Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fringe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Density measurements using coherence imaging spectroscopy based on Stark broadening

A coherence imaging camera has been set up at Pilot-PSI. The system is to be used for imaging the plasma density through the Stark effect broadening of the H{sub {gamma}} line. Local density values are then obtained by the Abel inversion of the measured interferometric fringe contrast. This report will present the instrument setup and proof-of-principle demonstration. The inverted spatial electron density profiles obtained near the cascaded arc source of Pilot-PSI in discharges with axial magnetic field of B=0.4 T are compared with an independent measurement of electron density by Thomson scattering and good agreement is found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collimator Magnet with Functionally Defined Profile for Ion Implantation

Advanced implantation systems used for semiconductor processing should have high precision of ion beam collimation (+/-0.1 deg and better) and wide beam aperture (400 mm and more). Typical arrangements of ion implantation systems include beam scanning (BSM) and collimator magnets (CM). Standard collimator magnets have limited precision of beam collimation due to magnetic poles that have piecewise circular profile. This study proposes a novel ''constant sum angle collimator magnet''(CSACM) with non-circular magnetic pole profile. Angles of incidence {alpha}{sub i} and exit {alpha}{sub e} are defined as angles between ion trajectory and local normal to CM input/output magnetic pole edge. Profile of the CSACM is defined as having constant algebraic sum {alpha}{sub i}+{alpha}{sub e} = const for every ion trajectory of the scanned beam, in addition to ''usual'' beam collimation. An iterative procedure allows improve CSACM taking into account magnetic fringe field effects. Simulation results prove that CSACM assures precise beam collimation in two orthogonal planes. Circular approximations for CSACM magnetic poles are proposed. The model may be further developed for global design of the ion beam line (BSM+CM) and for taking into account space-charge effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Event-based Simulation Model for Quantum Optics Experiments

We present a corpuscular simulation model of optical phenomena that does not require the knowledge of the solution of a wave equation of the whole system and reproduces the results of Maxwell's theory by generating detection events one-by-one. The event-based corpuscular model gives a unified description of multiple-beam fringes of a plane parallel plate and single-photon Mach-Zehnder interferometer, Wheeler's delayed choice, photon tunneling, quantum eraser, two-beam interference, double-slit, Einstein-Podolsky-Rosen-Bohm and Hanbury Brown-Twiss experiments. We also discuss the possibility to refute our corpuscular model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The electric Aharonov-Bohm effect

The seminal paper of Aharonov and Bohm [Phys. Rev. 115, 485 (1959)] is at the origin of a very extensive literature in some of the more fundamental issues in physics. They claimed that electromagnetic fields can act at a distance on charged particles even if they are identically zero in the region of space where the particles propagate, that the fundamental electromagnetic quantities in quantum physics are not only the electromagnetic fields but also the circulations of the electromagnetic potentials; what gives them a real physical significance. They proposed two experiments to verify their theoretical conclusions. The magnetic Aharonov-Bohm effect, where an electron is influenced by a magnetic field that is zero in the region of space accessible to the electron, and the electric Aharonov-Bohm effect where an electron is affected by a time-dependent electric potential that is constant in the region where the electron is propagating, i.e., such that the electric field vanishes along its trajectory. The Aharonov-Bohm effects imply such a strong departure from the physical intuition coming from classical physics that it is no wonder that they remain a highly controversial issue after more than fifty years, in spite of the fact that they are discussed in most of the text books in quantum mechanics. The magnetic case has been studied extensively. The experimental issues were settled by the remarkable experiments of Tonomura et al. [Phys. Rev. Lett. 48, 1443 (1982); Phys. Rev. Lett. 56, 792 (1986)] with toroidal magnets, that gave a strong evidence of the existence of the effect, and by the recent experiment of Caprez et al. [Phys. Rev. Lett. 99, 210401 (2007)] that shows that the results of the Tonomura et al. experiments cannot be explained by the action of a force. The theoretical issues were settled by Ballesteros and Weder [Commun. Math. Phys. 285, 345 (2009); J. Math. Phys. 50, 122108 (2009); Commun. Math. Phys. 303, 175 (2011)] who rigorously proved that quantum mechanics predicts the experimental results of Tonomura et al. and of Caprez et al. The electric Aharonov-Bohm effect has been much less studied. Actually, its existence, that has not been confirmed experimentally, is a very controversial issue. In their 1959 paper Aharonov and Bohm proposed an ansatz for the solution to the Schroedinger equation in regions where there is a time-dependent electric potential that is constant in space. It consists in multiplying the free evolution by a phase given by the integral in time of the potential. The validity of this ansatz predicts interference fringes between parts of a coherent electron beam that are subjected to different potentials. In this paper we prove that the exact solution to the Schroedinger equation is given by the Aharonov-Bohm ansatz up to an error bound in norm that is uniform in time and that decays as a constant divided by the velocity. Our results give, for the first time, a rigorous proof that quantum mechanics predicts the existence of the electric Aharonov-Bohm effect, under conditions that we provide. We hope that our results will stimulate the experimental research on the electric Aharonov-Bohm effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New Nanoscale Imaging with a Simple Hard X-Ray Nanoslit

A simple and new procedure to measure the optimal intensity distribution of an x-ray wavefield in nanoscale resolution is proposed. A heavy-metal wire can work as a ''nanoslit'' with a nanoscale aperture size. Its basic function can be described simply with geometrical optics using total reflection. The further function is investigated with numerical calculation of a diffraction edge. In the experiment, Fresnel fringes generated by a rectangular aperture were measured by using a 300-{mu}m platinum wire as the nanoslit. Its high potential use in imaging applications is discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Optic-microwave mixing velocimeter for superhigh velocity measurement

The phenomenon that a light beam reflected off a moving object experiences a Doppler shift in its frequency underlies practical interferometric techniques for remote velocity measurements, such as velocity interferometer system for any reflector (VISAR), displacement interferometer system for any reflector (DISAR), and photonic Doppler velocimetry (PDV). While VISAR velocimeters are often bewildered by the fringe loss upon high-acceleration dynamic process diagnosis, the optic-fiber velocimeters such as DISAR and PDV, on the other hand, are puzzled by high velocity measurement over 10 km/s, due to the demand for the high bandwidth digitizer. Here, we describe a new optic-microwave mixing velocimeter (OMV) for super-high velocity measurements. By using currently available commercial microwave products, we have constructed a simple, compact, and reliable OMV device, and have successfully obtained, with a digitizer of bandwidth 6 GH only, the precise velocity history of an aluminum flyer plate being accelerated up to 11.2 km/s in a three stage gas-gun experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A very low energy compact electron beam ion trap for spectroscopic research in Shanghai

In this paper, a new compact low energy electron beam ion trap, SH-PermEBIT, is reported. This electron beam ion trap (EBIT) can operate in the electron energy range of 60-5000 eV, with a current density of up to 100 A/cm{sup 2}. The low energy limit of this machine sets the record among the reported works so far. The magnetic field in the central drift tube region of this EBIT is around 0.5 T, produced by permanent magnets and soft iron. The design of this EBIT allows adjustment of the electron gun's axial position in the fringe field of the central magnetic field. This turned out to be very important for optimizing the magnetic field in the region of the electron gun and particularly important for low electron beam energy operation, since the magnetic field strength is not tunable with permanent magnets. In this work, transmission of the electron beam as well as the upper limit of the electron beam width under several conditions are measured. Spectral results from test operation of this EBIT at the electron energies of 60, 315, 2800, and 4100 eV are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Capillary Absorption Spectrometer for Stable Carbon Isotope Ratio (13C/12C) Analysis in Very Small Samples

A capillary absorption spectrometer (CAS) suitable for IR laser isotope analysis of small CO{sub 2} samples is presented. The system employs a continuous-wave (cw) quantum cascade laser to study nearly adjacent rovibrational transitions of different isotopologues of CO{sub 2} near 2307 cm{sup -1} (4.34 {mu}m). This initial CAS system can achieve relative isotopic precision of about 10 ppm {sup 13}C, or {approx}1{per_thousand} (per mil in delta notation relative to Vienna Pee Dee Belemnite) with 20-100 picomoles of entrained sample within the hollow waveguide for CO{sub 2} concentrations {approx}400 to 750 ppm. Isotopic analyses of such gas fills in a 1-mm ID hollow waveguide of 0.8 m overall physical path length can be carried out down to {approx}2 Torr. Overall {sup 13}C/{sup 12}C ratios can be calibrated to {approx}2{per_thousand} accuracy with diluted CO{sub 2} standards. A novel, low-cost method to reduce cw-fringing noise resulting from multipath distortions in the hollow waveguide is presented, which allows weak absorbance features to be studied at the few ppm level (peak-to-rms) after 1,000 scans are co-added in {approx}10 sec. The CAS is meant to work directly with converted CO{sub 2} samples from a Laser Ablation-Catalytic-Combustion (LA CC) micro-sampler to provide {sup 13}C/{sup 12}C ratios of small biological isolates with spatial resolutions {approx}50 {mu}m.

47 OTHER INSTRUMENTATION↗

RECOVERING A SHORT TIMESCALE SIGNAL FROM A PAIR OF LONG-DELAY VISARS

We introduce the benefits of analyzing VISAR data in the Fourier domain, particularly for recovering the short time scale signal component. In particular, by combining data from two VISARS having different long delays, we effectively reproduce the short time resolution ability of a short delay while retaining the superior sensitivity to absolute velocity of a long delay. Two different delays are generally desired, not only to untangle integer fringe skips, but to circumvent the fact that a single VISAR cannot record signal components of frequencies periodic with its reciprocal delay. Combining two different delays solves this. We treat the VISARs as linear filters and process and combine the signals in the Fourier domain with a direct equation, without any iteration of time-retarded equations. The technique is demonstrated with a numerical simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementation of moire-schlieren deflectometry on a small scale fast capillary plasma discharge

We present the results of an implementation of a refractive diagnostic to study fast dynamics in capillary discharges. It consists of a moire-schlieren deflectometry technique that provides a quantitative analysis of the refractive index gradients. The technique is composed of an angular deflection mapping system (moire deflectometry) and a spatial Fourier filter (schlieren). Temporal resolution of 12 ps, 50 {mu}m of spatial resolution and minimum detectable gradient of ({nabla}n{sub e}){sub min}=6x10{sup 18}cm{sup -4} were obtained. With these parameters, a large aspect ratio capillary discharge of 15 ns half period current was studied; the diagnostic was implemented axially along the alumina tube of 1.6 mm inner diameter and 21 mm length. The detectable electron density for these conditions was 1x10{sup 17}cm{sup -3}. From the interpretation of the fringe displacement, we are able to measure the velocity of the radial compression wave and the compression ratio due to the Lorentz force. On axis, electron densities of the order of 5x10{sup 17}cm{sup -3} were obtained at the time of maximum soft x-ray emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Velocity-map imaging at low extraction fields

We present a velocity-map imaging (VMI) setup for photoelectron imaging that utilizes low electric extraction fields. This avoids any complications that could arise from electrostatic interactions between the extraction field and the molecular properties that are probed and has a minimal effect on the trajectory of ions in ion beam experiments. By using an attractive potential supplied to the detector, and keeping the electrodes at ground (zero) potential, we show that fringe fields between the VMI arrangement and the vacuum chamber can be eliminated, which is important in experiments on ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of excited states of Sb impurity in Si by traveling–wave method

The ground and excited states of Sb atom in Si, 1s (A{sub 1}), 1s (T{sub 2}), 1s (E), and 2p{sup 0}, were measured by using a traveling-wave method. The Sb-doped Si crystal with donor concentration of 2 × 10{sup 15} cm{sup −3} was placed the distance of 5 μm above a piezoelectric crystal in the fringe field of a surface acoustic wave. The free electrons excited from the bound states of the Sb atom are drifted by the traveling-wave, and thus lose their energy as the Joule heat through lattice and ion scattering processes. A strong temperature-dependent energy loss of the traveling-wave can be observed at temperatures below 200 K. The values of the bound states of the Sb atom can be characterized by using the Arrhenius plot for thermal activation process of the electrons in the bound states. The measurements were carried out at two frequencies of the traveling-wave, 50 MHz and 200 MHz. At the frequency of 50 MHz, the dielectric properties of the Si crystal are governed by dopant polarization but by electronic polarization at 200 MHz. We found that measurement accuracy of the bound states depends mainly on the electron mobility and the dielectric constant of the Si crystal, which are sensitive to the frequency and strength of the traveling-wave as well as electronic polarization properties of the Si crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and implementation of a multichannel millimeter wave interferometer for the Compact Toroidal Hybrid experiment

A three-channel 1 mm wave interferometer has been designed, assembled, and installed on the Compact Toroidal Hybrid torsatron (CTH). The interferometer design makes novel use of a subharmonic mixer for detection, which simplifies alignment. It employs a single electronically tunable source that is repetitively chirped using a sawtooth waveform of frequency up to 1 MHz. The 15.25 GHz drive oscillator is multiplied in two stages to 122 GHz before a final doubler stage brings it to 244 GHz. Local oscillator (LO) power at 122 GHz is directed through waveguide to the LO input of the subharmonic mixer of each viewing chord, simplifying alignment. Phase detection is performed by directly digitizing the amplified mixer outputs at 50 MHz and processing them with a software algorithm. Initial measurements made with the central chord of the new interferometer agree with those from the existing 4 mm system at low densities. The 1 mm system performs well in current-driven discharges reaching densities over 10{sup 19} m{sup -3}, whereas the lower frequency interferometer is found to be less reliable due to loss of fringes. This is a critical improvement for experiments studying the onset, avoidance, and vacuum magnetic transform dependence of disruptions in the CTH device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of a charge-state analyzer for electron cyclotron resonance ion source beams

A detailed experimental and simulation study of the extraction of a 24 keV He{sup +} beam from an ECR ion source and the subsequent beam transport through an analyzing magnet is presented. We find that such a slow ion beam is very sensitive to space-charge forces, but also that the neutralization of the beam's space charge by secondary electrons is virtually complete for beam currents up to at least 0.5 mA. The beam emittance directly behind the extraction system is 65 {pi} mm mrad and is determined by the fact that the ion beam is extracted in the strong magnetic fringe field of the ion source. The relatively large emittance of the beam and its non-paraxiality lead, in combination with a relatively small magnet gap, to significant beam losses and a five-fold increase of the effective beam emittance during its transport through the analyzing magnet. The calculated beam profile and phase-space distributions in the image plane of the analyzing magnet agree well with measurements. The kinematic and magnet aberrations have been studied using the calculated second-order transfer map of the analyzing magnet, with which we can reproduce the phase-space distributions of the ion beam behind the analyzing magnet. Using the transfer map and trajectory calculations we have worked out an aberration compensation scheme based on the addition of compensating hexapole components to the main dipole field by modifying the shape of the poles. The simulations predict that by compensating the kinematic and geometric aberrations in this way and enlarging the pole gap the overall beam transport efficiency can be increased from 16% to 45%.

43 PARTICLE ACCELERATORS↗

Upgrade of the JET far infrared interferometer diagnostic

In recent years there has been a major upgrade of the JET far infrared diagnostic system consisting of a new laser system with the wavelength at 118.8 {mu}m at and more advanced processing electronics for phase counting. This provides a second colour measurement of the electron plasma density on the vertical system. Due to the shorter wavelength, the plasma induced laser beam refraction is reduced by a factor of three alleviating density errors caused by loss of signal (so-called 'fringe jumps'[A. Murari et al., Rev. Sci. Instrum. 77, 073505 (2006)]), in particular during high performance plasmas experiments in JET.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Talbot-Lau interferometer for high-speed phase imaging and tomography using white synchrotron radiation

The Talbot interferometer using white synchrotron radiation has already been demonstrated for high-speed X-ray phase imaging and tomography as well as four-dimensional phase tomography for an observation of a dynamic specimen. In those previous experiments, the grating lines were oriented horizontally because the synchrotron radiation source size is large in the horizontal direction, and only the vertical spatial coherence satisfies the requirement for the operation of the Talbot interferometer given its distance from the source. For non-rigid samples, the horizontal axis of rotation causes unwanted motion of the sample due to gravity which results to artifact in the tomography reconstruction. For fluid samples, a vertical rotation axis is certainly necessary. While it is possible to orient the sample rotation axis perpendicular to the grating lines of the Talbot interferometer, solving the definite integral of the differential phase images to obtain the phase shift for x-ray phase tomography proves to be cumbersome when the sample extends outside the image and there is no null region for which the integration constant is known. In this work we aimed at increasing the spatial coherence of the x-rays along the horizontal so that the grating lines and the sample rotation axis could be oriented vertically. A Talbot-Lau interferometer was constructed by adding an absorption grating which acted as vertical line sources of horizontally spatially coherent white synchrotron radiation to the Talbot interferometer. An average of 20% moire fringe visibility was obtained. The set-up was demonstrated for highspeed phase tomography of a polymer sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of errors in the electron density measurements of a tangential interferometer/polarimeter system during a tokamak discharge

A new method for the comparative verification of electron density measurements obtained with a tangential interferometer and a polarimeter during a discharge is proposed. The possible errors associated with the interferometer and polarimeter are classified by the time required for their identification. Based on the characteristics of the errors, the fringe shift error of the interferometer and the low-frequency noise of the polarimeter were identified and corrected for the JT-60U tangential interferometer/polarimeter system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coherent growth of superconducting TiN thin films by plasma enhanced molecular beam epitaxy

We have investigated the formation of titanium nitride (TiN) thin films on (001) MgO substrates by molecular beam epitaxy and radio frequency acitvated nitrogen plasma. Although cubic TiN is stabile over a wide temperature range, superconducting TiN films are exclusively obtained when the substrate temperature exceeds 710 Degree-Sign C. TiN films grown at 720 Degree-Sign C show a high residual resistivity ratio of approximately 11 and the superconducting transition temperature (T{sub c}) is well above 5 K. Superconductivity has been confirmed also by magnetiztion measurements. In addition, we determined the upper critical magnetic field ({mu}{sub 0}H{sub c2}) as well as the corresponding coherence length ({xi}{sub GL}) by transport measurements under high magnetic fields. High-resolution transmission electron microscopy data revealed full in plane coherency to the substrate as well as a low defect density in the film, in agreement with a mean-free path length Script-Small-L Almost-Equal-To 106 nm, which is estimated from the residual resistivity value. The observations of reflection high energy electron diffraction intensity oscillations during the growth, distinct Laue fringes around the main Bragg peaks, and higher order diffraction spots in the reciprocal space map suggest the full controlability of the thickness of high quality superconducting TiN thin films.

36 MATERIALS SCIENCE↗