Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operational analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Planning for the storm: Considering renewable energy for critical infrastructure resilience

This study uses the renewable energy optimization model to assess three critical facilities in North Carolina. Techno-economic results were then compared to analyses completed for critical facilities in California and New York to assess energy system cost effectiveness. Though solar photovoltaic (PV) arrays are cost-effective across each of the three North Carolina facilities, adopting battery storage to enable PV to operate with existing diesel generators in a hybrid energy system reduces the economic value of the system. This is in contrast to more economically viable systems in California and New York. All of these systems also offer unquantified resilience benefits by extending operation from hours to weeks across the facilities. If decision makers were able to value the resilience benefits offered by each system or utility rate structures were changed to incentivize battery storage during normal operations, it would impact these assessments. Even so, this analysis provides decision makers a key set of cost benchmarks when considering how they might improve resilience at their critical operations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Toward the first gluon parton distribution from the LaMET

Abstract We present progress towards the first unpolarized gluon quasi-parton distribution function (PDF) from lattice quantum chromodynamics using high-statistics measurements for hadrons at two valence pion masses M π ≈ 310 and 690 MeV computed on an a ≈ 0.12 fm ensemble with 2 + 1 + 1-flavors of highly improved staggered quark generated by the MILC collaboration. In this study, we consider two gluon operators for which the hybrid-ratio renormalization matching kernels have been recently derived and a third operator that has been used in prior pseudo-PDF studies of the gluon PDFs. We compare the matrix elements for each operator for both the nucleon and pion, at both pion masses, and using two gauge-smearing techniques. Focusing on the more phenomenologically studied nucleon gluon PDF, we compare the ratio and hybrid-ratio renormalized matrix elements at both pion masses and both smearings to those reconstructed from the nucleon gluon PDF from the CT18 global analysis. We identify the best choice of operator to study the gluon PDF and present the first gluon quasi-PDF under some caveats. Additionally, we explore the recent idea of Coulomb gauge fixing to improve signal at large Wilson-line displacement and find it could be a major help in improving the signal in the gluon matrix elements. This work helps identify the best operator for studying the gluon quasi-PDF, shows higher hadron boost momentum is needed to implement hybrid-ratio renormalization reliably, and suggests the need to study more diverse set of operators with their corresponding perturbative calculations for hybrid-ratio renormalization to further gluon quasi-PDF study.

Good, William (ORCID:0000000184281003)↗

Electrification of Airport Shuttle Operations

Fleet owners are increasingly looking to adopt electric vehicles, however careful consideration is needed to ensure electric vehicles can perform their duty without impacting operations. This work examines a fleet of 200 Dallas-Fort Worth airport shuttle buses to estimate the opportunity for vehicle electrification. Analysis suggests unique pathways to electrification for each mode of operation, and unique benefits and challenges whether they serve employee lots, rental car lots, remote lots, or aircraft hardstand operations. These analyses include daily energy consumption, charging opportunities; emissions impacts; and charging location potential using hotspot analysis. Results highlight the most promising candidates for electrification and provide pathways for future electrification.

ADVANCED PROPULSION SYSTEMS↗

Impact assessment of geomagnetic induced current neutral blocking devices with power electronics sources on distance relay for 230 kV transmission lines

Electrical grids increased the integration of power electronics sources onto transmission lines. In addition, recent reports show a significant rise in geomagnetic storms occurring in 2024. These geomagnetic storms can affect transmission lines by inducing electrical currents within them, potentially causing power outages due to overloaded power transformers. Geomagnetic induced current neutral blocking devices (GIC-NBDs) are capacitors on the ground of wye power transformers, to avoid damage caused by geomagnetic storms. The integration of distance relays and transmission lines with power electronics sources and GIC-NBDs needs to be studied to observe if GIC-NBDs and power electronics sources could adversely affect operation of the electrical grid. In this analysis, the effect of 2 MW power electronics sources and GIC-NBDs on distance relays is assessed for different 230 kV transmission line lengths in radial and nonradial power systems. The simulations measured the apparent impedances, with different electrical faults. Results for a typical 2,650 μF GIC-NBD application were presented on impedance plots, and the distance relay model operations were assessed. In conclusion, the tests for radial and nonradial power systems showed the behavior of the distance elements and source impedance ratios, assessing the effect of power electronics sources and GIC-NBDs on 230 kV transmission lines.

Distance relays↗

Current loss analysis in photoelectrochemical devices

Ongoing efforts to stabilize the operation of photoelectrochemical (PEC) devices remain critical for achieving economically viable solar fuel production, as devices with lifetimes on the order of 10 to 30 years are projected requirements for utility-scale, PEC device implementation. However, insight into the causes of device degradation and activity losses is generally provided by monitoring the device current, a quantity which masks the relative contributions of photovoltaic component degradation and electrocatalyst activity drops to overall performance losses. In this study, an approach for deconvoluting the various contributors to PEC device losses is described. In particular, the causes for observed fluctuations in device performance are determined through the collection of real-time, current–voltage data, paired with an analytical method that enables the decomposition of drops in device current into its constituent photovoltaic- and catalyst-driven performance losses. We test the validity of this approach by applying it to the data collected for a PEC hydrogen evolution test-bed.

14 SOLAR ENERGY↗

Using an Analytic-Based Magnetic Charge Fourier Series Model to Study a Magnetic Lead Screw when Operating as a Magnetic Spring

A magnetic charge field analysis approach is presented that models an array of magnets by using a magnetic vector Fourier series representation. Using a Fourier series function enables the magnets' relative permeability to be accounted for and also reduces the computational burden. The accuracy of the presented modelling approach is validated by studying the fields and forces created by a magnetic lead screw when acting as a magnetic spring

Kouhshahi, Mojtaba Bahrami↗

Criteria for Grid-Forming Inverters Transitioning Between Current Limiting Mode and Normal Operation

Here, this letter focuses on the fault recovery analysis of inverters using multi-loop droop based grid-forming control, taking into account different current limiting strategies. A criterion is proposed to determine when the inverter can exit the current limiting mode after fault clearance. The theoretical findings are verified through electromagnetic transient simulations using the direct (d)-axis priority-based current limiting method, circular current limiting method, and virtual impedance method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interconnection Cost Analysis in ISO-New England

Electric transmission system operators (ISOs, RTOs, or utilities) require new large generators seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. Berkeley Lab has collected interconnection cost data for 194 projects in New England from interconnection studies performed between 2010 and 2021. Project-level cost summary data are available for download on this page. We find: -Interconnection costs have grown over time, especially for projects that withdraw. -Interconnection costs are highest for onshore wind, followed by solar and storage. Natural gas and offshore wind projects tend to cost less to interconnect, in comparison. -Economies of scale exist for solar and possibly storage projects, but not for other resource types. -Wind and solar projects requesting capacity network resource interconnection service have higher interconnection costs, despite being evaluated using the same interconnection standard in the analyzed studies. -Low and high interconnection costs can be found throughout the ISO-NE footprint. -Costs are split fairly evenly between investments at the point of interconnection and within the broader network for active and withdrawn projects, while complete projects incur most costs at the point of interconnection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ANS Winter 2024 Summary: MCCAFE: The Monte Carlo Constructor for ATR Fuel Elements

The Irradiation Experiment Neutronics Analysis Department at Idaho National Laboratory (INL) has implemented a new analysis workflow for experiments in the Advanced Test Reactor (ATR). One key piece of this workflow is the Monte Carlo Constructor for ATR Fuel Elements, or MCCAFE. For each ATR operating cycle, the Reactor and Nuclear Safety Engineering (RNSE) Department first solves the core in eigenvalue mode and depletes the driver fuel materials. In a separate calculation, neutronics analysts model and deplete the materials of one or more irradiation experiments, usually in a series of fixed-source Monte Carlo N-Particle (MCNP) models of the ATR for neutron transport calculations. It was desirable to use the results of the former calculations to inform the models of the latter. MCCAFE is a Python program developed using American Society of Mechanical Engineers Nuclear Quality Assurance-1 procedures at INL. Its purpose is to take the calculated results from the RNSE depletion solutions and the measured or projected operating parameters from the Nuclear Data Management and Analysis System (NDMAS) to generate fixed-source models of the ATR core at given points in time across one or more cycles.

99 - GENERAL AND MISCELLANEOUS↗

Ensuring Solution Uniqueness in Three-Phase Power System State Estimation

This paper is concerned with the issue of potential non-unique solutions in three-phase state estimation. Theory of observability analysis for positive sequence power system state estimation is based on certain assumptions that avoid possibility of multiple solutions. Also, it is shown that observability of a positive sequence network remains independent of the network parameters or the operating state. When extending single-phase observability analysis directly to the three-phase case, this paper considers the possibility of converging to multiple solutions, i.e. solution non-uniqueness, even for cases where state estimator successfully converges. The study illustrates via numerical examples the likelihood of converging to entirely different solutions for certain network parameters. It also examines how the operating state, particularly under unbalanced loading, leads to solution non-uniqueness. The paper then describes an alternative approach to ensure a unique solution in three-phase state estimation. This method aims to accurately and uniquely estimate the state of any unbalanced three-phase system, irrespective of load imbalance, network configuration, existence of synchronous generators or transformers.

Power System State Estimation, Three-Phase, Distri↗

Near real-time streaming analysis of big fusion data

Experiments on fusion plasmas produce high-dimensional data time series with ever-increasing magnitude and velocity, but turn-around times for analysis of this data have not kept up. For example, many data analysis tasks are often performed in a manual, ad-hoc manner some time after an experiment. In this article, we introduce the Delta framework that facilitates near real-time streaming analysis of big and fast fusion data. By streaming measurement data from fusion experiments to a high-performance compute center, Delta allows computationally expensive data analysis tasks to be performed in between plasma pulses. This article describes the modular and expandable software architecture of Delta and presents performance benchmarks of individual components as well as of an example workflow. Focusing on a streaming analysis workflow where electron cyclotron emission imaging (ECEi) data is measured at KSTAR on the National Energy Research Scientific Computing Center's (NERSC's) supercomputer we routinely observe data transfer rates of about 4 Gigabit per second. In NERSC, a demanding turbulence analysis workflow effectively utilizes multiple nodes and graphical processing units and executes them in under 5 min. We further discuss how Delta uses modern database systems and container orchestration services to provide web-based real-time data visualization. For the case of ECEi data we demonstrate how data visualizations can be augmented with outputs from machine learning models. Here, by providing session leaders and physics operators, results of higher-order data analysis using live visualizations may make more informed decisions on how to configure the machine for the next shot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization-based technoeconomic comparison of multi-stage membrane distillation configurations for hypersaline produced water desalination

Unconventional oil and gas production raises concerns regarding sustainable management of high salinity wastewaters generated in this process. Membrane distillation (MD) is a thermal desalination process capable of treating hypersaline brines such as produced water. The low single pass recovery in MD systems operated in a single stage requires a large recycle stream to achieve the desired recovery, resulting in high energy consumption and operating cost. Multistage configurations in continuous recirculation operation mode offer the potential to reduce the energy intensity of MD systems. However, rigorous analysis is needed to assess the performance of MD configurations when operating in multi-stage mode. Here, we present an optimization-based comparison of economic and energetic performance for five configurations of MD (including DCMD, AGMD, PGMD, CGMD, and VMD) operating in multi-stage continuous recirculation mode. Our findings demonstrate that multistage operation reduces the treatment cost and energy intensity of all MD configurations compared to single stage MD, with the greatest benefit for VMD and PGMD. AGMD with five stages outperforms other configurations with 3.58 $/m 3 feed treatment cost, followed by VMD, CGMD, DCMD, and PGMD with 3.8, 4.2, 5.4, and 9.06$/m 3 feed treatment costs corresponding to twelve, eight, eight, and sixteen stages, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CFD-Guided Evaluation of Spark-Assisted Gasoline Compression Ignition for Cold Idle Operation

A closed-cycle, three-dimensional (3D) computational fluid dynamics (CFD) analysis campaign was conducted to evaluate the performance of using spark plugs to assist gasoline compression ignition (GCI) combustion during cold idle operations. A conventional spark plug using single-sided J-strap design was put at a location on the cylinder head to facilitate spray-guided spark assistance. Ignition was modeled with an L-type energy distribution to depict the breakdown and the arc-to-glow phases during the energy discharge process. Several key design parameters were investigated, including injector clocking, number of nozzle holes, spray inclusion angle, number of fuel injections, fuel split ratio, and fuel injection timings. The study emphasized the region around the spark gap, focusing on flame kernel formation and development and local equivalence ratio distribution. Flame kernel development and the ignition process were found to correlate strongly with the fuel stratification and the flow velocity near the spark gap. The analysis results showed that the flame kernel development followed the direction of the local flow field. In addition, the local fuel stratification notably influenced early-stage flame kernel development due to varying injection spray patterns and the fuel injection strategies. Among these design parameters, the number of nozzle holes and fuel injection timing had the most significant effects on the engine combustion performance.

42 ENGINEERING↗

PSA 2025 Presentation: "Modeling and Sensitivity Analysis of a Generation IV Pebble Bed Reactor Using MELCOR 2.2"

Accompanying the advancement of reactor technologies is the need for computational modeling and simulation to predict their behavior under normal operating conditions and accident scenarios. New Generation IV reactor designs which employ non-conventional fuel have a particular need for modeling the behavior and release of radionuclides and other material from the fuel. In this work, MELCOR version 2.2, a system-level safety and accident scenario code developed by Sandia National Laboratories, was used to model a 200-MWth pebble bed modular reactor and calculate the inventories of circulating and deposited graphite, metal dust, and elemental components released from the fuel elements. A base case modeling the reactor under standard operating conditions was calculated using MELCOR and the inventories were extrapolated to 30 years of operation time using a logarithmic regression fit. A sensitivity analysis was also performed in which several key parameters for the base case model were modified to explore the effect of these changes on the inventories calculated by MELCOR. A set of transient scenario simulations for a depressurized loss of forced cooling (DLOFC) accident were also performed. The results of the sensitivity analysis and transient simulations are reported and discussed in relation to the modeling techniques used for this study.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Chapter 8: Life-Cycle Testing and Analysis

Prior to a spacecraft launch, program mission assurance standards dictate that the flight battery power system should comply with mission requirements under the intended operating conditions. Ground life cycle testing (LCT) combined with an analysis on the electrical power system (EPS) battery is an empirical method used to demonstrate compliance to satellite service life requirements. The LCT compliance method adopted by the aerospace industry is based on demonstrating a space battery's life expectancy as a part of battery qualification. Real-time cell and lithium-ion battery (LIB) LCT data are commonly used for model inputs to EPS power and energy balance analyses, in LIB reliability analysis estimates, and to support on-orbit spacecraft mission life extension opportunities. This chapter describes the LCT planning steps, process approach, and analysis techniques commonly used to qualify space LIB power systems.

accelerated aging↗

ION Work Reduction Opportunity Realization Demonstration

The purpose of this research was to realize one of the advanced training work reduction opportunities first presented in the Idaho National Laboratory (INL) report, “Process for Significant Nuclear Work Function Innovation Based on Integrated Operations Concepts” (INL/EXT-21-64134) [1], with a nuclear power plant (NPP) research partner. Researchers modernized two trainings: (1) an accredited instructor-led training (ILT) overview course on Westinghouse DS 480-volt (V) circuit breakers to a multimedia-focused computer-based-training (CBT) learning module, and (2) an on-demand chaptered video on how to properly rack and un-rack a Westinghouse DS 480-V circuit breaker. These modernized work products were developed and implemented in a manner consistent with the industry guidelines found in Institution of Nuclear Power Operations (INPO) Teaching and Learning 23-001 [2]. Researchers calculated that the modernized accredited training course reduced the time necessary to prepare and deliver the training material by a factor of 8:1. The amount of time learners spend in class could be reduced by this same factor. In other words, if a course took 8 hours to deliver a class, the new CBT instruction would take just over 1 hour. The researchers noted that the requirement for any practicum training by the learners with the instructor(s) would remain in place. But through interviews with new and experienced learners, the researchers discovered that the confidence of these learners in performing the racking and un-racking of the circuit breaker improved as a result of using the new modernized CBT process. Additionally, the learners who tested the modernized work products enjoyed the modernized CBT and the learning video significantly more than current in-class learning methods. These are encouraging results for the nuclear industry, as this modernization of training can be applied to other classes and is scalable across the industry. In line with the Integrated Operations for Nuclear (ION) model, positive workload analysis supports the investment of resources in modernizing NPP training processes and infrastructure. Implementation of the advanced training technologies in this report is likely to result in substantive long-term workload benefits to instructors and learners and result in hard-dollar savings on contractor spends. Additionally, investment in these modernized training processes will result in improved learner proficiency. The results of this research can be applied to additional operator, technical, and general training topics to provide additional workload and learning benefits in addition to what was explored.

42 ENGINEERING↗

A 3-Year Sample of Almost 1,600 Elves Recorded Above South America by the Pierre Auger Cosmic-Ray Observatory

Elves are a class of transient luminous events, with a radial extent typically greater than 250 km, that occur in the lower ionosphere above strong electrical storms. We report the observation of 1,598 elves, from 2014 to 2016, recorded with unprecedented time resolution (100 ns) using the fluorescence detector (FD) of the Pierre Auger Cosmic-Ray Observatory. The Auger Observatory is located in the Mendoza province of Argentina with a viewing footprint for elve observations of 3∙10sup>6 km ₂, reaching areas above the Pacific and Atlantic Oceans, as well as the Córdoba region, which is known for severe convective thunderstorms. Primarily designed for ultrahigh energy cosmic-ray observations, the Auger FD turns out to be very sensitive to the ultraviolet emission in elves. The detector features modified Schmidt optics with large apertures resulting in a field of view that spans the horizon, and year-round operation on dark nights with low moonlight background, when the local weather is favorable. The measured light profiles of 18% of the elve events have more than one peak, compatible with intracloud activity. Within the 3-year sample, 72% of the elves correlate with the far-field radiation measurements of the World Wide Lightning Location Network. The Auger Observatory plans to continue operations until at least 2025, including elve observations and analysis. To the best of our knowledge, this observatory is the only facility on Earth that measures elves with year-round operation and full horizon coverage.

79 ASTRONOMY AND ASTROPHYSICS↗

Empirically-calibrated H100 node power models for accurate AI training energy estimation

Accurately quantifying the energy use of artificial intelligence (AI) training is critical for infrastructure planning, carbon accounting, and sustainable data center operation, but few studies have directly measured the power consumption of production workloads on contemporary hardware. By combining empirical measurements from Brookhaven National Laboratory during AI training on 8-graphics-processing-unit H100 systems with open-source benchmarking data, we develop statistical models relating computational intensity to node-level power consumption. We measure the gap between manufacturer-rated thermal design power (TDP) and actual power demand during AI training. Our analysis reveals that even computationally intensive workloads operate at only 76% of the 10.2 kW TDP rating. Our architecture-specific model, calibrated to floating-point operations, predicts energy consumption with 11.4% mean absolute percentage error, significantly outperforming TDP-based approaches (27%–37% error). We identified distinct power signatures between transformer and convolutional neural network architectures, with transformers showing characteristic fluctuations that may impact grid stability. These results provide a measurement-grounded basis for improving AI training energy estimates, enabling more reliable infrastructure sizing, cost projections, and environmental impact assessments.

Newkirk, Alex C↗