Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Realizing efficient operations of Ni-cermet-based fuel cells on hydrocarbons via an in situ self-assembled metal/oxide nano-heterostructured catalyst

Operating Ni-cermet-based fuel cells on hydrocarbons is charming by largely hindered by poor coking tolerance and severe deterioration. Here, in this study, we report an effective metal/oxide nano-heterostructured catalyst with a nominal composition of Pr 0.95 Ru 0.05 O 2-δ (PRO), which is in situ self-assembled to a Pr 0.95 Ru 0.05-x O 2-δ oxide frame coated with Ru metallic nanoparticles (denoted as Ru/PRO) under the operation condition. When applied to the Ni-cermet (Ni-YSZ) anodes, the cells achieve decent peak power densities of 1.784 and 1.870 W cm -2 on CH 4 and C 3 H 8 with only 3% H 2 O at 750 °C, respectively. Moreover, the cells with Ru/PRO-coated anode demonstrate excellent durability when operated on CH 4 for ~ 220 h and C 3 H 8 for ~115 h. It is demonstrated that the Ru/PRO generates hydroxyl species that react with carbon species, followed by the formation of COH intermediates on Ni anode surfaces for removing the coking, as confirmed by experiments and computations.

30 DIRECT ENERGY CONVERSION↗

Integrating renewable energy into mining operations: Opportunities, challenges, and enabling approaches

Mining is one of the most energy-intensive industries worldwide. It also provides a critical source of raw materials for the manufacturing, transportation, construction, and energy sectors. Demand for raw materials is projected to increase as the world population grows and many low-income economies become middle-income countries. This growth in mineral demand, coupled with falling mineral ore grade, will likely increase the mining industry’s energy demand, used for activities across exploration, extraction, beneficiation and processing, and refining. At the time of this writing, mine operations are – due to their remoteness – dependent on fossil fuels such as diesel, heavy oils, and coal. In principle, mining could use energy recovery, renewable energy, and carbon capture to supplement, replace, or mitigate the impacts of fossil fuel use. However, a combination of renewable-energy technologies would be required. We explore challenges, opportunities, and enabling approaches to integrate renewable energy technologies into mining operations by examining the literature, including academic work, technical reports, and data produced by international agencies. Here, we find that despite numerous opportunities, technical issues still need to be considered, but solutions can tailor renewables to the mining industry. Further research should focus on identifying specific opportunities, technologies, and implementation strategies across the value chain of a variety of minerals with similar operational procedures.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Heterogeneity or illusion? Track the carbon Kuznets curve of global residential building operations

Residential buildings, the “last mile” sector in the global decarbonization, have become the most significant uncertain factor hindering carbon neutrality with increasing household energy demand. To track the operational carbon in buildings, this study investigates the carbon Kuznets curve (CKC) and the corresponding decoupling status of residential building operations at four emission scales by using the data of 30 countries from 2000 to 2019. The results show that (1) the CKC model can fit more than half of the samples. Most curves have an inverted U-shape, with 76% of emission per household and 82% of total emissions. (2) In the presence of the CKC, over four-fifths of global residential buildings peak regardless of any emission scale. The analysis denotes that the carbon emissions of developed countries reach their peaks earlier. In the total emissions, the samples’ peaking proportion is 20% and 25% with income per capita < 20,000 United States dollars (USD) and 20,000–40,000 USD, respectively. (3) The Tapio decoupling analysis and the threshold regression effectively verify the robustness and the heterogeneity of CKCs, respectively. Strong decoupling effects of CKCs in most countries are demonstrated at the scales of emission per floor space and the total emissions, and the heterogeneity proves the classic inverted U-shaped relationship between economy and emissions doesn’t exist in all emitters. Overall, this study tracks the historical carbon emission trajectories of residential building operations at a global scale, providing reference for different economies to simulate the dynamic of building carbon emissions along with the economic booming.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operator learning for energy-efficient building ventilation control with computational fluid dynamics simulation of a real-world classroom

Energy-efficient ventilation control plays an important role in reducing building energy consumption while ensuring occupant health and comfort. While Computational Fluid Dynamics (CFD) simulations provide detailed and physically accurate representations of indoor airflow, their high computational cost limits their use in real-time building control. In this work, we present a neural operator learning framework that combines the physical accuracy of CFD with the computational efficiency of machine learning to enable building ventilation control with the high-fidelity fluid dynamics models. Our method jointly optimizes the airflow supply rates and vent angles to reduce energy use and adhere to air quality constraints. We train an ensemble of neural operator transformer models to learn the mapping from building control actions to airflow fields using high-resolution CFD data. This learned neural operator is then embedded in an optimization-based control framework for building ventilation control. Experimental results show that our approach achieves significant energy savings compared to maximum airflow rate control, rule-based control, as well as data-driven control methods using spatially averaged CO 2 prediction and deep learning–based reduced-order models, while consistently maintaining safe indoor air quality. These results highlight the practicality and scalability of our method in maintaining energy efficiency and indoor air quality in real-world buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microbial electrolysis cell recovery after inducing operational failure conditions

Microbial Electrolysis Cells (MECs) are often documented for their ability to produce hydrogen through new sources and new configurations. However, few studies attempt to document the recovery of the bioanode after being exposed to operational failure conditions. This study attempted to compare the behavior and recovery of MECs after being exposed to four operational failure conditions: acidification, aeration, osmotic shock, and voltage reversal. For each failure condition, three time points were tested: before failure, immediately after failure, and after recovery efforts. Of the modes tested, acidification caused the largest loss in performance and operational efficiency, while osmotic shock caused the second largest loss in performance. Aeration and voltage reversal caused negligible losses in performance immediately after failure conditions and after the recovery period. Aeration and voltage reversal had a minimal effect on the removal of individual compounds. However, acetate accumulated after acidification, and propionic acid accumulated after osmotic shock. Furthermore these findings could be useful for determining if failure will require more significant repair efforts in commercially deployed devices. While acidification created permanent losses to performance, if device failures like aeration, osmotic shock, and voltage reversal are caught early (less than 15 min), full recovery without bioanode replacement is likely.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comprehensive Analysis of Model Parameter Uncertainty Influence on Evaluation of HVAC Operation to Mitigate Indoor Virus: A Case Study for an Office Building in a Cold and Dry Climate

Simulation-based studies of HVAC operation to mitigate indoor virus have been conducted to understand tradeoffs between indoor air quality (IAQ) and energy consumption. However, the influence of model parameter uncertainty in these studies has not been systematically quantified, which is critical when providing guidance to building operators. To address this gap, we identify 20 model parameters for a typical medium office building system in a cold and dry climate that can influence IAQ and energy consumption for indoor virus scenarios. Next, the distributions of the parameter values are estimated from literature and a set of simulation samples for three representative days is generated that simultaneously sample all of the parameters from their distributions. Two HVAC virus mitigation strategies are studied: increased filtration using MERV 13 filters and increased ventilation, via supply of 100% outdoor air into buildings. The model parameter uncertainty leads to significant variability in the results, particularly for the IAQ because of the highly uncertain virus generation rate. Use of 100% outdoor air can be beneficial for some uncertain scenarios on the hot day, but shows less IAQ improvement and/or significant energy increases on the other days. The virus removal efficiency and pressure drop of the HVAC filter, fan efficiency, and internal heat gain are the most important parameters to determining the tradeoffs of the two strategies. Our results demonstrate how this model parameter uncertainty analysis methodology can provide practical guidance to building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing the design and operation of water networks: Two decomposition approaches

We consider the design and operation of water networks simultaneously. Water network problems can be divided into two categories: the design problem and the operation problem. The design problem involves determining the appropriate pipe sizing and placements of pump stations, while the operation problem involves scheduling pump stations over multiple time periods to account for changes in supply and demand. Our focus is on networks that involve water co-produced with oil and gas. While solving the optimization formulation for such networks, we found that obtaining a primal (feasible) solution is more challenging than obtaining dual bounds using off-the-shelf mixed-integer nonlinear programming solvers. Therefore, we propose two methods to obtain good primal solutions. One method involves a decomposition framework that utilizes a convex reformulation, while the other is based on time decomposition. To test our proposed methods, we conduct computational experiments on a network derived from the PARETO case study.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparative Analysis of Model Predictive Control and MPC-Informed Rule-Based Control for Thermal Storage Operation in Ultra-Low Temperature 4th Generation District Heating Networks

The integration of thermal storage and heat pumps in district heating networks (DHNs) can significantly enhance operational flexibility and energy efficiency; however, the practical deployment of advanced control strategies is often hindered by forecasting requirements and computational complexity. This study presents a comparative analysis of thermal storage control strategies in an ultra-low-temperature fourth-generation DHN, focusing on the development of a simplified rule-based control (RBC) explicitly informed by Model Predictive Control (MPC) behavior. The proposed methodology systematically analyzes the charging and discharging decisions of an MPC-controlled system under ideal forecasting conditions and extracts recurrent control patterns as a function of key system variables, including outdoor temperature, thermal demand, and electricity price. These patterns are translated into a set of structured time- and condition-based rules, resulting in an MPC-informed RBC that embeds predictive insights while preserving implementation simplicity and operational transparency. The approach is validated on a realistic mixed-use urban district in Denver, Colorado, USA, equipped with a centralized air-source heat pump, distributed water-to-water heat pumps, and a central thermal storage unit. Results show that the tuned RBC attains approximately 96% of ideal MPC economic performance (-27% of costs), preserves values of technical and environmental indicators (reduction only of 2-3%), and substantially reduces complexity. Sensitivity analyses further demonstrate the robustness of the RBC under varying operational conditions (i.e., ambient temperature, electricity price). Overall, the study demonstrates that MPC-informed rule-based control represents an effective trade-off between control performance and real-world applicability, enabling the integration of additional system components while maintaining simplicity, robustness, and ease of implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On the operational characteristics and economic value of pumped thermal energy storage

Pumped thermal energy storage (PTES) systems use an electrically-driven heat pump to store electricity in the form of thermal energy, and subsequently dispatch the stored thermal energy to generate electricity using a thermodynamic heat engine. Optimal day-ahead operational scheduling and annual value of a PTES system based on Joule-Brayton thermodynamic cycles and two-tank molten salt hot thermal storage is evaluated in this work. Production cost models, which simultaneously optimize commitment and dispatch schedules for an entire set of generators to minimize the cost of satisfying electricity demand, are employed to determine system-optimal operation and day-ahead energy value of the PTES system within each of six hypothetical near-future grid scenarios intended to approximately represent the U.S. Western Interconnection or the Texas Interconnection. Sensitivity to grid scenario (including the contribution of variable renewable energy sources), thermal storage capacity, relative heat pump and heat engine capacities, and startup/shutdown cycling costs are evaluated. PTES energy value and heat engine annual capacity factor increase strongly as the contribution of variable renewable resources increases, heat pump capacity increases relative to heat engine capacity, or PTES cycling costs decrease. Grid scenarios in which the contribution of variable renewable energy is dominated by solar photovoltaics (PV) vs. wind produce inherently different PTES operational patterns. Annual PTES energy value within PV-dominated scenarios increased with storage capacity only up to approximately seven hours of full-load discharge capacity, whereas that within wind-dominated scenarios exhibited a continual increase with storage duration up to at least 16 hours.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing heat pump water heater performance with embedded phase change materials thermal energy storage: First hour rating improvement and demand response operation

The increasing global emphasis on energy efficiency and sustainability has put heat pump water heaters (HPWHs) in the spotlight as an energy-efficient alternative to traditional water heating systems. However, their widespread adoption is limited by challenges such as insufficient First Hour Rating (FHR), suboptimal control mechanisms, and limited flexibility for demand response operations. Here, to address these limitations, this study proposes an innovative HPWH system integrated with embedded phase change material (PCM)-based thermal energy storage (TES). The research introduces a novel design and control strategy that leverages optimized PCM integration to enhance thermal storage capacity, improve hot water delivery during peak demand, and increase load-shifting potential. A combination of system modeling, performance simulation, and demand response control strategy evaluation was employed to quantify the benefits of PCM integration. Results demonstrate that the proposed PCM-TES HPWH system significantly enhances FHR, with an optimal 7.0 lb. of PCM increasing FHR by over 26 %—from 62 to 78 gal—for a standard 50-gal HPWH. Additionally, under advanced demand response operation using a preheat strategy, the system reduces the percentage of control temperature out-of-band time from 65 % (conventional HPWH) to just 11.6 %, enabling a more stable and efficient hot water supply. This research contributes a novel PCM-embedded HPWH design and control framework that addresses both performance and grid-interactivity challenges. The findings offer a viable pathway to enhancing the operational efficiency, flexibility, and grid responsiveness of residential water heating systems.

Demand response control↗

The impact of fuel and injection strategy on combustion characteristics, emissions and efficiency in gasoline compression ignition operation

Gasoline compression ignition in diesel engines has been proposed in order to meet increasingly stringent emission regulations without sacrificing efficiency. In this study, a six-cylinder heavy-duty diesel engine was operated in a mixing controlled gasoline compression ignition mode to investigate the influence of fuels and injection strategies on the combustion characteristics, emissions, and thermal efficiencies. Fuels, including ethanol (E), isobutanol (IB), and diisobutylene (DIB), were blended with a gasoline fuel to form E10, E30, IB30, and DIB30 based on volumetric fraction. These four blends along with gasoline formed the five test fuels. With these fuels, three injections strategies were investigated, including late pilot injection, early pilot injection, and port fuel injection/direct injection. The impact of moderate exhaust gas recirculation on nitrogen oxides and soot emissions was examined to determine the most promising fuel/injection strategy for emissions reduction. In addition, first and second law analyses were performed to provide insights into the efficiency, loss, and exergy destruction of the various gasoline fuel blends at low and medium load conditions. Overall, the emission output, thermal efficiency, and combustion performances of the five fuels were found to be similar and their differences are modest under most test conditions. E30 with the port/direct fuel injection strategy obtained the peak brake thermal efficiency (46.9%) and gross indicated thermal efficiency (52.2%) at 14 bar. At 7 bar, the peak brake thermal efficiency (44.2%) and gross indicated thermal efficiency (52.5%) also belonged to E30 with the late pilot injection strategy. The second law analysis revealed that exergy destruction was mostly influenced by the fuel type and not by the injection strategy for the 14 bar operating conditions. However, the opposite trend was observed for the 7 bar case. In addition, port fuel injection in combination with oxygenated fuel blends was found to be helpful to suppress soot emissions for operation with exhaust gas recirculation.

co-optima fuels↗

First operation and validation of simulations for the divertor cryo-vacuum pump in Wendelstein 7-X

Ten cryo-vacuum pumps (CVPs) were installed in the subdivertor region of each island divertor in the stellarator Wendelstein 7-X (W7-X) and operated for the first time during the recently completed plasma campaign OP2.1. A pumping speed of 70 ± 1 $\frac{m^3}{s}$ was measured during dedicated tests with known hydrogen gas injection. Based on a conductance model, the estimated pumping speed ranges from 86-93 $\frac{m^3}{s}$ for different sticking coefficients between 0.6 and 0.8. After completion of the initial tests the CVPs were operated successfully throughout the campaign, with regeneration performed once a week. Neutral gas pressures in the subdivertor in the range of 10 −4 mbar are well within the molecular flow regime and limit the particle exhaust capabilities of the CVPs. Simulations of the neutral gas pressure in the three-dimensional complex geometry of the subdivertor were performed using the DIVGAS code based on the direct simulation Monte Carlo method and a model implemented in the steady-state thermal package in ANSYS, which are in agreement with the measured values during plasma operation.

Cryo-vacuum pumping↗

Slot-die-coating operability windows for polymer electrolyte membrane fuel cell cathode catalyst layers

Roll-to-roll (R2R) slot-die coating of polymer electrolyte membrane fuel cell (PEMFC) catalyst layers represents a scalable deposition method for producing 10–20 m 2 ·min -1 of catalyst-coated gas diffusion layers (GDLs). This high-throughput production technique will help lower the cost of PEMFC catalyst layers. The uniformity of the wet layer applied by slot die deposition is affected by process parameters such as substrate speed, vacuum pressure applied at the upstream meniscus, gap between the slot die lips and substrate, ink rheology, and other ink and substrate properties. The set of conditions for producing a defect-free coating with a dilute ink typically requires little to no upstream vacuum pressure, so suitable operating conditions can be found easily through trial and error and operator intuition. However, the higher viscosity of more concentrated inks dramatically shifts the range of settings that result in a homogeneous coating to higher vacuum levels, which are harder to find through hit or miss. A predictive model showing the range of operable conditions decreases material wastage inherent in experimentally searching for suitable parameters. In this study, the defect-free coating parameter window is explored experimentally and theoretically for two concentrations of PEFC cathode inks. Both a full capillary hydrodynamic model and a computationally cheaper viscocapillary model successfully predict the experimentally determined coating window within the experimental and model uncertainty limits for inks with 5.3 wt% and 12.0 wt% solids ink while maintaining the 0.1 mg Pt ·cm -2 Pt areal loading target. Here, this paper demonstrates a viable pathway for meeting the $30/kW net ultimate cost target of the United States Department of Energy (U.S. DOE) Hydrogen Fuel Cells Technologies Office (HFTO). The concentrated ink lowers the thermal energy and capital expenditure (CapEx) budget of the coating process by decreasing the amount of time, energy, and floorspace required for drying the coating.

25 ENERGY STORAGE↗

Stability boundary and optimal operating parameter identification in milling using Bayesian learning

Here, this paper describes a novel Bayesian learning approach for stability boundary and optimal parameter identification in milling without the knowledge of the underlying tool dynamics or material cutting force coefficients. The paper is divided into two parts. First, a Bayesian learning method for stability lobe identification using test results is described. Each axial depth and spindle speed combination is characterized by a probability of stability which is updated using Bayes’ rule when a test result (stable or unstable) is made available. A novel likelihood function is defined which incorporates knowledge of the stability behavior. Numerical results show convergence to the analytical stability lobe diagram. Second, an adaptive experimental strategy to identify optimal operating parameters that maximize material removal rate is described. Numerical evaluation shows convergence to the optimal operating point with error less than 15 % within ten tests on average. The approach is validated using experimental results. Results show that the proposed method is an efficient and robust learning method to identify the stability lobe diagram and optimal operating parameters with a limited number of tests/data points.

Bayesian machine learning↗

Effect of Gd-doped ceria infiltration into Ni-YSZ on reversible solid oxide cell operation

Gadolinium doped ceria (GDC) infiltration into Ni-(Y 2 O 3 ) 0•08 (ZrO 2 ) 0.92 (Ni-YSZ) fuel electrodes has been shown to significantly improve solid oxide electrolysis cell performance and stability. However, the effects of GDC infiltration on cells operated reversibly between fuel cell and electrolysis modes have not been reported previously. Here we present reversible solid oxide cell life test results for different GDC infiltration loadings into Ni-YSZ electrodes in two types of fuel-electrode-supported solid oxide cells. Electrochemical impedance spectroscopy reveals that GDC infiltrant lowers the initial cell area specific resistance (ASR) and limits the degradation – for example, the GDC-infiltrated electrode ASR increased by 0.1 Ω cm 2 over 1000 h of reversible operation at ±0.5 A cm –2 and 800 °C, compared to 0.19 Ω cm 2 for non-infiltrated cells. Cell voltage degradation rates were reduced by infiltration during operation at a current density of ±0.5 A cm –2 at 800 °C, and during at 700 °C at ±0.75 A cm –2 . Furthermore, scanning electron microscopy observations show that the infiltrated GDC nanoparticles mitigate Ni particle coarsening in the Ni-YSZ electrode, possibly explaining the enhanced cell stability.

25 ENERGY STORAGE↗

Design and operating principles for high-performing anion exchange membrane water electrolyzers

Anion-exchange-membrane water electrolyzers (AEMWEs) provide a promising pathway to utilize low-carbon renewable electricity to produce clean hydrogen at high efficiency and purity, while maintaining low system costs compared to incumbent technologies. Though significant progress has been made in developing membranes and catalysts, AEMWEs still require better performance and durability to realize widespread deployment. Here, we overcome these challenges by decoupling anode and cathode polarization behavior via integration of a reference electrode in the membrane-electrode assembly. This measurement identified that the mass-transport losses dominate the cathode overpotential if feeding with electrolytes, while kinetic losses dominate the anode overpotential. These losses are mitigated by varying electrode properties and operating strategies, where a more hydrophobic, optimal loaded cathode, a high porosity anode, and operating with the cathode dry exhibited the best performance. These findings eventually enabled achieving a high-performing and durable complete PGM-free AEMWE operating at 1.5 Acm –2 for over 500h with negligible degradation, demonstrating significant progress for AEMWEs.

25 ENERGY STORAGE↗

A compact design for an electric driven hydraulic gear machine capable of multiple quadrant operation

This paper presents an innovative design of an integrated electro-hydraulic (EH) flow generation unit able to operate in multiple quadrants. The proposed unit is composed of a hydraulic machine which can operate in either pumping or motoring mode, and an electric machine, which can operate as electric motor or generator. The adopted morphological integration of the two unit fulfills the goals of maximizing compactness, power to weight ratio, energy efficiency and quietness. Furthermore, the design results from a numerical optimization procedure that includes detailed simulation of both the electric machine and the hydraulic machine, using simulation tools previously developed by the authors, but combined for the first time in this work. After describing the optimization procedure, the paper focuses on the design integration aspects of the novel unit. A 9 kW prototype of the integrated unit was also fabricated and tested to verify its performance. Tests results show a measured overall energy efficiency up to 69%, demonstrating the potentials of the proposed concept, despite some limitations present in the first prototypes which could be addressed in future design refinements.

42 ENGINEERING↗

Commissioning and operation in magnetic field of CMS GE1/1 station

In October and November 2021 the CMS Gas Electron Multiplier (GEM) detectors of station GE1/1 were operated for the first time in presence of a magnetic field in CMS. The phenomena observed in this first period led to performing a test on GE1/1 chambers to study their behaviour in presence of a magnetic field ramp. The magnetic field has been created using the Goliath magnet installed in the CERN North Area. In conclusion, the aim of the test is to determine if a magnetic field ramp causes serious problems to the operation of the GEM chambers and to develop a clear set of procedures, that will permit the safe operations of the GEM chambers during a magnetic field ramp.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗