Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Cold Climate Heat Pumps Using Tandem Compressors

In cold climate zones, e.g. ASHRAE climate regions IV and V, conventional electric air-source heat pumps (ASHP) do not work well, due to high compressor discharge temperatures, large pressure ratios and inadequate heating capacities at low ambient temperatures. Consequently, significant use of auxiliary strip heating is required to meet the building heating load. We introduce innovative ASHP technologies as part of continuing efforts to eliminate auxiliary strip heat use and maximize heating COP with acceptable cost-effectiveness and reliability. These innovative ASHP were developed using tandem compressors, which are capable of augmenting heating capacity at low temperatures and maintain superior part-load operation efficiency at moderate temperatures. Two options of tandem compressors were studied; the first employs two identical, single-speed compressors, and the second employs two identical, vapor-injection compressors. The investigations were based on system modeling and laboratory evaluation. Both designs have successfully met the performance criteria. Laboratory evaluation showed that the tandem, single-speed compressor ASHP system is able to achieve heating COP = 4.2 at 47 F (8.3 C), COP = 2.9 at 17 F (-8.3 C), and 76% rated capacity and COP = 1.9 at -13 F (-25 C). This yields a HSPF = 11.0 (per AHRI 210/240). The tandem, vapor-injection ASHP is able to reach heating COP = 4.4 at 47 F, COP = 3.1 at 17 F, and 88% rated capacity and COP = 2.0 at -13 F. This yields a HSPF = 12.0. The system modeling and further laboratory evaluation are presented in the paper.

Shen, Bo↗

A Green’s Function Sensor Fusion Approach for Evaluating Spacecraft Entry Heating From on-Board Thermal Instrumentation

During atmospheric entry, distributed thermal measurements are critical to enable the evaluation of heat loads on spacecraft thermal protection systems (TPS). In recent space exploration missions, Schmidt-Boelter-type heat flux gauges have been integrated into the TPS alongside conventional temperature measurement instrumentation to measure total (convective and radiative) and radiative heat transfer rates1,2. While direct heat flux sensors (HFS) are able to provide valuable information detailing the thermal loads experienced by spacecraft, the interpretation of these measurements in unsteady, convective environments requires a correction factor to account for local heating augmentations at the cold wall HFS surface2,3. Current efforts to estimate cold wall correction factors, and thus recover the hot wall TPS heat flux, rely on time-marching computational fluid dynamics (CFD) simulations2. Simulation-based methods are susceptible to large uncertainties, however, as they require estimations of vehicle trajectory, gas kinetics, wall catalysis models, and other flight conditions as input parameters2,4. Furthermore, CFD simulations are computationally expensive and cannot efficiently survey all possible entry scenarios, exacerbating the uncertainty of reconstructed hot wall heat flux values. These drawbacks motivate the development of alternative hot wall heat flux reconstruction methods that are not reliant on CFD-based correction factors.

Kenneth McAfee↗

A Green’s Function Sensor Fusion Approach for Evaluating Spacecraft Entry Heating From on-Board Thermal Instrumentation

During atmospheric entry, distributed thermal measurements are critical to enable the evaluation of heat loads on spacecraft thermal protection systems (TPS). In recent space exploration missions, Schmidt-Boelter-type heat flux gauges have been integrated into the TPS alongside conventional temperature measurement instrumentation to measure total (convective and radiative) and radiative heat transfer rates1,2. While direct heat flux sensors (HFS) are able to provide valuable information detailing the thermal loads experienced by spacecraft, the interpretation of these measurements in unsteady, convective environments requires a correction factor to account for local heating augmentations at the cold wall HFS surface2,3. Current efforts to estimate cold wall correction factors, and thus recover the hot wall TPS heat flux, rely on time-marching computational fluid dynamics (CFD) simulations2. Simulation-based methods are susceptible to large uncertainties, however, as they require estimations of vehicle trajectory, gas kinetics, wall catalysis models, and other flight conditions as input parameters2,4. Furthermore, CFD simulations are computationally expensive and cannot efficiently survey all possible entry scenarios, exacerbating the uncertainty of reconstructed hot wall heat flux values. These drawbacks motivate the development of alternative hot wall heat flux reconstruction methods that are not reliant on CFD-based correction factors.

Kenneth McAfee↗

A Green’s Function Sensor Fusion Approach for Evaluating Spacecraft Entry Heating From on-Board Thermal Instrumentation

During atmospheric entry, distributed thermal measurements are critical to enable the evaluation of heat loads on spacecraft thermal protection systems (TPS). In recent space exploration missions, Schmidt-Boelter-type heat flux gauges have been integrated into the TPS alongside conventional temperature measurement instrumentation to measure total (convective and radiative) and radiative heat transfer rates1,2. While direct heat flux sensors (HFS) are able to provide valuable information detailing the thermal loads experienced by spacecraft, the interpretation of these measurements in unsteady, convective environments requires a correction factor to account for local heating augmentations at the cold wall HFS surface2,3. Current efforts to estimate cold wall correction factors, and thus recover the hot wall TPS heat flux, rely on time-marching computational fluid dynamics (CFD) simulations2. Simulation-based methods are susceptible to large uncertainties, however, as they require estimations of vehicle trajectory, gas kinetics, wall catalysis models, and other flight conditions as input parameters2,4. Furthermore, CFD simulations are computationally expensive and cannot efficiently survey all possible entry scenarios, exacerbating the uncertainty of reconstructed hot wall heat flux values. These drawbacks motivate the development of alternative hot wall heat flux reconstruction methods that are not reliant on CFD-based correction factors.

Kenneth McAfee↗

RDI's Wisdom Way Solar Village Final Report: Includes Utility Bill Analysis of Occupied Homes

In 2010, Rural Development, Inc. (RDI) completed construction of Wisdom Way Solar Village (WWSV), a community of ten duplexes (20 homes) in Greenfield, MA. RDI was committed to very low energy use from the beginning of the design process throughout construction. Key features include: 1. Careful site plan so that all homes have solar access (for active and passive); 2. Cellulose insulation providing R-40 walls, R-50 ceiling, and R-40 floors; 3. Triple-pane windows; 4. Airtight construction (~0.1 CFM 50 /ft 2 enclosure area); 5. Solar water heating systems with tankless, gas, auxiliary heaters; 6. PV systems (2.8 or 3.4kW STC ); 7. 2-4 bedrooms, 1,100-1,700 ft 2 . The design heating loads in the homes were so small that each home is heated with a single, sealed-combustion, natural gas room heater. The cost savings from the simple HVAC systems made possible the tremendous investments in the homes' envelopes. The Consortium for Advanced Residential Buildings (CARB) monitored temperatures and comfort in several homes during the winter of 2009-2010. In the Spring of 2011, CARB obtained utility bill information from 13 occupied homes. Because of efficient lights, appliances, and conscientious home occupants, the energy generated by the solar electric systems exceeded the electric energy used in most homes. Most homes, in fact, had a net credit from the electric utility over the course of a year. On the natural gas side, total gas costs averaged $|$$377 per year (for heating, water heating, cooking, and clothes drying). Total energy costs were even less - $\$$337 per year, including all utility fees. The highest annual energy bill for any home evaluated was $\$$458; the lowest was $\$$171.

14 SOLAR ENERGY↗

Analysis of aerothermal loads on spherical dome protuberances

Hypersonic flow over spherical dome protuberances was investigated to determine increased pressure and heating loads to the surface. The configuration was mathematically modeled in a time-dependant three-dimensional analysis of the conservation of mass, momentum (Navier-Stokes), and energy equations. A boundary mapping techique was used to obtain a rectangular parallelepiped computational domain, and a MacCormack explicit time-split predictor-corrector finite difference algorithm was used to obtain solutions. Results show local pressures and heating rates for domes one-half, one, and two boundary layer thicknesses high were increased by factors on the order of 1.4, 2, and 6, respectively. However, because lee-side pressure and thermal loads were reduced the two lower height domes did not experience any net increase in total loads. The total loads on the higher dome were increased by twenty-five percent. Flow over the lower dome was everywhere attached while flow over the intermediate dome had small windward and leeside separations. The higher dome had an unsteady windward separation region and a large leeside separation region. Trailing vortices form on all domes with intensity increasing with dome height. Discussions of applying the results to a thermally bowed thermal protection system are presented.

Olsen, G. C.↗

Perspective of Dry Interim Storage of spent nuclear fuel (SNF) in Germany - 16504

According to article 6 of the German Atomic Energy Act, storage of nuclear fuel requires a license granted by the competent authority in this field, which is the Federal Office of Radiation Protection (BfS). In 1995 a license to store spent nuclear fuel (SNF) and vitrified high level waste (HAW) for the interim storage facility in Gorleben was granted. Dry Interim storage at the NPP sites in its current form started in 2002 in the interim storage facility next to the NPP Lingen. Since this time each NPP erected its own storage facility and three central storage facilities have been built. All of these facilities use dry storage in metallic dual purpose casks (DPCs). The actual storage licenses for SNF and the HAW (which is stored in Gorleben and Rubenow) are limited to 40 years after closing the transport and storage cask. The first license to expire will be the storage license for the interim storage facility in Gorleben in the year 2035. During the last two years in Germany preparatory consultations to restart the process towards finding a repository took place, organised by a commission. This commission consists out of members of the scientific community, religious parties, social communities and environmental organizations as well as members of federal states governments and members of the German parliament (Bundestag). Recently the commission decided to extend its working period until summer 2016. Taking this background into account the BfS plans to intensify its research into extended interim storage with respect to potential material degradation leading to interference with safety functions (e.g. neutron shielding material). This includes topics like ageing of gasket materials which are already studied in ongoing experiments (e.g. at the Federal Institute for Materials Research and Testing) as well as studies of long term relaxation processes. Because of the need for transportation towards a repository another important field is the behaviour of the inventory under mechanical loads. For SNF, first calculations showed that because of the lower decay heat load after 60 years due to hydride reorientation the cladding might become much less ductile. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A turnkey gaseous helium-cooled superconducting CORC ® dc power cable with integrated current leads

Abstract High-temperature superconducting (HTS) direct current (dc) power cable systems, capable of delivering power exceeding 10 MW while being cooled with cryogenic helium gas, have been developed for applications on naval electric ships, electric aircraft and in data centers. Current injection from room temperature into the superconducting power cable causes by far the greatest heat load to the cryogenic system. Efficient current leads with integrated helium gas heat exchangers were developed to inject a current exceeding 1 kA from room temperature into a superconducting Conductor on Round Core (CORC ® ) power cable, without the need for liquid nitrogen pre-cooling. A 2 m long single-pole CORC ® power cable system that included current leads was cooled using a Stirling cryocooler with a closed-loop helium gas circulation system. The turnkey power cable system allowed cool down from room temperature to its operating temperature of 60 K–70 K within 5 h, after which continuous operation at 1.2 kA was demonstrated. The successful development and demonstration of a CORC ® power cable with current leads containing integrated helium gas heat exchangers enables widespread implementation of HTS MW-class, high current density superconducting dc power cables in many applications with constrained space that require a power dense solution.

Physics↗

A semi-automated algorithm for designing stellarator divertor and limiter plates and application to HSX

We present a semi-automated algorithm for designing three-dimensional divertor or limiter plates targeting low heat loads. The algorithm designs the plates in two stages: firstly, the parallel heat flux distribution is caught on vertically-inclined plates at one or several toroidal locations. Secondly, the power per unit area is reduced by stretching, tilting and bending the plates toroidally. Heat transport is modelled using the EMC3-Lite code, which uses an anisotropic diffusion model. We apply this scheme to HSX, a medium-sized stellarator located at the University of Wisconsin–Madison. Starting from the current machine with an extended vessel wall, we construct plates which are able to effectively catch and spread the heat for three different magnetic configurations. The scheme has a computational cost in the order of tens of CPU-minutes, making it a powerful tool for semi-automated plasma-facing component design in three-dimensional environments.

anisotropic diffusion↗

Thermal Analysis of a Superconducting Undulator Cryostat for the APS Upgrade

The Advanced Photon Source Upgrade includes four 4.8-m-long superconducting undulator (SCU) cryostats, each containing two planar undulator NbTi magnets up to 1.9 m long. The cooling is provided by six cryocoolers arranged in three thermal circuits. The magnets are indirectly cooled with LHe penetrating through channels in the magnet cores. This 4 K circuit, which also includes a LHe tank, is cooled by five 4 K cryocooler 2nd stages. A beam vacuum, which is thermally isolated from the magnets, is cooled by one 10 K cryocooler 2nd stage. A thermal shield and warm parts of current leads are cooled by the 1st stages of all six cryocoolers. This paper presents an ANSYS-based thermal analysis of the new SCU cryostat including all thermal circuits. The benchmarked thermal conductance between the cryocooler cold heads and the LHe tank are used in the calculations as well as the measured cryocooler load lines. The model predicts temperatures in the system, total 4 K heat loads, and excess cooling power for various operational modes of the undulator.

Shiroyanagi, Y.↗

Solar-heating and cooling system design package

Package of information includes design data, performance specifications, drawings, hazard analysis, and spare parts list for commercially produced system installed in single-family dwelling in Akron, Ohio. System uses air flat-plate collectors, 12000 kg rock storage and backup heat pump. Solar portion requires 0.7 kW, and provides 35% of average total heating load including hot water. Information aids persons considering installing solar home-heating systems.

Source record↗

Development of advanced high-temperature heat flux sensors. Phase 2: Verification testing

A two-phase program is conducted to develop heat flux sensors capable of making heat flux measurements throughout the hot section of gas turbine engines. In Phase 1, three types of heat flux sensors are selected; embedded thermocouple, laminated, and Gardon gauge sensors. A demonstration of the ability of these sensors to operate in an actual engine environment is reported. A segmented liner of each of two combustors being used in the Broad Specification Fuels Combustor program is instrumented with the three types of heat flux sensors then tested in a high pressure combustor rig. Radiometer probes are also used to measure the radiant heat loads to more fully characterize the combustor environment. Test results show the heat flux sensors to be in good agreement with radiometer probes and the predicted data trends. In general, heat flux sensors have strong potential for use in combustor development programs.

Atkinson, W. H.↗

Effects of specularly reflected radiation on spacecraft temperatures and thermal gradients

This paper describes the effect that specularly reflected solar energy has upon the heating load imposed upon orbiting spacecraft. Because this reflection may increase the total heating by factors of two or three, it is important that it can be computed accurately. An efficient method for treating multiple reflections is given and demonstrated by computing the temperatures and thermal gradients in a reflecting spherical radiator.

Emery, A. F.↗

Development of a high-performance cryogenic radiator with V-groove radiation shields

A feasibility demonstration model of a new-technology, high-performance, cryogenic radiative cooler has been successfully tested in a helium-cooled vacuum chamber. Thermal isolation of the radiator cold stage from the warm spacecraft and instrument is achieved by a novel arrangement of lightweight radiation shields which form large V-groove cavities, and by the use of low-conductance structural supports. The vacuum chamber experiments demonstrate the thermal isolation capability of the radiator design. Analytical model predictions are all within 1 K of the measured test temperatures. Utilization of this design enables reasonably sized radiative coolers (less than 0.3 sq m) to achieve operating temperatures below 60 K at earth, Mars, and beyond for useful cooling loads below 75 mW. The design can be scaled to accommodate larger heat loads. The reduction in operating temperature of over 15 K relative to any radiative cooler flown in the past will allow the V-groove isolation radiator to meet the challenging instrument cooling requirements of many future space missions.

Bard, Steven↗

Ames Research Center Mars/Pathfinder Heat Shield Design Verification ARC-JET Test

Design verification tests were performed on samples representing the aerobrake of the Mars/Pathfinder vehicle. The test specimens consisted of the SLA-561V ablator bonded to the honeycomb structure. The primary objective was to evaluate the ablation materials performance and to measure temperatures within the ablator, at the structural bondline and at the back sheet of the honeycomb structure. Other objectives were to evaluate the effect of ablative repair plug material treatment and voids in the heat shield. A total of 29 models were provided for testing in the Ames 60MW arc-jet facility. Of these, 23 models were flat-faced and six remaining models were curved edge ones, intended to simulate the conditions on the curved rim of the forebody where the maximum shear occurred. Eight sets of test conditions were used. The stagnation point heating rates varied from 47 to 240 W/cm2 and the stagnation pressures from 0.15 to 0.27 atm. (The maximum flight values are 132 W/cm2 and 0.25 atm) The majority of these runs were made at a nominal stagnation pressure of 0.25 atm. Two higher pressure runs were made to check the current (denser) ablation material for spallation, or other forms of thermal stress failure. Over 60% of the flatfaced models yielded good thermocouple data and all produced useful surface recession information. Of the five curved-edge models that were tested, only one gave good data; the remaining ones experienced model-holder failure. The test results can be summarized by noting that no failure of the ablative material was observed on any model. Also, the bondline temperature design limit of 250 C was never reached within an equivalent flight time despite a stagnation point heat load that exceeded the maximum flight value by up to 130%. At heating rates of over 200W/cm2 and stagnation pressures of 0.25 atm, or greater, the average surface recessions exceeded 0.5 cm on some models. The surface roughness increased dramatically at pressures above 0.25 atm and was four times greater at 0.27 atm than at 0.25 atm. Procured repair plug material performed much better than room-temperature cured plugs, as observed in the previous tests. Voids in the ablator did not increase local temperatures and gaps did not grow during testing.

Tran, Huy K.↗

Computational Model of Heat Transfer on the ISS

SCRAM Lite (SCRAM signifies Station Compact Radiator Analysis Model) is a computer program for analyzing convective and radiative heat-transfer and heat-rejection performance of coolant loops and radiators, respectively, in the active thermal-control systems of the International Space Station (ISS). SCRAM Lite is a derivative of prior versions of SCRAM but is more robust. SCRAM Lite computes thermal operating characteristics of active heat-transport and heat-rejection subsystems for the major ISS configurations from Flight 5A through completion of assembly. The program performs integrated analysis of both internal and external coolant loops of the various ISS modules and of an external active thermal control system, which includes radiators and the coolant loops that transfer heat to the radiators. The SCRAM Lite run time is of the order of one minute per day of mission time. The overall objective of the SCRAM Lite simulation is to process input profiles of equipment-rack, crew-metabolic, and other heat loads to determine flow rates, coolant supply temperatures, and available radiator heat-rejection capabilities. Analyses are performed for timelines of activities, orbital parameters, and attitudes for mission times ranging from a few hours to several months.

Torian, John G.↗

Optimization of a Hot Structure Aeroshell and Nose Cap for Mars Atmospheric Entry

The National Aeronautics and Space Administration (NASA) is preparing to send humans beyond Low Earth Orbit and eventually to the surface of Mars. As part of the Evolvable Mars Campaign, different vehicle configurations are being designed and considered for delivering large payloads to the surface of Mars. Weight and packing volume are driving factors in the vehicle design, and the thermal protection system (TPS) for planetary entry is a technology area which can offer potential weight and volume savings. The feasibility and potential benefits of a ceramic matrix composite hot structure concept for different vehicle configurations are explored in this paper, including the nose cap for a Hypersonic Inflatable Aerodynamic Decelerator (HIAD) and an aeroshell for a mid lift-to-drag (Mid L/D) concept. The TPS of a planetary entry vehicle is a critical component required to survive the severe aerodynamic heating environment during atmospheric en- try. The current state-of-the-art is an ablative material to protect the vehicle from the heat load. The ablator is bonded to an underlying structure, which carries the mechanical loads associated with entry. The alternative hot structure design utilizes an advanced carbon-carbon material system on the outer surface of the vehicle, which is exposed to the severe heating and acts as a load carrying structure. The preliminary design using the hot structure concept and the ablative concept is determined for the spherical nose cap of the HIAD entry vehicle and the aeroshell of the Mid L/D entry vehicle. The results of the study indicate that the use of hot structures for both vehicle concepts leads to a feasible design with potential weight and volume savings benefits over current state-of-the-art TPS technology that could enable future missions.

Langston, Sarah L.↗

Analysis of aerothermal loads on spherical dome protuberances

Hypersonic flow over spherical dome protuberances was investigated to determine increased pressure and heating loads to the surface. The configuration was mathematically modeled in a time-dependent three-dimensional analysis of the conservation of mass, momentum (Navier-Stokes), and energy equations. A boundary mapping technique was used to obtain a rectangular parallelepiped computational domain, a MacCormack explicit time-split predictor-corrector finite difference algorithm was used to obtain solutions. Results show local pressures and heating rates for domes one-half, one, and two boundary layer thicknesses high were increased by factors on the order of 1.4, 2, and 6, respectively. Flow over the lower dome was everywhere attached while flow over the intermediate dome had small windward and leeside separations. The higher dome had an unsteady windward separation region and a large leeside separation region. Trailing vortices form on all domes with intensity increasing with dome height. Discussion of applying the results to a thermally bowed thermal protection system are presented.

Olsen, G. C.↗