Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear physics detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Estimation of 240 Pu Mass in a Waste Tank Using Ultra-Sensitive Detection of Radioactive Xenon Isotopes from Spontaneous Fission

We report on a technique to detect and quantify the amount of 240 Pu in a large tank used to store nuclear waste from plutonium production at the Hanford nuclear site. While the contents of this waste tank are known from previous grab sample measurements, our technique could allow for determination of the amount of 240 Pu in the tank without costly sample retrieval and analysis of this highly radioactive material. This technique makes an assumption, which was confirmed, that 240 Pu dominates the spontaneous fissions occurring in the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-mass fission detector for the fission neutron spectrum measurement

For the fission neutron spectrum measurement, the neutron energy is determined in a time-of-flight experiment by the time difference between the fission event and detection of the neutron. Therefore, the neutron energy resolution is directly determined by the time resolution of both neutron and fission detectors. For the fission detection, the detector needs not only a good timing response but also the tolerance of radiation damage and high {alpha}-decay rate. A parallel-plate avalanche counter (PPAC) has many advantages for the detection of heavy charged particles such as fission fragments. These include fast timing, resistance to radiation damage, and tolerance of high counting rate. A PPAC also can be tuned to be insensitive to particles, which is important for experiments with - emitting actinides. Therefore, a PPAC is an ideal detector for experiments requiring a fast and clean trigger for fission. In the following sections, the description will be given for the design and performance of a new low-mass PPAC for the fission-neutron spectrum measurements at LANL.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation Detection and Dual-Energy X-Ray Imaging for Port Security

Millions of cargo containers are transported across the United States border annually and are inspected for illicit radioactive material and contraband using a combination of passive radiation portal monitors (RPM) and high energy X-ray non-intrusive inspection (NII) systems. As detection performance is expected to vary with the material composition of cargo, characterizing the types of material present in cargo is important to national security. This work analyzes the passive radiation and dual energy radiography signatures from on RPM and two NII system, respectively. First, the cargos were analyzed to determine their ability to attenuate emissions from an embedded radioactive source. Secondly, dual-energy X-ray discrimination was used to determine the material composition and density of the cargos.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavefront reversal technique for self-referencing collimation testing

We present a wavefront reversal technique to produce a dual-field fringe pattern for self-referencing collimation testing in wedge-plate lateral-shear interferometry. The method requires only a suitably placed cubic beam splitter to produce two replicas of the fringe field formed by the wedge-plate lateral-shear interferometer. One of the replicas has a fringe pattern that is the reverse of the other. With these two fringe fields, the collimation testing has a built-in reference, and the detection sensitivity is twice that of a single-wedge-plate technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive Low-Energy Nuclear-Recoil Detection with Color Centers

Crystal-damage events such as tracks and point defects have been used to record and detect radiation for a long time and recently they have been proposed as a means for dark-matter detection. Color centers can be read out optically and we propose a scheme based on selective plane illumination microscopy for micrometer-scale imaging of large volumes corresponding to kilogram mass detectors. This class of detectors would be passive and would operate at room temperature and we call this the passive low-energy optical color-center nuclear-recoil (PALEOCCENE) detection method. We apply these concepts to the detection of reactor neutrinos using coherent elastic neutrino nucleus scattering (CE ν NS). Crystal-damage formation energies are intrinsically on the order of 25 eV, resulting in similarly low nuclear-recoil thresholds. Furthermore, this would enable the observation of reactor-neutrino CE ν NS with detectors as small as 10 g. Additionally, a competitive search for spin-dependent dark-matter scattering down to a dark-matter mass of 0.3 GeV could be possible. Passive crystal detectors might also be attractive for nuclear-nonproliferation safeguards if used to monitor reactor power and to put limits on plutonium production. The passive nature and small footprint of the proposed detectors implies that these might fit well within accepted reactor-safeguards operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The COHERENT Experiment at the Spallation Neutron Source

The COHERENT collaboration's primary objective is to measure coherent elastic neutrino- nucleus scattering (CEvNS) using the unique, high-quality source of tens-of-MeV neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). In spite of its large cross section, the CEvNS process has never been observed, due to tiny energies of the resulting nuclear recoils which are out of reach for standard neutrino detectors. The measurement of CEvNS has now become feasible, thanks to the development of ultra-sensitive technology for rare decay and weakly-interacting massive particle (dark matter) searches. The CEvNS cross section is cleanly predicted in the standard model; hence its measurement provides a standard model test. It is relevant for supernova physics and supernova-neutrino detection, and enables validation of dark-matter detector background and detector-response models. In the long term, precision measurement of CEvNS will address questions of nuclear structure. COHERENT will deploy multiple detector technologies in a phased approach: a 14-kg CsI[Na] scintillating crystal, 15 kg of p-type point-contact germanium detectors, and 100 kg of liquid xenon in a two-phase time projection chamber. Following an extensive background measurement campaign, a location in the SNS basement has proven to be neutron-quiet and suitable for deployment of the COHERENT detector suite. The simultaneous deployment of the three COHERENT detector subsystems will test the N=2 dependence of the cross section and ensure an unambiguous discovery of CEvNS. This document describes concisely the COHERENT physics motivations, sensitivity and plans for measurements at the SNS to be accomplished on a four-year timescale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Aligned interactions in cosmic rays

The first clean Centauro was found in cosmic rays years many ago at Mt Chacaltaya experiment. Since that time, many people have tried to find this type of interaction, both in cosmic rays and at accelerators. But no one has found a clean cases of this type of interaction.It happened finally in the last exposure of emulsion at Mt Chacaltaya where the second clean Centauro has been found. The experimental data for both the Centauros and STRANA will be presented and discussed in this paper. We also present our comments to the intriguing question of the existence of a type of nuclear interactions at high energy with alignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field Trial of LANL On-Line Advanced Enrichment Monitor for UF6 GCEP

The outline of this presentation is: (1) Technology basis of on-line enrichment monitoring; (2) Timescale of trial; (3) Description of installed equipment; (4) Photographs; (5) Results; (6) Possible further development; and (7) Conclusions. Summary of the good things about the Advanced Enrichment Monitor (AEM) performance is: (1) High accuracy - normally better than 1% relative, (2) Active system as accurate as passive system, (3) Fast and accurate detection of enrichment changes, (4) Physics is well understood, (5) Elegant method for capturing pressure signal, and (6) Data capture is automatic, low cost and fast. A couple of negative things are: (1) Some jumps in measured passive enrichment - of around +2% relative (due to clock errors?); and (2) Data handling and evaluation is off-line, expensive and very slow. Conclusions are: (1) LANL AEM is being tested on E23 plant at Capenhurst; (2) The trial is going very well; (3) AEM could detect production of HEU at potentially much lower cost than existing CEMO; (4) AEM can measure {sup 235}U assay accurately; (5) Active system using X-Ray source would avoid need for pressure measurement; (6) Substantial work lies ahead to go from current prototype to a production instrument.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A novel, multichannel, comb-frequency Doppler backscatter system

Doppler backscattering has emerged in recent years as a powerful diagnostic tool in high temperature fusion plasmas. The technique is sensitive to plasma turbulence flow and has been utilized to determine radial electric field and to study geodesic acoustic modes, zonal flows, and intermediate scale density turbulence. The current manuscript describes a novel technique for creating a stable, multichannel system covering the V-band frequency range (50-75 GHz) which enables simultaneous monitoring of turbulent flows and fluctuation levels at eight distinct spatial locations. The system is based on a high-frequency, low phase noise comb-frequency generator combined with a filter bank and quadrature detection system. The system is now in operation on DIII-D and has allowed monitoring of the flow and turbulence levels across the plasma radius during events such as the L-H transition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NDFOM Description for DNDO Summer Internship Program

Nuclear Detection Figure of Merit (NDFOM) is a DNDO-funded project at LANL to develop a software framework that allows a user to evaluate a radiation detection scenario of interest, quickly obtaining results on detector performance. It is intended as a “first step” in detector performance assessment, and meant to be easily employed by subject matter experts (SMEs) and non-SMEs alike. The generic scenario consists of a potential source moving past a detector at a relative velocity and with a distance of closest approach. Such a scenario is capable of describing, e.g., vehicles driving through portal monitors, border patrol scanning suspected illicit materials with a handheld instrument, and first responders with backpackor pager-based detectors (see Fig. 1). The backend library is prepopulated by the NDFOM developers to include sources and detectors of interest to DNDO and its community.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Detection of questionable occlusal carious lesions using an electrical bioimpedance method with fractional electrical model

This in vitro study evaluated the diagnostic performance of an alternative electric bioimpedance spectroscopy technique (BIS-STEP) detect questionable occlusal carious lesions. Six specialists carried out the visual (V), radiography (R), and combined (VR) exams of 57 sound or non-cavitated occlusal carious lesion teeth classifying the occlusal surfaces in sound surface (H), enamel caries (EC), and dentinal caries (DC). Measurements were based on the current response to a step voltage excitation (BIS-STEP). A fractional electrical model was used to predict the current response in the time domain and to estimate the model parameters: Rs and Rp (resistive parameters), and C and α (fractional parameters). Histological analysis showed caries prevalence of 33.3% being 15.8% hidden caries. Combined examination obtained the best traditional diagnostic results with specificity = 59.0%, sensitivity = 70.9%, and accuracy = 60.8%. There were statistically significant differences in bioimpedance parameters between the H and EC groups (p = 0.016) and between the H and DC groups (Rs, p = 0.006; Rp, p = 0.022, and α, p = 0.041). Using a suitable threshold for the Rs, we obtained specificity = 60.7%, sensitivity = 77.9%, accuracy = 73.2%, and 100% of detection for deep lesions. It can be concluded that BIS-STEP method could be an important tool to improve the detection and management of occlusal non-cavitated primary caries and pigmented sites.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the Versatile Array of Neutron Detectors at Low Energy (VANDLE)

The Versatile Array of Neutron Detectors at Low Energy (VANDLE) is a new, highly efficient plastic-scintillator array constructed for decay and transfer reaction experimental setups that require neutron detection. The versatile and modular design allows for customizable experimental setups including beta-delayed neutron spectroscopy and (d,n) transfer reactions in normal and inverse kinematics. The neutron energy and prompt-photon discrimination is determined through the time of flight technique. Fully digital data acquisition electronics and integrated triggering logic enables some VANDLE modules to achieve an intrinsic efficiency over 70% for 300-keV neutrons, measured through two different methods. A custom Geant4 simulation models aspects of the detector array and the experimental setups to determine efficiency and detector response. Lastly, a low detection threshold, due to the trigger logic and digitizing data acquisition, allowed us to measure the light-yield response curve from elastically scattered carbon nuclei inside the scintillating plastic from incident neutrons with kinetic energies below 2 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Capabilities of the INL ZPPR to Support Active Interrogation Research with SNM

For over 40 years Idaho National Laboratory (INL) and its predecessor organizations have maintained and operated the Zero-Power Physics Reactor (ZPPR) as a test bed for studying reactor physics and nuclear reactor design. Although the ZPPR is no longer operated as an active research reactor, it’s infrastructure (radiation shielding, safety systems, physical safeguards) and special nuclear material (SNM) inventory (variably enriched uranium and plutonium fuels available in metallic, oxide, alloy, and other forms) still makes the facility a unique national resource for research and development activities involving the use of SNM. Recently INL has utilized this facility to serve as a test and evaluation facility for active interrogation research and development. This facility is currently hosting scoping experiments using neutron and x-ray radiation sources to characterize SNM active interrogation signatures and to develop tools and techniques to detect and identify shielded SNM. This paper presents an overview of the facility’s infrastructure and assets and describes recent active interrogation experiments that have taken place using high-energy x-ray sources and compact electronic neutron generators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2540 km: Bimagic baseline for neutrino oscillation parameters

We consider a low energy neutrino factory setup with a detector placed at a distance of 2540 km. At this baseline, for both normal and inverted hierarchical neutrino mass spectrum, the wrong-sign muon event spectrum is almost independent of CP phase {delta} and the mixing angle {theta}{sub 13} in a specific energy window. This leads to an unambiguous determination of the hierarchy. In addition, a part of the muon spectrum remain sensitive to {delta} and {theta}{sub 13}, so that the same setup can be used to probe these parameters as well using a broadband beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

India-based Neutrino Observatory(INO): A Status Report

We present a status report on the proposed India-based Neutrino Observatory (INO). Various aspects of the INO project such as its location, the present status of the detector development, physics goals and simulation studies are discussed briefly. In particular we focus on physics studies possible with an iron calorimeter detector (ICAL) and the logistics of constructing this detector at INO. Such a detector would make precision measurements of neutrino oscillation parameters with atmospheric neutrinos in the first phase with the possibility of acting as a far-end detector of a future neutrino factory or beta beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental study of the {beta}-delayed neutron decay of {sup 21}N

The first spectroscopic study for the {beta} decay of {sup 21}N is carried out based on {beta}-n, {beta}-{gamma}, and {beta}-n-{gamma} coincidence measurements. The neutron-rich {sup 21}N nuclei are produced by the fragmentation of the E/A=68.8 MeV {sup 26}Mg primary beam on a thick {sup 9}Be target and are implanted into a thin plastic scintillator that also plays the role of {beta} detector. The time of flight of the emitted neutrons following the {beta} decay are measured by the surrounding neutron sphere and neutron wall arrays. In addition, four clover germanium detectors are used to detect the {beta}-delayed {gamma} rays. Thirteen new {beta}-delayed neutron groups are observed with a total branching ratio of 90.5{+-}4.2%. The half-life for the {beta} decay of {sup 21}N is determined to be 82.9{+-}7.5 ms. The level scheme of {sup 21}O is deduced up to about 9 MeV excitation energy. The experimental results for the {beta} decay of {sup 21}N are compared to the shell-model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photofission of {sup 238}U in the giant-resonance region

Data on cross sections for the reaction {sup 238}U(γ,F) in the giant-resonance region were analyzed in connection with the preparation of new experiments aimed at studying {sup 238}U photofission—in particular, in beams of photons from in-flight positron annihilation on internal targets of positron storage rings. These data were taken from measurements also performed with annihilation photons but from positron beams external to the accelerators used. The procedures applied in such measurements and based both on processing the multiplicity of detected neutrons and on detecting fission fragments were also analyzed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗