Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

In-situ TEM Holder for Ultrafast, Multimodal Imaging

This project developed a prototype in-situ specimen holder product to transmission electron microscope (TEM) users that drastically expand the usability of TEM by combining nanoscale laser excitation and optical signal collection. A commercial prototype has been constructed and a few nanoscale materials characterization experiments have been performed to validate its performance and demonstrate its utility in real scientific studies, for example, in-situ characterization and mapping of defects in the synthesis of nanostructures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Overcoming Oxidation State-Dependent Spectral Interferences: Online Monitoring of U(VI) Reduction to U(IV) via Raman and UV–vis Spectroscopy

Analytical characterization of chemical processes is an essential component of both industrial processes and fundamental studies. Applicable techniques abound, but optical spectroscopy has the unique combination of being easily incorporated into on-line (in-situ) monitoring probes and can also provide abundant chemical information (concentration, oxidation state, speciation). However, this abundance of chemical information can make applying optical spectroscopy to complex chemical processes challenging. This is particularly evident in the bulk electrolysis of U(VI) to U(IV), an essential preparatory step in some nuclear fuel recycling schemes. Starting and product materials have interfering spectral signatures in both electronic and vibrational spectroscopies, making accurate and real-time analysis difficult to achieve. In this paper, we discuss the application of optical spectroscopy to the on-line monitoring of a bulk electrolysis process and the methods utilized to analyze data as well as characterize the efficiency and mechanism of U(IV) generation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Growth and characterization of large (Y,La)TiO 3 and (Y,Ca)TiO 3 single crystals

The Mott-insulating rare-earth titanates ( R TiO 3 , with R being a rare-earth ion) are an important class of materials that encompasses interesting spin-orbital phases as well as ferromagnet-antiferromagnet and insulator-metal transitions. The growth of these materials has been plagued by difficulties related to overoxidation, which arises from a strong tendency of Ti 3 + to oxidize to Ti 4 + . We describe our efforts to grow sizable single crystals of YTiO 3 , Y 1 - x La x TiO 3 ( x ≤ 0.25 ), and Y 1 - y Ca y TiO 3 ( y ≤ 0.35 ) with the optical traveling-solvent floating-zone technique. Finally, we present sample characterization via chemical composition analysis, magnetometry, charge transport, neutron scattering, x-ray absorption spectroscopy, and x-ray magnetic circular dichroism to understand macroscopic physical property variations associated with overoxidation. Furthermore, we demonstrate a good signal-to-noise ratio in inelastic magnetic neutron scattering measurements of spin-wave excitations. A superconducting impurity phase, found to appear in Ca-doped samples at high doping levels, is identified as TiO.

36 MATERIALS SCIENCE↗

Arrays of glass wedges for multi-dimensional optical diagnostics

There is a common need in the advancement of optical diagnostic techniques to increase the dimensionality of measurements. For example, point measurements could be improved to multi-point, line, planar, volumetric, or time-resolved volumetric measurements. In this work, a unique optical element is presented to enable multi-dimensional measurements, namely, an array of glass wedges. A light source is passed through the wedges, and different portions of the illumination are refracted by different amounts depending on the glass wedge angle. Subsequent optics can be used to focus the light to multiple points, lines, or planes. Basic characterization of a glass wedge array is presented. Additional wedge-array configurations are discussed, including the use of a periodic intensity mask for multi-planar measurements via structured illumination. The utility of this optical element is briefly demonstrated in (a) multi-planar flame particulate measurements, (b) multi-point femtosecond-laser electronic excitation tagging for flow velocimetry, and (c) multi-line nitric oxide molecular tagging velocimetry in a hypersonic shock-tunnel. One significant advantage of this optical component is its compatibility with high-energy laser sources, which may be a limiting factor with other beam-splitting or beam-forming elements such as some diffractive optics. Additionally, an array of glass wedges is simple and easily customizable compared to other methods for forming multiple closely spaced illumination patterns. In conclusion, suggestions for further development and applications are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of suspended membrane waveguides towards a photonic atom trap integrated platform

We demonstrate an optical waveguide device, capable of supporting the high, in-vacuum, optical power necessary for trapping a single atom or a cold atom ensemble with evanescent fields. Our photonic integrated platform, with suspended membrane waveguides, successfully manages optical powers of 6 mW (500 μ m span) to nearly 30 mW (125 μ m span) over an un-tethered waveguide span. This platform is compatible with laser cooling and magneto-optical traps (MOTs) in the vicinity of the suspended waveguide, called the membrane MOT and the needle MOT, a key ingredient for efficient trap loading. We evaluate two novel designs that explore critical thermal management features that enable this large power handling. This work represents a significant step toward an integrated platform for coupling neutral atom quantum systems to photonic and electronic integrated circuits on silicon.

36 MATERIALS SCIENCE↗

Quantum Instrumentation Control Kit Defect Arbitrary Waveform Generator (QICKDAWG) v.0

SAND2024-08598O The Quantum Instrumentation Control Kit Defect Arbitrary Waveform Generator (QICKDAWG) characterizes nitrogen-vacancy centers in diamond and other defects. It does this by using a radio frequency system-on-a-chip (RFSoC) field programmable gate array (FPGA). QICKDAWG synthesizes microwave pulses from the RFSoC to change the spin state of the defects. The software also allows for laser control using the RFSoC, which optically pumps defects. Ultimately, QICKDAWG supports the implementation of RFSoC FPGAs in defect characterization. This replaces the slow, expensive, traditional hardware, thus lowering the cost and time for defect characterization. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

SciDAC↗

Hydraulic fracture characterization by integrating multidisciplinary data from the Hydraulic Fracturing Test Site 2 (HFTS-2)

Various technologies have traditionally been used to monitor and describe hydraulic fractures from different perspectives. This work demonstrates the value of data integration for hydraulic fracture characterization when multiple data resources are available. The Hydraulic Fracturing Test Site 2 (HFTS 2) is a hydraulic fracturing research project in the Delaware Basin with multiple surveillance techniques including fiber optics sensing, microseismic, pressure/temperature gauges, etc. We integrated the multidisciplinary data from the HFTS-2 to characterize hydraulic fractures. The integrated data revealed interesting fracture propagation features including layering, vertical propagation affected by pore pressure gradient, and different microseismic activities due to difference in-situ conditions. Furthermore, these findings can be insightful for understanding hydraulic fracture propagation. The comparison among multiple surveillance data also helps us to evaluate the roles of various surveillance technologies and provides us experience to make informative decisions depending on different monitoring objectives.

58 GEOSCIENCES↗

Protective effects of intravitreal administration of mesenchymal stem cell-derived exosomes in an experimental model of optic nerve injury

Traumatic optic neuropathy results in the loss of retinal ganglion cells (RGCs), leading to unavoidable visual impairment. However, there is no effective therapy by far. Accumulated studies support the perception that mesenchymal stem cells (MSCs) secrete exosomes that serve as a protective paracrine factor. The study aimed to explore and evaluate the potential therapeutic effects of intravitreal transplantation of MSC-derived exosomes (MSC-exos) in an experimental model of optic nerve crush (ONC). Exosomes were isolated from rat MSCs and characterized by transmission electron microscope and western blotting. At the onset of ONC, a single intravitreal injection of exosomes or PBS was administered to the rats. At day 30, hematoxylin and eosin staining, immunohistochemistry, and βIII-tubulin staining were performed to evaluate the survival of RGCs. Moreover, TUNEL assay was used to examine the apoptosis of RGCs. Inflammation-relevant factors were identified via quantitative polymerase chain reaction. The expression levels of cell apoptosis-related molecules and key members of the PI3K/AKT signaling pathway were determined via western blot analysis. We found that MSC-exos exhibited typical characteristic morphologies (cup-shaped) and sizes (peak size of 93 nm). Furthermore, they exhibited substantial expression of the exosome markers CD63 and TSG101, but lacked the expression of the cellular marker GM130. Treatment with intravitreal MSC-exos notably promoted the survival of RGCs in ONC rats. The level of pro-inflammatory cytokines, including TNF-α, IL-1β, IL-6, IL-8, and MCP-1, were reduced, whereas those of the anti-inflammatory factor IL-10 were increased. Moreover, the apoptosis induced by ONC was decreased by the administration of MSC-exos via upregulation of the Bcl-2/Bax ratio and downregulation of caspase-3 activity. Furthermore, MSC-exos significantly stimulated AKT phosphorylation, whereas LY294002 restored the apoptosis-preventing effects of MSC-exos. The results of our results demonstrated that intravitreal administration of MSC-exos ameliorates ONC-induced injury in a rat model. These findings might aid in the development of effective exosome-based therapeutic strategies for the treatment of optic nerve degeneration.

60 APPLIED LIFE SCIENCES↗

Measuring an ultrashort, ultraviolet pulse in a slowly responding, absorbing medium

Frequency-resolved optical gating (FROG) is a common technique for measuring ultrashort laser pulses using an instantaneous, nonlinear-optical interaction as a fast time-gate to measure the pulse intensity and phase. But at high frequencies, materials are often absorbing and it is not always possible to find a medium with a fast nonlinear-optical response. Here we show that an ultrashort, ultraviolet (UV) pulse can be measured in a strongly absorbing medium, using the absorption as the nonlinear-optical time-gate. To do this, we build on our recent implementation of FROG, known as induced-grating cross-correlation FROG (IG XFROG), where an unknown, higher-frequency pulse creates a transient grating that is probed with a lower-frequency, more easily detectable reference pulse. We demonstrate this with an 800 nm reference pulse to characterize 400 nm or 267 nm pulses using ZnS as the nonlinear-optical medium, which is absorptive at and below 400 nm. By scanning the delay between the two UV pulses which create the transient grating, we show that the phase-sensitive instantaneous four-wave-mixing contribution to the nonlinear signal field can be detected and separated from the slower, incoherent part of the response. Measuring a spectrally-resolved cross-correlation in this way and then applying a simple model for the response of the medium, we show that a modified generalized projections (GP) phase-retrieval algorithm can be used to extract the pulse amplitude and phase. We test this approach by measuring chirped UV pulses centered at 400 nm and 267 nm. Since interband absorption (or even photoionization) is not strongly wavelength-dependent, we expect IG XFROG to be applicable deeper into the UV.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-speed particle analysis using forward and backward two-dimensional angular optical scattering

Measurement of two-dimensional angle-resolved optical scattering (TAOS) patterns is an attractive technique for detecting and characterizing micron-sized high-speed flying particles. The elastic-scattering intensity pattern from a single particle as a function of spherical coordinate angles θ and ϕ provides detailed information on the particle’s morphology. By use of an ellipsoidal reflector and a high-speed CCD camera, scattering from a CW-laser was detected and resolved over a large angular range (θ from 12° to 168° and ϕ from 0° to 360°) from spherically shaped particles (e.g., amorphous silica and borosilicate glass) flowing through the reflector’s focal plane at speeds of 20 to 30 m/s. The scattering pattern from individual particles flying through the focal plane of the ellipsoid mirror provides insights about a particle’s size, clustering, roughness, and velocity.

Optics and optical instruments↗

Determining the complex second-order optical susceptibility in macroscale van der Waals heterobilayers

In this work, we report on the experimental characterization of the second-order susceptibility in MoSe 2 /WS 2 heterobilayers, including their hidden complex phases. To this end, we developed a heterodyne-detection scheme for second-harmonic generation and applied it to macroscale heterobilayer samples prepared using the gold-tape exfoliation method. The heterodyne scheme enabled us to distinguish the relative orientation of the crystal domains, and furthermore, it allowed us to characterize the complex phases of the susceptibility relative to a reference quartz sample. By comparing the results from the monolayer regions and the heterobilayer region over several hundred microns of the sample area, we determined that the contribution of interlayer effects to second-harmonic generation is within the experimental uncertainty arising from the sample inhomogeneity. The results here provide fundamental quantitative information necessary for the precise design of nanophotonic systems based on stacking engineering.

2D materials↗

Improvement in the spatial resolution of heavy ion beam probe measurements through application of ion optics

A technique for more accurately modeling and improving the spatial resolution of heavy ion beam probe measurements is described. We use a set of particle trajectories to numerically determine the focusing properties of a complicated three-dimensional magnetic field and characterize those properties with a transfer matrix. We then modify the transfer matrix approach of traditional ion optics to include a parameter that describes the ionization location of the detected ions. The ion optics model calculated using this technique enables a more accurate description of the particle trajectories than previously feasible. The model also allows one to easily determine an initial beam focus that could be used during experimental operation to optimize the spatial resolution of measurements. The technique has been applied to the design of a heavy ion beam probe diagnostic for the Wendelstein 7-X stellarator and improvements in the modeled spatial resolution by a factor of about 2 over previous estimates are possible. As a result, the improved spatial resolution will enable measurements of plasma fluctuations with smaller wavelengths than would otherwise be possible.

43 PARTICLE ACCELERATORS↗

Expanding the chemistry of borates with functional [BO 2 ]- anions

More than 3900 crystalline borates, including borate minerals and synthetic inorganic borates, in addition to a wealth of industrially-important boron-containing glasses, have been discovered and characterized. Of these compounds, 99.9 % contain only the traditional triangular BO 3 and tetrahedral BO 4 units, which polymerize into superstructural motifs. Herein, a mixed metal K 5 Ba 2 (B 10 O 17 ) 2 (BO 2 ) with linear BO 2 structural units was obtained, pushing the boundaries of structural diversity and providing a direct strategy toward the maximum thresholds of birefringence for optical materials design. 11 B solid-state nuclear magnetic resonance (NMR) is a ubiquitous tool in the study of glasses and optical materials; here, density functional theory-based NMR crystallography guided the direct characterization of BO 2 structural units. The full anisotropic shift and quadrupolar tensors of linear BO 2 were extracted from K 5 Ba 2 (B 10 O 17 ) 2 (BO 2 ) containing BO 2 , BO 3 , and BO 4 and serve as guides to the identification of this powerful moiety in future and, potentially, previously-characterized borate minerals, ceramics, and glasses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monolithic Spatial Heterodyne Raman Spectrometers (mSHRS): Toward highly miniature chemical sensors for deployment on moving platforms (Final Report, Phase I)

This report covers phase 1 (year 1) of the mSHRS project. Our ultimate long-term goal is to develop highly miniature Raman analyzers, known as spatial heterodyne Raman spectrometers (SHRS), that are deployable as in-situ chemical sensors on moving platforms. During Phase I (FY19/20) funding, our team focused our efforts solely on the key innovation needed toward realizing that goal: the development of the monolithic interferometer comprising the beam splitter and gratings with the appropriate design parameters and tolerances to enable Raman interferometry. We successfully developed and characterized the performance of the first monolithic SHRS devices including a monolithic version that incorporates field-widened optics. Our solid-state design approach integrated all optical components as a single monolithic unit for maintaining precise optical alignment during sensor operation, a requirement for operating in a vibration prone environment. This project has two principle activities: (1) Design and fabricate monolithic SHRS devices (i.e. monolithic device task) and (2) characterize the mSHRS devices in terms of performance (i.e. the Monolithic SHRS characterization task).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Novel Technique for Distributed Measuring of Strain in the Vadose Zone

Characterizing water content and pressure changes in the vadose zone is important to understanding a variety of geologic processes, ranging from permeability, to evapotranspiration, and aquifer recharge. Changes in water content, or pressure, cause strain in the solid porous medium of the vadose zone, and it is possible that measuring those strains could be used a characterization tool. The Coherence-length-gated Microwave Photonics Interferometry (CMPI) technique measures strain at high resolution along many intervals defined by pairs of reflectors distributed along an optical fiber. This technique has recently been developed at Clemson University, and it has the spatial, and temporal resolution to characterize the strains that are expected to occur with hydrologic changes in the vadose zone. However, the technique has never been used to measure strain in porous media, so its capabilities remain uncertain. The objective of this thesis is to evaluate the ability of using CMPI to measure strain changes in the vadose zone. The research approach consists of conducting laboratory tests using a column filled with sand that was subjected to changes in water content and pressure. An optical fiber with CMPI reflectors was deployed in a high surface area ribbon and used to measure strain along the axis of the column. The column was made from 8-inch, Schedule 40 PVC pipe (75 cm tall, 20 cm inner diameter) and filled with medium-grained sand (K = 2.5x10-6 m/s, porosity = 0.28, Coefficient of Uniformity = 2, van Genuchten (n = 4.34 and  = 0.00039 m-1), Young’s Modulus = 18 – 47 MPa). Five pressure and four temperature sensors attached to probes inserted into the wall. The optical fiber includes five reflectors spaced 10 cm apart on the inside and outside of the column along the vertical axis. Strain measurements are made between pairs of reflectors. The reflectors are created in 250-micron-diameter acrylate-coated single mode Corning SMF28e+ optical fiber using a femtosecond laser. The optical fiber was laminated between two pieces of polyester film creating a large surface area to transfer strain from the porous media to the optical fiber. The experiments were conducted by filling the column from the bottom or infiltrating water from the top. The water was allowed to equilibrate to room temperature prior to each test in order to limit thermoelastic strain. Five injection tests with a rate of 250 ml/min and three infiltration tests at varying rates were conducted, and the results show patterns of strain and pressure are generally similar. Hydrologic conditions define three zones based on the pressure magnitude and distribution. 1.) Ambient Zone where the pressure heads are quasi-static and the pressure gradient is roughly unity (head gradient of zero). This is the uppermost zone and is characterized by negative pressures. 2.) Transition Zone where the pressures increase from ambient to zero, are changing relatively rapidly and the pressure gradient is relatively steep (pressure head gradients of 2). The Transition zone is 10 to 15 cm thick. 3.) Positive Pressure Zone where the pressure is positive, the rate of change is slower than in the transition zone and the gradient is flatter (pressure head gradient 1.1 to 1.2). This is the lowest zone in the column. Injection of water causes the pressure to increase and the three zones to move upward. The Transition zone moves at a rate of approximately 0.0002 m/s +/- .00005, according to analyses of pressure profiles. This is the same as the average velocity of the water calculated as volumetric flux/effective porosity =5.4x10-5 m/s/0.28. Strain signals in the range of 10s  were observed with a noise level of generally less than 0.1  (signal to noise ratio of greater than 100) during injection and drainage. The spatial and temporal distributions of strain caused by injection depend on the location of the moving pressure zones. The locations of the different pressure zones were determined from pressure profiles at different times and these data were transferred to strain time series. This showed that strain in the Ambient pressure zone is either unchanged or slightly compressive, whereas strain in Transition zone is tensile and roughly proportional to the pressure change, and strain ranges from tensile to compressive in the Positive Pressure zone. In general, the strain is variable at the top of the Positive Pressure zone, but it appears to be consistently tensile lower in the zone. The spatial distribution of strain causes three distinct stages in the strain times series measured between pairs of CMPI reflectors. The strain is unchanged or slightly compressive during Stage 1, it increases (positive strain is tensile) approximately linearly at a rate of 0.02 to 0.03 μ/s during the Stage 2, and then flattens out in Stage 3. The strain increases again during Stage 4 of the time series. The pressure also changes in stages. It is unchanged during Stage 1 and then increases relatively rapidly at a rate of between 4 and 10 Pa/s during Stage 2 and continues to increase during Stages 3 and 4, but at a rate slightly slower than during Stage 2 (from 2.5 to 3.5 Pa/s). The rates of pressure and strain change are consistent with basic analyses. The rate of pressurization is similar to the calculated velocity of flow in the saturated zone, and this is similar to the measured velocity of the strain increase. The ratio of the pressurization rate and strain rate during Stage 2 (2.5 (Pa/s) /0.03 (μ/s)) is 80 MPa, which is approximately equal to the upper range expected considering the uniaxial compression and the Young’s Modulus of the sand. An interesting effect occurs when the upper surface of the sand becomes saturated. Significant compression (several 10s of ) occurs as the pressure and saturation increase at the upper surface. Compression occurs throughout the column, but the effect is greatest at the top of the column. The rate of compression is fastest slightly before ponding occurs, but it slows markedly and nearly stops when water starts to accumulate at the surface (ponding). This effect reverses when the surface of the sand is drained, resulting in tension throughout the column. The compression caused by this effect can be as large or larger than the tensile strain that accumulated during filling. This effect was unexpected because increasing pressure is normally associated with tensile strain. Nevertheless, this effect was observed consistently in all tests where the pressure changes at the upper surface, including tests where water was injected from below or infiltrated from above. This effect behaves as if the pore pressure at the upper surface of the sand exerts a normal force on the boundary (increasing pore pressure exerts a downward compression on the boundary). The results of these laboratory experiments indicate that CMPI can measure strain caused by fluid pressure changes in the vadose zone with a signal to noise ratio of 100 or more. Injection and drainage cause a strain signal that is complex, but repeatable. The magnitudes of the strain signal are consistent with magnitudes that are expected based on poroelastic calculations using independently measured properties of the sand. These results indicate that the CMPI technique with an optical fiber laminated in a polyester ribbon generates data that represent the strain distribution during hydrologic processes of imbibition and drainage in variably saturated sand. This suggests that distributed strain measurements using CMPI could be a viable approach for evaluating processes in the vadose zone, laying the groundwork for future field implementation.

47 OTHER INSTRUMENTATION↗

Rapid Accumulation of Soil Inorganics on Plastics: Implications for Plastic Degradation and Contaminant Fate

As plastics degrade in the environment, chemical oxidation of the plastic surface enables inorganics to adsorb and form inorganic coatings, likely through a combination of adsorption of minerals and in situ mineral formation. The presence of inorganic coatings on aged plastics has negative implications for plastics fate, hindering our ability to recycle weathered plastics and increasing the potential for plastics to adsorb contaminants. Here, inorganic coatings formed on terrestrially weathered polyethylene were characterized using synchrotron spectroscopy and microscopy techniques across spatial scales including optical microscopy, nano-X-ray-fluorescence mapping (nano-XRF), nano-X-ray absorption near edge structure (nano-XANES), and high-energy resolution fluorescence detected-XANES (HERFD-XANES). Results indicate a heterogeneous elemental distribution and speciation which includes inorganics common to soil terrestrial environments including iron oxides and oxyhydroxides, aluminosilicates, and carbonates.

36 MATERIALS SCIENCE↗

Ultrafast Optical Nanoscopy of Carrier Dynamics in Silicon Nanowires

Carrier distribution and dynamics in semiconductor materials often govern their physical properties that are critical to functionalities and performance in industrial applications. The continued miniaturization of electronic and photonic devices calls for tools to probe carrier behavior in semiconductors simultaneously at the picosecond time and nanometer length scales. Here, in this paper, we report pump–probe optical nanoscopy in the visible-near-infrared spectral region to characterize the carrier dynamics in silicon nanostructures. By coupling experiments with the point-dipole model, we resolve the size-dependent photoexcited carrier lifetime in individual silicon nanowires. We further demonstrate local carrier decay time mapping in silicon nanostructures with a sub-50 nm spatial resolution. Our study enables the nanoimaging of ultrafast carrier kinetics, which will find promising applications in the future design of a broad range of electronic, photonic, and optoelectronic devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗