Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Resonance-Enhanced Multiphoton Ionization in the X-Ray Regime

In this work, we report on the nonlinear ionization of argon atoms in the short wavelength regime using ultraintense x rays from the European XFEL. After sequential multiphoton ionization, high charge states are obtained. For photon energies that are insufficient to directly ionize a 1s electron, a different mechanism is required to obtain ionization to Ar 17+ . We propose this occurs through a two-color process where the second harmonic of the FEL pulse resonantly excites the system via a 1s→2p transition followed by ionization by the fundamental FEL pulse, which is a type of x-ray resonance-enhanced multiphoton ionization (REMPI). This resonant phenomenon occurs not only for Ar 16+ , but also through lower charge states, where multiple ionization competes with decay lifetimes, making x-ray REMPI distinctive from conventional REMPI. With the aid of state-of-the-art theoretical calculations, we explain the effects of x-ray REMPI on the relevant ion yields and spectral profile.

74 ATOMIC AND MOLECULAR PHYSICS↗

Extracting Short Rise-Time Velocity Profiles with Digital Down-Shift Analysis of Optically Up-Converted PDV Data

This work describes the digital down-shift (DDS) technique, a new method of extracting short rise-time velocity profiles in the analysis of optically up-converted PDV data. The DDS technique manipulates the PDV data by subtracting a constant velocity (i.e., the DDS velocity νDDS) from the velocity profile. DDS exploits the simple fact that the optically up-converted data ride on top of a base velocity (ν0, the apparent velocity at no motion) with a rapid rise to a high velocity (νf) of a few km/s or more. Consequently, the frequency content of the signal must describe a velocity profile that increases from ν0 to ν0 + νf. The DDS technique produces velocity reversals in the processed data before shock breakout when ν0 < νDDS < ν0 + νf. The DDS analysis process strategically selects specific DDS velocities (velocity at which the user down shifts the data) that produce anomalous reversals (maxima and/or minima), which are predictable and easy to identify in the mid-range of the data. Additional analysis determines when these maxima and minima occur. By successive application of the DDS technique and iterative analysis, velocity profiles are extracted as time as a function of velocity rather than as a function of time as it would be in a conventional velocity profile. Presented results include a description of DDS, velocity profiles extracted from laser-driven shock data with rise times of 200 ps or less, and a comparison with other techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanical Property Evaluation of CuNb Composites Manufactured with High-Pressure Torsion

Copper is under consideration as the optimum material for both high heat flux applications and high pulsed magnets. One challenge is that copper has low strength which is problematic to deployment in these applications. One solution is to alloy copper with BCC elements to improve its mechanical properties. However, the limited solubility of the BCC elements in copper requires high deformation processes to be used in order to manufacture these 3D composites. Here, high energy ball milling combined with high pressure torsion was used to manufacture 3D Cu-Nb composites. After the consolidation the mechanical properties of the composites were measured using micro- and nanohardness testing at room and elevated temperature. The results indicated that after 10 turns during the high-pressure torsion consolidation, the mechanical properties of the composites were completely saturated displaying uniform properties across the manufactured disk. Performing the high pressure torsion at temperature further improved consolidation of the disk. The high temperature nanoindentation also indicated a change in the deformation mechanism between 200 and 500 ºC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Effective Purification Process for the Nuclear Radiation Detector Tl 6 SeI 4

The semiconductor Tl6SeI4 was previously identified as a promising semiconductor for room temperature nuclear radiation detection. As the detection performance and carrier transport strongly depend on the concentration of impurity energy levels acting as scattering centers and carrier trapping, material purification is a crucial prerequisite step to obtain spectroscopic-grade detector performance. In this contribution, we present a highly efficient purification method using a bent ampule for evaporating Se, Tl2Se, and TlI precursors for Tl6Se4. On the basis of impurity analysis performed by glow discharge mass spectroscopy, the main impurities in Tl2Se were identified to be Pb, Bi, and Al, while in TlI the main impurities are Al and Sn. The bent-ampule method successfully reduces or removes the Cl, Pb, and Te impurities from the Se precursor, the Pb, Bi, and Al impurities from the Tl2Se precursor, and removes Sn from TU. Informed by the analysis results, density functional theory calculations were performed to study the identified impurities and related defects. The calculation results show that Bi and Al act as deep defect levels, which can be detrimental to the detector performance of Tl6SeI4. If the growth condition of Tl6SeI4 is Tl-rich/Se-poor, impurity of Si can introduce deep donors. However, it becomes electrically benign if growth conditions are Tl-poor/Se-rich, while Sn and Pb impurities are shallow donors. Centimeter-size Tl6SeI4 crystals were grown by the two-zone vertical Bridgman method using the purified precursors. The detector made of Tl6SeI4 crystal maintains the high resistivity on the order of 10(11) Omega.cm after purification, ideal for suppressing leakage current. The detector exhibits both full-energy and Tl escape photopeaks upon 122 keV gamma-ray from Co-57 radiation source. The electron mobility-lifetime product mu(e)tau(e) for TI6SeI4 detector is 8.1 X 10(-5) cm(2).V-1. On the basis of the carrier rise time measured from output pulses induced by 5.5 MeV alpha-particles from Am-241, the electron and hole mobilities were estimated to be 112 +/- 22 and 81 +/- 16 cm(2).V-1.s(-1), respectively, comparable to those of the leading detector materials HgI2 and TlBr. These results validate the potential of this compound for hard radiation detection, and the impurity analysis presented here allows future efforts to focus on reducing the concentration of the identified impurities.

Lin, Wenwen (ORCID:0000000216279558)↗

Spatiotemporal Monte Carlo transport methods in x-ray semiconductor detectors: Application to pulse-height spectroscopy in a-Se

Purpose: The authors describe a detailed Monte Carlo (MC) method for the coupled transport of ionizing particles and charge carriers in amorphous selenium (a-Se) semiconductor x-ray detectors, and model the effect of statistical variations on the detected signal. Methods: A detailed transport code was developed for modeling the signal formation process in semiconductor x-ray detectors. The charge transport routines include three-dimensional spatial and temporal models of electron-hole pair transport taking into account recombination and trapping. Many electron-hole pairs are created simultaneously in bursts from energy deposition events. Carrier transport processes include drift due to external field and Coulombic interactions, and diffusion due to Brownian motion. Results: Pulse-height spectra (PHS) have been simulated with different transport conditions for a range of monoenergetic incident x-ray energies and mammography radiation beam qualities. Two methods for calculating Swank factors from simulated PHS are shown, one using the entire PHS distribution, and the other using the photopeak. The latter ignores contributions from Compton scattering and K-fluorescence. Comparisons differ by approximately 2% between experimental measurements and simulations. Conclusions: The a-Se x-ray detector PHS responses simulated in this work include three-dimensional spatial and temporal transport of electron-hole pairs. These PHS were used to calculate the Swank factor and compare it with experimental measurements. The Swank factor was shown to be a function of x-ray energy and applied electric field. Trapping and recombination models are all shown to affect the Swank factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Architecture and Implementation of OpenPET Firmware and Embedded Software

OpenPET is an open source, modular, extendible, and high-performance platform suitable for multi-channel data acquisition and analysis. Due to the versatility of the hardware, firmware, and software architectures, the platform is capable of interfacing with a wide variety of detector modules not only in medical imaging but also in homeland security applications. Analog signals from radiation detectors share similar characteristics-a pulse whose area is proportional to the deposited energy and whose leading edge is used to extract a timing signal. As a result, a generic design method of the platform is adopted for the hardware, firmware, and software architectures and implementations. The analog front-end is hosted on a module called a Detector Board, where each board can filter, combine, timestamp, and process multiple channels independently. The processed data is formatted and sent through a backplane bus to a module called Support Board, where 1 Support Board can host up to eight Detector Board modules. The data in the Support Board, coming from 8 Detector Board modules, can be aggregated or correlated (if needed) depending on the algorithm implemented or runtime mode selected. It is then sent out to a computer workstation for further processing. The number of channels (detector modules), to be processed, mandates the overall OpenPET System Configuration, which is designed to handle up to 1,024 channels using 16-channel Detector Boards in the Standard System Configuration and 16,384 channels using 32-channel Detector Boards in the Large System Configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Pulse Width Dependence and Ionization Mechanism of Matrix-Assisted Laser Desorption/Ionization

Ultraviolet laser pulses at 355 nm with variable pulse widths in the region from 170 ps to 1.5 ns were used to investigate the ionization mechanism of matrix-assisted laser desorption/ionization (MALDI) for matrices 2,5-dihydroxybenzoic acid (DHB), α-cyano-4-hydroxycinnamic acid (CHCA), and sinapinic acid (SA). The mass spectra of desorbed ions and the intensity and velocity distribution of desorbed neutrals were measured simultaneously for each laser shot. These quantities were found to be independent of the laser pulse width. A comparison of the experimental measurements and numerical simulations according to the multiphoton ionization, coupled photophysical and chemical dynamics (CPCD), and thermally induced proton transfer models showed that the predictions of thermally induced proton transfer model were in agreement with the experimental data, but those of the multiphoton ionization model were not. Moreover, the predictions of the CPCD model based on singlet–singlet energy pooling were inconsistent with the experimental data of CHCA and SA, but were consistent with the experimental data of DHB only when some parameters used in the model were adjusted to extreme values. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon counting imaging with an electron-bombarded CCD: Towards a parallel-processing photoelectronic time-to-amplitude converter

We have used an electron-bombarded CCD for optical photon counting imaging. The photon event pulse height distribution was found to be linearly dependent on the gain voltage. We propose on this basis that a gain voltage sweep during exposure in an electron-bombarded sensor would allow photon arrival time determination with sub-frame exposure time resolution. This effectively uses an electron-bombarded sensor as a parallel-processing photoelectronic time-to-amplitude converter, or a two-dimensional photon counting streak camera. Several applications that require timing of photon arrival, including Fluorescence Lifetime Imaging Microscopy, may benefit from such an approach. A simulation of a voltage sweep performed with experimental data collected with different acceleration voltages validates the principle of this approach. Moreover, photon event centroiding was performed and a hybrid 50% Gaussian/Centre of Gravity + 50% Hyperbolic cosine centroiding algorithm was found to yield the lowest fixed pattern noise. Finally, the camera was mounted on a fluorescence microscope to image F-actin filaments stained with the fluorescent dye Alexa 488 in fixed cells.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study on the dynamic holdup distribution of the pulsed extraction column

In the study, a CSTR cascade dynamic hydraulic model was developed to investigate the dynamic holdup distribution of the pulsed extraction column. It is assumed that the dynamic process of the dispersed phase holdup of pulsed extraction column has equal effects with the operational process of multiple cascade CSTRs. The process is consistent with the following assumptions: the holdups vary on different stages but maintain uniform on each stage; the changes of the hydraulic parameters have impact initially on the inlet of dispersed phase, and stability will be reached gradually through stage-by-stage blending. The model was tested and verified utilizing time domain response curves of the average holdup. Nearly 150 experiments were carried out with different capillary columns, various feed liquids, and diverse continuous phases and under different operation conditions. The regression curves developed by the model show a good consistency with the experimental results. After linking parameters of the model with operational conditions, the study further found that the parameters are only linearly correlated with pulse conditions and have nothing to do with flow rate for a specific pulsed extraction column. The accuracy of the model is measured by the average holdup, and the absolute error is ±0.01. The model can provide supports for the boundary studies on hydraulics and mass transfer by making simple and reliable prediction of the dynamic holdup distribution, with relatively less accessible hydraulic experimental data. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of a digitizer for the plastic scintillation detectors of time-of-flight mass measurements

A CAEN DT5742 digitizer has been investigated to process the fast signals from the photomultiplier tubes of the time-of-flight detectors for fast ion beams. A test setup consisting of two plastic scintillation detectors and a pulsed laser source provided signals which were recorded by the digitizer and systematically analyzed with different algorithms to derive the amplitude, rise time and arrival time of the detection signal. To obtain the best amplitude and time resolutions, various optimization techniques including peak fitting and signal smoothing, interpolation improvement, and time-walk correction by amplitude and rise time have been performed and compared in detail. Here we compared the time resolutions obtained by three digital algorithms of leading-edge, zero-crossing constant-fraction (ZC-CFD) and direct constant-fraction discriminations. Finally, we found that the best time-of-flight resolution between two PMTs can be achieved as 12 ps by the method using sample minimum for peak location and using the time-walk-resistant ZC-CFD with 4-point interpolation for timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of a co-micronized composite containing palmitoylethanolamide and polydatin in an experimental model of benign prostatic hyperplasia

Palmitoylethanolamide (PEA), a fatty acid amide-signaling molecule has well-known anti-inflammatory and neuroprotective effects. Nevertheless, PEA does not possess the ability to prevent free radicals formation. Polydatin (PLD), a biological precursor of resveratrol, has antioxidant activity. A combination of PEA and PLD could, conceivably, have beneficial effects on oxidative stress produced by inflammatory processes. In the present study we investigated the effects of a co-micronized composite containing PEA and PLD (m(PEA/PLD)) in a model of testosterone-induced benign hyperplasia (BPH). BPH was provoked in rats by daily administration of testosterone propionate (3 mg/kg) for 14 days. This protocol leads to alterations in prostate morphology and increased levels of prostaglandin E2 and dihydrotestosterone as well as of 5α-reductase 1 and 5α-reductase 2 expression. Moreover, testosterone induced marked inflammation in terms of an increase in nuclear translocation of nuclear factor-κB p65 and consequently in IκB-α degradation as well as disregulation of inducible nitric oxide synthase, cyclooxygenase-2 and manganese superoxide dismutase expression and in the apoptosis pathway. Our results show, for the first time, that m(PEA/PLD) is capable of decreasing prostate weight and dihydrotestosterone production in BPH-induced rats. These effects were most likely correlated to the anti-inflammatory and apoptotic effects of m(PEA/PLD). Accordingly, these results support the view that m(PEA/PLD) should be further studied as a potent candidate for the management of BPH. - Highlights: • Chronic inflammation has emerged as a potential factor in the pathogenesis of BPH. • We evaluate the effects of m(PEA/PLD) in terms of impact on the inflammatory process and oxidative stress in BPH. • m(PEA/PLD) should be further explored as a valid candidate for the treatment of BPH.

60 APPLIED LIFE SCIENCES↗

SHINE and Mini-SHINE Column Designs for Recovery of Mo from 140 g-U/L Uranyl Sulfate

Argonne is assisting SHINE Medical Technologies (SHINE) in their efforts to develop an accelerator-driven process that utilizes a uranyl-sulfate solution for the production of fission Mo-99. In an effort to design a Mo-recovery system for the SHINE project using low-enriched uranium (LEU), we conducted batch, breakthrough, and pulse tests to determine the Mo isotherm, mass-transfer zone (MTZ), and system parameters for a 130 g-U/L uranyl sulfate solution at pH 1 and 80°C, as described previously. The VERSE program was utilized to calculate the MTZ under various loading times and velocities. The results were then used to design Mo separation and recovery columns employing a pure titania sorbent (110-μm particles, S110, and 60 Å pore size). The plant-scale column designs assume Mo will be separated from 271 L of a 141 g-U/L uranyl sulfate solution, pH 1, containing 0.0023 mM Mo. The VERSE-designed recovery systems have been tested and verified in laboratory-scale experiments, and this approach was found to be very successful.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Nano-Engineering of Detector Surfaces to Offer Unprecedented Imager Sensitivity to Soft X-rays and Low Energy Electrons

The focus of this document is to record the learning and process development achieved by the completion of the Nano-Engineering of Detector Surfaces to Offer Unprecedented Imager Sensitivity to Soft X-rays and Low Energy Electrons LDRD. The goal of this effort was to study different silicon detector surface preparation methods such as ion implant parameters, and the addition of a quantum 2-layer superlattice. Enabling the preparation of the surface of silicon detectors (front side illuminated or bonded backside illuminated) increases the responsivity of the diode to shallowly absorbed photons. This increased sensitivity in turn allows for greater fidelity in imaging events that emit low soft X-rays or low energy electrons. Prior work has focused on passivating the surface of a silicon detectors with thin layers (tens of nm thick) of materials to reduce surface recombination sites. Measurements of visible light quantum efficiency, electron responsivity, and pulsed x-ray response indicate that detectors with a 2- layer superlattice enjoy a significant benefit over equivalent detectors using an ion implant at the illuminated surface.

42 ENGINEERING↗

Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality

Purpose: To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. Methods: With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. Results: No significant differences in quantitative measures of image quality were found between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6{<=}pitch{<=}3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch=3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving coronary artery phantom acquired with the ECG-triggered high-pitch scan mode were visually free from motion artifacts at heart rates of 60 and 70 bpm. However, image quality started to deteriorate for higher heart rates. At equivalent image quality, the ECG-triggered high-pitch scan mode demonstrated lower radiation dose than other cardiac scan techniques on the same DSCT equipment (25% and 60% dose reduction compared to ECG-triggered sequential step-and-shoot and ECG-gated spiral with x-ray pulsing). Conclusions: A high-pitch (up to pitch=3.2), high-temporal-resolution (up to 75 ms) dual-source CT scan mode produced equivalent image quality relative to single-source scans using a more typical pitch value (pitch=1.0). The resultant reduction in the overall acquisition time may offer clinical advantage for cardiovascular, trauma, and pediatric CT applications. In addition, ECG-triggered high-pitch scanning may be useful as an alternative to ECG-triggered sequential scanning for patients with low to moderate heart rates up to 70 bpm, with the potential to scan the heart within one heart beat at reduced radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New measurements of low-energy resonances in the Ne 22 ( p , γ ) Na 23 reaction

The Ne 22 ( p , γ ) Na 23 reaction is one of the most uncertain reactions in the NeNa cycle and plays a crucial role in the creation of Na 23 , the only stable Na isotope. Uncertainties in the low-energy rates of this and other reactions in the NeNa cycle lead to ambiguities in the nucleosynthesis predicted from models of thermally pulsing asymptotic giant branch (AGB) stars. This in turn complicates the interpretation of anomalous Na-O trends in globular cluster evolutionary scenarios. Prior studies of the Ne 22 ( p , γ ) Na 23 , Ne 22 ( He 3 , d ) Na 23 , and C 12 ( C 12 , p ) Na 23 reactions disagree on the strengths, spins, and parities of low-energy resonances in Na 23 and the direct-capture Ne 22 ( p , γ ) Na 23 reaction rate contains large uncertainties as well. Here, we present new measurements of resonances at E r c.m. = 417 , 178, and 151 keV and of the direct-capture process in the Ne 22 ( p , γ ) Na 23 reaction. The resulting total Ne 22 ( p , γ ) Na 23 rate is approximately a factor of 20 higher than the rate listed in a recent compilation at temperatures relevant to hot-bottom burning in AGB stars. Although our rate is close to that derived from a recent Ne 22 ( p , γ ) Na 23 measurement by Cavanna et al. in 2015, we find that this large rate increase results in only a modest 18% increase in the Na 23 abundance predicted from a 5 M ⊙ thermally pulsing AGB star model from Ventura and D'Antona (2005). The estimated astrophysical impact of this rate increase is in marked contrast to the factor of ~ 3 increase in Na 23 abundance predicted by Cavanna et al. and is attributed to the interplay between the Na 23 ( p , α ) Ne 20 and Ne 20 ( p , γ ) Na 21 reactions, both of which remain fairly uncertain at the relevant temperature range.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In situ laser processing in a scanning electron microscope

Laser delivery probes using multimode fiber optic delivery and bulk focusing optics have been constructed and used for performing materials processing experiments within scanning electron microscope/focused ion beam instruments. Controlling the current driving a 915-nm semiconductor diode laser module enables continuous or pulsed operation down to sub-microsecond durations, and with spot sizes on the order of 50 {mu}m diameter, achieving irradiances at a sample surface exceeding 1 MW/cm{sup 2}. Localized laser heating has been used to demonstrate laser chemical vapor deposition of Pt, surface melting of silicon, enhanced purity, and resistivity via laser annealing of Au deposits formed by electron beam induced deposition, and in situ secondary electron imaging of laser induced dewetting of Au metal films on SiO{sub x}.

36 MATERIALS SCIENCE↗

Thermal neutron detection using alkali halide scintillators with Li-6 and pulse shape discrimination

An ideal 3 He detector replacement for the near- to medium-term future will use materials that are easy to produce and well understood, while maintaining thermal neutron detection efficiency and gamma rejection close to the 3 He standard. Toward this end, we investigated the use of standard alkali halide scintillators interfaced with 6 Li and read out with photomultiplier tubes (PMTs). Thermal neutrons are captured on 6 Li with high efficiency, emitting high-energy and triton ( 3 H) reaction products. These particles deposit energy in the scintillator, providing a thermal neutron signal; discrimination against gamma interactions is possible via pulse shape discrimination (PSD), since heavy particles produce faster pulses in alkali halide crystals. We constructed and tested two classes of detectors based on this concept. In one case 6 Li is used as a dopant in polycrystalline NaI; in the other case a thin Li foil is used as a conversion layer. In the configurations studied here, these systems are sensitive to both gamma and neutron radiation, with discrimination between the two and good energy resolution for gamma spectroscopy. We present results from our investigations, including measurements of the neutron efficiency and gamma rejection for the two detector types. We also show a comparison with Cs 2 LiYCl 6 :Ce (CLYC), which is emerging as the standard scintillator for simultaneous gamma and thermal neutron detection, and also allows PSD. We conclude that 6 Li foil with CsI scintillating crystals has near-term promise as a thermal neutron detector in applications previously dominated by 3 He detectors. The other approach, 6 Li-doped alkali halides, has some potential, but require more work to understand material properties and improve fabrication processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pure Optical Dephasing Dynamics in Semiconducting Single-Walled Carbon Nanotubes

We report a detailed study of ultrafast exciton dephasing processes in semiconducting single-walled carbon nanotubes (SWNTs) employing a sample highly enriched in a single tube species, the (6,5) tube. Systematic measurements of femtosecond pump-probe, two-pulse photon echo and three-pulse photon echo peak shift over a broad range of excitation intensities and lattice temperature (from 4.4 to 292 K) enable us to quantify the timescales of pure optical dephasing (T &lowast; 2 ), along with exciton-exciton and exciton-phonon scattering, environmental effects as well as spectral diffusion. While the exciton dephasing time (T2 ) increases from 205 fs at room temperature to 320 fs at 70 K, we found that further decrease of the lattice temperature leads to a shortening of the T2 times. This complex temperature dependence was found to arise from an enhanced relaxation of exciton population at lattice temperatures below 80 K. By quantitatively accounting the contribution from the population relaxation, the corresponding pure optical dephasing times increase monotonically from 225 fs at room temperature to 508 fs at 4.4 K. We further found that below 180 K, the inverse of the pure dephasing time (1/T &lowast; 2 ) scales linearly with temperature with a slope of 6.7 ±0.6 μeV/K, which suggests dephasing arising from one-phonon scattering (i.e. acoustic phonons). In view ofthe large dynamic disorder of the surrounding environment, the origin of the long room temperature pure dephasing time is proposed to result from reduced strength of exciton-phonon coupling by motional narrowing over nuclear fluctuations. This consideration further suggests the occurrence of remarkable initial exciton delocalization, and makes nanotubes ideal to study many-body effects in spatially confined systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗