Experimental investigation of residence time and axial velocity of 6.0 cm graphite pebbles in a cold-flow pebble bed reactor using radioisotope-based technique
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Not provided.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
High-temperature gas-cooled reactors (HTGRs) are notable for their high thermal efficiency and potential for combined heat and power applications. These reactors are particularly appealing due to their advanced passive safety features. HTGRs utilize passive safety systems that function without requiring active components like pumps or compressors during emergencies. These reactor designs depend on a Reactor Cavity Cooling System (RCCS) to manage decay heat removal from the reactor pressure vessel (RPV) during accident conditions. The RCCS consists of vertical rectangular channels known as "risers" or riser ducts positioned around the RPV. These risers receive heat from the RPV through both convective and radiative heat transfer mechanisms. Understanding the interplay of multiple physical phenomena, such as fluid dynamics, heat transfer, and neutron interactions, is essential for the effective design and operation of nuclear reactors, particularly for systems like the RCCS. Multi-physics simulations provide a comprehensive approach to studying these interactions, offering detailed insights and enhancing accuracy. They are especially important in RCCS designs, where the interaction between radiative and convective heat transfer can significantly impact system performance. By leveraging multi-physics simulations, complex reactor behaviors can be modeled without compromising the fidelity of the underlying physical processes. This work aims to establish a robust methodology for coupling multiple physical processes in an air-cooled RCCS. By focusing on validating this multi-physics approach, the study involves designing test cases that simulate various conditions to verify the numerical models employed. The outcomes of this research will provide critical insights for accurately modeling and optimizing complex nuclear systems like the RCCS.
Equilibrium flow characteristics of simulated gas cooled reactor passage
Upper plenum flow behavior is important for many operational and safety issues in sodium fast reactors. The Prototype Gen-IV Sodium Fast Reactor (PGSFR), a pool-type, 150 MWe output power design, was used as a reference case for a detailed characterization of upper plenum flow for normal operating conditions. Computational Fluid Dynamics (CFD) simulation was utilized with detailed geometric modeling of major structures. Core outlet conditions based on prior system-level calculations were mapped to approximate the outlet temperatures and flow rates for each core assembly. Core outlet flow was found to largely bypass the Upper Internal Structures (UIS). Flow curves over the shield and circulates within the pool before exiting the plenum. Cross-flows and temperatures were evaluated near the core outlet, leading to a proposed height for the core outlet thermocouples to ensure accurate assembly-specific temperature readings. A passive scalar was used to evaluate fluid residence time from core outlet to IHX inlet, which can be used to assess the applicability of various methods for monitoring fuel failure. Additionally, the gas entrainment likelihood was assessed based on the CFD simulation results. Based on the evaluation of velocity gradients and turbulent kinetic energies and the available gas entrainment criteria in the literature, it was concluded that significant gas entrainment is unlikely for the current PGSFR design.
Turbulent flow coupled with heat transfer is investigated for a High Flux Isotope Reactor (HFIR) fuel plate. The Reynolds Averaged Navier-Stokes Models are used for fluid dynamics and the transfer of heat from a thermal nuclear fuel plate using the Multi-physics code COMSOL. Simulation outcomes are compared with experimental data from the Advanced Neutron Source Reactor Thermal Hydraulic Test Loop. The computational results for the High Flux Isotope Reactor core system provide a more physically accurate simulation of this system by modeling the turbulent flow field in conjunction with the diffusion of thermal energy within the solid and fluid phases of the model domain. Recommendations are made regarding Nusselt number correlations and material properties for future thermal hydraulic modeling efforts
Multiphase flow hydrodynamics in a novel gas–liquid–solid jet-loop reactor (JLR) were experimentally investigated at the macroscales and mesoscales. The chord length distribution was measured by an optical fiber probe and transformed for bubble size distribution through the maximum entropy method. The impacts of key operating conditions (superficial gas and liquid velocity, solid loading) on hydrodynamics at different axial and radial locations were comprehensively investigated. JLR was found to have good solid suspension ability owing to the internal circulation of bubbles and liquid flow. The gas holdup, axial liquid velocity, and bubble velocity increase with gas velocity, while liquid velocity has little influence on them. Compared with the gas–liquid JLRs, solids decrease the gas holdup and liquid circulation, reduces the bubble velocity and delays the flow development due to the enhanced interaction between bubbles and particles (Stokes number >1). This work also provides a benchmark data for computational fluid dynamics (CFD) model validation.
The safety and security nuclear power plant operations depends on the application of the most appropriate techniques and methods of chemical analysis, where modern flow analysis methods find increasing applications. Nevetheless, the current status of development of these methods is more limited than might be expected from their authentic advantages. The main aim of this contribution is to review automated flow analysis procedures developed with various detection methods for application in the nuclear energy industry. The flow analysis methods for determination of radionuclides that have been reported to date have been primarily focused mainly on environmental applications. The needs and benefits of the application of flow methods for the monitoring of nuclear wastes and for process analysis of the primary circuit coolants of light water nuclear reactors are discussed. Application of continuous flow methods (CFA) or injection methods (FIA, SIA) of flow analysis with radiometric detection shorterns the time of analysis and improves precision of determinations due to mechanization of time-consuming operations of sample processing. The use of mass spectrometry (MS) detection enables multicomponent analyses and determination of transuranic isotopes with much better limits of detection compared to radiometric detection.
Not Available
The reaction of Cl atoms, in the presence of Cl2 and O2, with sub-micron squalane particles is used as a model system to explore how surface hydrogen abstraction reactions initiate chain reactions that rapidly transform the chemical composition of an organic particle. The heterogeneous reaction is measured in a photochemical flow tube reactor in which chlorine atoms are produced by the photolysis of Cl2 at 365 nm. By monitoring the heterogeneous reaction, using a vacuum ultraviolet photoionization aerosol mass spectrometer, the effective reactive uptake coefficient and the distributions of both oxygenated and chlorinated reaction products are measured and found to depend sensitively upon O2, Cl2, and Cl concentrations in the flow reactor. In the absence of O2, the effective reactive uptake coefficient monotonically increases with Cl2 concentration to a value of ~;;3, clearly indicating the presence of secondary chain chemistry occurring in the condensed phase. The effective uptake coefficient decreases with increasing O2 approaching a diffusion corrected value of 0.65 ? 0.07, when 20percent of the total nitrogen flow rate in the reactor is replaced with O2. Using a kinetic model it is found that the amount of secondary chemistry and the product distributions in the aerosol phase are controlled by the competitive reaction rates of O2 and Cl2 with alkyl radicals. The role that a heterogeneous pathway might play in the reaction of alkyl radicals with O2 and Cl2 is investigated within a reasonable range of reaction parameters. These results show, more generally, that for heterogeneous reactions involving secondary chain chemistry, time and radical concentration are not interchangeable kinetic quantities, but rather the observed reaction rate and product formation chemistry depends sensitively upon the concentrations and time evolution of radical initiators and those species that propagate or terminate free radical chain reactions.
Strain NA10B{sup T} and other two strains of the denitrifying betaproteobacterium Diaphorobacter nitroreducens were studied for the performance of solid-phase denitrification (SPD) using poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) and some other biodegradable plastics as the source of reducing power in wastewater treatment. Sequencing-batch SPD reactors with these organisms and PHBV granules or flakes as the substrate exhibited good nitrate removal performance. Vial tests using cultures from these parent reactors showed higher nitrate removal rates with PHBV granules (ca. 20 mg-NO{sub 3}{sup −}‐N g{sup −1} [dry wt cells] h{sup −1}) than with PHBV pellets and flakes. In continuous-flow SPD reactors using strain NA10B{sup T} and PHBV flakes, nitrate was not detected even at a loading rate of 21 mg-NO{sub 3}{sup −}‐N L{sup −1} h{sup −1}. This corresponded to a nitrate removal rate of 47 mg-NO{sub 3}{sup −}‐N g{sup −1} (dry wt cells) h{sup −1}. In the continuous-flow reactor, the transcription level of the phaZ gene, coding for PHB depolymerase, decreased with time, while that of the nosZ gene, involved in denitrificaiton, was relatively constant. These results suggest that the bioavailability of soluble metabolites as electron donor and carbon sources increases with time in the continuous-flow SPD process, thereby having much higher nitrate removal rates than the process with fresh PHBV as the substrate.
Nuclear reactor system analyses rely on multiple complex models which describe the physics of reactor neutronics, thermal hydraulics, structural mechanics, coolant physico-chemistry, etc. Such coupled multiphysics models require extensive calibration and validation before they can be used in practical system safety study and/or design/technology optimization. This paper presents an application of statistical modeling and Bayesian inference in calibrating an example multiphysics model of subcooled boiling flows which is widely used in reactor thermal hydraulic analysis. The presence of complex coupling of physics in such a model together with the large number of model inputs, parameters and multidimensional outputs poses significant challenge to the model calibration method. However, the method proposed in this work is shown to be able to overcome these difficulties while allowing data (observation) uncertainty and model inadequacy to be taken into consideration. (authors)
Several pressurized water reactor (PWR) systems under development employ integral primary coolant loop designs, where the primary coolant does not leave the reactor pressure vessel during operation (I{sup 2}S-LWR, mPower, NuScale). The absence of primary coolant piping inhibits traditional pressurized water reactor primary coolant flow measurement, in which the differential pressure across the steam generator is correlated to flow rate. To address this, a transit time, reflection mode, ultrasonic flow meter is proposed. An experimental flow loop utilizing a test section representative of a thin azimuthal slice of the down-comer region of an integral PWR has been constructed to test the efficacy of the General Electric AT600 ultrasonic flow meter (UFM) in such an application. A Great Plains Industries TM300 turbine flow meter (TFM), reporting volumetric flow rate and installed in-line with the flow loop piping, is used as the reference meter. UFM performance is affected by several factors, including flow development and symmetry. The UFM was installed on three locations along the flow path of water through the test section. The meter performed the best at the downstream end of the test section, where the fluid flow is the most developed. Performance, measured by percent error in UFM average reading with respect to the TFM average reading, generally improved with increasing flow rate at all locations, though absolute difference between meter readings increased with flow rate. This research suggests that ultrasonic approaches hold promise for non-invasive measurement of primary coolant flow in integral PWRs. (authors)
We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.