Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Evaluating the Effects of Hydride Embrittlement and Pulse Width on Zircaloy Cladding Transient Performance

Pellet Cladding Mechanical Interaction is the primary failure mode for high burnup Zircaloy claddings in Light Water Reactor Reactivity Initiated Accidents. This failure mode is not seen in fresh and lower burnup fuels and is the result of environmental degradation of the cladding material and the unique loading condition on the cladding as a result of the sudden contact forces with the pellet. This paper describes work that is underway at the Idaho National Laboratory to better understand this failure mode by pre-hydriding fresh Zircaloy cladding. The pre-hydrided cladding is being mechanically characterized and will ultimately be used as part of an in-pile testing campaign at the TREAT reactor that will simulate the unique transient loading and heating conditions present in a Reactivity Initiated Accident. A description of the pre-hydriding and mechanical testing processes being followed, and initial results are presented followed by a description of the planned transient testing

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Possible origins of a time-resolved frequency shift in Raman plasma amplifiers

Raman amplification is a resonant process in which the energy of a long pump pulse is transferred to a short seed pulse by a plasma wave. There has been a significant effort to identify a window in parameter space within which the interaction is expected to be highly efficient and not degraded by competing instabilities or excessive damping. However, experimental results have thus far failed to approach the theoretical limits. Recent amplified signal spectra display a characteristic blue shift, which evolves within the seed pulse duration and suggests that the mechanism responsible for this shift is also limiting amplification in these experiments. We present the evidence and explore different hypotheses for the origins of the shift-namely localization in density minima along the axis of laser propagation induced by an ion acoustic wave that could arise from the Langmuir decay instability, filamentation which could also modulate the plasma density but in the plane transverse to laser propagation, particle trapping, and additional ionization induced by the amplified seed field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robotically Assisted Sonic Therapy (RAST) for Noninvasive Hepatic Ablation in a Porcine Model: Mitigation of Body Wall Damage with a Modified Pulse Sequence

Purpose: Robotically assisted sonic therapy (RAST) is a nonthermal, noninvasive ablation method based on histotripsy. Prior animal studies have demonstrated the ability to create hepatic ablation zones at the focal point of an ultrasound therapy transducer; however, these treatments resulted in thermal damage to the body wall within the path of ultrasound energy delivery. The purpose of this study was to evaluate the efficacy and safety of a pulse sequence intended to mitigate prefocal body wall injury. Materials and Methods: Healthy swine (n = 6) underwent hepatic RAST (VortxRx software version 1.0.1.3, HistoSonics, Ann Arbor MI) in the right hepatic lobe. A 3.0 cm spherical ablation zone was prescribed for each. Following treatment, animals underwent MRI which was utilized for ablation zone measurement, evaluation of prefocal injury, and assessment of complications. Each animal was euthanized, underwent necropsy, and the tissue was processed for histopathologic analysis of the ablation zone and any other sites concerning for injury. Results: No prefocal injury was identified by MRI or necropsy in the body wall or tissues overlying the liver. Ablation zones demonstrated uniform cell destruction, were nearly spherical (sphericity index = 0.988), and corresponded closely to the prescribed size (3.0 × 3.1 × 3.4 cm, p = 0.70, 0.36, and 0.01, respectively). Ablation zones were associated with portal vein (n = 3, one occlusive) and hepatic vein thrombosis (n = 4, one occlusive); however, bile ducts remained patent within ablation zones (n = 2). Conclusions: Hepatic RAST performed with a modified ultrasound pulse sequence in a porcine model can mitigate prefocal body wall injuries while maintaining treatment efficacy. Further study of hepatic RAST appears warranted, particularly in tumor models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electrochemistry of PUREX: R is for Reduction and Ion Transfer

The PUREX (Plutonium, Uranium, Reduction, EXtraction) process is the foundation of all industrial activities that involve the recycling of plutonium and uranium from used nuclear fuel. With over 70 years of research, engineering, and operations, it can be argued that little opportunity is left for further discovery and new fundamental understandings regarding PUREX, in general, and tri-n-butyl phosphate (TBP), in particular. Through use of an advanced electroanalytical approach, molecular-level insights regarding the back-extraction of Pu(IV) by reductive separation is reported. Studies of model PUREX systems, with lanthanide ions extracted into 20 % TBP in n-dodecane, are used to demonstrate the approach. These studies reveal knowledge pertinent to mass transfer aspects of the biphasic reductive stripping reaction central to the separation of U and Pu in PUREX. Two lanthanide ions—Ce(IV) and Yb(III)—were extracted from their concentrated solutions in aqueous 3 M HNO 3 to expressly provide electrically conducting third phases to facilitate electrochemical data acquisition. To simplify the diabolically-complicated reductive separation aspects of PUREX, the controlled polarization of electrode surfaces was used to reduce Ce(IV) and Yb(III) in place of chemical reductants. Electroanalyses of the biphasic systems with Ce(IV) and Yb(III) using three-phase electrode differential pulse voltammetry demonstrate the effects of mass transfer across water-oil interfaces on the electrode potentials for the reduction to Ce(III) and Yb(II). These reductions trigger nitrate transfer out of the oil phase for Ce and proton transfer into the organic phase for Yb. This is in correlation with the transfer of the charge-neutral ion pairs Ce·3NO 3 and Yb·2NO 3 out of the oil phases. Here, the differences in ion transfer steps reflect significant variations in the equilibrium speciation of multinuclear Ce(IV) and mononuclear Yb(III) solvates of TBP in the oil phases and the loading of the organic phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stand-Alone Dynamic System Simulation of a Fissile Solution System

Dynamic system simulations (DSS) of fissile solution systems (FSS) have been performed at Los Alamos National Laboratory (LANL) for several years. DSS have been designed and executed using the DESIRE (Direct Executing Simulation in Real Time) system, a platform ideal for expert system modelers, as it allows for direct mathematical specification of a model, and facilities for performing experiments and analyses with the model. Models built in DESIRE have been compared to historical data from several historic aqueous homogeneous reactors (AHR) showing close agreement between experimental data and model estimates. Historical systems modeled include: SUPO (Super Power), an AHR that operated at Los Alamos National Laboratory from 1951 to 1974; SILENE, which was operated by CEA at Valduc, France until 2011; KEWB (Kinetics Experiment Water Boiler) A-2 and B-5 cores, operated by North American Atomics during the 1960’s and 1970’s. SUPO is considered a benchmark for steady-state operations, SILENE for pulse, and KEWB as confirmatory for both modes. However, there are some simulation tasks that are not well-suited to DESIRE model implementation. These tasks include engineering design and analysis and providing a hardware simulator backend. It has been determined that executable simulation models would better suit these purposes, hence a process for converting DESIRE simulation models to executable simulation models was designed and implemented, and several models have been converted. DESIRE simulation models are converted to C++ executable models by an automated process. The conversion process is quick, accurate and repeatable, giving confidence that converted models will perform as well as the original DESIRE models. Extensive testing on the SUPO and accelerator driven subcritical system models has shown that the executable models perform almost identically to the DESIRE models. All major trends and events are simulated with excellent agreement and the steady-state results typically agree within a small fraction of a percent (always better than 0.1% and generally better than 0.01% agreement).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Extraction of uranium: comparison of stripping with ammonia vs. strong acid

Following extraction of uranium in the first stage of solvent extraction using a tertiary amine, typically Alamine 336, the stripping of the extracted uranium is accomplished either by use of an aqueous solution of (NH{sub 4}){sub 2}SO{sub 4} /NH{sub 4}OH or by strong-acid stripping using 400-500 g/L H{sub 2}SO{sub 4}. Both processes have their merits and determine the downstream processing. The classical stripping with ammonia is followed by addition of strong base, to precipitate ammonium uranyl sulfate (NH{sub 4}){sub 2}UO{sub 2}(SO{sub 4}){sub 2}, which yields finally the yellow cake. Conversely, stripping with H{sub 2}SO{sub 4}, followed by oxidation with hydrogen peroxide yields uranyl oxide as product. At the Cameco Key Lake operation, both processes were tested on a pilot scale, using a Bateman Pulsed Column (BPC). The BPC proved to be applicable to both processes. It met the process criteria both for extraction and stripping, leaving less than 1 mg/L of U{sub 3}O{sub 8} in the raffinate, and product solution had the required concentration of U{sub 3}O{sub 8} at high flux and reasonable height of transfer unit. In the Key Lake mill, each operation can be carried out in a single column. The main advantages of the strong-acid stripping over ammonia stripping are: (1) 60% higher flux in the extraction, (2) tenfold higher concentration of the uranium in the product solution, and (3) far more robust process, with no need of pH control in the stripping and no need to add acid to the extraction in order to keep the pH above the point of precipitation of iron compounds. The advantages of the ammoniacal process are easier stripping, that is, less stages needed to reach equilibrium and lower concentration of modifier needed to prevent the creation of a third phase. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Real-Time Wavelength Discrimination for Improved Neutron Discrimination in CLYC

We investigated the effects of optical filters on the pulse shape discrimination properties of Cs 2 LiYCl 6 :Ce (CLYC) scintillator crystals. By viewing the scintillation light through various optical filters, we attempted to better distinguish between neutron and gamma ray events in the crystal. We applied commercial interference and colored glass filters in addition to fabricating quantum dot (QD) filters by suspending QDs in plastic films and glass. QD filters ultimately failed because of instability of the QDs with respect to oxidation when exposed to ambient air, and the tendency of the QDs to aggregate in the plastic. Of the commercial filters, the best results were obtained with a bandpass interference filter covering the spectral region containing core-valence luminescence (CVL) light. However, the PSD response of filtered CLYC light was always poorer than the response exhibited by unfiltered light because filters always reduced the amount of light available for signal processing.

36 MATERIALS SCIENCE↗

SENSITIVITY STUDIES OF HEATER ROD DESIGN FOR TRANSIENT CRITICAL HEAT FLUX EXPERIMENTS IN TREAT

An important area of reactor safety is the cladding-to-coolant heat transfer under fast transient conditions. These conditions can occur during events such as a reactivity-initiated accident (RIA). In this paper we present the work performed under a laboratory directed research and development (LDRD) project, headed by Idaho National Laboratory (INL). The goal was to develop a test matrix to inform on the design of a borated steel heater rod that will induce critical heat flux (CHF) within an experimental capsule filled with water, using the TREAT facility, when submitted to a power pulse. The energy deposition in the rod and occurrence of CHF were identified as the most important key Figures of Merit (FoMs) used in the design process. Energy deposition was varied by using different pulse characteristics and various boron concentrations in the rod. A power coupling factor (PCF) was determined for each boron concentration. A sensitivity study determined the lowest limiting PCF needed to induce CHF in water with different degrees of subcooling while keeping pressure constant. Boron concentrations between 0.1-1.54 wt.% were considered. Additionally, the value of CHF is also known to increase during a rapid transient. A CHF multiplier sensitivity study focused on an example case concluded that CHF is no longer exceeded when the value is between 2.6- and 2.9-times higher. Lastly, a self-shielding study was performed to determine whether a borated tube could be used in place of a solid borated rod. The study determined that the inner 1mm of the rod can essentially be excluded or instrumented without heat generation penalties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PTT System Performance Evaluation in 3-D Imaging of AM Components

Additive manufacturing (AM, or 3D printing) for commercial nuclear energy applications is an emerging method for cost-efficient manufacturing aimed at replacing aging nuclear reactor parts and reducing costs for new construction. Because of the geometry of metallic structures of interest for nuclear applications, which consist of planar primitives with no symmetry of revolution, limited options are available for non-destructive evaluation (NDE) either during or post manufacturing. Known material flaws in AM include low density regions consisting of nonsintered powder, which have to be detected to ensure the safety of long-term performance nuclear reactor components. As a solution to NDE of AM, we are developing pulsed thermal tomography (PTT) models and depth inversion algorithms for 3D imaging. PTT has many advantages because the method is non-contact and allows for in-service, NDE of AM nuclear reactor parts. By analyzing transients of surface temperature response due to internal thermal resistances, one can obtain 3D reconstructions of material effusivity using a unique inversion algorithm developed at Argonne. This study investigates the capability of PTT in imaging several AM structures fabricated from Inconel 718 (IN718) feedstock. The AM structures have complex geometry, but do not have calibrated internal defects. The objective is to determine PTT settings, such as the total integration time, for imaging of representative AM structures. A new FLIR X8500sc IR camera with higher spatial resolution (1280x1024 at 181Hz frame rate) was integrated into the PTT laboratory setup. Software tools were developed to ensure compatibility of new camera files with legacy effusivity reconstruction codes. The new camera was used to obtain 3-D reconstructions of IN718 nozzle plate and a particle filter plate. The results demonstrate the capability of PTT in 3- D imaging of complex geometry AM structures. Further, increased resolution imaging is achieved compared to prior results using older FLIR SC4000 IR camera. In addition, preliminary studies were conducted on developing image processing algorithms for automated detection of flaws. Initial demonstrations are shown for segmentation of PTT images of flat bottom hole (FBH) specimens. Imaging of FBH specimens was described in a prior report. Intermediate results demonstrated in this report will be developed further in detection of flaws in AM specimens.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Diode pumped solid state kilohertz disk laser system for time-resolved combustion diagnostics under microgravity at the drop tower Bremen

We describe a specially designed diode pumped solid state laser system based on the disk laser architecture for combustion diagnostics under microgravity (μg) conditions at the drop tower in Bremen. The two-stage oscillator-amplifier-system provides an excellent beam profile (TEM{sub 00}) at narrowband operation (Δλ < 1 pm) and is tunable from 1018 nm to 1052 nm. The laser repetition rate of up to 4 kHz at pulse durations of 10 ns enables the tracking of processes on a millisecond time scale. Depending on the specific issue it is possible to convert the output radiation up to the fourth harmonic around 257 nm. The very compact laser system is integrated in a slightly modified drop capsule and withstands decelerations of up to 50 g (>11 ms). At first the concept of the two-stage disk laser is briefly explained, followed by a detailed description of the disk laser adaption to the drop tower requirements with special focus on the intended use under μg conditions. In order to demonstrate the capabilities of the capsule laser as a tool for μg combustion diagnostics, we finally present an investigation of the precursor-reactions before the droplet ignition using 2D imaging of the Laser Induced Fluorescence of formaldehyde.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reproducible, rugged, and inexpensive photocathode x-ray diode

The photoemissive cathode type of x-ray diode (XRD) is popular for measuring time and spectrally resolved output of pulsed power experiments. Vitreous carbon XRDs currently used on the Sandia National Laboratories Z-machine were designed in the early 1980s and use materials and processes no longer available. Additionally cathodes used in the high x-ray flux and dirty vacuum environment of a machine such as Z suffer from response changes requiring recalibration. In searching for a suitable replacement cathode, we discovered very high purity vitreous-carbon planchets are commercially available for use as biological substrates in scanning electron microscope (SEM) work. After simplifying the photocathode mounting to use commercially available components, we constructed a set of 20 XRDs using SEM planchets that were then calibrated at the National Synchrotron Light Source at Brookhaven National Laboratory. We present comparisons of the reproducibility and absolute calibrations between the current vitreous-carbon XRDs and our new design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Subcriticality Measurements with HEU (93.2) Metal Annular Storage Castings

These carefully performed and documented measurements with unreflected and unmoderated highly enriched uranium (HEU) castings can be used to benchmark calculational methods for the time decay of the fission chain multiplication process as measured with small (1 x 1 x 6 in. thick plastic scintillators with 1/4-in.-thick lead on all detector surfaces) detectors adjacent to the tightly fitting stainless steel cans that contained the HEU ({approx}93 wt%) metal. Prompt time decay measurements were performed stimulating the fission chain multiplication process with a timed, tagged Cf spontaneous fission source that emitted fission-spectrum neutrons and a time and directionally tagged 14.1-MeV neutrons from the DT reaction in a steady state generator with an embedded alpha detector. Time decay measurements were performed with HEU masses varying from 18 to 90 kg for a wide variety of source-detector-casting configurations. The use of a DT generator provided no addition information about the fission chain behavior beyond that provided by a time-tagged Cf spontaneous fission source. The main quantities obtained in the measurements were (1) the time distribution of the counts in a detector after a neutron fission in the Cf source or after the alpha detection coincident with the emission of a neutron from the DT generator (the equivalent of a pulsed neutron measurement with a randomly pulsed source) and (2) the time distribution of counts in one detector after a count in another detector (the equivalent of a two-detector Rossi-alpha measurement). Monte Carlo calculations using the MCNP-PoliMi coupled gamma-neutron transport code generally agreed with the measurement results except for some differences early in the fission chain decay process. The measurements that were performed with the HEU about 1 m above the floor were considerably affected by room return neutrons at times as early as 100 ns, and at times after 300 ns, a major portion of the time response was associated with the interaction of the HEU assemblies with the floor. This room-return effect increased with the size of the assembly because the larger assemblies subtend a larger solid angle to a neutron returning from the floor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-dimensional heteronuclear single quantum coherence (HSQC) NMR spectra of lignin isolated from Populus trichocarpa residues after CELF pretreatment and CBP fermentation

Here we present a curated dataset of a series of two-dimensional heteronuclear single quantum coherence (HSQC) nuclear magnetic resonance (NMR) spectra of lignin isolated from a woody energy crop (Populus trichocarpa) residues after co-solvent enhanced lignocellulosic fractionation (CELF) pretreatment and consolidated bioprocessing (CBP) process. The natural poplar variant GW-9947 from the Center for Bioenergy Innovation (CBI) was used. The poplar was knife milled and passed through a 1 mm sieve. The CELF pretreatment was performed in a Parr autoclave reactor with 7.5 wt % solids loading, 0.5 wt% H2SO4 as catalyst at 150°C with 15, 25 and 30 minutes, respectively. Tetrahydrofuran was added in a 1:1 mass ratio with water as the pretreatment solvent. The residues from CELF pretreatment were then subjected to CBP using the bacterium C. thermocellum DSM 1313. CBP fermentations were performed at 60 °C in a shaker at 50 grams/L solids loadings. Lignin was isolated from the pretreated samples after ball-milling in a porcelain jar with ceramic balls via Retsch PM 200 at 580 rpm for 2.5 h followed by enzymatic hydrolysis in acetate buffer (pH 4.8, 50 °C) for 48 h. The lignin samples were characterized using 13C–1H HSQC experiments which were performed in a Bruker Avance III HD 500 MHz NMR spectrometer operating at a frequency of 125.12 MHz for the 13C nucleus. A standard Bruker pulse sequence was used on a Prodigy platform cryoprobe. The dry lignin samples were dissolved in deuterated dimethylsulfoxide for HSQC experiments. The spectra were acquired under the following acquisition conditions: 210 ppm spectral width in F1 (13C) dimension with 256 data points and 11 ppm spectral width in F2 (1H) dimension with 1024 data points, a 90° pulse, a one bond C–H coupling constant of 145 Hz, a 1.0 s pulse delay, and 64 scans. All the data was processed using the TopSpin 3.6 software (Bruker BioSpin). The NMR spectra provides structural characteristics information about lignin remaining in solids after CELF (150 °C with 15, 25 and 30 minutes) process and C. thermocellum CBP.

Lignin structure, HSQC, poplar, CELF, CBP, CBI↗

Atmospheric Plasma Deposition of Diamond-like Carbon Coatings

There is great demand for thin functional coatings in the semiconductor, optics, electronics, medical, automotive and aerospace industries [1-13]. As fabricated components become smaller and more complex, the properties of the materials’ surface take on greater importance. Thin coatings play a key role in tailoring surfaces to give them the desired hardness, wear resistance, chemical inertness, and electrical characteristics. Diamond-like carbon (DLC) coatings possess an array of desirable properties, including outstanding abrasion and wear resistance, chemical inertness, hardness, a low coefficient of friction and exceptionally high dielectric strength [14-22]. Diamond-like carbon is considered to be an amorphous material, containing a mixture of sp2 and sp3 bonded carbon. Based on the percentage of sp3 carbon and the hydrogen content, four different types of DLC coatings have been identified: tetrahedral carbon (ta-C), hydrogenated amorphous carbon (a-C:H) hard, a-C:H soft, and hydrogenated tetrahedral carbon (ta-C:H) [20,24,25]. Possessing the highest hardness of 80 GPa, ta-C possesses an sp3 carbon content of 80 to 88u%, and no appreciable hydrogen content whereas a-C:H soft possesses a hardness of less than 10 GPa, contains an sp3 carbon content of 60% and a hydrogen content between 30 to 50%. Methods used to deposit DLC coatings include ion beam deposition, cathodic arc spray, pulsed laser ablation, argon ion sputtering, and plasma-enhanced chemical vapor deposition [73-83]. Researchers contend that several advantages exist when depositing DLC coatings in a low-pressure environment. For example, ion beam processes are widely utilized since the ion bombardment is thought to promote denser sp3-bonded carbon networks. Other processes, such as sputtering, are better suited for coating large parts [29,30,44]. However, the deposition of DLC in a vacuum system has several disadvantages, including high equipment cost and restrictions on the size and shape of material that may be treated. The deposition of DLC at atmospheric pressure has been demonstrated by several researchers. Izake, et al [53] and Novikov and Dymont [54] have demonstrated an electrochemical process that is carried out with organic compounds such as methanol and acetylene dissolved in ammonia. This process requires that the substrates be immersed in the liquid [53-54]. The atmospheric pressure deposition of DLC was also demonstrated by Kulik, et al. utilizing a plasma torch. However, this process requires operating temperatures in excess of 800 oC [55]. In this report, we investigate the deposition of diamond-like carbon films using a low temperature, atmospheric pressure plasma-enhanced chemical vapor deposition (PECVD) process. The films were characterized by solid-state carbon-13 nuclear magnetic resonance (13C NMR) and found to have a ratio of sp2 to sp3 carbon of 43 to 57%. The films were also tested for adhesion, coefficient of friction, and dielectric strength.

08 HYDROGEN↗

Lasers for the observation of multiple order nuclear reactions

Nuclear reaction rates become nonlinear with respect to flux (cm −2 s −1 ) in extreme environments such as those found during stellar nucleosynthesis and terrestrial nuclear detonations. To observe these effects directly in the laboratory, extremely high particle fluences (cm −2 ) are necessary but not sufficient. Reactor-based neutron sources, such as the Institut Laue-Langevin’s high-flux neutron reactor, were previously the closest to meeting this challenge, albeit over ∼hour time scales. In ultra-high flux environments, where multiple reactions occur on picosecond time scales, nuclei are unable to return to their ground states between reactions; consequently, reactions take place on excited nuclei. To accurately model high-flux environments, data on the cross-sections of excited nuclear states are required, which differ significantly from those of ground states due to spin/parity effects. In order to replicate these effects in the laboratory, short high-fluence pulses on the order of the lifetime of a typical nuclear excited state (generally ≲1 ns) are required. Particle beams generated by high-intensity lasers are uniquely positioned to meet this need with the potential to produce fluences of 10 17 protons/cm 2 and 10 22 neutrons/cm 2 over a few pico-seconds or less. In addition to providing a quantitative analysis of the rates of multiple rapid reactions in general, the present work examines a number of laser-based experiments that could be conducted in the near future to observe multiple rapid reactions for laboratory-based astrophysics and the measurement of exotic cross-sections.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fourth-generation plasma immersion ion implantation and deposition facility for hybrid surface modification layer fabrication

The fourth-generation plasma immersion ion implantation and deposition (PIIID) facility for hybrid and batch treatment was built in our laboratory recently. Comparing with our previous PIIID facilities, several novel designs are utilized. Two multicathode pulsed cathodic arc plasma sources are fixed on the chamber wall symmetrically, which can increase the steady working time from 6 h (the single cathode source in our previous facilities) to about 18 h. Meanwhile, the inner diameter of the pulsed cathodic arc plasma source is increased from the previous 80 to 209 mm, thus, large area metal plasma can be obtained by the source. Instead of the simple sample holder in our previous facility, a complex revolution-rotation sample holder composed of 24 shafts, which can rotate around its axis and adjust its position through revolving around the center axis of the vacuum chamber, is fixed in the center of the vacuum chamber. In addition, one magnetron sputtering source is set on the chamber wall instead of the top cover in the previous facility. Because of the above characteristic, the PIIID hybrid process involving ion implantation, vacuum arc, and magnetron sputtering deposition can be acquired without breaking vacuum. In addition, the PIIID batch treatment of cylinderlike components can be finished by installing these components on the rotating shafts on the sample holder.

36 MATERIALS SCIENCE↗

Admissible Crosstalk Limits in a Two Colour Interferometers for Plasma Density Diagnostics. A Reduction Algorithm

Mid Infrared (10,6 {mu}m CO{sub 2} laser lines) interferometers as a plasma density diagnostic must use two-colour systems with superposed interferometers beams at different wavelengths in order to cope with mechanical vibrations and drifts. They require a highly precise phase difference measurement where all sources of error must be reduced. One of these is the cross-talk between the signals which creates nonlinear spurious periodic mixing products. The reason may be either optical or electrical crosstalk both resulting in similar perturbations of the measurement. In the TJII interferometer a post-processing algorithm is used to reduce the crosstalk in the data. This post-processing procedure is not appropriate for very long pulses, as it is the case for in new tokamak (ITER) or stellarator (W7-X) projects. In both cases an on-line reduction process is required or--even better--the unwanted signal components must be reduced in the system itself CO{sub 2} laser interferometers which as the second wavelength use the CO laser line (5,3 {mu}m), may apply a single common detector sensitive to both wavelengths and separate the corresponding IF signals by appropriate bandpass filters. This reduces complexity of the optical arrangement and avoids a possible source of vibration induced phase noise as both signals share the same beam path. To avoid cross talk in this arrangement filtering must be appropriate. In this paper we present calculations to define the limits of crosstalk for a desired plasma density precision. A crosstalk reduction algorithm has been developed and is applied to experimental results from TJ-II pulses. Results from a single detector arrangement as under investigation for the CO{sub 2}/CO laser interferometer developed for W7-X are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation on laser absorption and x-ray radiation in microstructured titanium targets heated by short-pulse relativistic laser pulses

The enhancement effect of a microstructured surface on laser absorption and characteristic K α emission has been investigated by measuring K-shell emission from titanium (Ti) targets irradiated with high-intensity ( ∼ 10 20 W cm − 2 ), subpicosecond (500 fs) laser pulses. The experimental results indicate a modest enhancement ( 1.6 × ) of K α emission from microstructured targets compared to flat foils, but with a similar intensity and profile of He α and Li-like satellites. Particle-in-cell (PIC) simulations are implemented to further understand the underlying physical processes in the laser interaction with both targets, interpreting the mechanisms responsible for the K α enhancement. The reasons for the lower-than-expected enhancement of K α emission are discussed. The rapid heating of the bulk plasma might result in the premature shutdown of K α emission before the thermalization of hot electrons or even the end of laser pulses, suggesting that the use of K α emission as a diagnostic of the hot-electron yield or relaxation could lead to a misinterpretation. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗