Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “large scale power system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Design and Engineering of LUPIN: A Test-Bed Radio-Frequency Ion Source for Enhanced Neutral Beam Injection on DIII-D

The Large, Uniform Plasma for Ionizing Neutrals (LUPIN) is a radio-frequency (RF) inductively coupled plasma (ICP) chamber for demonstrating plasma performance of an RF ICP positive ion source upgrade for the DIII-D neutral beam injection (NBI) system. LUPIN will be used to investigate ion source physics, including neutral gas dynamics, plasma density uniformity, interactions with Faraday shields, and power coupling to novel RF antenna designs. LUPIN has an RF generator capable of delivering 20 kW of power at 2 MHz, which is coupled into a cylindrical quartz vessel measuring 20 cm in length and 10 cm in radius. This configuration matches the power density requirements for a full-scale ion source. Target hydrogen and deuterium plasma densities exceeding 10 18 m -3 would relate to extracted ion current densities of 2100 A/m 2 for 10s. Vacuum conductance and gas flow calculations predict a maximum achievable neutral gas flow rate of 1675 Pa ⋅ L/s at 5 Pa of He, which mimics the gas flow of the DIII-D NBI system. Designs have been developed for an internal Faraday shield to mitigate heat flux and ion sputtering on the dielectric vessel. Thermomechanical finite element simulations demonstrated the Faraday shield design to be capable of withstanding anticipated heat loads from worst-case operation scenarios. Finally, results of upcoming experimental investigations on LUPIN will guide the design of a full-scale prototype for DIII-D integration.

Faraday shield↗

Modelling the Milky Way – I. Method and first results fitting the thick disc and halo with DES-Y3 data

ABSTRACT We present a technique to fit the stellar components of the Galaxy by comparing Hess Diagrams (HDs) generated from trilegal models to real data. We apply this technique, which we call mwfitting, to photometric data from the first 3 yr of the Dark Energy Survey (DES). After removing regions containing known resolved stellar systems such as globular clusters, dwarf galaxies, nearby galaxies, the Large Magellanic Cloud, and the Sagittarius Stream, our main sample spans a total area of ∼2300 deg2. We further explore a smaller subset (∼1300 deg2) that excludes all regions with known stellar streams and stellar overdensities. Validation tests on synthetic data possessing similar properties to the DES data show that the method is able to recover input parameters with a precision better than 3 per cent. We fit the DES data with an exponential thick disc model and an oblate double power-law halo model. We find that the best-fitting thick disc model has radial and vertical scale heights of 2.67 ± 0.09 kpc and 925 ± 40 pc, respectively. The stellar halo is fit with a broken power-law density profile with an oblateness of 0.75 ± 0.01, an inner index of 1.82 ± 0.08, an outer index of 4.14 ± 0.05, and a break at 18.52 ± 0.27 kpc from the Galactic centre. Several previously discovered stellar overdensities are recovered in the residual stellar density map, showing the reliability of mwfitting in determining the Galactic components. Simulations made with the best-fitting parameters are a promising way to predict Milky Way star counts for surveys such as the LSST and Euclid.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Voltage DC MULTI-terminal SIMulation (HVDC MULTISIM): Technical Program Summary

Expansion of the power grid in the USA is essential to fulfilling the rising energy demand of the country. In particular, the transmission grid, a network of electrical energy corridors that enable the flow of large amounts of energy from the point of generation to the point of consumption, needs significant expansion to cater to this growth of electrification. The current infrastructure is also dated, and any new transmission corridor should be based on a vision of building a modern infrastructure that is futureproof. High voltage DC (HVDC) transmission technology falls in this category: it is the most economical way to build large transmission lines and relies on sophisticated electronics and flexible controls, rather than just passive components like switchgear and transformers. This project is aimed at establishing the technical and economic feasibility of a network of HVDC lines that are interconnected to form a multi-terminal DC network. HVDC transmission is not a new technology and United States has a number of such lines; however, these are point to point transmissions and do not form a DC grid. Modeling and analyzing DC grids is challenging since there are no established modeling tools and the traditional ways of modeling AC grids fall short of providing the fidelity required the fast dynamics of the DC grid. This project aims to build a software-in-the-loop simulator for a multi-terminal HVDC grid, called MULTISIM and, establish new control and protection algorithms to operate such a connected DC system. NLR, a key partner, established the core framework of the MULTISIM simulator and validated its functionality. The GE Vernova team, created a full-scale model of a four-terminal HVDC network using PSCAD (Power Systems Computer Aided Design) software and established the baseline performance of the system during normal and fault operation. The project was started on 10/12024 with a kick-off meeting held on 12/11/2024 and ran through two quarters till termination. All the tasks, milestones and deliverables during this period were met. Several interim reports detailing the various tasks were submitted. The following sections provide details on the completed tasks till the project pause and termination after Q2.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A country-scale green energy-water-hydrogen nexus: Jordan as a case study

Many developing countries suffer from a shortage of clean energy-water production, causing significant dependency on imported fossil fuel to meet the local energy and freshwater demands. Furthermore, when planning a 100 % renewable energy system (RES) to match the energy demand on an hourly basis, the RES is usually oversized. Hence, unavoidable large amounts of excess energy would be generated during hours of high production, low demand, and fully charged energy storage systems (ESSs). Hence, using Jordan as a case study, this work proposes a novel integrated system of wind, solar photovoltaic (PV), and lithium-ion ESS to match 100 % of the country's energy demand while using the excess generated power to drive reverse osmosis water desalination plants to match the demand of freshwater as well. Furthermore, the remaining excess energy is used for producing green hydrogen. A techno-economic optimizer was developed to show that this concept is indeed feasible. Here, the model was used to scan Jordan for the fitting sites of the highest demand-supply matching and the lowest levelized cost of electricity (LCOE), simultaneously. Three different integration scenarios are presented, namely PV-ESS, wind-ESS, and hybrid PV-wind-ESS RESs. The hybrid system showed the best performance, especially compared to the wind-ESS RES, in terms of total installed capacity (33.37 GW), LCOE (0.0492 USD/kWh), specific water cost (0.3629 USD/m 3 ), and energy and water demand-supply fractions (99.47 and 96.16 %, respectively). Storing desalinated water in natural aquifers was found to be a favorable option to enhance the performance of the three systems, where stored water by the end of the year was sufficient to cover the freshwater requirements for several following years. Finally, the remaining excess energy is used to produce green hydrogen with an annual production of up to 1.37 million tons and a specific cost down to 1.08 USD/kg.

14 SOLAR ENERGY↗

Interposed pulsed power system for fast separation of radioactive beams

This paper presents the novel design of an interposed pulsed power system, developed to drive a fast-switching magnet with a large multi-mH load inductance, and high field amplitude (> 1 T). This modulator can produce variable flat-top pulses from 1 to 30 ms with rise and fall times of less than 0.5 ms at a variable duty cycle of 3–91% into a heavily inductive load. The system employs a novel over-voltage topology to overcome the inherent inductance and achieve the fast rise and fall times, switching to a precision DC supply to efficiently maintain the flattop without requiring many-kV voltage. We present a power source design consideration, including the results of computer modeling as well as the first experimental results of a modulator scaled test model will also be presented.

47 OTHER INSTRUMENTATION↗

Quantum Distributed Unit Commitment: An Application in Microgrids

The dawn of quantum computing brings on a revolution in the way combinatorially complex power system problems such as Unit Commitment are solved. The Unit Commitment problem complexity is expected to increase in the future because of the trend toward the increase of penetration of intermittent renewables. Even though quantum computing has proven effective for solving a host of problems, its applications for power systems’ problems have been rather limited. Here, in this paper, a quantum unit commitment is innovatively formulated and the quantum version of the decomposition and coordination alternate direction method of multipliers (ADMM) is established. The above is achieved by devising quantum algorithms and by exploiting the superposition and entanglement of quantum bits (qubits) for solving subproblems, which are then coordinated through ADMM to obtain feasible solutions. The main contributions of this paper include: 1) the innovative development of a quantum model for Unit Commitment; 2) development of decomposition and coordination-supported framework which paves the way for the utilization of limited quantum resources to potentially solve the large-scale discrete optimization problems; 3) devising the novel quantum distributed unit commitment (QDUC) to solve the problem in a larger scale than currently available quantum computers are capable of solving. The QDUC results are compared with those from its classical counterpart, which validate the efficacy of quantum computing.

97 MATHEMATICS AND COMPUTING↗

Molecular concentration field design using closed-form steady-state solutions

Control over spatial concentration fields represents a fundamental challenge in designing synthetic biological systems and programmable soft materials. While nature creates morphogen gradients that orchestrate complex developmental processes, synthetic approaches have largely relied on empirical optimization and computationally intensive simulations. Here, we present an analytical framework for steady-state concentration fields generated by finite-sized localized sources in diffusion–degradation systems and derive closed-form solutions for one-, two-, and three-dimensional geometries. By expressing these solutions in dimensionless form, we show that gradient steepness and spatial structure are organized by the Thiele modulus, which captures the competition between diffusion and degradation length scales. The analysis reveals distinct design regimes: in degradation-dominated systems, gradient shape is governed by exponential decay and becomes dimension-independent, whereas in diffusion-dominated systems, gradient magnitude and extent follow dimension-dependent power-law scaling. Building on these results, we introduce a quantitative design strategy that uses threshold-based criteria to program concentration ranges by tuning physically accessible parameters, most directly the production rate, while holding transport and degradation properties fixed. Comparisons with numerical solutions and reported experimental systems demonstrate consistency with the predicted scaling behavior. Together, this work provides a generalizable and physically transparent framework for designing steady-state concentration fields in synthetic biological and soft matter systems, enabling predictive control of gradient-mediated organization without reliance on extensive numerical optimization.

Kim, Dong Woo [Johns Hopkins University, Baltimore↗

Material aspects of giga-Hertz ZnO TFTs for wireless systems

Abstract Having enabled high-value application capabilities through mass production of flat-panel displays, X-ray imagers, and solar panels, Large-Area Electronics (LAE) holds potential to open new frontiers in wireless applications for the Internet of Things and 5G/6G, by enabling unprecedented spatial control and power efficiency through large size and flexible form factor of radiative apertures. However, this requires boosting operation frequencies from the traditional limits in the range of 10–100’s of mega-Hertz to multi giga-Hertz. In this paper, we discuss critical device metrics, to characterize zinc-oxide (ZnO) thin-film transistor (TFT) operation frequency for both active (for signal amplification) and passive components in LAE-based circuits and systems. We then describe the key structural and material approaches towards recently demonstrated LAE-based giga-Hertz wireless systems employing ZnO TFTs. Bringing LAE to the giga-Hertz regime provides a path towards flexible and meter-scale monolithic integrated wireless systems. Graphical abstract

Ma, Yue (ORCID:0000000186724090)↗

Real-time Intrusion Detection for High-bandwidth Research Networks using Unsupervised Deep Learning

Nowadays, data generated by large-scale scientific experiments are on the scale of petabytes per month. These data are transferred through dedicated high-bandwidth networks across distributed collaboration sites for processing, storage, and analysis. Like general purpose networks, research networks experience attacks. However, monitoring traffic in such high-bandwidth network environments is challenging with conventional deep packet inspection (DPI)- based network intrusion detection systems (NIDS). Recently, machine learning (ML) algorithms have shown potential in detecting anomalous patterns with better generalizability and faster speed. Compared to the general purpose networks, traffic movement in research network is less volatile and more likely to benefit from the ML-based anomaly analysis. We present ThunderSecure, an efficient AI-powered system for detecting anomalies in 100G research networks. ThunderSecure implements a high-throughput packet processing infrastructure using multi-cores and GPUs. It takes time-series statistics from a variety of network measurements and uses 2D Convolutional Neural Network (CNN) to explore both spatial and temporal dependencies in network data stream. Patterns of science data traffic are learned with a one-class neural network, which blends an Adversarial Autoencoder (AAE) with Gaussian mixture density estimation. Testing traffic flows exhibiting significant deviations from the learned baseline of normality are marked as anomalies. We trained ThunderSecure on hundreds of billions of science data packets recorded from a 100G research network at Fermi National Accelerator Laboratory. The detection performance was evaluated on traffic captured from the same research network days and weeks after the training with different types of attack flows injected. To the best of our knowledge, this is the first ML work in the area of network anomaly detection that has been validated on such extreme scale datasets. Results show that ThunderSecure can recognize science data traffic that are captured long after the training and make nearly certain detection on those with anomalous flows injected, even in the case when the anomaly-to-normal mixing ratio is 0.1%.

Gong, Qian↗

Concentrating Rare Earth Elements in Coal mine drainage Using Coal Combustion Products through Abandoned Mine Land Reclamation

Rare earth elements (REEs) (including scandium, yttrium and a group of 15 lanthanides) are often considered to be critical components in the productions of renewable energy hardware, electric vehicles, health care and military equipment, and consumer electronic products. The demand of REEs has been projected to be growing at an annual rate of 5-9% in the next 25 years. In 2011, the global demand of total rare earth oxides (REOs) was estimated to be approximately 105,000 tons, which is expected to grow to 210,000 tons by 2025. China overwhelmingly dominates the current worldwide rare earth productions but has strategically restricted its exports, causing significant instability for the global market. In response to the increasing demand for REEs and the supply dominance of China, identifying alternative sources of REEs has become a critical issue for the United States and other countries. Coal, coal ash, and coal mine drainage (CMD) are considered to be the alternative sources of REEs. In the U.S., high REE concentrations have been reported to be closely associated with coal deposits, including the Appalachian Basins. When surface and/or groundwater come in contact with geologic strata containing sulfide minerals exposed by coal mining, the accelerated oxidation of sulfide minerals in the presence of ferric iron and/or oxygen can produce sulfuric acid. The process promotes the weathering of REE-bearing rocks and minerals in the host geologic strata. Compared to average river water and seawater, the concentrations of REEs can be orders of magnitude higher in CMD. In this study, we demonstrated a trap-extract-precipitate (TEP) process that can effectively recover REEs from CMD. The three-stage TEP process uses alkaline industrial by-products to capture REEs from CMD and then applies an extraction/precipitation procedure to produce a feedstock that can be economically processed to produce marketable rare earth oxides. The alkaline industrial by-products tested in this study include the residual from a water softening process (DRWP sludge) and two types of stabilized flue gas desulfurization materials (sFGDs). sFGD material is a mixture of lime (CaO) and two coal combustion by-products, calcium sulfite FGD by-product and fly ash. The objectives of this study are to (1) validate the effectiveness and feasibility; (2) determine mechanisms controlling the rare earth recovery, (3) quantify the associated economic and environmental benefits, and (4) evaluate the full-scale application. To achieve these objectives, tasks to be carried out in this proposed project are organized into three phases. In the first phase, the research team collaborated with Ohio Department of Natural Resources, American Electric Power, The Wilds (a nonprofit wildlife conservation organization), and a private landowner to carry out field investigations aimed to screen and evaluate the seasonal changes of rare earths in the CMD discharges that have high recovery potentials. Next, the recovery of REEs from CMD was tested using a series of lab-scale column and batch tests under, respectively, percolation and completely mixed conditions. Results obtained from these lab-scale studies show that all three tested solids are very effective in retaining REEs. Over 98% of the CMD REEs that contacted the solids were captured before the solids exhausted their neutralization capacities. We also determined an extraction process using a non-acid, organic ligand extraction solution that can effectively remobilize the retained REEs from the spent solids (over 90%). The REE concentrate (>7.5 wt. % of total REEs) is then formed in an aeration process. The TEP process uses environmentally benign industrial by-products and a naturally-occurring organic ligand to mitigate CMD and recover REEs. Techno-economic analysis (TEA) and life-cycle assessment (LCA) was carried out in the third phase. The engineering-economic costs and net energy, net CO2 emissions, and water and other requirements were investigated to understand the economic and environmental implications of this process. This work uses mass and energy balances from laboratory-scale experiments to estimate the economic costs and environmental impacts. The results suggest that passive treatment systems that use DRWP sludge are preferred over those that use sFGD material, because of lower economic costs ($89,300/yr with a unit cost of $86/gT-REE vs. $89,800/yr, or $278/gT-REE) and improved environmental performance across all indicators from two different impact assessment methods. These differences are largely attributable to the larger capacity of DRWP sludge in the passive treatment application. We envision this TEP process can be integrated with abandoned mine land (AML) reclamation to create an approach that can add economic incentives for AML reclamation, remediate CMD discharge, and eliminate public safety hazards and threats to local environment and ecological systems posed by AMLs. It can restore lands and communities that are adversely impacted by legacy mining.

01 COAL, LIGNITE, AND PEAT↗

Scalability of Real-time Distribution Models

This work will focus on developing the capabilities and validating the models for a sub transmission network with multiple feeders and microgrids. To achieve this scale of Hardware-in-the-loop (HitL) simulation, it is necessary to federate and collaborate. The work aims to design the large-scale feeder models to allow federation with complementary testbeds in the future. The feeder would be designed to be reconfigurable to put the system into a variety of modes. Aggregators models will be included in each distribution network’s federate to take control actions and interact with the management systems. Lastly, the feeder model will support large scale resilience studies involving complex Distributed Energy Resources (DER) controls, microgrid studies and emulation of complex data flows in future grid architectures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing and Exploring Untapped Micro-Hydro Hybrid Systems: a Multi-Objective Approach for Crystal Lake as a Large-Scale Energy Storage Solution

Increasing electricity demand and concerns about climate change and fossil fuel consumption have highlighted the importance of renewable energy resources and storage systems. This paper proposes a method for exploring untapped pumped hydro storage potentials to accommodate intermittent renewable energy generation profiles. Hourly measured data from 2022 in Benzie County, Michigan, United States, were gathered for system sizing and a thorough, realistic analysis. By employing the multi-objective grey wolf optimization algorithm, we formulated optimal sizing and energy-management strategies for three different scenarios. Unlike similar studies, the 3rd with triple objective functions (OFs) scenario aims to maximize both reliability and ecological OFs while minimizing the cost OF. It has shown promising results with multiple solutions, considering economic, environmental, and reliability factors. A case study conducted in Crystal Lake, Michigan, revealed that although Crystal Lake would function only as a micro-hydro power facility, it is a promising and huge storage unit with a substantial storage capacity of around 14.9734GWh. The system investigated is significant in the USA due to its rapid deployment capabilities, minimal construction requirements, and ease of integration with the distribution grid. The fuzzy logic method was employed to identify the best non-dominant solution among the other solutions. Furthermore, these outcomes include a notably low levelized cost of energy at 0.046147$/kWh, a robust index of reliability of 99.705%, and a significant reduction in CO₂ emissions amounting to 7.9142×10 3 tons/year, when considering the triple OFs. The paper’s methodology provides valuable insights for regions aiming to utilize renewable energy from untapped storage sources.

13 HYDRO ENERGY↗

Distribution Market-Clearing and Pricing Considering Coordination of DSOs and ISO: An EPEC Approach

Distribution-level electricity market provides a platform for trading energy and grid services from large-amount of small-scale distributed energy resources (DERs) located on distribution grids. The behavior of the DERs in the distribution electricity market may ultimately impact the market-clearing and locational marginal prices (LMPs) in the wholesale market. This paper proposes a bi-level optimization model for distribution market clearing and distribution locational marginal pricing (DLMP) considering the interactions between distribution and transmission wholesale markets. In the proposed model, the upper-level model represents the distribution system operator (DSO) market-clearing and the lower-level model represents the wholesale market-clearing by the independent system operator (ISO). The LMP at the substation will impact the DER dispatch and power demands of the DSO as well as the DLMP. In turn, the power demands of the DSO will further impact the ISO market and its LMPs. The equilibrium problem with equilibrium constraints (EPEC) approach is applied to find the equilibria of multiple DSOs and the ISO. The EPEC problem is transformed into a single-level mixed-integer convex problem in order to allow for efficient solving. Finally, the effectiveness of the proposed model and solution method are demonstrated through case studies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Kilauea Magnetotelluric Dataset

In 2002 and 2003 a collaborative effort was undertaken between Lawrence Berkeley National Laboratory, Sandia National Laboratories, the USGS Menlo Park, the USGS Hawaiian Volcano Observatory, and Electromagnetic Instruments Inc. to study the Kilauea volcano in Hawaii using the magnetotelluric (MT) technique. The work was motivated by a desire to improve understanding of the magma reservoirs and conduits within Kilauea and the East and Southwest Rift zones, which has implications for understanding Kilaueas plumbing system. An improved understanding of the rift zones has implications in understanding large-scale landslides that are generated in the Hilina Slump, which produce significant impacts on coastal communities. Up to eight stations operated simultaneously, with multiple remote reference sites, and data were processed using multi-station robust processing techniques. In total, data were acquired at 70 sites over the Southwest and East rift zones. Good to excellent quality data were obtained even in the harshest conditions, such as those encountered on the fresh lava flows of the East Rift Zone (ERZ), where electrical contact resistances are on the order of 100 kOhm. This data supports the continuing efforts to increase geothermal power on the island of Hawaii. Each of the 70 EDI files are the MT impedance tensors for 1 site. There is also a description of the processing of the data and a site map showing the locations of each site.

15 GEOTHERMAL ENERGY↗

Enhancement of Optical Efficiency of CSP Mirrors for Reducing O&M Cost via Near-Continuous Operation of Self-Cleaning Electrodynamic Screens (EDS). Final Report

Over the past decade, techno-economical advancements in solar energy systems, particularly the improvement in the conversion efficiency of PV modules made with mono-crystalline silicon solar cells from 12% to 20%, as well as the cost reduction in manufacturing by a factor of about 10%, have made it possible to achieve a levelized cost of electricity (LCOE) in PV plants that is comparable to, or less than, the cost of deriving electricity from fossil fuels. Operating PV plants in mid-latitude sun-belt regions, where the solar irradiance level is highest, provides a high annual energy-yield (kWh/kWp) due to two factors: (1) the availability of predictable high solar irradiance throughout the year with the fewest interruptions in solar flux from clouds and rain, and (2) the increased conversion efficiency of crystalline solar cells, as recombination loss has decreased with increased intensity of the sunlight that illuminates the silicon solar cells. Semi-arid and desert regions, however, are plagued by high atmospheric dust concentrations and frequent sand storms. The deposition of a layer of dust on the optical surfaces of solar collectors such as PV modules and concentrating mirrors reduces the transmission efficiency of sunlight that actually reaches the solar cells or receivers, resulting in high energy-yield soiling loss. There are two major cost components to operating a solar plant: (1) installation costs, and (2) operation-and-maintenance (O&M) costs. There is no fuel cost; hence operating a solar plant in a semi-arid or desert region provides high returns on investment if soiling losses are mitigated via efficient cleaning methods and optimized cleaning frequency. If solar collectors are not cleaned, the accumulation of dust layers on solar collectors may cause the operation of such plants in arid regions to become economically unviable. Washing solar collectors with water and detergent, as is most commonly done now, is an efficient method for cleaning. The conventional approach in utility-scale solar plants is to use a large truck with a water tank and pump system for spraying deionized water on the surface of the solar collectors. Robotic cleaning with brushes, used for many solar plants, requires lesser water for cleaning. The water consumed using semi-automated cleaning of PV modules in utility-scale solar plants is approximately 2 liters/m 2 per cleaning cycle. The total optical surface area of the solar collectors in 1 TW-scale solar installation will be more than 3 × 109 m 2 ; hence an enormous amount of water be needed for cleaning. There simply is not enough fresh water in the sun-belt areas of the world for predicted cleaning needs. In solar power plants, the estimated cost of cleaning solar collectors includes expenses related to the equipment used, labor, cost of transportation of water, the energy required for cleaning, plus ancillary costs whereas the cost of water is not considered. The water used is obtained from sources located close to plant sites, unmindful of the environmental and societal impact as the power plants are oftentimes located in regions that face severe drought. This practice is very similar to the cost calculations in deriving the levelized cost of electricity (LCOE) in conventional power plants based on burning fossil fuel such as coal and gas, while disregarding the cost of climate change and health effects. Unless a water-free or low-water cleaning method is established, the expansion of solar plants may lose public support in areas suffering long intervals of drought. The goal of this research project has been the development and application of the Electrodynamic Screen (EDS) as a means for a water-free, scalable cleaning process applicable to solar-power installations, including rooftop applications. We describe here the development of an EDS film-based cleaning process as an emerging method for use on PV modules, parabolic troughs, and heliostats. This report aims to show the feasibility of integrating or retrofitting EDS films onto the optical surfaces of solar collectors (both PV and CSP) while maintaining high transmission or reflection efficiency. The cleaning action provided by the EDS film is an active method to remove dust deposits by electrodynamic force. Current lab-scale prototype EDS films, retrofitted onto solar panels and mirrors, have shown to be capable of maintaining optical transmission or specular-reflection efficiencies higher than 90% of initial values under clean conditions. The optical surfaces of solar collectors laminated with EDS films can remove more than 90% of deposited dust when the EDS is activated for less than two minutes. As an electrodynamic dust removal process, the EDS film-based method is designed primarily for the removal of dust in solar installations located in semi-arid and desert areas, where the atmosphere is often dry and dusty and rainfall is infrequent. While EDS film application minimizes water consumption and facilitates cleaning as frequently as needed, it has limitations in removing contaminants such as soot, organic pollutants deposited as fine films on the surface, and bird droppings. The dust removal efficiency of the EDS is maximum at relative humidity RH is 40 to 50% and decreases at when RH > 65%. Many solar plant sites undergo diurnal and seasonal cycles of high ambient, early afternoon temperatures and an RH that reaches the dew point early in the morning. These variations in atmospheric conditions do not limit the operation of the EDS film. This report presents a brief review of the progress and the potential of EDS film technology for mitigating the impact of dust on solar collectors via water-free cleaning, as well as current technical challenges regarding efficiency and durability. Our experimental data on the performance of EDS films show that: (1) the dust-removal efficiency (DRE) can reach levels higher than 90%, (2) the specular reflectivity (SR) of EDS film-laminated second-surface mirrors reach levels in excess of 90%, (3) the specular reflectivity restoration (SRR) can exceed 90%, (4) the output-power restoration (OPR) of PV modules can exceed 95%, and (5) the optical transmission efficiency (TE) of the EDS films can be greater than 90%. Working with Sandia National Laboratories (NM), Corning Research and Development Corporation (NY), Eastman Kodak (NY), Tomark-Worthen Industries (NH), and EDS Chile SPA (Chile), we have produced EDS film-laminated PV modules and demonstrated their self-cleaning functions without requiring water. We have demonstrated that the operational range of EDS films will cover the expected ambient temperature of solar fields at RH cycling varying from 20 to 95% as long as the EDS films are activated in the RH range 20 to 50%. (Typical solar-field climates in deserts and semi-arid lands often reach near dew point in coastal areas.) Our experiments on the application of hydrophobic-fluorinated nanoparticle coatings on EDS film surfaces show that the EDS operational range can be extended to higher RH levels that approach the dew point. At Eastman Kodak, as one of our industrial partners, we were able to establish a process for manufacturing EDS films using flexographic printing of the electrodes onto transparent polymer films. This process utilizes an existing manufacturing line at Eastman Kodak that allows fabrication of medium-scale EDS films (26 cm × 30 cm). The manufacturing process has the capacity to produce EDS films at high production speeds. The medium-scale EDS films that have been printed at Kodak were evaluated in the lab at Boston University. The EDS films produced at Kodak were laminated at Tomark-Worthen using an industrial scale vacuum laminator to produce EDS film stacks, which can be affixed onto the optical surfaces of PV modules or concentrating mirrors. The EDS film stack consists of the EDS films that have Willow® Glass (WG) which has a thickness of 100 μm as the front surface. The WG sheets obtained from Corning Research and Development Corporation are customized in size and shape to cover the active area of the EDS films. The back surface of the EDS film stack is integrated onto the optical surface of the solar panel or mirror using optically clear adhesive (OCA) films or silicone adhesives. The OCA films (thickness 25 μm) are produced by 3M. The EDS film stacks have the architecture: WG/OCA/EDS Film/OCA/ over PV module or solar mirror. The power-supply units needed for activating the electrodes of the EDS film were designed and produced at Boston University. These power supply units provide three-phase, 1.2 kV voltage pulses at a very low current (micro-ampere) level and at a low frequency (≈ 5 Hz). The voltage pulses are applied to the electrodes in a sequence such that the train of pulses resembles a unidirectional traveling wave of electrical field on the surface of the EDS film. The dust particles on the surface become charged electrostatically and are levitated by the Coulomb force. The lateral sweeping action of the traveling electric field created by the three-phase voltages pulses then sweeps the dust off the surface. The energy consumed by the EDS electrodes is less than 0.2 Wh/m 2 /cleaning cycle, enabling energy-efficient restoration of output power (OPR) of PV module or specular reflectivity restoration (SRR) for solar mirrors. The EDS system consists of (1) an EDS film stack laminated onto the solar collectors, (2) connection of the EDS film to its power supply unit and (3) Interconnection of the power supply to PV modules or solar mirrors. Design, construction and assessment of field-testing units that have EDS stack laminated PV modules for evaluating the performance of the EDS films in solar fields is being carried out at BU. Our progress under this project, aimed at the advancement of EDS film technology, has reached DOE Technology Readiness Level (TRL) 6. Based on the extensive laboratory evaluations and limited field trials, as well as contacts with potential users, we believe that the technology has reached its commercial stage. We are conducting a cost analysis using the National Renewable Energy Laboratory (NREL) System Advisory Model (SAM) and are preparing for field trials of EDS films in different solar fields in the US, Chile, India and in the Middle East. A brief description of EDS film performance, construction and testing of the field-test unit, autonomous operation of the field-test unit for evaluating EDS performance in increasing energy yield, associated revenue savings, and water conservation is presented.

14 SOLAR ENERGY↗

Integrated Reliability and Economic Modeling for Transmission Across Large Regions: A Space Odyssey

Power flow modeling and stability analysis are needed to more-comprehensively assess system reliability but the development of the system portfolios and conditions require use of economic models (e.g., production cost). What are the state of art methods for efficiently linking economic and reliability models to enable examination of multiple snapshots and perform detailed nodal analyses?

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV backsheets survey protocol: A framework for geo-spatial field surveys for bulk material characterization and reliability analysis applied across 41 PV systems

As widespread adoption of photovoltaic (PV) technologies continues, understanding the lifetime of modules is paramount to the viability of the industry as an environmentally conscious alternative to traditional energy generation. Although power degradation can affect the total energy production of a module over its lifetime, module safety failures necessitate the removal of a module leading to a loss of not only the particular asset, but the earning potential of the device. Therefore, it is critical to ensure that the components that provide essential safety functions for PV module operate for their entire rated lifetime. PV backsheets provide necessary electrical insulation to the completed device and failure of this component is cause for a immediate removal of the module. Degradation of the PV module backsheet has led to module safety failures in large-scale installations, costing millions of dollars in damages and lost potential revenue. The spatio-temporal degradation of fielded PV modules is important to study in order to identify which modules within installations are experiencing the greatest exposure conditions and in turn have the highest chance of failure. This paper describes a comprehensive field survey protocol developed for monitoring PV module backsheet performance using solely non-destructive methods in commercial PV fields. The protocol establishes a field naming convention, sampling method, data handling requirements, and measurement procedures. By ensuring consistent data collection practices, the field survey protocol enables research groups to obtain data of uniform quality on backsheet performance over multiple years and locations. In this study, the developed protocol was implemented at forty-one PV sites. Eight different types of airside layer backsheet materials including poly(vinylidene fluoride) (PVDF), acrylic PVDF, poly(tetrafluoroethylene-co-hexafluoropropylene-co-vinylidene fluoride) (THV), poly(vinyl fluoride) (PVF), poly(ethylene terephthalate) (PET), fluoroethylene vinyl ether (FEVE), polyethylene naphthalate (PEN), and glass were identified using attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. The field survey results show that the spatial distribution of degradation indicators are non-uniform within a particular module, individual site, and across site locations. The degradation of PV modules increased in severity for modules mounted at the edge of rows (across a field) and near the junction box (within a module). This study demonstrates the sensitivity of material performance to exposure length across different materials and climates.

14 SOLAR ENERGY↗

Learning Latent Interactions for Event Identification via Graph Neural Networks and PMU Data

Phasor measurement units (PMUs) are being widely installed on power systems, providing a unique opportunity to enhance wide-area situational awareness. One essential application is the use of PMU data for real-time event identification. However, how to take full advantage of all PMU data in event identification is still an open problem. Thus, we propose a novel method that performs event identification by mining interaction graphs among different PMUs. The proposed interaction graph inference method follows an entirely data-driven manner without knowing the physical topology. Moreover, unlike previous works that treat interactive learning and event identification as two different stages, our method learns interactions jointly with the identification task, thereby improving the accuracy of graph learning and ensuring seamless integration between the two stages. Moreover, to capture multi-scale event patterns, a dilated inception-based method is investigated to perform feature extraction of PMU data. To test the proposed data-driven approach, a large real-world dataset from tens of PMU sources and the corresponding event logs have been utilized in this work. We report numerical results validate that our method has higher classification accuracy compared to previous methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗