of the S, U, and R sites. Additionally, a sample from site 120 showed unique pollutant concentrations and spectroscopic features remarkably different from all other U, R, and S samples. Molecular-level characterization of WSOC using high-resolution mass spectrometry (HRMS) provided further insights into chemical differences among four types of samples (U, R, S, and 120). Specifically, many reduced-sulfur-containing species with high degrees of unsaturation and aromaticity were uniquely identified in U samples, suggesting an anthropogenic source. Aliphatic/protein-like species showed the highest contribution in R samples, indicating their biogenic origin. The WSOC components from S samples showed high oxygenation and saturation levels. A few unique CHON and CHONS compounds with high unsaturation degree and molecular weight were detected in the 120 sample, which might be anthraquinone derivatives from plant debris. Modeling of the WSOC-induced RF values showed warming effects of 0.04 to 0.59 W m−2 among different groups of sites, which contribute up to 16 % of that caused by black carbon (BC), demonstrating the important influences of WSOC on the snow energy budget.

54 ENVIRONMENTAL SCIENCES↗

Spatiotemporal dispersion compensation for a 200-THz noncollinear optical parametric amplifier

A noncollinear optical parametric amplifier (NOPA) can produce few-cycle femtosecond laser pulses that are ideally suited for time-resolved optical spectroscopy measurements. However, the nonlinear-optical process giving rise to ultrabroadband pulses is susceptible to spatiotemporal dispersion problems. Here, we detail refinements, including chirped-pulse amplification (CPA) and pulse-front matching (PFM), that minimize spatiotemporal dispersion and thereby improve the properties of ultrabroadband pulses produced by a NOPA. Here, the description includes a rationale behind the choices of optical and optomechanical components, as well as assessment protocols. We demonstrate these techniques using a 1 kHz, second-harmonic Ti:sapphire pump configuration, which produces ~5-fs duration pulses that span from about 500 to 800 nm with a bandwidth of about 200 THz. To demonstrate the utility of the CPA-PFM-NOPA, we measure vibrational quantum beats in the transient–absorption spectrum of methylene blue, a dye molecule that serves as a reference standard.

47 OTHER INSTRUMENTATION↗

Dual-Comb Spectroscopy to Tethered Balloon System (DCS to TBS) Field Campaign Report

There is a critical need for the ability to detect, quantify, and attribute sources and sinks of greenhouse gases (GHGs) with high temporal and spatial resolution. Current methods are typically based on continuously operating near-surface point sensors or intermittent aerial/satellite observations. Dual optical frequency comb spectroscopy (“dual-comb spectroscopy”; DCS) is a laser-based technique that can bridge this sensing gap by providing high-precision, high-accuracy, and high-temporal-resolution detection and quantification of trace gases over kilometer-length scales, connecting local and regional observations. A single DCS system can also provide spatial resolution for source/sink attribution with the addition of a few minor optical elements, enabling cross-validation of other observations (e.g., Total Carbon Column Observing Network [TCCON], Orbiting Carbon Observatory [OCO-2/3], Greenhouse Gases Observing Satellite [GOSAT-1/2][).

54 ENVIRONMENTAL SCIENCES↗

Near-field infrared microscopy: A novel analytic mapping technique to nanocharacterize calcium silicate-based cement materials

Infrared imaging via scattering-type scanning near-field optical microscopy (s-SNOM) allows chemical mapping of organic and inorganic materials with nanoscale spatial resolution. However, its potential adaptation to the complex multiphase structure of Portland cement is yet to be explored. Here we demonstrate the successful implementation of s-SNOM to spatially resolve coexisting chemical phases in tricalcium silicate, Portland cement's main compound, with 20-nm resolution. We found that s-SNOM is sensitive to different anhydrous polymorphic phases, revealing nanoscale domains that are ‘invisible’ to other microscopic techniques. Furthermore, s-SNOM's ability to distinguish the unhydrated and hydrated phases signifies its great promise as an analytical tool to study the complex hydration process of cement. The key to s-SNOM's application was nano-modifying the surface roughness of the cement samples, allowing nanoscale infrared imaging without topographical artifacts. Our study opens a window for infrared spectral microscopy in cement and other porous inorganic materials.

36 MATERIALS SCIENCE↗

Optical cycling on thorium monoxide for an improved test of fundamental symmetries

Optical cycling refers to repeated excitation and spontaneous emission on an electronic transition in an atom or molecule. Optical cycling in molecules can enable a wide range of quantum control and readout techniques, but unfortunately it has only been demonstrated on a small class of alkalilike or alkaline-earth-like molecules. Thorium monoxide (ThO), a molecule used in one of the most precise permanent electron electric dipole moment (eEDM) searches (ACME†) [Andreev et al., Nature (London) 562, 355 (2018)], does not fall into this category. In this work, we demonstrate the first optical cycling on this nonconventional class over a range of experimental parameter space, including laser intensity, polarization switching rate, and interaction time. We show that both the 𝐽 = 1 and 𝐽 = 2 rotational levels of ThO molecule are capable of cycling an average of 11(2) photons with a single laser, at scattering rates of 1.9⁢(6) × 10 6 and 2.3⁢(7) × 10 6 s −1 , respectively, before population is lost to other vibronic levels. We outline a scheme to apply this demonstrated optical cycling in an ACME-style eEDM measurement, improving the detection efficiency by over fourfold compared to noncycling fluorescence detection. This would lead to over a twofold enhancement in the statistical sensitivity of the eEDM search. This optical-cycling scheme can be further extended to scatter ∼100 photons, which would enable a wider range of quantum control and sensing using ThO molecules.

Atomic & molecular processes in external fields↗

Development Fiber Optic Distributed System for Direct Detection of Subsurface Gases Leakages

Carbon, natural gas, and hydrogen gas storage is an emerging solution to safeguard us against pollution, support goals of negative carbon emission, and protect sources of renewable energy. Properly constructed storage wells provide a virtually impervious barrier to any unintended subsurface transmission. The ability to ensure the long-term integrity of such wells is vital to the success of any storage operation and be successful in the public eyes. Therefore, robust monitoring of any gas migration into the subsurface is highly sought. A fiber-optic distributed chemical sensor (DCS) enables monitoring of long-term well integrity along its depth, ensuring the success of any storage operation and bolsters public acceptance of the safety of the reservoir via leak early detection. The same technique can be applied to gas monitoring in pipeline networks and nuclear stockpile monitoring applications. Fiber based Raman spectroscopy enables DCS, as optical fibers can be deployed in virtually any environment and relay spectroscopic information over long distances back to the user. Hollow core fibers (HCF) make excellent DCSs as the air core of the fiber allows gas from the environment to diffuse into the core, which interacts with the laser signal that is carried in the air core. This work builds upon the previous LDRD project, Fiber Optic System for Direct Detection of Carbon Dioxide Leakage in Carbon Storage Wells (21-FS-003), in which the feasibility of Raman spectroscopy detection of Carbon Dioxide (CO2) in HCF detection was demonstrated. We mitigated the risk of this DCS technology by establishing and completing five objectives. The first objective was to model and optically characterize HCF uptake of CO2, establishing the relationship between HCF length, gas diffusion time, detectable gas concentration, and measured Raman intensity. In objective two, we developed a fiber core drilling recipe to enable additional diffusion ports in the fiber core and established a method for maintaining fiber strength and integrity post drilling. Objective three characterized the drilled fibers against the undrilled fibers, establishing the differences in the gas mechanics and optical properties and provided parameters to iterate the drilling process. In objective four, a fusion splicing technique was developed to join the HCF to conventional single-mode fibers, localizing the gas detection point at the drilled HCF hole, emulating a DCS. Lastly, objective five was the testing of the sensor in Edgar Mines at Colorado School of Mines on a CO2 pipeline with a simulated leak, to showcase the ability to detect CO2 leaks. This capstone result showed CO2 leak detection in < 10 minutes, raising the technology readiness level of HCF segments as deployable DCS.

organic↗

Cascaded Optical Nonlinearities in Dielectric Metasurfaces

Since the discovery of the laser, optical nonlinearities have been at the core of efficient light conversion sources. Typically, thick transparent crystals or quasi-phase matched waveguides are utilized in conjunction with phase-matching techniques to select a single parametric process. In recent years, due to the rapid developments in artificially structured materials, optical frequency mixing has been achieved at the nanoscale in subwavelength resonators arrayed as metasurfaces. Phase matching becomes relaxed for these wavelength-scale structures, and all allowed nonlinear processes can, in principle, occur on an equal footing. This could promote harmonic generation via a cascaded (consisting of several frequency mixing steps) process. However, so far, all reported work on dielectric metasurfaces have assumed frequency mixing from a direct (single step) nonlinear process. In this work, we prove the existence of cascaded second-order optical nonlinearities by analyzing the second- and third-wave mixing from a highly nonlinear metasurface in conjunction with polarization selection rules and crystal symmetries. We find that the third-wave mixing signal from a cascaded process can be of comparable strength to that from conventional third-harmonic generation and that surface nonlinearities are the dominant mechanism that contributes to cascaded second-order nonlinearities in our metasurface.

36 MATERIALS SCIENCE↗

Utilizing distributed acoustic sensing and ocean bottom fiber optic cables for submarine structural characterization

The sparsity of permanent seismic instrumentation in marine environments often limits the availability of subsea information on geohazards, including active fault systems, in both time and space. One sensing resource that provides observational access to the seafloor environment are existing networks of ocean bottom fiber optic cables; these cables, coupled to modern distributed acoustic sensing (DAS) systems, can provide dense arrays of broadband seismic observations capable of recording both seismic events and the ambient noise wavefield. Here, we report a marine DAS application which demonstrates the strength and limitation of this new technique on submarine structural characterization. Based on ambient noise DAS records on a 20 km section of a fiber optic cable offshore of Moss Landing, CA, in Monterey Bay, we extract Scholte waves from DAS ambient noise records using interferometry techniques and invert the resulting multimodal dispersion curves to recover a high resolution 2D shear-wave velocity image of the near seafloor sediments. We show for the first time that the migration of coherently scattered Scholte waves observed on DAS records can provide an approach for resolving sharp lateral contrasts in subsurface properties, particularly shallow faults and depositional features near the seafloor. Our results provide improved constraints on shallow submarine features in Monterey Bay, including fault zones and paleo-channel deposits, thus highlighting one of many possible geophysical uses of the marine cable network.

47 OTHER INSTRUMENTATION↗

Optically pumped polarized 3 He ++ ion source development for RHIC/EIC

The proposed polarized 3 He ++ acceleration in RHIC and the future Electron-Ion Collider will require about 2×10 11 ions in the source pulse. A new technique had been proposed for production of high intensity polarized 3 He ++ ion beams. It is based on ionization and accumulation of the 3 He gas (polarized by metastability-exchange optical pumping and in the 5T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel 3 He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized 3 He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3–5 T field has been developed. The 3 He polarization 80–85% (and sufficiently long ~30 min relaxation time) was obtained in the “open” cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and 3 He 4 He absolute nuclear polarimeter at 6 MeV 3 He ++ beam energy is also presented here in this work.

43 PARTICLE ACCELERATORS↗

Gradient Field Detection Using Interference of Stimulated Microwave Optical Sidebands

Here, we demonstrate that stimulated microwave optical sideband generation using parametric frequency conversion can be utilized as a powerful technique for coherent state detection in atomic physics experiments. The technique has advantages over traditional absorption or polarization rotation-based measurements and enables the isolation of signal photons from probe photons. We outline a theoretical framework that accurately models sideband generation using a density matrix formalism. Using this technique, we demonstrate a novel intrinsic magnetic gradiometer that detects magnetic gradient fields between two spatially separated vapor cells by measuring the frequency of the beat note between sidebands generated within each cell. The sidebands are produced with high efficiency using parametric frequency conversion of a probe beam interacting with 87 Rb atoms in a coherent superposition of magnetically sensitive hyperfine ground states. Interference between the sidebands generates a low-frequency beat note whose frequency is determined by the magnetic field gradient between the two vapor cells. In contrast to traditional gradiometers the intermediate step of measuring the magnetic field experienced by the two vapor cells is unnecessary. We show that this technique can be readily implemented in a practical device by demonstrating a compact magnetic gradiometer sensor head with a sensitivity of 25 fT/cm/ √ Hz with a 4.4 cm baseline, while operating in a noisy laboratory environment unshielded from Earth’s field.

74 ATOMIC AND MOLECULAR PHYSICS↗

Assessment of Readout Techniques for Passive Monitors

This fiscal year (FY) 2023 report on passive temperature sensors covers two main objectives: to demonstrate that the optical dilatometer can successfully process disc shaped silicon carbide (SiC) temperature monitors (TMs), and to demonstrate proof of concept for using the capacitance readout method to read printed melt wires. The SiC objective was successfully met by annealing and analyzing, via optical dilatometry, all eight 3-mm SiC discs provided by the Nuclear Science User Facilities (NSUF) Idaho State University (ISU) Nanostructured Steels for Enhanced Radiation Tolerance (N SERT) experiment, which was irradiated at Idaho National Laboratory (INL)’s Advanced Test Reactor (ATR). Per the ISU N SERT experiment, capsule 1 (KGT 3828 1 and KGT 3828-2) had a design temperature of 300°C +/- 50°C and an exposure of 2 dpa +/- 10%; capsule 2 (KGT 4600 and KGT 4609) had a design temperature of 300°C +/- 50°C and an exposure of 6 dpa +/- 10%; capsule 3 (KGT 4639 C and KGT 4639-D) had a design temperature of 500°C +/- 50°C and an exposure of 6 dpa +/- 10%; and capsule 4 (KGT 3841 3 and KGT 3841 4) had a design temperature of 500°C +/- 50°C and an exposure of 2 dpa +/- 10%. The target exposure rates, in dpa, are the neutron damage for various types of nanostructured steels. All but three SiC TMs (KGT 4600, KGT 4639 D, and KGT 3841 4) revealed averaged peak irradiation temperatures that fell within the design temperature ranges. The three SiC TMs that did not fall within the design temperatures ranges were at least 100°C below that target temperature. Furthermore, SiC TM KGT 3841 C revealed two irradiation regimes: one closer to the 300°C design temperature, and the other closer to the 500°C design temperature. Also, all the SiC TMs’ averaged peak irradiation temperatures came in anywhere between 20°C and 240°C below the irradiation temperatures predicted by the thermal models. This showed the optical dilatometry method to be a reliable and less time intensive process for determining averaged peak irradiation temperatures from passive SiC TMs such as rods and discs. Under the Advanced Sensors and Instrumentation (ASI) program in FY-23, Boise State University (BSU) proposed to demonstrate proof of concept for using a capacitance readout technique applicable to printed melt wires; however, they were stymied by the complexity of the capacitance readout method. In support of the BSU work, INL developed an additively manufactured (AM) ceramic package for encapsulating the new melt wires. Inks were synthesized at BSU that used new protocols rather than following previously established protocols implemented at INL, and testing of various temperatures was conducted at BSU to evaluate the melting behaviors of the printed melt wires. The result was that the capacitance readout technique showed promise but also created more challenges than originally anticipated. For example, the tin ink synthesized at BSU showed unusual melting behaviors that did nothing to enhance the performance of the final printed melt wire prototype in terms of the capacitance readout method. To make the proof of concept work when applied to the printed melt wires, the ASI program would need to invest further resources and time. Consequently, the program is not planning to continue this proof of concept work in FY-24, based on the progress and findings achieved in FY-23.

36 MATERIALS SCIENCE↗

In situ tuning of optomechanical crystals with nano-oxidation

Optomechanical crystals are a promising device platform for quantum transduction and sensing. Precise targeting of the optical and acoustic resonance frequencies of these devices is crucial for future advances on these fronts. However, fabrication disorder in these wavelength-scale nanoscale devices typically leads to inhomogeneous resonance frequencies. Here we achieve in situ , selective frequency tuning of optical and acoustic resonances in silicon optomechanical crystals via electric field-induced nano-oxidation using an atomic-force microscope. Our method can achieve a tuning range >2nm (0.13%) for the optical resonance wavelength in the telecom C-band, and >60MHz (1.2%) for the acoustic resonance frequency at 5 GHz. The tuning resolution of 1.1 pm for the optical wavelength and 150 kHz for the acoustic frequency allows us to spectrally align multiple optomechanical crystal resonators using a pattern generation algorithm. Our results establish a method for precise post-fabrication tuning of optomechanical crystals. This technique can enable coupled optomechanical resonator arrays, scalable resonant optomechanical circuits, and frequency matching of microwave-optical quantum transducers.

Hatipoglu, Utku (ORCID:0000000205119196)↗