Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light pulses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Time-resolved synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument future timing detectors at the High Luminosity Large Hadron Collider (HL-LHC) experiments. While conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low energy X-rays with good energy resolution and excellent timing (tens of picoseconds). Here, using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 35 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2.1 ns intervals, and with an energy dispersion (ΔE/E) of 1 X 10 -4 . LGADs fabricated by Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 µm to 50 µm and different gain layer designs were read out a two stage fast amplification circuit and digitized with a high bandwidth, high sampling rate oscilloscope. PIN devices from HPK were characterized as well. A systematic and detailed characterization of the devices’ energy linearity, resolution and timing resolution as a function of X-ray energy was performed for different biasing voltages at room temperature

Charge multiplication↗

Fusion and fission of particle-like chiral nematic vortex knots

Vortex knots have been seen decaying in many physical systems. Here we describe topologically protected vortex knots, which remain stable and undergo fusion and fission and conserve a topological invariant. The host medium, a chiral nematic liquid crystal, exhibits intrinsic chirality of molecular alignment, whereas cores of the vortex lines are structurally achiral regions in which a molecular twist cannot be defined. We can reversibly switch between fusion and fission of these vortex knots by applying electric pulses. This reveals the physical embodiments of concepts in knot theory, such as connected sums of knots and band surgeries. Our findings demonstrate the interplay of chirality effects at hierarchical levels from constituent molecules to the host medium and the energetically stable chiral vortex knots. This emergent physical behaviour may enable applications in electro-optics and photonics in which such fusion and fission processes of vortex knots can be used for controlling light.

Applied mathematics↗

Ultrafast renormalization of the magnetic continuum in the proximal Kitaev quantum spin liquid H 3 LiIr 2 O 6 by tr-RIXS [Invited]

We present the first circularly polarized non-resonant pump time-resolved resonant inelastic X-ray scattering (tr-RIXS) experiment in H 3 LiIr 2 O 6 , an iridium-based Kitaev system. Our calculations and experimental results are consistent with the modification of the low-energy magnetic excitations in H 3 LiIr 2 O 6 only during illumination by the laser pulse. We discuss these results in a cooperative framework between the Floquet engineering of the exchange interactions and the dynamic renormalization of electron-electron correlations. However, the penetration length mismatch between the X-ray probe and laser pump and the intrinsic complexity of Kitaev magnets prevents us from unequivocally extracting towards which ground state H 3 LiIr 2 O 6 is driven. We outline possible solutions to these challenges for light-driven stabilization and observation of the Kitaev quantum spin liquid limit by RIXS.

Kim, Jungho [Argonne National Laboratory (ANL), Ar↗

High-burnup Experiments in Reactivity Initiated Accidents (HERA)

High-burnup Experiments in Reactivity-initiated Accidents (HERA) is a joint experimental program (JEEP) operating within the United States (U.S.) Nuclear Energy Agency’s (NEA’s) framework for irradiation experiments (FIDES). HERA is dedicated to the understanding of light water reactor (LWR) fuel performance at high burnup under reactivity-initiated accidents (RIA). In-pile RIA experiments have been performed on high-burnup fuels (e.g., above 60 gigawatt days per metric ton of uranium [GWd/MTU]) in the CABRI reactor at the Cadarache site in southern France, and the Nuclear Safety Research Reactor (NSRR) in Japan. However, most of these experiments have taken place with heavily corroded Zircaloy claddings with pulse widths that are narrower (e.g., 5 ms – 30 ms full-width-half-max [FWHM]) than what would be likely in a commercial LWR (e.g., 30 ms – 80 ms FWHM). A few tests were performed in the CABRI facility with FWHM up to 76 ms, though only one “blistered” rod experienced cladding failure. Heavy waterside corrosion and narrow pulse widths are both known to increase the vulnerability of LWR fuel to pellet cladding mechanical interaction (PCMI). The HERA proposal is designed to: (1) quantify the impact of pulse width on fuel performance, offering new insight into the applicability of existing data; (2) generate new data on high burnup fuel under pulse conditions prototypic of LWRs; (3) quantify the additional margin provided by modern cladding alloys to PCMI failure limits; and (4) offer improved data for modelers using specially designed tests that eliminate key uncertainties in high-burnup fuel tests.

(HERA)↗

Temporal X-ray Reconstruction using Temporal and Spectral Measurements at LCLS

Transverse deflecting structures (TDSs) are widely used in accelerator physics to measure the longitudinal density of particle bunches. When used in combination with a dispersive section, the whole longitudinal phase space density can be imaged. At the Linac Coherent Light Source (LCLS), the installation of such a device downstream of the undulators enables the reconstruction of the X-ray temporal intensity profile by comparing longitudinal phase space distributions with lasing on and lasing off. However, the resolution of this TDS is limited to around 1 fs rms (root mean square), and therefore, it is not possible to resolve single self-amplified spontaneous emission (SASE) spikes within an X-ray photon pulse. By combining the power spectrum from a high resolution photon spectrometer and the temporal structure from the TDS, the overall resolution is enhanced, thus allowing the observation of temporal, single SASE spikes. The combined data from the spectrometer and the TDS is analysed using an iterative algorithm to obtain the actual intensity profile. In this paper, we present some improvements to the reconstruction algorithm as well as real data taken at LCLS.

47 OTHER INSTRUMENTATION↗

Multiparameter laser performance characterization of liquid crystals for polarization control devices in the nanosecond regime

Abstract Interactions of liquid crystals (LC’s) with polarized light have been studied widely and have spawned numerous device applications, including the fabrication of optical elements for high-power and large-aperture laser systems. Currently, little is known about both the effect of incident polarization state on laser-induced–damage threshold (LIDT) and laser-induced functional threshold (LIFT) behavior at sub-LIDT fluences under multipulse irradiation conditions. This work reports on the first study of the nanosecond-pulsed LIDT’s dependence on incident polarization for several optical devices employing oriented nematic and chiral-nematic LC’s oriented by surface alignment layers. Accelerated lifetime testing was also performed to characterize the ability of these devices to maintain their functional performance under multipulse irradiation as a function of the laser fluence at both 1053 nm and 351 nm. Results show that the LIDT varies as a function of input polarization by 30–80% within the same device, while the multipulse LIFT (which can differ from the nominal LIDT) depends on irradiation conditions such as laser fluence and wavelength.

47 OTHER INSTRUMENTATION↗

A graphene-based magnetoplasmonic metasurface for actively tunable transmission and polarization rotation at terahertz frequencies

The rise of terahertz (THz)-based technologies has prompted intense interest in methods for manipulating the properties of THz radiation. In this Letter, we experimentally demonstrate a graphene micro-ribbon-based metasurface that allows us to tailor and dynamically tune the transmission and polarization rotation spectra of impinging THz pulses. This is achieved by controlling the geometry of the ribbon pattern and the applied DC magnetic field, both of which strongly influence the magnetoplasmonic response of the metasurface. The properties of the metasurface can be accurately modeled using an effective medium approach that considers the capacitive interaction of the ribbons resulting from the THz electric field. Furthermore, our results highlight the promise of graphene-based THz devices that leverage the strongly enhanced light–matter interactions resulting from patterning.

36 MATERIALS SCIENCE↗

Billion-pixel x-ray camera (BiPC-X)

The continuing improvement in quantum efficiency (above 90% for single visible photons), reduction in noise (below 1 electron per pixel), and shrink in pixel pitch (less than 1 μm) enable billion-pixel x-ray cameras (BiPC-X) based on commercial complementary metal–oxide–semiconductor (CMOS) imaging sensors. We describe BiPC-X designs and prototype construction based on flexible tiling of commercial CMOS imaging sensors with millions of pixels. Device models are given for direct detection of low energy x rays (<10 keV) and indirect detection of higher energies using scintillators. Modified Birks’s law is proposed for light yield non-proportionality in scintillators as a function of x-ray energy. Single x-ray sensitivity and spatial resolution have been validated experimentally using a laboratory x-ray source and the Argonne Advanced Photon Source. Possible applications include wide field-of-view or large x-ray aperture measurements in high-temperature plasmas, the state-of-the-art synchrotron, x-ray free electron laser, and pulsed power facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single Electron Self-coherence and Its Wave/Particle Duality in the Electron Microscope

Intensities in high-resolution phase-contrast images from electron microscopes build up discretely in time by detecting single electrons. A wave description of pulse-like coherent-inelastic interaction of an electron with matter implies a time-dependent coexistence of coherent partial waves. Their superposition forms a wave package by phase decoherence of 0.5 - 1 radian with Heisenbergs energy uncertainty ΔE H = $\hbar$/2 Δt -1 matching the energy loss ΔE of a coherent-inelastic interaction and sets the interaction time Δt. In these circumstances, the product of Planck's constant and the speed of light hc is given by the product of the expression for temporal coherence λ 2 /Δλ and the energy loss ΔE. Experimentally, the self-coherence length was measured by detecting the energy-dependent localization of scattered, plane matter waves in surface proximity exploiting the Goos–Hänchen shift. Chromatic-aberration Cc-corrected electron microscopy on boron nitride (BN) proves that the coherent crystal illumination and phase contrast are lost if the self-coherence length shrinks below the size of the crystal unit cell at ΔE > 200 eV. Finally, in perspective, the interaction time of any matter wave compares with the lifetime of a virtual particle of any elemental interaction, suggesting the present concept of coherent-inelastic interactions of matter waves might be generalizable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laser, vacuum and gas reaction chamber for operando measurements at NSLS-II's 28-ID-2

We present a laser reaction chamber that we have developed for in situ/operando X-ray diffraction measurements at the NSLS-II 28-ID-2 X-ray powder diffraction beamline. This chamber allows for rapid and dynamic sample heating under specialized gas environments, spanning ambient conditions down to vacuum pressures. We demonstrate the capabilities of this setup through two applications: laser-driven heating in polycrystalline iron oxide and in single-crystal WTe 2 . Our measurements reveal the ability to resolve chemical reaction kinetics over minutes with 1 s time resolution. This setup advances opportunities for in situ/operando X-ray diffraction studies of both bulk and single-crystal materials.

36 MATERIALS SCIENCE↗

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗

Synthesis and processing of lithium-loaded plastic scintillators on the kilogram scale

Plastic scintillators that can discriminate between gamma rays, fast neutrons, and thermal neutrons were synthesized and characterized while considering the performance at the kilogram scale. The synthesis and processing of these plastic scintillators on the kilogram scale required examination of several factors. The examination of these factors was necessitated by the inclusion of 0.1 wt.% lithium-6 to enable detection of thermal neutrons. First, methacrylic acid was used as an additive to solubilize salts of lithium-6, which allow for a thermal-neutron capture reaction that produces scintillation light following energy transfer. Second, a trade-off between scintillation performance and processability was considered because the increasing content of the methacrylic acid that aided processability resulted in a sharp decrease in the light output. The use of small amounts of methacrylic acid (≤3 wt.%) resulted in better performance but required high processing temperatures. At large scales, these high temperatures could initiate exothermic polymerization that results in premature curing and/or defects. Additionally, the deleterious effects of the methacrylic acid may be mitigated by using m-terphenyl as a primary dye rather than 2,5-diphenyloxazole (PPO), which has been traditionally used in organic scintillators. Finally, the curing environment was controlled to avoid defects like cracking and discolouration​ while maintaining solubility of dopants during curing. For scintillators that were produced from kilogram-scale batches of precursors, the effective attenuation of scintillation light was characterized.

36 MATERIALS SCIENCE↗

The SuperCam Instrument Suite on the NASA Mars 2020 Rover: Body Unit and Combined System Tests

The SuperCam instrument suite provides the Mars 2020 rover, Perseverance, with a number of versatile remote-sensing techniques that can be used at long distance as well as within the robotic-arm workspace. These include laser-induced breakdown spectroscopy (LIBS), remote time-resolved Raman and luminescence spectroscopies, and visible and infrared (VISIR; separately referred to as VIS and IR) reflectance spectroscopy. A remote micro-imager (RMI) provides high-resolution color context imaging, and a microphone can be used as a stand-alone tool for environmental studies or to determine physical properties of rocks and soils from shock waves of laser-produced plasmas. SuperCam is built in three parts: The mast unit (MU), consisting of the laser, telescope, RMI, IR spectrometer, and associated electronics, is described in a companion paper. The on-board calibration targets are described in another companion paper. Here we describe SuperCam’s body unit (BU) and testing of the integrated instrument. The BU, mounted inside the rover body, receives light from the MU via a 5.8 m optical fiber. The light is split into three wavelength bands by a demultiplexer, and is routed via fiber bundles to three optical spectrometers, two of which (UV and violet; 245–340 and 385–465 nm) are crossed Czerny-Turner reflection spectrometers, nearly identical to their counterparts on ChemCam. The third is a high-efficiency transmission spectrometer containing an optical intensifier capable of gating exposures to 100 ns or longer, with variable delay times relative to the laser pulse. This spectrometer covers 535–853 nm ( $105\text{--}7070~\text{cm}^{-1}$ Raman shift relative to the 532 nm green laser beam) with $12~\text{cm}^{-1}$ full-width at half-maximum peak resolution in the Raman fingerprint region. The BU electronics boards interface with the rover and control the instrument, returning data to the rover. Thermal systems maintain a warm temperature during cruise to Mars to avoid contamination on the optics, and cool the detectors during operations on Mars.Results obtained with the integrated instrument demonstrate its capabilities for LIBS, for which a library of 332 standards was developed. Examples of Raman and VISIR spectroscopy are shown, demonstrating clear mineral identification with both techniques. Luminescence spectra demonstrate the utility of having both spectral and temporal dimensions. Finally, RMI and microphone tests on the rover demonstrate the capabilities of these subsystems as well.

47 OTHER INSTRUMENTATION↗

Evaluation of a fiber-coupled x-ray diffraction detector for dynamic compression experiments

The long-term x-ray diffraction (XRD) detector scheme compatible with Z-containment experiments will involve conversion of the diffracted x-rays to optical light, which will be transported away from the Z-Dynamic Materials Properties (DMP) load and detected on a fast-gated camera. In this so-called DIffraction SCintillator Optic (DISCO) scheme , the scintillator is coupled to a long, coherent imaging fiber bundle using a custom lens system with high numerical aperture. In addition, the DISCO diagnostic incorporates time-gating to allow measurement only during the short time window of the x-ray pulse in which XRD occurs, thereby significantly reducing unwanted background generated by the Z-DMP load. Dynamic compression experiments were performed at the Chama target chamber to evaluate the DISCO diagnostic . Specifically, a Zr sample was laser-shocked with the Chaco laser while the Z-Beamlet (ZBL) laser was used to generate x-rays, which enabled time-gated 6.7-keV XRD patterns from the compressed Zr sample to be obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SCALE 6.2.4 Validation: Reactor Physics

This report is the third volume in a report series documenting the validation of SCALE 6.2.4, which is used herein with ENDF/B-VII.1 libraries, for nuclear criticality safety, reactor physics, and radiation shielding applications. This report focuses on validating SCALE capabilities that affect reactor physics applications. The experimental data used as basis for validation consists of measurement data for nuclide inventory, decay heat, and full-core experiments and include the following: 1. radiochemical assay measurements of 40 nuclides of importance to burnup credit, decay heat, and radiation shielding in 169 light-water reactor (LWR) spent nuclear fuel samples that cover burnups up to 70 GWd/MTU and initial enrichments up to 4.9% 235 U; 2. full-assembly decay heat measurements for 236 LWR assemblies with: a. initial fuel enrichments up to 4% 235 U, b. assembly burnups of 5–51 GWd/MTU, and c. cooling times after discharge in the 2- to 27-year range (of importance to spent nuclear fuel storage, transportation, and disposal); and 3. pulse fission irradiations for fissionable materials at cooling times of interest to severe accident analyses (<10 5 s). Validation examples for full-core analysis are based on startup experiments for the Watts Bar Nuclear Unit 1 (WBN1) pressurized water reactor (PWR) and two high-temperature gas-cooled reactor (HTGR) benchmarks for the HTR-10 pebble bed and the prismatic HTTR reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SCALE 6.3 Validation: Spent Nuclear Fuel

This report is the fifth volume in a series documenting the validation of SCALE 6.3 with ENDF/B-VII.1 libraries for nuclear criticality safety, reactor physics, radiation shielding, and spent nuclear fuel applications. This fifth volume, which focuses on validating SCALE capabilities that impact spent nuclear fuel applications, provides an update of the similar validation reported for SCALE 6.2.4. The experimental data used as basis for validation herein consist of measurement data for nuclide inventories and decay heat, including the following: 1. radiochemical assay (RCA) measurements of nuclides important to burnup credit, decay heat, and radiation shielding in 205 light-water reactor (LWR) spent nuclear fuel samples that cover burnups ranging up to 80 GWd/MTU and initial fuel enrichments up to 4.9% 235U; 2. full-assembly decay heat measurements for 236 LWR assemblies with initial fuel enrichments ranging up to 4% 235 U, assembly burnups of 5–51 GWd/MTU, and decay times after fuel discharge in the 2- to 27-year range (of importance to spent nuclear fuel storage, transportation, and disposal); and 3. pulse fission irradiations for fissionable materials at cooling times of interest to severe accident analyses (<10 5 s).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of simulated and experimentally measured detector impulse responses to pulsed x-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-toend performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Giant optical nonlinearity of Fermi polarons in atomically thin semiconductors

In this study, realizing strong nonlinear optical responses is a long-standing goal of both fundamental and technological importance. Recently, substantial efforts have been focused on exploring excitons in solids to achieve nonlinearities even down to few-photon levels. However, a crucial tradeoff arises as strong light–matter interactions require large oscillator strength and short radiative lifetime of excitons, which limits their nonlinearity. Here we experimentally demonstrate strong nonlinear optical responses with large oscillator strength by exploiting the coupling between excitons and carriers in an atomically thin semiconductor. By controlling the electric field and electrostatic doping of trilayer WSe 2 , we observe the hybridization between intralayer and interlayer excitons and the formation of Fermi polarons. Substantial optical nonlinearity is observed under continuous-wave and pulsed laser excitation, where the Fermi polaron resonance blueshifts by as much as ~10 meV. Intriguingly, we observe a remarkable asymmetry in the optical nonlinearity between electron and hole doping, which is tunable by the applied electric field. We attribute these features to the optically induced valley polarization due to the interactions between excitons and free charges. Our results establish atomically thin heterostructures as a highly versatile platform for engineering nonlinear optical response with applications to classical and quantum optoelectronics.

2d materials↗