Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high resolution spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

The Most Metal-poor Stars in the Inner Bulge

The bulge is the oldest component of the Milky Way. Since numerous simulations of Milky Way formation have predicted that the oldest stars at a given metallicity are found on tightly bound orbits, the Galaxy’s oldest stars are likely metal-poor stars in the inner bulge with small apocenters (i.e., R {sub apo} ≲ 4 kpc). In the past, stars with these properties have been impossible to find due to extreme reddening and extinction along the line of sight to the inner bulge. We have used the mid-infrared metal-poor star selection of Schlaufman & Casey (2014) on Spitzer/Galactic Legacy Infrared Mid-Plane Survey Extraordinaire data to overcome these problems and target candidate inner bulge metal-poor giants for moderate-resolution spectroscopy with Anglo-Australian Telescope/AAOmega. We used those data to select three confirmed metal-poor giants ([Fe/H] = −3.15, −2.56, −2.03) for follow-up high-resolution Magellan/Magellan Inamori Kyocera Echelle spectroscopy. A comprehensive orbit analysis using Gaia DR2 astrometry and our measured radial velocities confirms that these stars are tightly bound inner bulge stars. We determine the elemental abundances of each star and find high titanium and iron-peak abundances relative to iron in our most metal-poor star. We propose that the distinct abundance signature we detect is a product of nucleosynthesis in the Chandrasekhar-mass thermonuclear supernova of a CO white dwarf accreting from a helium star with a delay time of about 10 Myr. Even though chemical evolution is expected to occur quickly in the bulge, the intense star formation in the core of the nascent Milky Way was apparently able to produce at least one Chandrasekhar-mass thermonuclear supernova progenitor before chemical evolution advanced beyond [Fe/H]∼−3.

79 ASTRONOMY AND ASTROPHYSICS↗

Electronic and reactivity changes in epitaxially grown Ce 1-x Zr x O 2-δ (111) thin films

Ceria composite catalysts have long been used for ketonization reactions, which is a valuable chemistry for the upgrading of biomass-derived carboxylates. To better understand the interaction of zirconia with ceria in the context of ketonization, thin epitaxial films of ceria-zirconia mixed metal oxide Ce 1-x Zr x O 2-δ (x = 0-1) were grown on a Pt(111) substrate in ultrahigh vacuum conditions and studied with X-ray photoelectron spectroscopy (XPS). Core level and valence band XPS results suggest a strong interaction between ceria and zirconia cations, possibly due to increased filling of unoccupied 4f 0 orbitals of ceria from neighboring Zr cations in the lattice structure. This leads to a partial reduction of ceria from Ce 4+ to Ce 3+ , with Zr remaining predominantly in the 4+ oxidation state. Ketonization of acetic acid was studied using temperature programmed desorption (TPD) and high-resolution electron energy loss spectroscopy (HREELS). These results found ketonization over mixed Ce-Zr composite oxides exhibited lower activation energies than for pure CeO 2 and ZrO 2 , with Ce 0.38 Zr 0.62 O 2-δ exhibiting the highest yield of acetone among the studied surfaces. In conclusion, these results suggest the high activity of Ce-Zr catalysts appears to be a result of oxygen vacancy formation, stabilized by electron donation from Zr cations.

36 MATERIALS SCIENCE↗

Resonant inelastic X-ray scattering using a miniature dispersive Rowland refocusing spectrometer

X-ray absorption spectroscopy (XAS) beamlines worldwide are steadily increasing their emphasis on full photon-in/photon-out spectroscopies, such as resonant inelastic X-ray scattering (RIXS), resonant X-ray emission spectroscopy (RXES) and high energy resolution fluorescence detection XAS (HERFD-XAS). In such cases, each beamline must match the choice of emission spectrometer to the scientific mission of its users. Previous work has recently reported a miniature tender X-ray spectrometer using a dispersive Rowland refocusing (DRR) geometry that functions with high energy resolution even with a large X-ray spot size on the sample. This instrument has been used in the laboratory in multiple studies of non-resonant X-ray emission spectroscopy using a conventional X-ray tube, though only for preliminary measurements at a low-intensity microfocus synchrotron beamline. This paper reports an extensive study of the performance of a miniature DRR spectrometer at an unfocused wiggler beamline, where the incident monochromatic flux allows for resonant studies which are impossible in the laboratory. Here, the results support the broader use of the present design and also suggest that the DRR method with an unfocused beam could have important applications for materials with low radiation damage thresholds and that would not survive analysis on focused beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bragg crystal spectroscopy on the OSO 8 satellite

Results are reported for high-resolution OSO 8 Bragg-crystal spectroscopy of a variety of cosmic X-ray sources in the energy range from 2 to 10 keV. A continuous spectrum of Sco X-1 is examined, and results of a search for narrow line emission due to iron near 6.7 keV are presented for 32 galactic X-ray sources, including Sco X-1, Cyg X-3, and Cen X-3. It is noted that the strongest evidence for iron line emission has been obtained for Cyg X-3 and that evidence for an iron line feature has also been found in the spectrum of Cen X-3.

Long, K. S.↗

The joint NASA/Goddard-University of Maryland research program in charged particle and high energy photon detector technology

The first measurements of Fe charge states in two coronal hole-association high speed streams, using the sensor on ISEE-3, are presented. Eight event intervals from the January to June 1983 timeframe were chosen for the study of magnetotail dynamics and its relationship to substorm activity and the possible formation of plasmoids. Techniques are being explored for measurement of secondary electrons which are characteristically emitted when ions hit a target material. Efforts are continuing to understand kilometer wavelength shock associated radio events. An all-sky survey of fast X-ray transients of duration of 5 to 10,000 s was completed. Research using high resolution gamma-ray spectroscopy of celestial sources in the 20 keV to 20 MeV range to search for and study narrow lines in low-energy gamma-ray spectrum continues. Research in high energy radiation from pulsars is being conducted.

Source record↗

High-resolution pulse-counting array detectors for imaging and spectroscopy at ultraviolet wavelengths

The performance characteristics of multianode microchannel array (MAMA) detector systems which have formats as large as 256 x 1024 pixels and which have application to imaging and spectroscopy at UV wavelengths are evaluated. Sealed and open-structure MAMA detector tubes with opaque CsI photocathodes can determine the arrival time of the detected photon to an accuracy of 100 ns or better. Very large format MAMA detectors with CsI and Cs2Te photocathodes and active areas of 52 x 52 mm (2048 x 2048 pixels) will be used as the UV solar blind detectors for the NASA STIS.

Timothy, J. Gethyn↗

Polarization Switching on the Open Surfaces of the Wurtzite Ferroelectric Nitrides: Ferroelectric Subsystems and Electrochemical Reactivity

Binary ferroelectric nitrides are promising materials for information technologies and power electronics. However, polarization switching in these materials is highly unusual. From the structural perspective, polarization reversal is associated with the change of the effective polarity at the surfaces and interfaces from N‐to‐M terminated, suggesting strong coupling between ferroelectric and chemical phenomena. Phenomenologically, macroscopic studies demonstrate the presence of complex time dependent phenomena including wake‐up. Here, in this study, the polarization switching using the multidimensional high‐resolution piezoresponse force microscopy (PFM) and spectroscopy is explored, detecting both the evolution of induced ferroelectric domain, electromechanical response, and surface deformation during first‐order reversal curve measurements. The presence of two weakly coupled ferroelectric subsystems are demonstrated and the bias‐induced electrochemical reactivity. The observed behaviors are very similar to the recent studies of other wurtzite system but additionally include electrochemical reactivity, suggesting the universality of these behaviors for the wurtzite binary ferroelectrics. These studies suggest potential of high‐resolution multimodal PFM spectroscopies to resolve complex coupled polarization dynamics in materials. Furthermore, these PFM based studies are fully consistent with the recent electron microscopy observations of the shark‐teeth like ferroelectric domains in nitrides. Hence, it is believed that these studies establish the universal phenomenological picture of polarization switching in binary wurtzite.

36 MATERIALS SCIENCE↗

Chlorine and potassium enrichment in the Cassiopeia A supernova remnant

The elements in the Universe are synthesized primarily in stars and supernovae, where nuclear fusion favours the production of even-Z elements. In contrast, odd-Z elements are less abundant and their yields are highly dependent on detailed stellar physics, making theoretical predictions of their cosmic abundance uncertain. In particular, the origin of odd-Z elements such as phosphorus (P), chlorine (Cl) and potassium (K), which are important for planet formation and life, is poorly understood. While the abundances of these elements in Milky Way stars are close to solar values, supernova explosion models systematically underestimate their production by up to an order of magnitude, indicating that key mechanisms for odd-Z nucleosynthesis are currently missing from theoretical models. Here we report the observation of P, Cl and K in the Cassiopeia A supernova remnant using high-resolution X-ray spectroscopy with X-Ray Imaging and Spectroscopy Mission data, with the detection of K at above the 6σ level being the most significant finding. Supernova explosion models of normal massive stars cannot explain the element abundance pattern, especially the high abundances of Cl and K, while models that include stellar rotation, binary interactions or shell mergers agree closely with the observations. Our observations suggest that such stellar activity plays an important role in supplying these elements to the Universe.

Astronomy and AstroPhysics↗

An Overview of High-Resolution, Non-Dispersive, Imaging Spectrometers for High-Energy Photons

High-resolution x-ray spectroscopy has become a powerful tool for studying the evolving universe. The grating spectrometers on the XMM and Chandra satellites initiated a new era in x-ray astronomy. Despite their successes, there is still need for instrumentation that can provide higher spectral resolution with high throughput in the Fe-K band and for extended sources. What is needed is a non-dispersive imaging spectrometer - essentially a 14-bit x-ray color camera. And a requirement for a nondispersive spectrometer designed to provide eV-scale spectral resolution is a temperature below 0.1 K. The required spectral resolution and the constraints of thermodynamics and engineering dictate the temperature regime nearly independently of the details of the sensor or the read-out technology. Low-temperature spectrometers can be divided into two classes - - equilibrium and non-equilibrium. In the equilibrium devices, or calorimeters, the energy is deposited in an isolated thermal mass and the resulting increase in temperature is measured. In the non-equilibrium devices, the absorbed energy produces quantized excitations that are counted to determine the energy. The two approaches have different strong points, and within each class a variety of optimizations have been pursued. I will present the basic fundamentals of operation and the details of the most successful device designs to date. I will also discuss how the measurement priorities (resolution, energy band, count rate) influence the optimal choice of detector technology.

Kilbourne, Caroline↗

Ground Calibration of the Astro-H (Hitomi) Soft X-Ray Spectrometer

The Astro-H (Hitomi) Soft X-ray Spectrometer (SXS) was a pioneering imaging x-ray spectrometer with 5 eV energy resolution at 6 keV. The instrument used a microcalorimeter array at the focus of a high-throughput soft x-ray telescope to enable high-resolution non-dispersive spectroscopy in the soft x-ray waveband (0.3-12 keV). We present the suite of ground calibration measurements acquired from 2012-2015, including characterization of the detector system, anti-coincidence detector, optical blocking filters, and filter-wheel filters. The calibration of the 36-pixel silicon thermistor microcalorimeter array includes parameterizations of the energy gain scale and line spread function for each event grade over a range of instrument operating conditions, as well as quantum efficiency measurements. The x-ray transmission of the set of five Al/polyimide thin-film optical blocking filters mounted inside the SXS dewar has been modeled based on measurements at synchrotron beamlines, including with high spectral resolution at the C, N, O, and Al K-edges. In addition, we present the x-ray transmission of the dewar gate valve and of the filters mounted on the SXS filter wheel (external to the dewar), including beryllium, polyimide, and neutral density filters.

detectors↗

X-ray spectroscopic instrumentation for the 21st century

Several technologies being developed for high resolution X-ray spectroscopy are compared to determine the most suitable applications for each. Nondispersive cryogenic technology is considered by means of devices such as microcalorimeters and superconducting tunnel-junction detectors, and dispersive technologies are represented by crystal diffractors, transmission gratings and reflection gratings. Calorimeters and superconducting tunnel-junction conductors are found to be suitable for high energies while reflection gratings are more effective at lower energies. In general, however, the selected technology depends primarily on the particular implementation. Parameters such as launch capability, constraints, and scientific drivers are the guiding forces for selecting a particular device.

Kahn, Steven M.↗

A portable on-axis laser-heating system for near-90° X-ray spectroscopy: application to ferropericlase and iron silicide

A portable IR fiber laser-heating system, optimized for X-ray emission spectroscopy (XES) and nuclear inelastic scattering (NIS) spectroscopy with signal collection through the radial opening of diamond anvil cells near 90°with respect to the incident X-ray beam, is presented. The system offers double-sided on-axis heating by a single laser source and zero attenuation of incoming X-rays other than by the high-pressure environment. A description of the system, which has been tested for pressures above 100 GPa and temperatures up to 3000 K, is given. The XES spectra of laser-heated Mg 0.67 Fe 0.33 O demonstrate the potential to map the iron spin state in the pressure–temperature range of the Earth's lower mantle, and the NIS spectra of laser-heated FeSi give access to the sound velocity of this candidate of a phase inside the Earth's core. This portable system represents one of the few bridges across the gap between laser heating and high-resolution X-ray spectroscopies with signal collection near 90°.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving fission-product decay data for reactor applications: part I—decay heat

Effort has been expended to assess the relative merits of undertaking further decay-data measurements of the main fission-product contributors to the decay heat of neutron-irradiated fissionable fuel and related actinides by means of Total Absorption Gamma-ray Spectroscopy (TAGS - sometimes abbreviated to TAS) and Discrete Gamma-ray Spectroscopy (DGS). This review has been carried out following similar work performed under the auspices of OECD/WPEC-Subgroup 25 (2005–2007) and the International Atomic Energy Agency (2009, 2014), and various highly relevant TAGS measurements completed as a consequence of such assessments. Here, we present our recommendations for new decay-data evaluations, along with possible requirements for total absorption and discrete high-resolution gamma-ray spectroscopy studies that cover approximately 120 fission products and various isomeric states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

What Can Be Learned from X-Ray Spectroscopy Concerning Hot Gas in the Local Bubble and Charge Exchange Processes?

Both solar wind charge exchange emission and diffuse thermal emission from the Local Bubble are strongly dominated in the soft X-ray band by lines from highly ionized elements. While both processes share many of the same lines, the spectra should differ significantly due to the different production mechanisms, abundances, and ionization states. Despite their distinct spectral signatures, current and past observatories have lacked the spectral resolution to adequately distinguish between the two sources. High-resolution X-ray spectroscopy instrumentation proposed for future missions has the potential to answer fundamental questions such as whether there is any hot plasma in the Local Hot Bubble, and if so, what are the abundances of the emitting plasma and whether the plasma is in equilibrium. Such instrumentation will provide dynamic information about the solar wind including data on ion species which are currently difficult to track. It will also make possible remote sensing of the solar wind.

Snowden, S. L.↗

Laser techniques for spectroscopy of core-excited atomic levels

We discuss three techniques which allow the use of tunable lasers for high resolution and picosecond time scale spectroscopy of core-excited atomic levels. These are: anti-Stokes absorption spectroscopy, laser induced emission from metastable levels, and laser designation of selected core-excited levels.

Harris, S. E.↗

Functionalized Polymer Thin Films for Plutonium Capture and Isotopic Screening from Aqueous Sources

The rapid screening of plutonium from aqueous sources remains a critical challenge for nuclear nonproliferation efforts. The determination of trace-level Pu isotopes in water requires offsite sample preparation and analysis; therefore, new methods that combine plutonium purification, concentration, and isotopic screening in a fieldable detection system will provide an invaluable tool for nuclear safeguards. This contribution describes the development and characterization of thin polymer-ligand films for the isolation and concentration of waterborne Pu for direct spectroscopic analyses. Submicron thin films were prepared through spin coating onto Si wafers and consisted of combinations of polystyrene (PS) with dibenzoylmethane, thenoyltrifluoroacetone, and di(2-ethylhexyl)phosphoric acid (HDEHP). Pu uptake studies from solutions at pH from 2.3 to 6.3 indicated that only films containing HDEHP exhibited significant recovery of Pu. High alpha spectroscopy peak energy resolutions were achieved for PS-HDEHP films over a range of film thicknesses from 30 to 250 nm. Furthermore, a separate study was performed to evaluate uptake from a primarily Pu(V) solution where it was observed that doubling the HDEHP loading in the film increased uptake of Pu by an order of magnitude. X-ray photoelectron spectroscopy (XPS) analysis revealed that HDEHP was highly concentrated within the first few nanometers of the film at the higher loading. XPS analysis also revealed that, in the presence of water, HDEHP was stripped from the surface layer of the film at circumneutral pH. While significant losses of ligand were seen in all samples, higher loadings of HDEHP resulted in measurable amounts of ligand retained after a 12-h soak in water. Findings of this study are being used to guide the development of thin-film composite membrane-based detection methods for the rapid, fieldable analysis of Pu in water.

36 MATERIALS SCIENCE↗

Development of “GaSb-on-silicon” metamorphic substrates for optoelectronic device growth

The epitaxial development and characterization of metamorphic “GaSb-on-silicon” buffers as substrates for antimonide devices is presented. The approach involves the growth of a spontaneously and fully relaxed GaSb metamorphic buffer in a primary epitaxial reactor, and use of the resulting “GaSb-on-silicon” wafer to grow subsequent layers in a secondary epitaxial reactor. The buffer growth involves four steps—silicon substrate preparation for oxide removal, nucleation of AlSb on silicon, growth of the GaSb buffer, and finally capping of the buffer to prevent oxidation. This approach on miscut silicon substrates leads to a buffer with negligible antiphase domain density. The growth of this buffer is based on inducing interfacial misfit dislocations between an AlSb nucleation layer and the underlying silicon substrate, which results in a fully relaxed GaSb buffer. A 1 μm thick GaSb layer buffer grown on silicon has ~9.2 × 10 7 dislocations/cm 2 . The complete lack of strain in the epitaxial structure allows subsequent growths to be accurately lattice matched, thus making the approach ideal for use as a substrate. Here we characterize the GaSb-on-silicon wafer using high-resolution x-ray diffraction and transmission electron microscopy. The concept’s feasibility is demonstrated by growing interband cascade light emitting devices on the GaSb-on-silicon wafer. The performance of the resulting LEDs on silicon approaches that of counterparts grown lattice matched on GaSb.

36 MATERIALS SCIENCE↗