Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imager”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Guide for Atomic Force Microscopy Image Analysis To Discriminate Heteroatoms in Aromatic Molecules [A Guide for AFM Image Analysis To Discriminate Heteroatoms in Aromatic Molecules]

Heteroatoms are essential for functional groups in organic structures and are complementary to hydrocarbon molecules in reactivities and properties. However, it is still a challenge to quickly identify heteroatoms with only non-contact atomic force microscopy (nc-AFM) to resolve chemical structures in complex unknown mixtures. This study aimed to understand the effect of elemental types on the contrast of atomic force microscopy (AFM) images using a few selected model heterocycles, including dibenzothiophene (DBT), acridine (ACR), and carbazole (CBZ). We identified several features that can be used to find common heteroatoms (S and N) and discriminated them from carbon atoms (C) using nc-AFM images alone. The mechanism of the atom and bond contrast was studied with image simulations and was found to be mostly correlated to van der Waals radii, but other factors, such as bonding geometry, electron density, and substrate interaction, need to be considered. As a result, this work will allow for rapid identification of these common heteroatoms in petroleum with AFM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging Consecutive Steps of O2 Reaction with Hydroxylated TiO2(110): Identification of HO2 and Terminal OH Intermediates

The hydroperoxyl (HO2) species is believed to be a key intermediate in many heterogeneous photochemical processes, but generally metastable and thus hard to prove. We report here that for the first time, we directly imaged stable, adsorbed HO2 species during O2 reaction with a partially hydroxylated TiO2(110). We also found terminal hydroxyl groups, another critical but never directly observed intermediates. By imaging species and tracking site-specific reactions with high-resolution scanning tunneling microscopy, and determining the energies and configurations with density functional theory calculations, we provide molecular-level insight into the underlying reaction mechanisms. These results are expected to have far reaching implications for various catalytic systems involving the interconversion of O2 and H2O.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-matrix, dual polarity, tandem mass spectrometry imaging strategy applied to a germinated maize seed: toward mass spectrometry imaging of an untargeted metabolome

Mass spectrometry imaging (MSI) provides high spatial resolution information that is unprecedented in traditional metabolomics analyses; however, the molecular coverage is often limited to a handful of compounds and is insufficient to understand overall metabolomic changes of a biological system. Here, we propose an MSI methodology to increase the diversity of chemical compounds that can be imaged and identified, in order to eventually perform untargeted metabolomic analysis using MSI. We use the desorption/ionization bias of various matrixes for different metabolite classes along with dual polarities and a tandem MSI strategy. The use of multiple matrixes and dual polarities allows us to visualize various classes of compounds, while data-dependent MS/MS spectra acquired in the same MSI scans allow us to identify the compounds directly on the tissue. In a proof of concept application to a germinated corn seed, a total of 166 unique ions were determined to have high-quality MS/MS spectra, without counting structural isomers, of which 52 were identified as unique compounds. According to an estimation based on precursor MSI datasets, we expect over five hundred metabolites could be potentially identified and visualized once all experimental conditions are optimized and an MS/MS library is available. Finally, metabolites involved in the glycolysis pathway and tricarboxylic acid cycle were imaged to demonstrate the potential of this technology to better understand metabolic biology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intracellular Dynamics of Superparamagnetic Iron Oxide Nanoparticles for Magnetic Partical Imaging

Superparamagnetic iron oxide nanoparticles (SPIONs) are a foundational platform for a variety of biomedical applications. Of particular interest is Magnetic Particle Imaging (MPI), which is a growing area of research and development due to its advantages including high resolution and sensitivity with positive contrast. There has been signicant work in the area of in vivo optimization of SPIONs for MPI as well as their biodistribution in and clearance from the body. However, little is known about the dynamics of SPIONs following cellular internalization which may limit their usefulness in a variety of potential imaging and treatment applications. This work shows a clear 20% decrease in magnetic performance of SPIONs, as observed by Magnetic Particle Spectroscopy (MPS), after internalization and systematic consideration of applicable factors that aect SPION signal generation, including microstructure, environment, and interparticle interactions. There is no observed change to SPION microstructure after internalization, and the surrounding environment plays little to no role in magnetic response for the SPIONs studied here. Interparticle interactions described by dipole-dipole coupling of SPIONs held close to one another after internalization are shown to be the dominant cause of decreased magnetic performance in cells. These conclusions were drawn from transmission electron microscopy (TEM) image analysis at relevant length scales, experimentally prepared and characterized SPIONs in varied environmental conditions, and theoretical modeling with Monte Carlo simulations.

Teeman, Eric M.↗

Summary of the first neutron image data collected at the National Ignition Facility

A summary of data and results from the first neutron images produced by the National Ignition Facility (NIF), Lawrence Livermore National Laboratory, Livermore, CA, USA are presented. An overview of the neutron imaging technique is presented, as well as a synopsis of the data collected and measurements made to date. Data form directly driven, DT filled microballoons, as well as, indirectly driven, cryogenically layered ignition experiments are presented. The data presented show that the primary cores from directly driven implosions are approximately twice as large, 64 {+-} 3 {mu}m, as indirect cores 25 {+-} 4 and 29 {+-} 4 {mu}m and more asymmetric, P2/P0 = 47% vs. -14% and 7%. Further, comparison with the size and shape of X-ray image data on the same implosions show good agreement, indicating X-ray emission is dominated by the hot regions of the implosion.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Three-dimensional velocity map imaging: Setup and resolution improvement compared to three-dimensional ion imaging

For many years the three-dimensional (3D) ion imaging technique has not benefited from the introduction of ion optics into the field of imaging in molecular dynamics. Thus, a lower resolution of kinetic energy as in comparable techniques making use of inhomogeneous electric fields was inevitable. This was basically due to the fact that a homogeneous electric field was needed in order to obtain the velocity component in the direction of the time of flight spectrometer axis. In our approach we superimpose an Einzel lens field with the homogeneous field. We use a simulation based technique to account for the distortion of the ion cloud caused by the inhomogeneous field. In order to demonstrate the gain in kinetic energy resolution compared to conventional 3D Ion Imaging, we use the spatial distribution of H{sup +} ions emerging from the photodissociation of HCl following the two photon excitation to the V {sup 1}{Sigma}{sup +} state. So far a figure of merit of approximately four has been achieved, which means in absolute numbers {Delta}v/v=0.022 compared to 0.086 at v{approx_equal}17 000 m/s. However, this is not a theoretical limit of the technique, but due to our rather short TOF spectrometer (15 cm). The photodissociation of HBr near 243 nm has been used to recognize and eliminate systematic deviations between the simulation and the experimentally observed distribution. The technique has also proven to be essential for the precise measurement of translationally cold distributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging divertor strike point splitting in RMP ELM suppression experiments in the DIII-D tokamak [Imaging divertor strike point splitting in RMP ELM suppression experiments]

Fast visible imaging of the lower divertor from above is used to study the structure and dynamics of lobes induced by resonant magnetic perturbations (RMPs) in Edge-Localized Mode (ELM) suppression experiments in DIII-D. The best compromise between the amount of light and sharp imaging was obtained using emission at 601 nm from Fulcher band molecular deuterium. Multiple spatially resolved peaks in the D 2 emission, taken as a proxy for the particle flux, are readily resolved during RMPs, in contrast to the heat flux measured by infrared cameras, which shows little spatial structure in ITER-like conditions. The 25 mm objective lens provides high spatial resolution (2–4 mm/pixel) from the centerpost to the outer shelf over 40° toroidally that overlaps the field of view of the IRTV that measures the divertor heat flux, allowing direct comparison in non-axisymmetric discharges. The image is coupled to a Phantom 7.3 camera using a Schott wound fiber bundle, providing high temporal resolution that allows the lobe dynamics to be resolved between ELMs and across ELM suppression onset. Furthermore, these measurements are used to study the heat and particle flux in 3D magnetic fields and to validate models for the plasma response to RMPs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Motional Stark effect imaging first results on the DIII-D tokamak

A motional Stark effect (MSE) imaging diagnostic was benchmarked against existing conventional MSE polarimeters on the DIII-D tokamak and delivered new capabilities for measuring the magnetic pitch angle from 2 neutral beams and on the high field side of DIII-D. Line integration across flux surfaces was considerable for the radial view utilised; yet, the imaging MSE measurements from both beams were self-consistent and in close agreement with conventional MSE measurements. The ferroelectric liquid crystal waveplate used in the imaging polarimeter was discovered to have spatially non-uniform retardance; thus, it is required for the calibration source to replicate the ray paths of the neutral beam emission through the optical system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fresnel zone plate point spread function approximation for zeroth order mitigation in millimetric field of view x-ray imaging

High spatial and temporal resolution x-ray radiography images are required at the National Ignition Facility (NIF) for high-energy density experiments. One technique that is in development to achieve the required resolution uses Fresnel zone plate (FZP) optics to image an object that is backlit by an x-ray source. The multiple FZP diffraction orders do not focus on the same plane, which increases the background and reduces the contrast. Understanding the point spread function of the different diffraction orders will allow the prediction of the expected background using simulations. We find that the two-dimensional point spread function of the FZP can be approximated by the addition of a sharp Gaussian with a disk. This allowed for the estimation of the background in NIF experimental images of Rayleigh–Taylor spikes and their interpretation. An alternative design of FZP is discussed to allow the inclusion of a zeroth order blocker to reduce the background.

Do, A. (ORCID:0000000174372147)↗

High-speed Synchrotron X-ray Imaging of Laser Powder Bed Fusion Process

In additive manufacturing (AM) processes, materials are selectively added in layer-wise fashion to build three-dimensional objects. This approach provides several advantages over conventional manufacturing, including the ability to manufacture complex parts, design flexibility, shorter lead times, reduced inventory of spares, and on-demand manufacturing [1]. With these advantages, applications of AM are increasing rapidly in the medical, aerospace, automobile, and defense industries [2, 3]. Currently, laser powder bed fusion (LPBF) is the most extensively used AM technique for manufacturing metal parts. In a typical LPBF process, a high-power laser beam is scanned across a thin layer of powder, melting and subsequently fusing it to the previous layer. Highly transient interactions between the laser, powder particles, and the bottom layer lead to defects in the AM materials. These defects include porosity, residual stresses, surface roughness, and undesirable microstructures [1, 4]. Additionally, several in situ techniques have been developed to capture these interactions in real time, including high-speed visible light and infra-red imaging [5]. However these techniques are limited to surface observations. Most of the important phenomena that govern the quality of the AM parts, such as dynamics of the vapor depression and melt pool, occur sub-surface and hence cannot be captured using traditional optical techniques. Recently, a synchrotron-based high-speed X-ray imaging technique has been developed to record the sub-surface dynamics of metallic materials during the LPBF process. The unprecedented spatial and temporal resolutions afforded by the synchrotron sources allow direct observation of many important phenomena in AM for the first time [6–9]. Further, high-speed X-ray diffraction and optical imaging techniques are also being applied to capture the crystallographic and thermal information of the material, respectively, as they undergo melting, solidification, and cooling [6, 9]. In this contribution, we introduce the recent developments at the Advanced Photon Source (APS) for in situ and operando study of LPBF processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetized Plasma for Reconfigurable Subdiffraction Imaging

We show that magnetized plasma with appropriately designed parameters supports nearly diffractionless propagation of electromagnetic waves along the direction of the applied magnetic field, arising from their unbounded equifrequency contour in the magnetized plasma. Such a unique feature can be utilized to construct subdiffraction imaging devices, which is confirmed by detailed numerical investigations. Subdiffraction imaging devices based on magnetic plasma do not require microfabrication normally entailed by construction of metamaterials; more importantly, they can be dynamically reconfigured by tuning the applied magnetic field or the plasma density, and therefore they represent a facile and powerful route for imaging applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-BRF-14: Increasing the Accuracy of Dose Calculation On Cone-Beam Imaging Using Deformable Image Registration in the Case of Prostate Translation

Purpose: Artifacts can reduce the quality of dose re-calculations on CBCT scans during a treatment. The aim of this project is to correct the CBCT images in order to allow for more accurate and exact dose calculations in the case of a translation of the tumor in prostate cancer. Methods: Our approach is to develop strategies based on deformable image registration algorithms using the elastix software (Klein et al., 2010) to register the treatment planning CT on a daily CBCT scan taken during treatment. Sets of images are provided by a 3D deformable phantom and comprise two CT and two CBCT scans: one of both with the reference anatomy and the others with known deformations (i.e. translations of the prostate). The reference CT is registered onto the deformed CBCT and the deformed CT serves as the control for dose calculation accuracy. The planned treatment used for the evaluation of dose calculation is a 2-Gy fraction prescribed at the location of the reference prostate and assigned to 7 rectangular fields. Results: For a realistic 0.5-cm translation of the prostate, the relative dose discrepancy between the CBCT and the CT control scan at the prostate's centroid is 8.9 ± 0.8 % while dose discrepancy between the registered CT and the control scan lessens to −2.4 ± 0.8 %. For a 2-cm translation, clinical indices like the V90 and the D100 are more accurate by 0.7 ± 0.3 % and 8.0 ± 0.5 cGy respectively when using registered CT than when using CBCT for dose calculation. Conclusion: The results show that this strategy gives doses in agreement within a few percents with those from calculations on actual CT scans. In the future, various deformations of the phantom anatomy will allow a thorough characterization of the registration strategies needed for more complex anatomies.

60 APPLIED LIFE SCIENCES↗