Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Climate Change: A New Metric to Measure Changes in the Frequency of Extreme Temperatures using Record Data

Consensus on global warming is the result of multiple and varying lines of evidence, and one key ramification is the increase in frequency of extreme climate events including record high temperatures. Here we develop a metric- called "record equivalent draws" (RED)-based on record high (low) temperature observations, and show that changes in RED approximate changes in the likelihood of extreme high (low) temperatures. Since we also show that this metric is independent of the specifics of the underlying temperature distributions, RED estimates can be aggregated across different climates to provide a genuinely global assessment of climate change. Using data on monthly average temperatures across the global landmass we find that the frequency of extreme high temperatures increased 10-fold between the first three decades of the last century (1900-1929) and the most recent decade (1999-2008). A more disaggregated analysis shows that the increase in frequency of extreme high temperatures is greater in the tropics than in higher latitudes, a pattern that is not indicated by changes in mean temperature. Our RED estimates also suggest concurrent increases in the frequency of both extreme high and extreme low temperatures during 2002-2008, a period when we observe a plateauing of global mean temperature. Using daily extreme temperature observations, we find that the frequency of extreme high temperatures is greater in the daily minimum temperature time-series compared to the daily maximum temperature time-series. There is no such observable difference in the frequency of extreme low temperatures between the daily minimum and daily maximum.

Munasinghe, L.↗

Statistical Study of the Non-Thermal Continuum Radiation Beaming Angle Measured By the High Frequency Receiver on Van Allen Probes-A

The nonthermal continuum (NTC) radiation beaming angle is computed over the entire Van Allen Probes-A mission when the spacecraft was in the dawn sector. The conditions in the dawn sector are favorable for the wave vector to lie near/in the spacecraft's spin plane allowing a favorable estimate of the beaming angle, and the dawn sector is also advantageous in that previous studies show NTC occurrence to peak in this sector. We found that scatter plots, over the entire mission, of beaming angle versus magnetic latitude form a distinct inverted-V pattern, with the apex at/near the magnetic equator. This pattern was sharpest for frequencies (f) ≲ 100 kHz. Using the NTC beaming formula from the linear mode conversion theory (LMCT), we show that such an inverted-V pattern is expected due to the large variation in the plasmapause location over the entire mission. The theoretical derived pattern qualitatively reproduces the observed pattern but not quantitatively. The lack of quantitative agreement is discussed and is attributed to several factors, one factor is off-centered emissions from the radio window. The qualitative agreement strongly supports LMCT as being the dominant mechanism generating NTC for f ≲ 100 kHz. For f ≳ 100 kHz, the inverted-V pattern becomes less distinct, and strong near-equatorial beaming is observed. After considering contamination of our selections by left-handed polarized AKR, our study suggests that besides LMCT another unidentified NTC generation mechanism becomes important for f ≳ 100 kHz.

Linear Mode Conversion Theory↗

Near-millimeter spectrum of the microwave background

A description is given of a method for the measurement of the cosmic microwave background (CMB) spectrum. A helium-cooled, balloon-borne spectrophotometer was used to measure the emission spectrum of the night sky over the frequency range 1.7-40/cm. The apparatus was calibrated using a blackbody source at a variety of temperatures both before and after the flight. It is shown that the spectrum of the CMB peaks at 6/cm and is approximately that of a blackbody out to several times that frequency. The measured flux is also found to be equivalent to that from a blackbody in the temperature range from 2.88 to 3.09 K. The data set resulting from the combination of these measurements with previous observations of the CMB covers three decades in frequency, and is compared with various CMB models.

Woody, D. P.↗

A validation of LTRAN2 with high frequency extensions by comparisons with experimental measurements of unsteady transonic flows

A high frequency extension of the unsteady, transonic code LTRAN2 was created and is evaluated by comparisons with experimental results. The experimental test case is a NACA 64A010 airfoil in pitching motion at a Mach number of 0.8 over a range of reduced frequencies. Comparisons indicate that the modified code is an improvement of the original LTRAN2 and provides closer agreement with experimental lift and moment coefficients. A discussion of the code modifications, which involve the addition of high frequency terms of the boundary conditions of the numerical algorithm, is included.

Hessenius, K. A.↗

13CO2/12CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 micrometers

A portable modular gas sensor for measuring the 13C/12C isotopic ratio in CO2 with a precision of 0.8%(+/-1 sigma) was developed for volcanic gas emission studies. This sensor employed a difference frequency generation (DFG)-based spectroscopic source operating at 4.35 micrometers (approximately 2300 cm-1) in combination with a dual-chamber gas absorption cell. Direct absorption spectroscopy using this specially designed cell permitted rapid comparisons of isotopic ratios of a gas sample and a reference standard for appropriately selected CO2 absorption lines. Special attention was given to minimizing undesirable precision degrading effects, in particular temperature and pressure fluctuations.

NASA Discipline Life Sciences Technologies↗

Precise time and time interval applications to electric power systems

There are many applications of precise time and time interval (frequency) in operating modern electric power systems. Many generators and customer loads are operated in parallel. The reliable transfer of electrical power to the consumer partly depends on measuring power system frequency consistently in many locations. The internal oscillators in the widely dispersed frequency measuring units must be syntonized. Elaborate protection and control systems guard the high voltage equipment from short and open circuits. For the highest reliability of electric service, engineers need to study all control system operations. Precise timekeeping networks aid in the analysis of power system operations by synchronizing the clocks on recording instruments. Utility engineers want to reproduce events that caused loss of service to customers. Precise timekeeping networks can synchronize protective relay test-sets. For dependable electrical service, all generators and large motors must remain close to speed synchronism. The stable response of a power system to perturbations is critical to continuity of electrical service. Research shows that measurement of the power system state vector can aid in the monitoring and control of system stability. If power system operators know that a lightning storm is approaching a critical transmission line or transformer, they can modify operating strategies. Knowledge of the location of a short circuit fault can speed the re-energizing of a transmission line. One fault location technique requires clocks synchronized to one microsecond. Current research seeks to find out if one microsecond timekeeping can aid and improve power system control and operation.

Robert E. Wilson↗

Ambient and cryogenic temperature testing of a 32-channel CMOS multiplexer

A 32 channel CMOS multiplexer was tested at room temperature and at liquid helium temperature (4.9 K). Voltage gain of the FET input stage, leakage current, electrical crosstalk, and noise as a function of clock frequency were measured. The voltage gain measured at 4.9 K was slightly higher than that measured at 300 K and was independent of clock frequency at both operating temperatures. The off channel leakage current was 0.23 pA/channel at 4.9 K. Electrical crosstalk between adjacent channels (one on, one off) was quite low. The spot noise at 10 Hz, of the CMOS multiplexer operating in the static mode did not vary significantly with operating temperature. In the dynamic mode (3.2 kHz clock) at room temperature, the spot noise at 10 Hz was substantially higher than that measured in the static mode.

Lee, J. H.↗

Lifetime-Limited Interrogation of Two Independent 27 Al + Clocks Using Correlation Spectroscopy

Laser decoherence limits the stability of optical clocks by broadening the observable resonance linewidths and adding noise during the dead time between clock probes. Correlation spectroscopy avoids these limitations by measuring correlated atomic transitions between two ensembles, which provides a frequency difference measurement independent of laser noise. Here, we apply this technique to perform stability measurements between two independent clocks based on the 1 S 0 ↔ 3 P 0 transition in 27 Al + . By stabilizing the dominant sources of differential phase noise between the two clocks, we observe coherence between them during synchronous Ramsey interrogations as long as 8 s at a frequency of 1.12 × 10 15 Hz. Here, the observed contrast in the correlation spectroscopy signal is consistent with the 20.6 s 3 P 0 state lifetime and represents a measurement instability of (1.8 ± 0.5) × 10 –16 /√τ/s for averaging periods longer than the probe duration when dead time is negligible.

74 ATOMIC AND MOLECULAR PHYSICS↗

Investigation of Cloud Interior Structure Using a Tomographic Technique Based on Radon Transform. Application to the Measurements Made by the Research Scanning Polarimeter During CAMP2Ex

The Research Scanning Polarimeter (RSP) is an airborne along-track scanner measuring the polarized and total reflectances in 9 spectral channels. The RSP's uniquely high angular resolution coupled with the high frequency of measurements allows for characterization of liquid-water cloud droplet sizes using the rainbow structure observed in the polarized reflectance measurements. The RSP observations also provide for derivation of 2D field of extinction coefficient inside the cloud using a tomographic technique. This technique utilizes the family of cloud shapes derived using "cutout" technique and corresponding to a number of thresholds in total reflectance (separating bright cloud from its darker background). These shapes can be interpreted as level curves of an abstract "reflectance density", which is then used for derivation of the directional cloud optical thickness (dCOT) tomogram. The latter is a collection of dCOTs parameterized by the angles and offsets of the corresponding view rays (chords) relative to the cloud center. After this, the inverse Radon Transform (the mathematical basis of the X-ray com-puter tomography) is applied to the dCOT tomogram yielding 2D spatial distribution of the extinction coefficient. The later can be converted into droplet number concentration using the droplet size profiles derived from the RSP's polarized reflectance measurements. After tests on synthetic data this technique was applied to real RSP measurements from NASA's Cloud, Aerosol and Monsoon Processes Philippines Experiment (CAMP2Ex) conducted in the vicinity of the Philippines during the Southwest Monsoon (August–September 2019). We have investigated the interiors of a number of clouds observed during CAMP2Ex focusing on Cu and CuCg (Tcu) cases. Our retrievals were routinely compared with the correlative measurements by lidar (HSRL-2) and cloud radar (APR-3) that were deployed on the same airborne platform (NASA P-3B) during this field experiment.

Research Scanning Polarimeter↗

Transition frequencies and absolute strengths of H2 O-17 and H2 O-18 in the 6.2-micron region

High-resolution spectra of oxygen-enriched samples of water vapor were recorded with a Fourier-transform spectrometer covering transitions in the (010)-(000) bands. The measured line frequencies were used along with measurements taken from studies at microwave and far-infrared frequencies to obtain rotational energy levels in the (000) and (010) states of H2 O-17 and H2 O-18. Measurements of the line strengths were fitted to a model in which as many as 18 transition moment parameters were determined. The results produced computed line-strength values that are in excellent agreement with the 623 H2 O-17 experimental transition strengths and 696 H2 O-18 values. These results provide a more accurate representation of the line positions and strengths for the (010)-(000) bands of H2 O-17 and H2 O-18 than those previously available.

Toth, Robert A.↗

Determination of nonlinear resistance voltage-current relationships by measuring harmonics

Test configuration measures harmonic signal amplitudes generated in nonlinear resistance. Vacuum-type voltmeter measures low frequency sinusoidal input signal amplitude and wave-analyzer measures amplitude of harmonic signals generated in junction. Input signal harmonics amplitude must not exceed that of harmonics generated in nonlinear resistance.

Stafford, J. M.↗