Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma rays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

FPMS_XPeRT_INL_Poster

As nuclear energy expands and experimental programs increasingly rely on the facilities at Idaho National Laboratory (INL) for reactor and fuel testing, research capabilities must also expand to meet these demands. A new Fission Product Monitoring System (FPMS) has been deployed at the Advanced Test Reactor (ATR) at the Auxiliary Lead-out Experiment (ALE) House to support this expanding fuel testing mission. By tracking gaseous fission products releases from test fuel in near real-time, release rates, calculated from FPMS data, can be used to characterize the effectiveness of fuel cladding, especially for Tri-structural Isotropic (TRISO) fuel concepts. The new iteration of the FPMS supports up to 14 fission product monitors for online fission-product tracking via gamma-ray spectroscopy of the experiment’s effluent gas. Each monitor consists of a nominally 10% HPGe detector housed in a copper-lined lead shield with a warm gas trap. The new system features gamma-ray count rate information with a five-second temporal resolution and provides isotopic activity every five minutes, capable of resolving multiple overlapping fission product releases over a broad range of activities in near real-time. This work includes data from ATR cycle 175D data to demonstrate these capabilities. The hourly resolution data shows general trends and significant releases over the cycle, while the 5-minute resolution data allows for a more detailed examination of events due to unexpected particle releases.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

The polarization sensitivity of GRETINA

Compton polarimeters have played an important role in the study of nuclear structure physics, but have often been limited in their applications because of relatively low -ray detection efficiency. With the advent of -ray tracking detector arrays, which feature nearly solid angle coverage and the ability to identify the location of Compton-scattering events to within a few millimeters, this limitation can be overcome. Here we present a characterization of the performance of the Gamma Ray Energy Tracking In-beam Nuclear Array (GRETINA) as a Compton polarimeter using the 24 Mg(p,p') reaction at 2.45 MeV proton energy. We also discuss a new capability added to the simulation package UCGretina to simulate the emission of polarized photons, and compare it to the measured data. Lastly, we use these simulations to predict the performance of the Gamma Ray Energy Tracking Array (GRETA).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A compact neutron spectrometer system

A portable neutron spectrometer, nSpec, has been developed for passive interrogation of fast neutrons ( 1 MeV) from neutron sources. The design of the system includes four EJ-301 liquid scintillation cells, a custom stand, and tungsten caps for gamma-ray shielding. Data acquisition settings were optimized to provide a dynamic range of up to > 15 MeV neutron energy. Additionally, the detector response matrix was characterized using a time-of-flight method based on gamma-ray tagged neutron emission from 252 Cf. The spectrum unfolding was characterized using measured and simulated spectra of AmBe and 252 Cf with the GRAVEL and MLEM methods. Monte Carlo methods were used to examine the uncertainty propagation and determine sufficient counts for a measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved plutonium and americium photon branching ratios from microcalorimeter gamma spectroscopy

Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution - (60–70 eV full-width-at-half-maximum at 100 keV) gamma-ray spectra acquired using microcalorimeter sensors to substantially reduce the uncertainties for 11 plutonium ( 238 Pu, 239 Pu, 241 Pu) and 241 Am branching ratios important for material control and accountability and nuclear forensics in the energy range of 125 keV to 208 keV. Lastly, we show a reduction in uncertainty of over a factor of three for one branching ratio and a factor of 2–3 for four branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutrondiagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maximum Likelihood Spectrum Decomposition for Isotope Identification and Quantification

A spectral decomposition method has been implemented to identify and quantify isotopic source terms in high-resolution gamma-ray spectroscopy in static geometry and shielding scenarios. Monte Carlo simulations were used to build the response matrix of a shielded high-purity germanium detector monitoring an effluent stream with a Marinelli configuration. The decomposition technique was applied to a series of calibration spectra taken with the detector using a multi-nuclide standard. These results are compared with decay-corrected values from the calibration certificate. For most nuclei in the standard ( 241 Am, 109 Cd, 137 Cs, and 60 Co), the deviations from the certificate values were generally no more than 6% with a few outliers as high as 10%. Furthermore, for 57 Co, the radionuclide with the lowest activity, the deviations from the standard reached as high as 25%, driven by the meager statistics in the calibration spectra. In addition, a complete treatment of error propagation for the technique is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Implementation of a System of Gamma Imagers for Measuring Plutonium Holdup

The Surplus Plutonium Disposition (SPD) project is an effort to dilute and dispose of many tonsof weapons grade plutonium. This work will take place in a shielded glovebox to protect workers fromradiological dose. Accurate measurements of the holdup, or material left behind, in the gloveboxes is im-portant for Nuclear Material Control and Accountancy, worker dose minimization, criticality safety, andprocess monitoring. Shielding around the gloveboxes presents an obstacle for the traditional GeneralizedGamma Holdup (GGH) method. The uncertainties associated with that method, at around 28%, arealso detrimental since the amount of holdup must be kept below an established limit with a high level ofconfidence.Passive gamma-ray imaging provides a more complete depiction of the distribution of radioactivematerials. Recent refinement of the method has demonstrated that quantitative information can beextracted from the images with a well-characterized system. A permanently installed system of gamma-ray imagers is currently being developed to measure plutonium holdup in the SPD gloveboxes. Thispaper will report on progress with the development of this system.This application requires that the features of current commercially available instruments from H3Dand PHDS, optimized for measurement performance in a mobile application, be translated into theconstraints of the operational environment with fixed installations. The interaction between facilityconstraints and measurement capabilities will be addressed.A series of measurements with plutonium sources in a mocked-up glovebox geometry with imagersmounted above the ceiling of the glovebox have been taken. Imager performance with respect to angularresolution, minimum measurement time for quantification, and signal-to-noise ratio with a multitudeof sources will be evaluated for those measurements. A series of prototypes of user interfaces will bepresented for display of the data to its various consumers for the purposes of Nuclear Material Controland Accountancy, worker dose minimization, criticality safety, and process monitoring.

Schmitt, Kyle↗

Detectors and Data [Slides]

Summary: A gamma-ray spectrum is a histogram of energy deposited in a detector and a ‘fingerprint’ for a particular radionuclide. Shielding can reduce the intensity of peaks in a spectrum, especially at lower energies. HPGe detectors provide the sharpest picture in terms of gamma ray data. Regarding moderation and ³He detectors–too little and neutrons are too fast to be detected; too much and neutrons may get absorbed before reaching the ³He tube.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Open string QED meson description of the X17 particle and dark matter

As a quark and an antiquark cannot be isolated, the intrinsic motion of a composite $q\overline{q}$ system in its lowest-energy states lies predominantly in 1+1 dimensions, as in an open string with the quark and the antiquark at its two ends. Accordingly, we study the lowest-energy states of an open string $q\overline{q}$ system in QCD and QED in 1+1 dimensions. We show that π 0 , η, and η' can be adequately described as open string $q\overline{q}$ QCD mesons. By extrapolating into the $q\overline{q}$ QED sector in which a quark and an antiquark interact with the QED interaction, we find an open string isoscalar I(J π ) = 0(0 - ) QED meson state at 17.9±1.5 MeV and an isovector (I(J π ) = 1(0 - ), I 3 = 0) QED meson state at 36.4±3.8 MeV. The predicted masses of the isoscalar and isovector QED mesons are close to the masses of the hypothetical X17 and E38 particles observed recently, making them good candidates for these particles. The decay products of QED mesons may show up as excess e + e - and γγ pairs in the anomalous soft photon phenomenon associated with hadron productions in high-energy hadron-proton collisions and e + -e - annihilations. Measurements of the invariant masses of excess e + e - and γγ pairs will provide tests for the existence of the open string $q\overline{q}$ QED mesons. An assembly of gravitating QED mesons are expected to emit electron-positron pairs and/or gamma rays and their decay energies and lifetimes will be modified by their gravitational binding energies. Consequently, a self-gravitating isoscalar QED meson assembly whose mass M and radius R satisfy (M/M ⊙ )/(R/R ⊙ ) ≳ 2 4.71 × 10 5 will not produce electron-positron pairs nor gamma rays and may be a good candidate for the primordial dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Systematic evaluation of fast neutron sensing with Cesium Hafnium Chloride

Cesium Hafnium Chloride (CHC) is a promising new scintillator for dual mode sensing of both neutrons and gamma-rays. The high chlorine content allows for both 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P reaction channels leading to reliable detection of fast neutrons. By utilizing pulse shape discrimination (PSD), these neutron interactions may be reliably separated from gamma-ray signals with a high figure-of-merit (FOM) after optimization of the PSD algorithm. Here, in this study, the PSD algorithm settings for CHC were systematically investigated using a bare 252 Cf and a lead shielded plutonium beryllium neutron source. It was found that the PSD algorithm settings affects both the FOM and the neutron detection efficiency, but a FOM as high as 4.5 for alpha particles was observed in one data processing scenario. Further, an intrinsic 5 parts per million alpha emitting contamination was observed in the sample, which we attribute to natural uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boson Fermion Nucleus Explanation for Violation of Parity in the Radioactive Decay of Cobalt-60: Monograph #12

In 1957, Chien-Shuing Wu subjected cobalt-60 to supercooled temperatures and a strong magnetic field while measuring radioactive decay. This experiment showed violation of parity— a long-held, fundamental precept in physics stating that nuclear radioactive-decay emission flux will not vary in the solid angle about the nucleus. During Wu’s experiment, beta particles (electrons) exhibited asymmetry, preferentially exiting the cobalt-60 nuclei in the polar region opposite the applied magnetic field. Gamma-ray emissions were anisotropic, preferring to exit the nucleus around the equatorial region. The boson fermion nucleus (BFN) explains the origins of these observed phenomena, where the nuclear structure is pinned in the strong magnetic field with minimal motion in supercooled conditions, while beta particles and gamma rays are emitted from specific locations within the nuclear structure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fixed-Energy Response-Function Analysis with Multi-Efficiency (FRAM) Software, Version 6

Researchers at Los Alamos National Laboratory have developed FixedEnergy Response- Function Analysis with Multiple Efficiency (FRAM), a powerful software tool for gamma-ray spectrometry isotopic analysis. This tool leverages Los Alamos expertise in nuclear safeguards, radiation detection systems, and related analysis techniques. A household name in the non-destructive assay community for over two decades, FRAM determines a special nuclear material source's isotopic composition by analyzing gamma-ray spectra. Los Alamos researchers have released the latest version of FRAM that incorporates several updates to the 2013 major release of FRAM, Version 5.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimization of an Energy Tuning Assembly for High Explosives Detection

The Portable Isotopic Neutron Spectroscopy (PINS) system, employs neutron-induced gamma-ray spectroscopy and provides a nondestructive method for high explosives detection. In standard operation it uses Californium-252 as a neutron source. Operating PINS with a deuterium-tritium (DT) neutron generator has some advantages over Cf-252, including lifetime and ability to produce high-energy inelastic scattering gamma rays. However, current systems using DT neutron generators suffer from a high environmental background and reduced ability to induce neutron capture, reducing spectral quality and limiting nitrogen sensitivity. Here, this study presents the development of an energy-tuning assembly (ETA) designed to optimize the DT neutron energy spectrum to increase nitrogen reaction rates in a target, thereby improving high explosive detection capabilities. A metaheuristic optimization framework, MultiGNOWEE, coupled with MCNP, was employed to generate two ETA configurations: a single-objective ETA, which maximizes nitrogen capture reactions, and a multi-objective ETA, which balances neutron capture and inelastic scattering. Simulations demonstrated the optimized configurations achieved up to a 10-fold improvement in nitrogen capture rates compared to the bare configuration. Experimental validation was conducted using a DT neutron generator and a high-purity germanium (HPGe) detector. Two prototype ETAs were constructed and assessed on a melamine simulant. Measurements demonstrated improved nitrogen detection for both prototype ETA configurations when compared to the standard system.

97 MATHEMATICS AND COMPUTING↗

Los Alamos National Laboratory: SULI Appointment

The progenitors of gamma-ray bursts - the brightest explosions in our universe - are still poorly understood. It has been suggested that massive stars collapsing in interacting binary systems (i.e. with a closely orbiting compact object companion) can provide the necessary angular momentum and dense surrounding medium to explain observations of radio-loud gamma-ray bursts. We explore this progenitor system using the population synthesis code COSMIC. We explore the dependence of the properties of an interacting binary systems - including the remnant types and their masses - on metallicity and mass raction of the binary system. We also explore how the rates of populations of these systems depend on metallicity. Our findings help constrain what properties lead to viable GRB progenitors, especially radio loud GRBs.

79 ASTRONOMY AND ASTROPHYSICS↗

Improving Fission Products at CARIBU: Near Field Detection (Q2/FY24 Quarterly Progress Report)

We continue to make progress in the analysis of 111 Ag decay data to determine gamma-ray intensities with the aim of improving these intensities to below 1% precision. The correctness of detection efficiencies is integral to obtaining accurate and precise results. While Geant4 provides us with efficiencies for detection of a coincidence event of a beta-particle with a 96, 245, or 342 gamma-ray, as outlined in Figure 1, it is important that we validate these results with the efficiencies obtained from the experimental decay data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

dSph-obic dark matter

We present a mechanism that allows thermal relic dark matter to annihilate efficiently in the Galactic Halo and in galaxy clusters, but not in the lower-velocity environments of dwarf spheroidal (dSph) galaxies. We realize this within a complete model in which the dark matter consists of two distinct states separated by a small mass splitting. An indirect detection signal is generated only through the coannihilations of these two states, requiring both to be present. In the halo of the Milky Way, the dark matter particles in the lighter state can be excited into the long-lived heavier state through scattering. Once excited, these heavier particles can coannihilate with those in the lighter state, yielding a gamma-ray signal with little or no suppression. By contrast, the dark matter particles in dwarf galaxies do not possess enough kinetic energy to be excited, thereby suppressing the coannihilation rate and corresponding indirect detection signals from those systems. This framework breaks the predictive relationship that ordinarily exists between these respective gamma-ray signals and complicates our ability to interpret the results of indirect detection searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cross Section Measurements of Photonuclear Reaction Pathways Towards Promising Medical Radioisotopes

Project Objectives: The goal of this project was to generate data relevant to radioisotope production while developing innovative technologies that foster and enhance novel production of radioisotopes, and, also, while providing opportunities for cultivating and training future generations of scientists. This work has provided the foundation for methodologies for determination of photonuclear cross sections over multiple energies in a single irradiation. Simultaneously, the feasibility of electron LINAC production of several in-demand radioisotopes such as 47 Sc, 67 Cu, 77 As, and 186 Re has been demonstrated. To accomplish these objectives a collaboration was formed between two complimentary facilities, the Low Energy Accelerator Facility (LEAF) at Argonne National Laboratory and the High Intensity Gamma-ray Source (HIGS) at Triangular Universities Nuclear Laboratory (TUNL). The involvement of the research group from North Carolina Central University gave students at this Historically Black University experience in forefront nuclear-physics research relevant to addressing a high-priority interdisciplinary issue. Project Description: HIGS provides a nearly monoenergetic gamma-ray beam by intra-cavity Compton backscattering of free-electron photons from electrons circulating in a storage ring. This beam can be collimated to produce a very precise energy beam. If the beam is un-collimated a calculated and precise energy spread of the beam occurs radially. The γ-flux can be evenly distributed over the radial distribution of energy and used to perform activation experiments on concentric ring targets. Thus providing multiple energy ranges in a single irradiation. Each concentric ring target can be counted separately in order to determine activation at the given energy and successively be correlated to the activation cross section. Targets were activated to determine production feasibility using electron beams at LEAF. Potential Impact: The Nuclear Science Advisory Committee recently named production of radioisotopes with electron LINACs as one of the most compelling and largest-impact opportunities for the production of high specific activity radioisotopes. Improving the photonuclear cross sectional data base with experimentally verified results will greatly enhance a researcher’s ability to rationalize electron LINAC production routes towards desired radioisotopes. This work will provide the foundation for methodologies for determination of photonuclear cross sections over multiple energies and multiple targets in a single irradiation. The techniques developed in this project will enable future studies to continue verifying theoretically predicted photonuclear cross section with experimental results. These data will also enable adaptation of models and support more precise theoretical calculation of photonuclear cross sections. This research will involve undergraduates, graduate students, and post-docs to give them a valuable research experience leading towards the next generation of scientists in the field of medical isotopes.

07 ISOTOPE AND RADIATION SOURCES↗