Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nu”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

691 records · Page 39

Application of High-Spatial Resolution LA-MC-ICP-MS in Planetary Materials

High-precision stable and radiogenic isotopic measurements of planetary materials can help elucidate processes taking place during early Solar System formation, as well as during subsequent planetary differentiation. Laser Ablation Multi Collector Inductively Coupled Plasma Mass Spectrometry (LA-MC-ICP-MS) adds the valuable ability of preserving the spatial context of these isotopic measurements, by sampling small sample volumes (~10 – 60 um diameter) using a pulsed laser system. In the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center, these in-situ isotopic measurements are primarily made using the Applied SpectraTM iX-fs-Tandem LA-LIBS Instrument coupled to the Nu InstrumentsTM SP1700 MC-ICP-MS. The instrumental set-up also provides simultaneous Laser Induced Breakdown Spectroscopy (LIBS) measurements and the potential use of a low energy path with a collision/reaction cell for additional interference removal, though we focus here on the typical high-energy LA-MC-ICP-MS operation. We will provide examples of stable (e.g., Mg) and radiogenic (e.g., Lu-Hf) isotopic systems measured in planetary materials and their terrestrial analogs. The measurement of mass dependent Mg isotopic variations is an important tool for reconstructing processes such as evaporation and condensation of solids in the solar nebula. For early Solar System samples, Mg isotope measurements are also important for the short-lived (t1/2 = 0.7 Ma) Al-Mg chronometer. During laser ablation analyses, the measurement of the Al-Mg isotopic system is made in medium mass resolution (RP ~9500 at ~20% transmission) to limit interferences from 48Ti2+ and 48Ca2+ on 24Mg+, in addition to 52Cr2+ and 12C14N+ on 26Mg+. Measured in the mineral zircon, the 176Lu-176Hf decay system is often used for understanding the growth of continents on Earth, and is also a vital aid in deciphering early large-scale planetary differentiation processes, such as the crystallization of the lunar magma ocean, which is thought to be responsible for much of the Moon’s crust. Lu-Hf measurements are made in low resolution mode (RP <2000), with 10 ion masses (from 171Yb to 180Hf) measured simultaneously to facilitate corrections for isobaric interferences from 176Yb and 176Lu on 176Hf.

Jacob B Setera↗

Characterization of NUW-LHT-5m, A Lunar Highland Simulant

A new simulant of the lunar highlands regolith, NUW-LHT-5M, was designed by NASA and manufactured by Washington Mills. The simulant was based on Apollo 16 data and is a member of the NU-LHT-series. NASA’s Marshall Space Flight Center and Johnson Space Center have already purchased 3 metric tons of the simulant for advanced engineering work. In support of engineering uses of the simulant, we provided measurements of the simulant including: mineral abundance and composition, liberation, X-ray fluorescence (XRF), ferrous iron, carbon, sulfur, 60 element inductively coupled plasma (ICP), loss on ignition, particle size, both 2D and 3D particle shape, specific surface area, shear, cohesion, internal friction, helium pycnometry, minimum index density, tap density, magnetic susceptibility, cryogenic and high temperature permittivity, visible and near-infrared (VNIR) and middle infra-red spectroscopy (MIR), differential scanning calorimetry (DSC), viscosity, thermal diffusivity, thermal conductivity, thermal gravimetric analysis (TGA), evolved gas analysis (EGA), and spark sintering. For the crystalline components the design of the simulant called for two rocks from the Stillwater Complex, Montana: 17.6 wt% norite, 37.7% anorthosite, and 4.7 wt% olivine from an unspecified commercial source. The other 40% of the simulant was a high calcium (An100), vesicular glass that Washington Mills made specifically for the simulant. Fabrication and quality control processes for both the glass and the simulant are described. Importantly, most of the graphs and tables presented herein provide values for both the new simulant and data for the older NASA mare simulant, JSC-1A. Finally, we discussed the current limitations of NUW-LT-5M and most other lunar regolith simulants to replicate the lunar material.

lunar regolith simulant↗

Spatiospectral and picosecond spatiotemporal properties of a broad area operating channeled-substrate-planar laser array

Spatiospectral and spatiotemporal properties of an eight-element channeled-substrate-planar laser array are investigated in both CW and pulsed operating conditions. The closely spaced CSP array with strong optical coupling between array elements is characterized by a broad area laserlike operation determined by its spatial mode spectra. The spatiotemporal evolution of the near and far field exhibits complex dynamic behavior in the picosecond to nanosecond domain. Operating parameters for the laser device have been experimentally determined. These results provide important information for the evaluation of the dynamic behavior of coherent semiconductor laser arrays.

Yu, NU↗

WGM Resonators for Terahertz-to-Optical Frequency Conversion

Progress has been made toward solving some practical problems in the implementation of terahertz-to-optical frequency converters utilizing whispering-gallery-mode (WGM) resonators. Such frequency converters are expected to be essential parts of non-cryogenic terahertz- radiation receivers that are, variously, under development or contemplated for a variety of applications in airborne and spaceborne instrumentation for astronomical and military uses. In most respects, the basic principles of terahertz-to-optical frequency conversion in WGM resonators are the same as those of microwave (sub-terahertz)-to-optical frequency conversion in WGM resonators, various aspects of which were discussed in the three preceeding articles. To recapitulate: In a receiver following this approach, a preamplified incoming microwave signal (in the present case, a terahertz signal) is up-converted to an optical signal by a technique that exploits the nonlinearity of the electromagnetic response of a whispering-gallery-mode (WGM) resonator made of LiNbO3 or another suitable electro-optical material. Upconversion takes place by three-wave mixing in the resonator. To ensure the required interaction among the optical and terahertz signals, the WGM resonator must be designed and fabricated to function as an electro-optical modulator while simultaneously exhibiting (1) resonance at the required microwave and optical operating frequencies and (2) phase matching among the microwave and optical signals circulating in the resonator. Downstream of the WGM resonator, the up-converted signal is processed photonically by use of a tunable optical filter or local oscillator and is then detected. The practical problems addressed in the present development effort are the following: Satisfaction of the optical and terahertz resonance-frequency requirement is a straightforward matter, inasmuch as the optical and terahertz spectra can be measured. However, satisfaction of the phase-matching requirement is more difficult. The approach followed in the present development is to perform computer simulations of the microwave and optical signals circulating in the resonator to test for phase matching. To enable excitation of the terahertz WGM resonator mode, it is also necessary to ensure phase matching between that mode and the incoming terahertz radiation. In the present development, the incoming signal is coupled into the WGM resonator via a tapered waveguide in the form of a fused silica rod. The phase-matching requirement is satisfied at one point along the taper; the rod is positioned with this point in proximity to the WGM resonator. To maximize the conversion efficiency, it is necessary to maximize the spatial overlap among the terahertz and optical modes in the WGM resonator. In the absence of a special design effort to address this issue, there would be little such overlap because, as a consequence of a large difference between wavelengths, the optical and terahertz modes would be concentrated at different depths from the rim of a WGM resonator. In the present development, overlap is ensured by constructing the WGM resonator as a ring (see figure) so thin that the optical and terahertz modes are effectively forced to overlap.

Strekalov,Dmitry↗

Review of Solar Energetic Particle Models

Solar Energetic Particle (SEP) events are interesting from a scientific perspective as they are the product of a broad set of physical processes from the corona out through the extent of the heliosphere, and provide insight into processes of particle acceleration and transport that are widely applicable in astrophysics. From the operations perspective, SEP events pose a radiation hazard for aviation, electronics in space, and human space exploration, in particular for missions outside of the Earth’s protective magnetosphere including to the Moon and Mars. Thus, it is critical to improve the scientific understanding of SEP events and use this understanding to develop and improve SEP forecasting capabilities to support operations. Many SEP models exist or are in development using a wide variety of approaches and with differing goals. These include computationally intensive physics-based models, fast and light empirical models, machine learning-based models, and mixed-model approaches. The aim of this paper is to summarize all of the SEP models currently developed in the scientific community, including a description of model approach, inputs and outputs, free parameters, and any published validations or comparisons with data.

Kathryn Whitman↗