Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Geothermal play fairway analysis, part 1: Example from the Snake River Plain, Idaho

The Snake River Plain (SRP) volcanic province overlies the track of the Yellowstone hotspot, a thermal anomaly that extends deep into the mantle. Most of the area is underlain by a basaltic volcanic province that overlies a mid-crustal intrusive complex, which in turn provides the long-term heat flux needed to sustain geothermal systems. Previous studies have identified several known geothermal resource areas within the SRP. For the geothermal study presented herein, our goals were to: (1) adapt the methodology of Play Fairway Analysis (PFA) for geothermal exploration to create a formal basis for its application to geothermal systems, (2) assemble relevant data for the SRP from publicly available and private sources, and (3) build a geothermal PFA model for the SRP and identify the most promising plays, using GIS-based software tools that are standard in the petroleum industry. The study focused on identifying three critical resource parameters for exploitable hydrothermal systems in the SRP: heat source, reservoir and recharge permeability, and cap or seal. Data included in the compilation for heat source were heat flow, distribution and ages of volcanic vents, groundwater temperatures, thermal springs and wells, helium isotope anomalies, and reservoir temperatures estimated using geothermometry. Reservoir and recharge permeability was inferred from the analysis of stress orientations and magnitudes, post-Miocene faults, and subsurface structural lineaments based on magnetics and gravity data. Data for cap or seal included the distribution of impermeable lake sediments and clay-seal associated with hydrothermal alteration below the regional aquifer. These data were used to compile Common Risk Segment maps for heat, permeability, and seal, which were combined to create a Composite Common Risk Segment map for all southern Idaho that reflects the risk associated with geothermal resource exploration and identifies favorable resource tracks. Our regional assessment indicated that undiscovered geothermal resources may be located in several areas of the SRP. Two of these areas, the western SRP and Camas Prairie, were selected for more detailed assessment, during which heat, permeability, and seal were evaluated using newly collected field data and smaller grid parameters to refine the location of potential resources. These higher resolution assessments illustrate the flexibility of our approach over a range of scales.

54 ENVIRONMENTAL SCIENCES↗

Soft Matter Thermal and Mechnical Devices

The participant company, Treau, makes homes and buildings more comfortable with quiet, energy efficient, and easy to install heating and cooling systems. They entered the Cyclotron Road program with an idea for a heat exchanger and compressor and a general idea that the building heating and cooling sector was the best first target market. While at Cyclotron Road, they used the Cyclotron Road program staff and Berkeley Lab expertise to better understand the needs of the heating and cooling equipment market. This was critical to understand who the end customer was, and what features were needed in this market. They were then able to conduct product development with this target market/customer in mind. The Cyclotron Road program was also critical in building a manufacturing and scale-up plan that allowed the participant to build a credible growth and fundraising strategy. By the end of the program, the participant had a working prototype testing at Berkeley Lab’s HVAC testing facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heating Ventilation Air-Conditioning (HVAC) System Analysis and Optimization for Revit with the OpenStudio Analytical Framework (CRADA Final Report)

This project proposes to integrate the NREL-developed OpenStudio (OS) and its accompanying Analytical Framework (OSAF) into Autodesk’s (ADSK’s) market leading suite of building information modeling (BIM) tools. As a result, BIM users will gain access to advanced (but user-friendly) building energy modeling (BEM), calibration, and design optimization capabilities. Following integration, the BIM software will automatically generate a consistent OS-based BEM model, allowing users to develop projects in an integrated manner, moving back and forth between architectural and engineering perspectives without redundancy or data loss, saving time and effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

System with a direct contact desublimating heat exchanger and temperature regulation

A process to prevent fouling using a desublimating heat exchanger is disclosed. An outlet stream from the desublimating heat exchanger may be split into a plurality of parallel streams. The parallel streams may be sent through a plurality of discrete unit operations, and the unit operations may change the temperature of at least one of the parallel streams. Parallel streams of differing temperature may emerge from the unit operations. The parallel streams which are of a similar temperature may be mixed to form a warm stream and a cool stream. The warm stream and the cool stream may be sent to a mixing chamber. A mixed stream of substantially uniform temperature may emerge from the mixing chamber, and the mixed stream may be recycled back to the desublimating heat exchanger. The mixing chamber may be separate from the desublimating heat exchanger, or the parallel streams of differing temperature may be mixed in the desublimating heat exchanger.

42 ENGINEERING↗

Smart Monitoring and Diagnostic System (SMDS) for Packaged Air Conditioners and Heat Pumps for Small/Medium Commercial Buildings: Preparation for Commercialization: CRADA 478 [Abstract only]

This project will enable Pacific Northwest National Laboratory (PNNL) and industry partner, mCloud Technologies, to work collaboratively to ready the Smart Monitoring and Diagnostic System (SMDS) for commercial deployment and validate its performance under real-world conditions at field sites. This project will specifically focus on 1) implementing the SMDS algorithms in a scalable cloud-based software architecture, 2) designing new, innovative, complimentary commercial services based on the SMDS, 3) enhancing the SMDS energy and cost impact algorithms to reduce uncertainty in estimates, 4) determining the lower limits on SMDS performance degradation detection, 5) validating algorithm performance and default values of adjustable thresholds with existing data from controlled physical testing and from customer packaged air conditioners and heat pumps (commonly referred to as rooftop units or RTUs), 6) field testing to validate the system on multiple customer buildings in diverse environments, and 7) expanding field deployment to a larger set of mCloud’s customer buildings. Project results by validating, enhancing, and quantifying the performance of the SMDS will position mCloud, and potential future licensees, to implement the SMDS in commercial offerings that encourage and enable use of condition-based and predictive maintenance, leading to significant reductions in energy use and greenhouse gas emissions associated with space conditioning by RTUs. Furthermore, these enhancements will increase the value of the SMDS for users and increase the potential market for its use and impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Membrane-based Ionic Liquid Absorption System for Ultra-Efficient Dehumidification and Heating

The project team – comprising the University of Florida (UF), GTI Energy, and Modine Manufacturing – sought to develop a highly efficient heat-powered absorption cycle with combined dehumidification and heat pumping. This DOE-supported project advanced the technology from a TRL of 3 to 6, culminating in the development of a 1,000 CFM system. Key innovations implemented in the system addressed the low efficiency, size, cost, and reliability challenges of conventional absorption cycles. Specifically, the system was enabled by: (1) a semi-open cycle that allowed simultaneous dehumidification and heat recovery, (2) non-crystallizing ionic liquids (ILs) that enabled “double-effect” operation at elevated temperatures without the need for costly control equipment, (3) a compact membrane-based absorber that confined the IL and directly cooled it to achieve low dew points, and (4) a novel, highly integrated desorber–condenser assembly that reduced size, weight, and cost. The technology was developed with commercial HVAC applications in mind, particularly for separate sensible and latent cooling (SSLC), an innovation aimed at achieving independent and more efficient humidity control.

42 ENGINEERING↗

Flow maldistribution in plate heat exchangers – Impact, analysis, and solutions

Plate heat exchangers are commonly used in various industrial applications, such as refrigeration, air conditioning, heat pumps, powerplants, and chemical industries. Plate heat exchangers are well known for their superior heat transfer performance, compactness, and low refrigerant charge. Despite offering several advantages, they suffer from flow maldistribution issues. The flow maldistribution can deteriorate both the heat transfer and pressure drop performance, ultimately resulting in a lower system efficiency where plate heat exchangers are deployed. The flow maldistribution issues become more pronounced when the heat exchanger size is relatively large and the number of plates is higher, limiting the deployment of plate heat exchangers in larger industrial systems. Consequently, analyzing and understanding the flow maldistribution behavior in plate heat exchangers and finding ways to mitigate flow maldistribution related issues become essential topics of interest. Further, this review aims to address the effect of flow maldistribution on plate heat exchanger characteristics. First, the experimental and numerical works on flow maldistribution under single-phase and two-phase conditions are detailed. Subsequently, the end-channel and end-plate effects are discussed. Then, the methods to mitigate flow maldistribution in plate heat exchangers are outlined. Finally, based on a thorough literature survey and industrial requirements, future research directions are recommended.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of Electrochemical Water Filtration System on Open Loop Cooling Towers at Automotive Plants

Open loop cooling towers play a pivotal role in rejecting heat for chilled water systems serving industrial processes, heating, ventilation, and air conditioning loads. Exposure to outside conditions can present certain operating challenges to system performance including scaling, corrosion, and biological growth. These issues are mitigated through the use of effective cooling tower water filtration and treatment systems to reduce contaminants—along with other total suspended solids (TSS) and total dissolved solids (TDS)—in the system. The U.S. Department of Energy’s Industrial Efficiency and Decarbonization Office is interested in an electrochemical-based filtration system with the ability to remove TSS particulate down to 1 micron. The removal of finer particulates reduces the need for blowdown and, in turn, makeup water use and chemical treatment in the cooling tower. Additionally, the removal process can reduce fouling at the condensers, resulting in better heat exchange and energy savings. Two Industrial Technology Validation program projects validated the electrochemical water filtration system at the Toyota Motor Manufacturing, Mississippi plant in Blue Springs, Mississippi, and the Nissan Canton Vehicle Assembly Plant in Canton, Mississippi. Researchers found that installation of both systems resulted in water and chemical treatment savings with minimal impact on energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Consumer Guide to Residential Renewable Energy

Learn how installing residential renewable energy systems, such as geothermal heat pumps and wind or solar energy systems, can save energy, lower utility bills, and earn homeowners money. This fact sheet from Energy Saver includes information on how to start planning to install renewable energy systems at home.

residential renewable energy, geothermal heat pump↗

Perform Life Cycle Energy and GHG Emission Analysis, Select Candidate Refrigerant(s), Developing Heat Pump by Using Low-GWP Refrigerants and 5 mm Diameter Tubes

Reducing environmental impacts from the energy conversion systems has been an important research topic due to recent severe global climate changes. In residential buildings, the space heating and cooling are main energy consumers, which are relying on vapor compression based heat pumps. To mitigate the environmental impacts of residential systems, the heat pumps using low-GWP refrigerants and 5mm-tube heat exchangers are proposed to replace the conventional 9 mm or 7 mm tube heat exchangers. This research uses a simulation-based design method to optimize the refrigerant circuitries of a 5-ton low-GWP refrigerant heat pumps whose indoor and outdoor heat exchangers adopt 5 mm tubes. Heat pump systems using four commercially available low-GWP refrigerants (R454A, R454C, ARM20A and ARM20B) are optimized and compared with the baseline R410A system. The results indicate that directly replacing 9 mm tubes into 5mm tubes in the baseline systems induces heat pump performance degradation; by optimizing the 5 mm tube heat pumps with added tube rows, the system refrigerant charge is reduced up to 33% compared with the baseline; the optimized low-GWP 5 mm tube heat pumps offer the same or higher performance under both cooling and heating mode; that under cooling mode, the EER improvement is up to 10.7% and under heating mode the COP improvement is up to 3.4%; and a smart flow control device to maintain counter-flow circuitry pattern on both operating modes can improve the heating performance of 5 mm tube optimized system by up to 3.0%. In an effort to better understand the environmental impacts of these systems, life cycle climate performance (LCCP) evaluation method is used to assess the baseline and optimized systems. LCCP considers the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. Our analyses indicate that the optimized systems using 5mm tubes and low-GWP refrigerants can reduce life-cycle CO 2 emission significantly. And improving system efficiency is the most effective way to reduce the emission of low-GWP refrigerant systems. This report shows that using 5 mm diameter tubes in heat exchangers is a feasible approach to develop heat pumps with low-GWP refrigerants. Using the proposed design approach can yield higher system efficiency with lower environmental impact.

42 ENGINEERING↗

Heating performance of an air source heat pump with a portable thermoelectric subcooler

This study investigates the heating performance of an integrated air-source heat pump (ASHP) with a thermoelectric subcooler (TES) module, revealing significant performance enhancements, particularly in colder temperatures. Results show that adding the portable TES boosts the ASHP's heating capacity, making it feasible for residential applications. The coefficient of performance (COP) for the TE system, which is influenced by condensing temperatures and ambient conditions, ranges from 1.51 to 2.07. If condensing temperatures are consistently maintained above 35 °C, a TE COP of approximately 2.07 is achievable, supporting system downsizing and reducing supplemental heating. When coupled with an oversized indoor coil, the TES-ASHP system delivers comparable heating to a baseline unit while achieving a 10 % higher COP. Capacity increases by 8.7 %–24 % with TES in colder conditions, though COP declines by 9 %–18 %, diminishing as temperatures drop. Compared to systems with supplemental heating, this setup achieves a COP 10 %–17 % higher. Future work will involve extended field testing in various climates, exploration of advanced materials for thermal efficiency, and assessment of alternative refrigerants to improve performance and sustainability. This integrated ASHP-TES system holds promise for increased efficiency and reduced environmental impact in cold climates.

Air source heat pump↗

Hybrid solar system

A hybrid solar system including a hybrid solar collector using non-imaging optics and photovoltaic components and a heat transfer and storage system in thermal communication with the hybrid solar collector, the heat transfer and storage system using particle laden gas as thermal media to simultaneously generate and store electricity and high temperature dispatchable heat.

14 SOLAR ENERGY↗

Latent heat thermal energy storage performance maps enabling fast & accurate building energy simulations

Thermal energy storage (TES) using phase change materials (PCMs) has gained attention as an effective approach to manage energy demand fluctuations and shift peak building loads. PCM embedded heat exchangers (PCM-HXs) offer high energy storage density and low temperature variation during phase change, being suitable for load-shifting applications. However, this component is typically evaluated using computationally expensive methods, which present significant challenges when the ultimate goal is to assess the performance of PCM-HX integrated thermal energy storage systems in the full building context. In this paper, we present a methodology to generate highly accurate and computationally efficient PCM-HX performance maps which can be easily integrated into building energy simulation tools to analyze the feasibility of space conditioning systems with latent heat PCM-based TES. The performance maps are generated using a computationally efficient PCM-HX simulation tool based on a Generalized Resistance-Capacitance Model (GRCM) which can simulate arbitrary PCM-HXs with high accuracy and significantly less computational effort compared to full CFD simulations. The methodology was verified for a case study considering a 5-ton (~17.5 kW) air-to-water heat pump-thermal energy storage system (HP-TES), which was co-simulated in Modelica for a DOE prototype small-office building in Vienna, Austria, using Spawn of EnergyPlus™. The TES performance maps provided accurate predictions of PCM-HX behavior when used as Modelica component, with deviations within 2-4% while also achieving at least 103 computational time reduction. Leveraging this faster prediction capability, four PCMs with different melting temperatures for cooling (12°C, 16°C) and heating (31°C, 36°C) were assessed to investigate their impact on system performance. This work highlights the importance of robust PCM-HX models for efficient and high-fidelity building-level simulations, presenting new opportunities for advanced control strategy development and parametric analysis of TES configurations in a computationally efficient manner

Modelica Building Simulations↗

Multi-physics Modeling of Radiative Heat Transfer and Fluid Flow for the Reactor Cavity Cooling System

High-temperature gas-cooled reactors (HTGRs) are notable for their high thermal efficiency and potential for combined heat and power applications. These reactors are particularly appealing due to their advanced passive safety features. HTGRs utilize passive safety systems that function without requiring active components like pumps or compressors during emergencies. These reactor designs depend on a Reactor Cavity Cooling System (RCCS) to manage decay heat removal from the reactor pressure vessel (RPV) during accident conditions. The RCCS consists of vertical rectangular channels known as "risers" or riser ducts positioned around the RPV. These risers receive heat from the RPV through both convective and radiative heat transfer mechanisms. Understanding the interplay of multiple physical phenomena, such as fluid dynamics, heat transfer, and neutron interactions, is essential for the effective design and operation of nuclear reactors, particularly for systems like the RCCS. Multi-physics simulations provide a comprehensive approach to studying these interactions, offering detailed insights and enhancing accuracy. They are especially important in RCCS designs, where the interaction between radiative and convective heat transfer can significantly impact system performance. By leveraging multi-physics simulations, complex reactor behaviors can be modeled without compromising the fidelity of the underlying physical processes. This work aims to establish a robust methodology for coupling multiple physical processes in an air-cooled RCCS. By focusing on validating this multi-physics approach, the study involves designing test cases that simulate various conditions to verify the numerical models employed. The outcomes of this research will provide critical insights for accurately modeling and optimizing complex nuclear systems like the RCCS.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Serpentine Heat Exchangers to Minimize Number of Joints and Leakage in HVAC&R Systems

Refrigerant leakage has a significant impact on heating, ventilation, air conditioning and refrigeration (HVAC&R) industries in terms of both greenhouse gas (GHG) emissions and lost efficiency of the systems themselves. One of the major causes of refrigerant leakage is braze joints within a vapor compression system. The brazing process is often inconsistent and almost always imperfect. As a result, braze joints are left vulnerable to leaks and can be weaker than non-brazed tubing. Conventional tube-fin heat exchangers are manufactured using one brazed joint per tube. An alternative to the conventional approach is the use of a single continuous serpentine tube. An Advanced Serpentine Heat Exchanger was developed to provide a heat transfer solution that meets or exceeds performance while also significantly reducing the number of joints and, consequently, the potential for refrigerant leakage. The developed serpentine heat exchanger not only delivers on performance, but is also cost competitive with conventional heat exchangers on the market.

30 DIRECT ENERGY CONVERSION↗