Fitness for Service Assessment of a Corroded Heat Exchanger

Fermilab s Main Injector Accelerator has used shell & tube heat exchangers to cool various beamline components since its construction in the late 1990s. Many of the heat exchangers still around today are original to the machine. Untreated pond water has been used to exchange heat with the Low Conductivity Water. Throughout the lifetime of Fermilab s heat exchangers, they have undergone significant material degradation in the carbon steel end channels due to corrosion. Wall thickness measurements (per API 510) of each heat exchanger were used to generate a 3D model of the corroded surfaces. In order to continue their safe and reliable operation, ASME FFS-1/API 579 (Fitness-For-Service) was implemented to address their integrity. The assessments consisted of finite element analysis techniques outlined in ASME Section VIII Div. 2 (design by analysis methods for pressure vessels), in accordance with the requirements of ASME FFS-1 Part 4: General Metal Loss, Part 5: Local Metal Loss, and Part 9: Crack Like Flaws. The assessments concluded that each heat exchanger is coined Fit For Service . The Fitness-For-Service standard offers a unique opportunity to facilities and institutions within the DOE National Lab complex to properly and safely assess the integrity of aging equipment necessary to conduct science and research. This poster demonstrates the assessment process and techniques used to determine the heat exchangers are fit for service.

Humenik, Alex [Fermilab]↗

Compact Counter Flow Fluidized Bed Heat Exchanger (Final Report)

Generation 3 concentrating solar power systems which utilize solid granular media as the heat transfer and storage media hold promise in reducing the levelized cost of electricity relative to generation 2 systems which utilize molten salt. The particles can be heated to temperatures exceeding 800 °C which enables the use of high efficiency supercritical CO 2 Brayton power cycles. A key challenge associate with the use of solid media is its low bulk thermal conductivity which limits the ability to transfer heat from the particles to a working fluid, such as supercritical CO 2 . Tradition shell and tube and shell and plate heat exchangers feature gravity driven particle flow which limits the maximum particle side heat transfer coefficient in these systems to approximately 400 W/m 2 K. A fluidized bed heat exchanger does not rely solely on gravity for particle flow. Instead, enhanced mixing and horizontal conveyance is achieved through fluidization induced through air injection at the bottom of a bed of particles. A tube bundle within the bed conveys the supercritical CO 2 which is heated via the turbulent particle motion at the tube wall.

14 SOLAR ENERGY↗

Nuclear Balance-of-Plant Analysis for Heat and Electricity Calculations in Several Advanced Nuclear Reactor Concepts

In addition to producing electricity, advanced nuclear reactors can also serve as a source of process heat for a wide range of industrial or residential applications. In cases where the heat application requires low-temperature heat, waste heat from the balance of plant (BOP) can be utilized with minimal impact on electricity generation. For applications requiring higher-temperature heat, heat can be extracted from the BOP, though this will reduce the amount of electricity generated. In either case, the optimal BOP design will be case-specific and depend on multiple factors, including the reactor type and the thermal requirements of the heat application.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ground heat exchanger design tool with rowwise placement of boreholes

Simulation-based design tools have been used since the late 1980s for designing ground heat exchangers (GHE) used with ground source heat pump (GSHP) systems. The ground heat exchanger simulations used in these tools rely on thermal response functions known as g-functions. Because of the significant computational burden in computing g-functions for even a single configuration, the design tools have relied on libraries of pre-computed g-functions. These g-functions were available for standard configuration shapes, such as lines, rectangles, open rectangles, L-shapes, and U-shapes. Standard shapes are often sub-optimal. For any building on a site, the available land may preclude use of a standard shape. For large GSHP systems with significantly imbalanced annual heat rejection and extraction loads, large rectangular fields may experience significant heat build-up (or heat draw-down) in the interior of the field. This paper describes a new ground heat exchanger design tool capable of automatically selecting and sizing both standard and irregular configurations. The focus of this paper is a method for creating, selecting and sizing irregular configurations where the available land area and "no-go" zones are described as irregular polygons.

Spitler, Jeffery↗

Quantifying the Agyrotropy of Proton and Electron Heating in Turbulent Plasmas

An important aspect of energy dissipation in weakly collisional plasmas is that of energy partitioning between different species (e.g., protons and electrons) and between different energy channels. Here we analyse pressure–strain interaction to quantify the fractions of isotropic compressive, gyrotropic, and nongyrotropic heating for each species. An analysis of kinetic turbulence simulations is compared and contrasted with corresponding observational results from Magnetospheric Multiscale Mission data in the magnetosheath. In assessing how protons and electrons respond to different ingredients of the pressure–strain interaction, we find that compressive heating is stronger than incompressive heating in the magnetosheath for both electrons and protons, while incompressive heating is stronger in kinetic plasma turbulence simulations. Concerning incompressive heating, the gyrotropic contribution for electrons is dominant over the nongyrotropic contribution, while for protons nongyrotropic heating is enhanced in both simulations and observations. Variations with plasma β are also discussed, and protons tend to gain more heating with increasing β.

79 ASTRONOMY AND ASTROPHYSICS↗

The mechanisms and seasonal differences of the impact of aerosols on daytime surface urban heat island effect

The urban heat island intensity (UHII) is the temperature difference between urban areas and their rural surroundings. It is commonly attributed to changes in the underlying surface structure caused by urbanization. Air pollution caused by aerosol particles can affect the UHII through changing (1) the surface energy balance by the aerosol radiative effect (ARE) and (2) planetary-boundary-layer (PBL) stability and airflow intensity by modifying thermodynamic structure, which is referred to as the aerosol dynamic effect (ADE). By analyzing satellite data and ground-based observations collected from 2001 to 2010 at 35 cities in China and using the WRF-Chem model, we find that the impact of aerosols on UHII differs considerably: reducing the UHII in summer but increasing the UHII in winter. This seasonal contrast is proposed to be caused by the different strengths of the ARE and ADE between summer and winter. In summer, the ARE on UHII is dominant over the ADE, cooling down surface temperature more strongly in urban areas than in rural areas because of much higher aerosol loading, and offsets the urban heating, therefore weakening UHII. In winter, however, the ADE is more dominant, because aerosols stabilize the PBL more in the polluted condition, weakening the near-surface heat transport over urban areas in both vertical and horizontal directions. This means that the heat accumulated in urban areas is dispersed less effectively, and thus the UHII is enhanced. These findings shed new light on the impact of the interaction between urbanization-induced surface changes and air pollution on urban climate.urban areas and their rural surroundings. It is commonly attributed to changes in the underlying surface structure caused by urbanization. Air pollution caused by aerosol particles can affect the UHII through changing (1) the surface energy balance by the aerosol radiative effect (ARE) and (2) planetary-boundary-layer (PBL) stability and airflow intensity by modifying thermodynamic structure, which is referred to as the aerosol dynamic effect (ADE). By analyzing satellite data and ground-based observations collected from 2001 to 2010 at 35 cities in China and using the WRF-Chem model, we find that the impact of aerosols on UHII differs considerably: reducing the UHII in summer but increasing the UHII in winter. This seasonal contrast is proposed to be caused by the different strengths of the ARE and ADE between summer and winter. In summer, the ARE on UHII is dominant over the ADE, cooling down surface temperature more strongly in urban areas than in rural areas because of much higher aerosol loading, and offsets the urban heating, therefore weakening UHII. In winter, however, the ADE is more dominant, because aerosols stabilize the PBL more in the polluted condition, weakening the near-surface heat transport over urban areas in both vertical and horizontal directions. This means that the heat accumulated in urban areas is dispersed less effectively, and thus the UHII is enhanced. These findings shed new light on the impact of the interaction between urbanization-induced surface changes and air pollution on urban climate.

54 ENVIRONMENTAL SCIENCES↗

Heat dissipation systems with hygroscopic working fluid

In various embodiments, the present invention relates to heat dissipation systems including a hygroscopic working fluid and methods of using the same. In various embodiments, the present invention provides a method for heat dissipation using a hygroscopic working fluid. The method can include transferring thermal energy from a heated process fluid to the hygroscopic working fluid in a process heat exchanger, to form a cooled process fluid. The method can include condensing liquid from a feed gas on a heat transfer surface of a feed gas heat exchanger in contact with the cooled process fluid, to form a cooled feed gas, the heated process fluid, and a condensate. The method can include dissipating thermal energy from the hygroscopic working fluid to a cooling gas composition with a fluid-air contactor. The method can include transferring moisture between the hygroscopic working fluid and the cooling gas composition with the fluid-air contactor. The method can include adding at least part of the condensate to the hygroscopic working fluid.

Martin, Christopher Lee↗

Heat Vulnerability Index Development and Mapping

Extreme heat is one of the leading causes of weather-related deaths in the U.S. Exposure to extreme heat will be exacerbated due to global climate change. It is thus crucial to design a key performance indicator, heat vulnerability index (HVI), to represent overall heat risk which can help identify susceptible regions and sub-populations in cities in the face of heatwaves. Most existing HVI tools only consider outdoor heat exposure. This paper developed an HVI web map tool incorporating both the outdoor and the indoor heat exposure, as well as population sensitivity and adaptation capability across census tracts in the city of Fresno, California. The tool can assist the planning of infrastructure and resources to reduce residents’ vulnerability to extreme heat events.

Xu, Yujie↗

Methods and apparatus for embedding heating circuits into articles made by additive manufacturing and articles made therefrom

Methods of embedding a heating circuit in an article fabricated by additive manufacturing. The methods describe techniques such as co-extruding a wire, capable of being heated, along with print material in additive manufacturing of the article, and placing a pre-shaped wire capable of being heated between adjacent layers of the article. A third method includes dispensing a wire, capable of being heated, during the additive manufacturing of the article, and compacting the wire into the printed material. An apparatus for embedding a heating circuit in an article fabricated by additive manufacturing. The apparatus contains a wire dispenser, a cutter to control the length of the wire dispensed, and a compactor capable of embedding the wire capable of being heated into the printed material. An article made by additive manufacturing is disclosed. The article contains at least one heating element embedded in the article during the additive manufacturing process.

Barocio, Eduardo↗

Heat treatment to anneal residual stresses during additive manufacturing

The present disclosure relates to a method of producing a product through additive manufacturing with heat treatment. The method involves using a fusing beam to melt powder particles disposed on a substrate, where the fusing beam is impressed with a two dimensional pattern containing image information from a first layer to be printed. The fused powder particles are then heat treated with a beam impressed with an additional two dimensional pattern. The additional two dimensional pattern has image information from the first layer to achieve heat treatment of the product. The heat treatment is completed prior to laying down additional new layers of material. The heat treatment is an annealing operation. The method may further involve providing a new layer of powdered material on top of the layer of fused powder particles subsequent to the heat treatment, and repeating the melting and heat treating operations in a layer-by-layer fashion using the two dimensional pattern and the additional two dimensional pattern, until the part is completed.

DeMuth, James A.↗

Modeling and Simulation of Air-Source CO2 Heat Pump Water Heater

Carbon dioxide (CO2) has been widely used as working fluid for the vapor-compression refrigeration systems in large marine device. Due to the potential energy efficiency and the favorable environmental properties of CO2 as a working fluid, CO2 heat pump water heater (HPWH) systems are regarded a promising technology for centralized domestic hot water (DHW) heating in residential and commercial buildings. However, there is still at the early stage of appropriately optimizing and improving the energy performance of CO2 HPWH. This requires CO2 HPWH simulation tools capable of capturing the accurate impact of the emerging compressor, throttle device, and heat exchanger technology on CO2 heat transfer and energy efficiency. In this study, high efficiency components (compressors, pumps, fans, heat exchangers) were identified and applied to the state-of-art CO2 HPWH designs and analyzed their performance by using numerical simulation. This was done by simulating the performance of CO2 HPWH using ACMODEL design model combined with the component models developed at Oak Ridge National Laboratory (ORNL) for orifice tube, map-based compressor, and tube-in-tube gas cooler. ACMODEL is an equipment design model for CO2-based air conditioners and heat pumps developed by Purdue University to account for the details of each component. The simulated CO2 HPWH performance was then compared with the heat pump water heater using conventional refrigerants.

Gao, Zhiming↗

Development of New g-function Data for Simulating a Novel Shallow Bore Ground Heat Exchanger

Geothermal heat pump (GHP), which is also referred as ground source heat pump, is the most energy-efficient technology for space heating and cooling. However, the application of GHP is hindered by its high initial cost, of which approximately 30% is for the ground heat exchanger (GHE). In recent years, researchers have developed different types of shallow bore ground heat exchangers (SBGHE) intending to reduce the cost of drilling. The ability to predict the thermal response of an SBGHE is critical for sizing SBGHE. While g-functions have been commonly used for predicting the thermal response of conventional vertical bore ground heat exchangers (VBGHE), they cannot be directly used for predicting the performance of SBGHE because they did not account for the impacts of the seasonal variation of the soil temperature along with the depth of an SBGHE. In addition, an SBGHE has a larger thermal mass within the borehole than the VBGHE due to the larger borehole diameter of SBGHE. This study develops new g-function data pairs for a new design of SBGHE, which is named Underground Thermal Battery (UTB). Impacts of the seasonal variation of soil temperature on the thermal response of UTB were accounted for by superposing a time-dependent soil temperature onto the g-functions calculated with a numerical model that assumes constant undisturbed soil temperature. The TOUGH program was used to predict the thermal response of several configurations involving multiple UTBs. The results indicate that the proposed methodology is appropriate to generate g-functions for the UTB, and the g-function value of UTB is much lower than that of VBGHE in the time range of 15 min to 1 year due to the large thermal mass and convection heat transfer within the UTB.

Shi, Liang↗

Combined cooling, heating and power system

A combined cooling, heating, and power system, including a working fluid cycling between a compressor and a turbine in combination with a power generator. A humidifying regenerator is disposed between the compressor and the turbine, and in combination with the working fluid upstream and again downstream of the turbine to humidify and then dehumidify the working fluid. A working fluid heat exchanger is in combination with the working fluid between the turbine and the humidifying regenerator for further heat the working fluid. The heat exchanger is in combination with a heat source that heats both the working fluid and provides a separate heating medium. A cooling device is in combination with the working fluid between the humidifying regenerator and the compressor, wherein the cooling device cools the working fluid before entering the compressor and provides a separate cooling medium.

Kozlov, Aleksandr↗

Heat transfer systems for nuclear reactor cores, and related systems

A system for transferring heat from a nuclear reactor comprises a nuclear reactor comprising a nuclear fuel and a reactor vessel surrounding the nuclear reactor and a heat transfer system surrounding the nuclear reactor. The heat transfer system comprises an inner wall surrounding the nuclear reactor vessel, first fins coupled to an outer surface of inner wall, an outer wall between the inner wall and a surrounding environment, and second fins coupled to an inner surface of the outer wall and extending in a volume between the outer surface of the inner wall and the inner surface of the outer wall, the outer surface of the inner wall and the first fins configured to transfer heat from the nuclear reactor core to the second fins and the inner surface of the outer wall by thermal radiation. The heat transfer system may be directly coupled to the nuclear reactor vessel, or may be coupled to an external reflector surrounding the nuclear reactor vessel. Related heat transfer systems and systems for selectively removing heat from a nuclear reactor are disclosed.

Ougouag, Abderrafi Mohammed El-Amine↗

Multifunctional Heat Pump with Energy Storage Capability

Replacing gas furnaces with heat pumps on a large scale can pose challenges to the electrical grid. It will significantly increase the demand, strain the electrical grid, especially during peak usage times. To ensure that heat pumps contribute to reducing emissions, it's essential to increase the share of renewable energy in the grid. However, the supply of renewable energy is unstable. Large scale of electrification must address the concern of grid resilience to meet necessary heating/cooling demands and shift peak electric load. All these require future heat pumps having energy storage capability. These systems can store excess energy during low-demand periods and release it during high-demand periods, reducing stress on the grid. This paper will introduce an innovative configuration, control, and laboratory investigations of a multifunctional packaged heat pump. In addition to the original indoor and outdoor air coils, the heat pump has a parallel hydronic loop with a brazed plate heat exchanger (BHP). The hydronic loop circulates hot/chilled water to store heating/cooling energy in phase change material (PCM). It is capable of space cooling, space heating, cooling energy storage/defrosting, water heating/heating energy storage with outdoor air source or indoor air source, and cooling/heating energy free discharge. The laboratory studies and breadboard unit are presented. Additionally, building energy simulation demonstrates utility cost reduction potential via charging PCM panels/ceilings during off-peak hours and releasing the energy during peak hours to mitigate the peak power consumption.

Shen, Bo↗

Methods and apparatus for embedding heating circuits into articles made by additive manufacturing and articles made therefrom

Methods of embedding a heating circuit in an article fabricated by additive manufacturing. The methods describe techniques such as co-extruding a wire, capable of being heated, along with print material in additive manufacturing of the article, and placing a pre-shaped wire capable of being heated between adjacent layers of the article. A third method includes dispensing a wire, capable of being heated, during the additive manufacturing of the article, and compacting the wire into the printed material. An apparatus for embedding a heating circuit in an article fabricated by additive manufacturing. The apparatus contains a wire dispenser, a cutter to control the length of the wire dispensed, and a compactor capable of embedding the wire capable of being heated into the printed material. An article made by additive manufacturing is disclosed. The article contains at least one heating element embedded in the article during the additive manufacturing process.

Barocio, Eduardo↗

Aircraft electric motor having a stator heat pipe cooling scheme

Aircraft electric motors are described. The aircraft electric motors include a motor unit having a rotor and a stator, wherein the stator includes a plurality of windings and cooling channels arranged to provide cooling to the plurality of windings, a drive unit configured to drive operation of the motor unit, and a cooling system. The cooling system includes an oscillating heat pipe containing a first working fluid, wherein the oscillating heat pipe is arranged to pick up heat from at least one winding, the oscillating heat pipe having an evaporator section arranged in thermal contact with the at least one winding and a condenser section arranged away from the evaporator section and a heat pickup portion arranged to receive a second working fluid to remove heat from the condenser section of the oscillating heat pipe.

Saviers, Kimberly Rae↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.